Surgery | 2014

Intraoperative neuromonitoring for the early detection and prevention of RLN traction injury in thyroid surgery: A porcine model

Che-Wei Wu; Gianlorenzo Dionigi; Hui Sun; Xiaoli Liu; Hoon Kim; Pi-Jung Hsiao; Kuo-Bow Tsai; Hui-Chun Chen; Hsiu-Ya Chen; Pi-Ying Chang; I-Cheng Lu; Feng-Yu Chiang

BACKGROUND Operative traction of the thyroid lobe is a necessary component of thyroid surgery. This surgical maneuver can cause traction injury of the recurrent laryngeal nerve (RLN), and this complication has been reported to be the most common mechanism of nerve injury. The goal of this study was to investigate the electromyographic (EMG) signal pattern during an acute RLN traction injury and establish reliable strategies to prevent the injury using intraoperative neuromonitoring (IONM). METHODS Fifteen piglets (30 RLNs) underwent IONM via automated periodic vagal nerve stimulation and had their EMG tracings recorded and correlated with various models of nerve injury. RESULTS In the pilot study, a progressive, partial EMG loss was observed under RLN tractions with different tension (n = 8). The changes in amplitudes were more marked and consistent than were the changes in latency. The EMG gradually gained partial recovery after the traction was relieved. Among the nerves injured with electrothermal (n = 4), clamping (n = 1), and transection (n = 1) models, the EMG showed immediate partial or complete loss, and no gradual EMG recovery was observed. Another 16 RLNs were used to investigate the potential of EMG recovery after different extents of RLN traction. We noted the EMG showed nearly full recovery if the traction stress was relieved before the loss of signal (LOS), but the recovery was worse if prolonged or repeated traction was applied. The mean restored amplitudes after the traction was relieved before, during, and after the LOS were 98 ± 3% (n = 6), 36 ± 4% (n = 4), and 15 ± 2% (n = 6), respectively. CONCLUSION RLN traction injury showed graded, partial EMG changes; early release of the traction before the EMG has degraded to LOS offers a good chance of EMG recovery. IONM can be used as a tool for the early detection of adverse EMG changes that may alert surgeons to correct certain maneuvers immediately to prevent irreversible nerve injury during the thyroid operation.


Head and Neck-journal for The Sciences and Specialties of The Head and Neck | 2012

Vagal nerve stimulation without dissecting the carotid sheath during intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid surgery

Che-Wei Wu; Gianlorenzo Dionigi; Hui-Chun Chen; Hsiu-Ya Chen; Ka-Wo Lee; I-Cheng Lu; Pi-Ying Chang; Pi-Jung Hsiao; Kuen-Yao Ho; Feng-Yu Chiang

Vagal nerve stimulation (VNS) has been recommended as a routine procedure during intraoperative neuromonitoring (IONM) of the recurrent laryngeal nerve (RLN). However, many surgeons have been discouraged from performing VNS because of the need for opening the carotid sheath. The purpose of this study was to investigate the feasibility and reliability of VNS without carotid sheath dissection.


Laryngoscope | 2015

Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model

Yi-Chu Lin; Gianlorenzo Dionigi; Gregory W. Randolph; I-Cheng Lu; Pi-Ying Chang; Shan‐Yin Tsai; Hoon Kim; Hye Yoon Lee; Ralph P. Tufano; Hui Sun; Xiaoli Liu; Feng-Yu Chiang; Che-Wei Wu

Thermal injury to the recurrent laryngeal nerve (RLN) may not be visually apparent and may go unrecognized intraoperatively. This study aimed to investigate the heat thermal tolerance of RLN and evaluate the electrophysiologic correlates of electromyographic (EMG) signal change during an acute RLN heat damage.


Gland surgery | 2015

Loss of signal in recurrent nerve neuromonitoring: causes and management

Che-Wei Wu; Mei-Hui Wang; Cheng-Chien Chen; Hui-Chun Chen; Hsiu-Ya Chen; Jing-Yi Yu; Pi-Ying Chang; I-Cheng Lu; Yi-Chu Lin; Feng-Yu Chiang

During recurrent laryngeal nerve (RLN) neuromonitoring in thyroid surgery, laryngeal electromyography (EMG) amplitude may be correlated with the number of muscle fibers participating in the polarization and these might be correlated with the function of RLN. If RLN is severely injured during the operation, most nerve fibers do not transmit nerve impulse and substantial decrease of EMG amplitude or loss of signal (LOS) will occur. True LOS at the end of an operation often indicates a postoperative fixed vocal cord, and the surgeon should consider the optimal contralateral surgery timing in patients with planned bilateral thyroid operation to avoid the disaster of bilateral vocal cord palsy. However, LOS recovery and false LOS may occur and may lead to an unnecessary 2(nd) operation. Therefore, a reliable modality for intraoperative LOS evaluation and management would afford the surgeon real-time information that could help guide surgical procedure and planning. The updated causes, algorithm, and management of LOS during RLN neuromonitoring are reviewed and summarized.


