Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Pierre Alric is active.

Publication


Featured researches published by Pierre Alric.


European Journal of Vascular and Endovascular Surgery | 2011

Endovascular Repair of Aorto-iliac Artery Injuries after Lumbar-spine Surgery

Ludovic Canaud; K. Hireche; F. Joyeux; T. D’Annoville; J.-P. Berthet; C. Marty-Ané; Pierre Alric

OBJECTIVE This study aims to describe the endovascular management of abdominal-aortic- or common-iliac-artery injuries after lumbar-spine surgery. METHODS Patients treated for abdominal-aortic- or common-iliac-artery injuries after lumbar-spine surgery during a 13-year period were identified from an endovascular database, providing prospective information on techniques and outcome. The corresponding patient records and radiographic reports were analysed retrospectively. RESULTS Seven patients were treated with acute (n = 3) or subacute (n = 4) injuries of the common iliac artery (n = 6) or abdominal aorta (n = 1) after lumbar-spine surgery. Vascular injuries included arterial lacerations (n = 3), arteriovenous fistulas (n = 2) and pseudo-aneurysms (n = 2). The mean age of the patients was 51.7 years (30-60 years), 71.4% were women. These lesions were repaired by transluminal placement of stent grafts: Passager (n = 3), Viabahn (n = 1), Wallgraft (n = 1), Zénith (n = 1) and Advanta V12 (n = 1). Exclusion of the injury was achieved in all cases. Mortality was nil. There were no procedure-related complications. During a median follow-up of 8.7 years (range 0.3-13 years), all stent grafts remained patent. CONCLUSIONS Sealing of common iliac artery or abdominal aortic lesions as a complication of lumbar-disc surgery with a stent graft is effective and is suggested as an excellent alternative to open surgery for iatrogenic great-vessel injuries, particularly in critical conditions.


Acta Chirurgica Belgica | 2009

Preoperative Assessment of Anatomical Suitability for Thoracic Endovascular Aortic Repair

Pierre Alric; Ludovic Canaud; Pascal Branchereau; Charles-Henri Marty-Ané; J.-Ph. Berthet

Abstract Endovascular treatment of descending thoracic aortic pathologies requires a preoperatively determined interventional strategy. Its feasibility depends mainly on anatomic factors: the morphology of the proximal and distal fixation sites, the diameter and disease state of the access vessels. These factors represent important predictors of success and the most important exclusion criteria. Current diagnostic evaluation of aortic aneurysm for endovascular repair relies primarily on CT scan associated with 3D-reconstruction to assess the anatomical suitability for endograft implantation. In patients with an inadequate length of the proximal or distal neck, the left subclavian artery or the coeliac trunk can be overstented to effectively exclude thoracic aortic lesions. Deliberate coverage of aortic side branches should be decided prior to the procedure (guided by a extensive anatomical assessment) or carefully be avoided in order to reduce major morbidity, especially cerebral embolization, spinal cord ischemia and ischemic abdominal complications.


Journal of Vascular Surgery | 2015

Assessment of abdominal branch vessel patency after bare-metal stenting of the thoracoabdominal aorta in a human ex vivo model of acute type B aortic dissection

Elsa Madeleine Faure; Ludovic Canaud; Philippe Cathala; Isabelle Serres; Charles Marty-Ané; Pierre Alric

OBJECTIVE The purpose of this study was to assess the efficiency of bare-metal stenting of the thoracoabdominal aorta in a human ex vivo model of acute type B aortic dissection and the impact of this approach on the patency of the visceral and renal arteries. METHODS Fifteen human cadaveric aortas were harvested. Type B aortic dissections were surgically initiated 2 cm below the left subclavian artery. Aortas were thereafter connected to a bench top pulsatile flow to induce propagation of the dissection. A 5-mm 30° lens (Richard Wolf, Vernon Hills, Ill) was introduced successively into the false lumen and the true lumen to monitor the propagation of the dissection. Bare-metal stents were deployed into the true lumen from the primary entry tear to the infrarenal aorta. Measurement of systolic pressure was taken within the abdominal branch vessels before and after stenting. A pressure gradient drop of 15 mm Hg or more after bare-metal stenting was considered hemodynamically relevant. RESULTS Dissection was propagated at least to the renal aorta in 11 cases (73%) and to the infrarenal aorta in 3 cases (20%). Of the 60 abdominal branch vessels studied, 22 (36.7%) were supplied by the false lumen. After extensive aortic bare-metal stenting, complete reattachment of the dissection flap was observed in all cases. Regarding visceral and renal artery patency after bare-metal stenting, a significant pressure gradient drop was reported in 54.5% (n = 12) when these arteries were supplied by the false lumen, whereas those originating from the true lumen had a significantly less common pressure gradient drop (7.9% [n = 3]; P < .0001). CONCLUSIONS Bare-metal stenting in this model of acute type B aortic dissection was effective in true lumen reexpansion but induced a high (54.5%) rate of significant pressure drop in the visceral and renal arteries when they were supplied by the false lumen.


