Featured researches published by Piers MacNaughton.
Environmental Health Perspectives | 2015
Joseph G. Allen; Piers MacNaughton; Usha Satish; Suresh Santanam; Jose Vallarino; John D. Spengler
Background: The indoor built environment plays a critical role in our overall well-being because of both the amount of time we spend indoors (~90%) and the ability of buildings to positively or negatively influence our health. The advent of sustainable design or green building strategies reinvigorated questions regarding the specific factors in buildings that lead to optimized conditions for health and productivity. Objective: We simulated indoor environmental quality (IEQ) conditions in “Green” and “Conventional” buildings and evaluated the impacts on an objective measure of human performance: higher-order cognitive function. Methods: Twenty-four participants spent 6 full work days (0900–1700 hours) in an environmentally controlled office space, blinded to test conditions. On different days, they were exposed to IEQ conditions representative of Conventional [high concentrations of volatile organic compounds (VOCs)] and Green (low concentrations of VOCs) office buildings in the United States. Additional conditions simulated a Green building with a high outdoor air ventilation rate (labeled Green+) and artificially elevated carbon dioxide (CO2) levels independent of ventilation. Results: On average, cognitive scores were 61% higher on the Green building day and 101% higher on the two Green+ building days than on the Conventional building day (p < 0.0001). VOCs and CO2 were independently associated with cognitive scores. Conclusions: Cognitive function scores were significantly better under Green+ building conditions than in the Conventional building conditions for all nine functional domains. These findings have wide-ranging implications because this study was designed to reflect conditions that are commonly encountered every day in many indoor environments. Citation: Allen JG, MacNaughton P, Satish U, Santanam S, Vallarino J, Spengler JD. 2016. Associations of cognitive function scores with carbon dioxide, ventilation, and volatile organic compound exposures in office workers: a controlled exposure study of green and conventional office environments. Environ Health Perspect 124:805–812; http://dx.doi.org/10.1289/ehp.1510037
Environmental Health Perspectives | 2015
Joseph G. Allen; Skye S. Flanigan; Mallory LeBlanc; Jose Vallarino; Piers MacNaughton; James H. Stewart; David C. Christiani
Background: There are > 7,000 e-cigarette flavors currently marketed. Flavoring chemicals gained notoriety in the early 2000s when inhalation exposure of the flavoring chemical diacetyl was found to be associated with a disease that became known as “popcorn lung.” There has been limited research on flavoring chemicals in e-cigarettes. Objective: We aimed to determine if the flavoring chemical diacetyl and two other high-priority flavoring chemicals, 2,3-pentanedione and acetoin, are present in a convenience sample of flavored e-cigarettes. Methods: We selected 51 types of flavored e-cigarettes sold by leading e-cigarette brands and flavors we deemed were appealing to youth. E-cigarette contents were fully discharged and the air stream was captured and analyzed for total mass of diacetyl, 2,3-pentanedione, and acetoin, according to OSHA method 1012. Results: At least one flavoring chemical was detected in 47 of 51 unique flavors tested. Diacetyl was detected above the laboratory limit of detection in 39 of the 51 flavors tested, ranging from below the limit of quantification to 239 μg/e-cigarette. 2,3-Pentanedione and acetoin were detected in 23 and 46 of the 51 flavors tested at concentrations up to 64 and 529 μg/e-cigarette, respectively. Conclusion: Because of the associations between diacetyl and bronchiolitis obliterans and other severe respiratory diseases observed in workers, urgent action is recommended to further evaluate this potentially widespread exposure via flavored e-cigarettes. Citation: Allen JG, Flanigan SS, LeBlanc M, Vallarino J, MacNaughton P, Stewart JH, Christiani DC. 2016. Flavoring chemicals in e-cigarettes: diacetyl, 2,3-pentanedione, and acetoin in a sample of 51 products, including fruit-, candy-, and cocktail-flavored e-cigarettes. Environ Health Perspect 124:733–739; http://dx.doi.org/10.1289/ehp.1510185
Environmental Health Perspectives | 2016
Joseph G. Allen; Skye S. Flanigan; Mallory LeBlanc; Jose Vallarino; Piers MacNaughton; James H. Stewart; David C. Christiani