Laryngoscope | 2015

Stimulating dissecting instruments during neuromonitoring of RLN in thyroid surgery

Feng-Yu Chiang; I-Cheng Lu; Pi-Ying Chang; Hui Sun; Ping Wang; Xiu‐Bo Lu; Hui-Chun Chen; Hsiu-Ya Chen; Hoon Kim; Gianlorenzo Dionigi; Che-Wei Wu

During intraoperative neuromonitoring (IONM) of recurrent laryngeal nerve (RLN) in thyroid surgery, the need for frequent shifting between the dissecting instruments and stimulating probe is troublesome and time‐consuming. Therefore, use of these two instruments in combination would be a noticeable future direction. This study aimed to investigate the feasibility and safety of using stimulating dissecting instruments (SDIs) that combine the function of surgical dissection and nerve stimulation during IONM.


Laryngoscope | 2016

Reversal of rocuronium-induced neuromuscular blockade by sugammadex allows for optimization of neural monitoring of the recurrent laryngeal nerve

I-Cheng Lu; Che-Wei Wu; Pi-Ying Chang; Hsiu-Ya Chen; Kuang-Yi Tseng; Gregory W. Randolph; Kuang-I Cheng; Feng-Yu Chiang

The use of neuromuscular blocking agent may effect intraoperative neuromonitoring (IONM) during thyroid surgery. An enhanced neuromuscular‐blockade (NMB) recovery protocol was investigated in a porcine model and subsequently clinically applied during human thyroid neural monitoring surgery.


Kaohsiung Journal of Medical Sciences | 2013

A comparison between succinylcholine and rocuronium on the recovery profile of the laryngeal muscles during intraoperative neuromonitoring of the recurrent laryngeal nerve: a prospective porcine model.

I-Cheng Lu; Pi-Ying Chang; Hung-Te Hsu; Kuang-Yi Tseng; Che-Wei Wu; Ka-Wo Lee; Kuen-Yao Ho; Feng-Yu Chiang

The use of succinylcholine and rocuronium are reportedly feasible during intraoperative neuromonitoring (IONM) of the recurrent laryngeal nerve (RLN) in thyroid surgery. This study aimed to investigate and compare the recovery profiles of succinylcholine and rocuronium on the laryngeal muscle during IONM of the RLN in a porcine model. Nine male Duroc‐Landrace piglets were anesthetized with thiamylal and underwent tracheal intubation without neuromuscular blocking agents (NMBAs). Needle electrodes were inserted into the vocalis muscles through the cricothyroid ligament. The RLN was exposed and stimulated. Electromyographic (EMG) signals were obtained before and after the intravenous administration of a NMBA. The EMG amplitudes were measured before and after (at 1‐minute intervals) the administration of the study drug until complete recovery. The study NMBA regimen included succinylcholine (1 mg/kg), low‐dose rocuronium (0.3 mg/kg), and standard dose rocuronium (0.6 mg/kg). The maximal neuromuscular blockade and 80% recovery (i.e., duration) of the control responses were recorded and analyzed. The 80% recovery of the control response for succinylcholine (1 mg/kg) was 19.7 ± 1.5 minutes; low‐dose rocuronium (0.3 mg/kg), 16.3 ± 2.5 minutes; and standard dose rocuronium (0.6 mg/kg), 29.3 ± 5.7 minutes. Succinylcholine (1 mg/kg) and low‐dose rocuronium (0.3 mg/kg) had significantly shorter durations than standard dose rocuronium (0.6 mg/kg). The EMG signal recovery returned to baseline within 30 minutes in the succinylcholine and low‐dose rocuronium groups, but it did not return to baseline until 1 hour after surgery in the rocuronium (0.6 mg/kg) group. In this study, succinylcholine (1 mg/kg) and low‐dose rocuronium (0.3 mg/kg) had favorable recovery profiles on the laryngeal muscle. It is recommended that low‐dose rocuronium may replace succinylcholine for the induction of general anesthesia during IONM of the RLN in thyroid surgery.


Kaohsiung Journal of Medical Sciences | 2014

Influence of intravenous anesthetics on neuromonitoring of the recurrent laryngeal nerve during thyroid surgery

Pi-Ying Chang; Che-Wei Wu; Hsiu-Ya Chen; Hui-Chun Chen; Kuang-I Cheng; I-Cheng Lu; Feng-Yu Chiang

Limited reports are available in the literature on the impact of intravenous administration of anesthetics on laryngeal electromyographic (EMG) activity. The purpose of this study was to determine the influence of the two commonly used intravenous anesthetics (propofol and thiamylal) on EMG amplitude evoked from the recurrent laryngeal nerve (RLN) during thyroid surgery. A total of 40 patients were randomized to receive a bolus of propofol (0.5 mg/kg; n = 20) or thiamylal (1.5 mg/kg; n = 20) to increase anesthetic depth when the surgeon found patient movement intraoperatively. Evoked potentials were obtained before and every 1 minute after the administration of each agent for up to 5 minutes by stimulating the RLN. The magnitude of evoked potentials at each time point and hemodynamic response were compared within groups. The mean amplitude of evoked potentials did not change significantly after administration of either propofol or thiamylal (p > 0.05 within groups). Mean arterial pressure measured from 1 minute to 5 minutes was significantly lower in the propofol group than in the thiamylal group (p < 0.05). Heart rate measured within 5 minutes did not differ significantly within groups. Low dose of propofol (0.5 mg/kg) or thiamylal (1.5 mg/kg) did not affect EMG readings during neuromonitoring of the RLN in thyroid surgery. Our results show that thiamylal provides better hemodynamic stability than propofol, and is therefore a preferable agent to increase anesthesia depth and prevent further patient movement during intraoperative neuromonitoring.


Laryngoscope | 2017

Safety of LigaSure in recurrent laryngeal nerve dissection-porcine model using continuous monitoring

Gianlorenzo Dionigi; Feng-Yu Chiang; Hoon Kim; Gregory W. Randolph; Alberto Mangano; Pi-Ying Chang; I-Cheng Lu; Yi-Chu Lin; Hui-Chun Chen; Che-Wei Wu

This study investigated recurrent laryngeal nerve (RLN) real‐time electromyography (EMG) data to define optimal safety parameters of the LigaSure Small Jaw (LSJ) instrument during thyroidectomy.


Laryngoscope | 2017

In response toReversal of rocuronium-induced neuromuscular blockade by sugammadex allows for optimization of neural monitoring of the recurrent laryngeal nerve: Letter to the Editor

I-Cheng Lu; Che-Wei Wu; Pi-Ying Chang; Hsiu-Ya Chen; Kuang-Yi Tseng; Gregory W. Randolph; Kuang-I Cheng; Feng-Yu Chiang

Brunaud and Fuchs-Buder wrote a letter in response to our recent study to bring the selective sugammadex reversal approach for neural monitoring to the attention of readers. They stated that the need for sugammadex to restore neuromuscular function allowing adequate intraoperative neuromonitoring (IONM) is rather infrequent and observed in less than approximately 20% of patients. Consequently, compared to routine reversal of rocuronium neuromuscular blockade with sugammadex, a selective reversal approach may be sufficient and more cost-effective. First, we accept as true that recovery from rocuronium-induced neuromuscular blockade is significantly faster at the laryngeal muscles compared to the adductor pollicis muscle. Appropriate IONM may be allowed in most patients while the adductor pollicis is still paralyzed. However, the dose of rocuronium and the time of nerve stimulation is critical for successful IONM. In our previous study, in the patients who received a standard intubating dose of rocuronium (0.6 mg/kg), the rate of positive electromyographic (EMG) response from vagal stimulation was only 53% at 30 minutes after rocuronium injection; only at 55 minutes did the rate of positive EMG response reach 100% in these patients. Furthermore, the mean EMG amplitude was markedly lower from 30 to 60 minutes. Second, a higher initial EMG signal is also crucial as 1) it can be as a reference to be compared with the final signal to predict the outcome of vocal cord function, 2) it is helpful to map the path of the recurrent laryngeal nerve intraoperatively, and 3) it is useful to detect early adverse signal change to prevent imminent nerve injury, particularly for continuous IONM. Third, because sugammadex is currently an expensive product, a selective reversal approach may be more cost-effective. However, we have to emphasize that when a standard dose of rocuronium (0.6 mg/kg) is used for tracheal intubation, the recovery from neuromuscular blockade after rocuronium varies widely between subjects and may lead to a false-negative IONM result. If we take the cost of sugammadex into consideration, a reduced dosage of rocuronium (0.3 mg/kg) can be another option.

Collaboration


Dive into the Pi-Ying Chang's collaboration.

Top Co-Authors

Avatar

I-Cheng Lu

Kaohsiung Medical University

View shared research outputs
Top Co-Authors

Avatar

Che-Wei Wu

Kaohsiung Medical University

View shared research outputs
Top Co-Authors

Avatar

Feng-Yu Chiang

Kaohsiung Medical University

View shared research outputs
Top Co-Authors

Avatar

Hsiu-Ya Chen

Kaohsiung Medical University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yi-Chu Lin

Kaohsiung Medical University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hui-Chun Chen

Kaohsiung Medical University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kuang-Yi Tseng

Kaohsiung Medical University

View shared research outputs
Researchain Logo
Decentralizing Knowledge