Journal of Vascular Surgery | 2014

Human ex-vivo model of Stanford type B aortic dissection

Elsa Madeleine Faure; Ludovic Canaud; Philippe Cathala; Isabelle Serres; Charles Marty-Ané; Pierre Alric

OBJECTIVE To report a new human ex vivo model of type B aortic dissection (TBAD) and to assess if the locations of the primary entry tear determine the patterns of dissection propagation. METHODS Twenty fresh human aortas were harvested. TBADs were surgically initiated 2 cm below the left subclavian artery at four different locations (lateral, n = 5; medial, n = 5; anterior, n = 5; posterior, n = 5). Aortas were thereafter connected to a bench-top pulsatile flow model to induce antegrade propagation of the dissection. RESULTS Antegrade propagation of the dissection was achieved and reached at least the celiac trunk (CT) in all the cases. Dissection was propagated to the renal aorta in 16 (80%) and infrarenal aorta in seven cases (35%). Left renal artery with or without the CT originated more often from the false channel when primary entry tear was lateral. Right renal artery and the CT most often originated from the false channel when primary entry tear was medial. When the CT was the only one originating from the false channel, primary entry tear was more often anterior, whereas when it originated from the true channel, it was more often posterior. CONCLUSIONS This human ex vivo model of TBAD is reproducible, since, in all the aortas, extended dissection was achieved and provides the first model of human aortic dissection with infrarenal aorta extension allowing future assessment of endovascular devices developed for human use. Furthermore, it allows clarification of the patterns of aortic dissection propagation and visceral and renal artery involvement according to the site of the primary entry tear.


Journal of Endovascular Therapy | 2011

Impact of stent-graft development on outcome of endovascular repair of acute traumatic transection of the thoracic aorta.

Ludovic Canaud; Frédéric Joyeux; Jean-Philippe Berthet; Kheira Hireche; Charles Marty-Ané; Pierre Alric

Purpose To analyze the impact of stent-graft design on the outcome of endovascular repair of acute traumatic thoracic aortic transection. Methods Forty-eight patients (38 men; mean age 37±11 years) underwent endovascular repair for an acute traumatic aortic rupture between April 2001 and March 2011. Up to October 2007, 32 patients (mean age 41±16 years; group 1) were treated with the first generation of commercially available thoracic stent-grafts (10 Talent, 20 Excluder/TAG, 2 Zenith). From November 2007, 16 patients (mean age 42±19 years; group 2) were treated with second-generation thoracic stent-grafts (13 Valiant and 3 C-TAG). The 2 groups were statistically comparable. Follow-up computed tomography was performed at 1 week; at 3 and 6 months; and annually thereafter. Results In the 2 groups, the mortality rate related to aortic repair was nil. All the patients have completed each of their scheduled follow-up evaluations and CT scans. The morbidity rate was significantly reduced (p=0.0003) from 18.7% (first generation) to 6.2% (second generation). Type I endoleak (n=1), inadvertent coverage of the supra-aortic trunks (n=3), and stent-graft collapse (n=2) occurred only with the first-generation stent-grafts. One iliac artery rupture occurred with a second-generation stent-graft. Conclusion Enhanced stent-graft conformability and more accurate delivery systems have significantly decreased the morbidity of endovascular repair of acute traumatic transection of the thoracic aorta. The increasing clinical experience may also have contributed to improved results.