We appreciate the opportunity to respond to the letter to the editor from Pierce et al. Nowhere do Pierce et al. identify any factual errors in our work; our key findings stand. We will, however, take this opportunity to address several of the points they raised. In their analysis comparing diacetyl in e-cigs to occupational exposure limits (OELs), Pierce et al. selectively chose to evaluate only the median (6.0 µg/e-cigarette for diacetyl and 1.6 µg/e-cigarette for 2,3-pentanedione) from our data to reinforce their point that exposures are below the OEL they derived (176 μg/day for diacetyl). In choosing only the median, Pierce et al. ignored that our study found, in a sample of only 51 of over 7,000 flavors, a flavored e-cigarette with a diacetyl concentration of 238 µg/e-cigarette, which exceeds the 176 µg/day OEL they calculated. There is additional support in the literature showing the potential to exceed their derived OEL, as well, including a paper cited by Pierce et al. Farsalinos et al. (2015) measured diacetyl directly in the liquid of e-cigarettes and then used this to estimate a daily dose (median = 6 μg/day; interquartile range: 26–278 μg/day). The 75th percentile concentration in Farsalinos et al. (2015) exceeds the daily dose limit of 176 µg/day that Pierce et al. used. Therefore, at least 25% of flavored e-cigarettes samples in the Farsalinos et al. (2015) paper would exceed the 176 µg/day limit derived by Pierce et al. We also want to reiterate our position, stated clearly in the discussion section of our paper along with our rationale, that the use of OELs for this population is inappropriate. Our position is in agreement with NIOSH, which published a response to the paper by Farsalinos et al. (2015) in which they stated that OELS are “…not intended to establish “safe” exposure concentrations for consumers or the general public” (Hubbs et al., 2015). Pierce et al. also misrepresent the findings of their own earlier work (Gaffney et al. 2015; Pierce et al. 2014; Pierce et al. 2015) in which diacetyl and 2,3-pentanedione levels were measured. In their letter they stated that “Over the past five years, we have published the results of several studies in which diacetyl and 2,3-pentanedione levels were measured in various consumer products.” As evident by the dates in the in-line citation, all 3 of their papers cited were published within 1.5 years; they do not have a 5-year record of publishing on this topic. Further, the ‘various consumer products’ include only 2 products: cigarettes and coffee. Additionally, in their letter they directly contradict the conclusions in their earlier work. In this letter they state “Gaffney et al. (2015) and Pierce et al. (2015) found that grinding, brewing, and consuming unflavored coffee was associated with airborne diacetyl concentrations that were several times higher than the NIOSH and ACGIH short-term (0.025 and 0.020 ppm, respectively) and 8-hour (0.005 and 0.010 ppm, respectively) OELs for diacetyl.” This is inaccurate and inconsistent with their own paper published in 2015. For workers brewing coffee, they actually state the exact opposite in the Pierce et al. (2015) paper: “None of the individual short-term (15 min) barista samples (maximum of 0.01 ppm) exceeded the proposed NIOSH or ACGIH STELs (0.025 ppm and 0.02 ppm, respectively).” And for customers consuming unflavored coffee, the maximum 8-hour exposure reported in their simulation (0.005 ppm; Table 2) was below the ACGIH 8-hour limit (0.010 ppm), and it was at the NIOSH recommended exposure limit (0.005 ppm), not above it, and certainly not “several times higher” than either limit (Pierce et al. 2015). We further note that Pierce et al. (2015) and Gaffney et al. (2014) appear not to have been peer reviewed, based on the short time between submission and publication (received, revised and accepted all in 3 and 1 days, respectively). Also, the 2 papers are on the same topic, were received by the same journal within 2 days of each other, and contain 6 identical and 12 nearly identical sentences, although only 1 discloses the funding source as being from two companies involved in diacetyl litigation. Furthermore, the exposure data reported in Pierce et al. (2015) were collected not in a coffee shop but in a small kitchen with a very low ventilation rate that we calculate to be well below the ASHRAE minimum ventilation rates for cafeterias/fast food dining of 19 ft3/min/person (ASHRAE 2013). Pierce et al. attempt to minimize risks by comparing flavored e-cigarettes and coffee beans, commenting, “Unless one assumes that unflavored coffee beans pose a serious risk of ‘popcorn lung,’ a rare and oftentimes lethal disease, then one should agree that exposures to airborne diketone levels above the NIOSH and ACGIH OELs are not necessarily indicative of respiratory risk.” They do not seem to be aware that, in fact, several workers at a coffee processing workplace were recently diagnosed with bronchiolitis obliterans (“popcorn lung”), and NIOSH’s investigation found a 2.7-fold elevated standard mortality ratio for obstruction for workers at this site (Bailey et al. 2015). The NIOSH investigation concluded that, “The exposure group working in both coffee flavoring and grinding/packaging of unflavored coffee areas had significantly lower mean ratio of forced expiratory volume in 1 s to forced vital capacity and percent predicted mid-expiratory flow than workers without such exposure,” and “Current workers have occupational lung morbidity associated with high diacetyl and 2,3-pentanedione exposures, which were not limited to flavoring areas.” Finally, Pierce et al.’s comparison of diketone exposures from e-cigarettes and cigarettes, and their assertion of an increase in diketone exposure by not switching to e-cigarettes, misses a major point. Nearly 2 million children have tried e-cigarettes, 160,000 of whom reported that they had not used cigarettes (CDC 2013). Pierce et al. stated, “Ironically, suggesting that diketone levels in e-cigarettes are potentially dangerous could actually lead to higher diketone exposures in the smoking population if smokers decide not to switch to e-cigarettes due to as yet unfounded health concerns.” What about the 160,000 children who tried e-cigarettes who had not used cigarettes? We see no irony. In conclusion, we stand by our work and the facts presented in our paper: diacetyl and other flavoring chemicals are in many flavored e-cigarettes, including flavors, like cupcake and cotton candy, that we deem are particularly appealing to kids. Considering the history of severe and irreversible lung disease associated with some workers who inhaled diacetyl, and the similar exposure pathways for consumers of flavored e-cigarettes, it is prudent to evaluate this potential hazard further, restrict access by youth, and provide consumers with information and warnings similar to those given to workers.
Current Environmental Health Reports | 2015
Joseph G. Allen; Piers MacNaughton; Jose Guillermo Cedeno Laurent; Skye S. Flanigan; Erika Sita Eitland; John D. Spengler
Green building design is becoming broadly adopted, with one green building standard reporting over 3.5 billion square feet certified to date. By definition, green buildings focus on minimizing impacts to the environment through reductions in energy usage, water usage, and minimizing environmental disturbances from the building site. Also by definition, but perhaps less widely recognized, green buildings aim to improve human health through design of healthy indoor environments. The benefits related to reduced energy and water consumption are well-documented, but the potential human health benefits of green buildings are only recently being investigated. The objective of our review was to examine the state of evidence on green building design as it specifically relates to indoor environmental quality and human health. Overall, the initial scientific evidence indicates better indoor environmental quality in green buildings versus non-green buildings, with direct benefits to human health for occupants of those buildings. A limitation of much of the research to date is the reliance on indirect, lagging and subjective measures of health. To address this, we propose a framework for identifying direct, objective and leading “Health Performance Indicators” for use in future studies of buildings and health.
American Journal of Public Health | 2015
Meryl D. Colton; Jose Guillermo Cedeno Laurent; Piers MacNaughton; John Kane; Mae Bennett-Fripp; John D. Spengler; Gary Adamkiewicz
OBJECTIVES We examined associations of several health outcomes with green and conventional low-income housing, where the prevalence of morbidities and environmental pollutants is elevated. METHODS We used questionnaires and a visual inspection to compare sick building syndrome (SBS) symptoms and asthma-related morbidity among residents in multifamily units in Boston, Massachusetts, between March 2012 and May 2013. Follow-up was approximately 1 year later. RESULTS Adults living in green units reported 1.35 (95% confidence interval [CI] = 0.66, 2.05) fewer SBS symptoms than those living in conventional (control) homes (P < .001). Furthermore, asthmatic children living in green homes experienced substantially lower risk of asthma symptoms (odds ratio [OR] = 0.34; 95% CI = 0.12, 1.00), asthma attacks (OR = 0.31; 95% CI = 0.11, 0.88), hospital visits (OR = 0.24; 95% CI = 0.06, 0.88), and asthma-related school absences (OR = 0.21; 95% CI = 0.06, 0.74) than children living in conventional public housing. CONCLUSIONS Participants living in green homes had improved health outcomes, which remained consistent over the study period. Green housing may provide a significant value in resource-poor settings where green construction or renovation could simultaneously reduce harmful indoor exposures, promote resident health, and reduce operational costs.
International Journal of Environmental Research and Public Health | 2015
Piers MacNaughton; James Pegues; Usha Satish; Suresh Santanam; John D. Spengler; Joseph G. Allen
Introduction: Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption—Economic and environmental costs. Methods: We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Results: Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than
Science of The Total Environment | 2016
Piers MacNaughton; Gary Adamkiewicz; Raphael E. Arku; Jose Vallarino; Douglas E. Levy
40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8%, equivalent to a
Journal of Exposure Science and Environmental Epidemiology | 2014
Chih-Da Wu; Piers MacNaughton; Steve Melly; Kevin Lane; Gary Adamkiewicz; John L. Durant; Doug Brugge; John D. Spengler
6500 increase in employee productivity each year. Reduced absenteeism and improved health are also seen with enhanced ventilation. Conclusions: The health benefits associated with enhanced ventilation rates far exceed the per-person energy costs relative to salary costs. Environmental impacts can be mitigated at regional, building, and individual-level scales through the transition to renewable energy sources, adoption of energy efficient systems and ventilation strategies, and promotion of other sustainable policies.
International Journal of Environmental Research and Public Health | 2017
Piers MacNaughton; Erika Sita Eitland; Itai Kloog; Joel Schwartz; Joseph P. Allen
BACKGROUND Smoke-free housing policies have the potential to reduce secondhand smoke (SHS) exposures for residents of multi-unit housing. Since common areas represent a pathway of SHS movement between units, smoke-free policies would be expected to reduce SHS in these microenvironments. METHODS Week-long air nicotine and PM2.5 (particulate matter below 2.5μm in aerodynamic diameter) samples were collected in the common areas of 10 Boston Housing Authority (BHA) and 6 Cambridge Housing Authority (CHA) buildings from January 2012 to October 2013. We also measured one outdoor PM level at each study building. Samples from BHA included pre and post- smoke-free policy measurements. Each development was visited three times over the course of the study period. The effect of the smoking ban on indoor PM2.5 was examined using generalized mixed effect models to accommodate repeated measurement at each site. Changes in nicotine concentrations were modeled using quantile mixed regression to reduce the impact of outliers. RESULTS After controlling for season, site, and background PM2.5 concentrations, PM2.5 levels were 4.05μg/m(3) (p-value=0.09) lower in BHA after the smoke-free policy was implemented in the summer of 2012, compared with CHA developments, which had no smoking policy in place. Similarly, nicotine levels decreased by 57% (p-value=0.08) in Boston relative to Cambridge after the ban. CONCLUSIONS Our findings support the use of smoke-free policies as an effective tool to reduce SHS exposure and protect non-smokers, especially residents of multi-unit housing.
International Journal of Environmental Research and Public Health | 2018
Xiaodong Cao; Piers MacNaughton; Zhengyi Deng; Jie Yin; Xi Zhang; Joseph G. Allen
Owing to data collection challenges, the vertical variation in population in cities and particulate air pollution are typically not accounted for in exposure assessments, which may lead to misclassification of exposures based on elevation of residency. To better assess this misclassification, the vertical distribution of the potentially highly exposed population (PHEP), defined as all residents within the 100-m buffer zone of above-ground highways or the 200-m buffer zone of a highway-tunnel exit, was estimated for four floor categories in Boston’s Chinatown (MA, USA) using the three-dimensional digital geography methodology. Vertical profiles of particle number concentration (7–3000 nm; PNC) and particulate matter (PM2.5) mass concentration were measured by hoisting instruments up the vertical face of an 11-story (35-m) building near the study area throughout the day on multiple days. The concentrations from all the profiles (n=23) were averaged together for each floor category. As measurement elevation increased from 0 to 35 m PNC decreased by 7.7%, compared with 3.6% for PM2.5. PHEP was multiplied by the average PNC for each floor category to assess exposures for near-highway populations. The results show that adding temporally-averaged vertical air pollution data had a small effect on residential ambient exposures for our study population; however, greater effects were observed when individual days were considered (e.g., winds were off the highways).