European Journal of Cardio-Thoracic Surgery | 2013

Chest-wall reconstruction in case of infection of the operative site: is there any interest in titanium rib osteosynthesis?

Jean-Philippe Berthet; Laurence Solovei; Olivier Tiffet; Abel Gómez-Caro; Sébastien Bommart; Ludovic Canaud; Pierre Alric; Charles-Henri Marty-Ané

OBJECTIVES To describe the management of thoracic reconstructions in the presence of primary chest-wall infection (PCWI) or secondary deep chest-wall infection (SCWI), focussing on local tolerance of a titanium rib osteosynthesis system. METHODS PCWI included infected chest wall tumours (CWT), infected T3 non-small-cell lung carcinoma (NSCLC) and open flail chest. SCWI was defined by deep infection of previous thoracic-wall reconstructions. Infection was identified by preoperative bacterial analysis of the tumour or surgical site. In PCWI, a one-step procedure combined extensive resection of infected tissues and rigid reconstruction of the defect; skeletal rigidity was achieved using titanium implants. In SCWI, we removed all synthetic material except titanium implants. In both groups, the surgical field was thoroughly cleaned and implants were wrapped or covered by flaps. RESULTS From January 2005 to December 2011, 11 patients (54 ± 10.2 years) with either PCWI (3 CWT, 3 T3 NSCLC, 1 open flail chest) or SCWI (3 CWT, 1 funnel chest) were treated. Infection was polymicrobial in all but 1 case. Bacteria observed in PCWI patients were multidrug resistant. In PCWI, we resected 4.2 ± 0.6 ribs en bloc with the lung (n = 5), the skin and the pectoralis major and then used mesh and 2.1 ± 1.2 titanium implants for reconstruction (n = 6). The mean defect was 1154.4 ± 318 cm(3). Surgical SCWI management removed polytetrafluoroethylene-mesh and preserved the titanium implants. A Vicryl mesh (n = 3) and greater omentum flap (n = 3) were added. One of the 2 postoperative deaths in the PCWI group was related to infection recurrence. No other patient had infection at the 6-month follow-up with leucocyte-labelled scintigraphy. CONCLUSION Titanium rib osteosynthesis is reliable in two complex and life-threatening situations: PCWIs and SCWIs. In combination with a flap, this allows rapid, reliable, rigid reconstruction of infected full-thickness chest-wall defects in a single-step procedure.


Annals of Vascular Surgery | 2013

Heparin-Induced Thrombocytopenia With Abdominal Aortic Stent-Graft Acute Thrombosis

Ludovic Canaud; Kheira Hireche; Charles Marty-Ané; Pierre Alric

We report a case of heparin-induced thrombocytopenia in a patient on low molecular weight heparin bridge therapy who developed acute abdominal aortic stent-graft thrombosis 1 week after uncomplicated endovascular abdominal aortic aneurysm repair. The diagnosis was confirmed by a computed tomographic scan of the abdomen. The patient was successfully treated by conversion to open repair. The postoperative course was marked by subacute left limb ischemia related to an in vivo cross-reactivity of danaparoid with the heparin immune complex. To our knowledge, this is the first case report of heparin-induced thrombocytopenia with acute abdominal aortic stent-graft thrombosis.


The Journal of Thoracic and Cardiovascular Surgery | 1994

Descending necrotizing mediastinitis: Advantage of mediastinal drainage with thoracotomy

Charles-Henri Marty-Ane; Michel Alauzen; Pierre Alric; Olivier Serres-Cousine; Henri Mary


European Journal of Vascular and Endovascular Surgery | 2017

Experimental Assessment of Physician Modified Proximal Scalloped Stent Graft to Extend Proximal Landing Zone in the Aortic Arch

Elsa Madeleine Faure; I. Khantalin; P.A. Peyron; Ludovic Canaud; C. Marty-Ané; Pierre Alric


Annals of Vascular Surgery | 2017

Evolution of acute type B aortic dissections: Monocentric study over 15 years

Elsa Madeleine Faure; Ludovic Canaud; Pierre Alric

Collaboration


Dive into the Pierre Alric's collaboration.

Top Co-Authors

Avatar

Ludovic Canaud

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

C. Marty-Ané

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Michel Batt

University of Nice Sophia Antipolis

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

P. Branchereau

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge