Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Pieter C. Smits is active.

Publication


Featured researches published by Pieter C. Smits.


The Lancet | 2012

Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis

Tullio Palmerini; Giuseppe Biondi-Zoccai; Diego Della Riva; Christoph Stettler; Diego Sangiorgi; Fabrizio D'Ascenzo; Takeshi Kimura; Carlo Briguori; Manel Sabaté; Hyo-Soo Kim; Antoinette de Waha; Elvin Kedhi; Pieter C. Smits; Christoph Kaiser; Gennaro Sardella; Antonino G.M. Marullo; Ajay J. Kirtane; Martin B. Leon; Gregg W. Stone

BACKGROUND The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. METHODS For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. FINDINGS 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare-metal stents at 2-year follow-up. INTERPRETATION In randomised studies completed to date, CoCr-EES has the lowest rate of stent thrombosis within 2 years of implantation. The finding that CoCr-EES also reduced stent thrombosis compared with bare-metal stents, if confirmed in future randomised trials, represents a paradigm shift. FUNDING The Cardiovascular Research Foundation.


The Lancet | 2010

Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial

Elvin Kedhi; Kaiyum Sheik Joesoef; Eugene McFadden; Jochem Wassing; Carlos Van Mieghem; Dick Goedhart; Pieter C. Smits

BACKGROUND Everolimus-eluting and paclitaxel-eluting stents, compared with bare metal stents, reduced the risk of restenosis in clinical trials with strict inclusion and exclusion criteria. We compared the safety and efficacy of the second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice. METHODS We randomly assigned 1800 consecutive patients (aged 18-85 years) undergoing percutaneous coronary intervention at one centre to treatment with everolimus-eluting or paclitaxel-eluting stents. The primary endpoint was a composite of safety and efficacy (all-cause mortality, myocardial infarction, and target vessel revascularisation) within 12 months. Patients were not told which stent they had been allocated. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01016041. FINDINGS Follow-up was completed in 1797 patients. The primary endpoint occurred in 56 (6%) of 897 patients in the everolimus-eluting stent group versus 82 (9%) of 903 in the paclitaxel-eluting stent group (relative risk 0.69 [95% CI 0.50-0.95], p value for superiority=0.02). The difference was attributable to a lower rate of stent thrombosis (6 [<1%] vs 23 [3%], 0.26 [0.11-0-64], p=0.002), myocardial infarction (25 [3%] vs 48 [5%], 0.52 [0.33-0.84], p=0.007), and target vessel revascularisation (21 [2%] vs 54 [6%], 0.39 [0.24-0.64], p=0.0001). Cardiac death, non-fatal myocardial infarction, or target lesion revascularisation occurred in 44 [5%] patients in the everolimus-eluting stent group versus 74 [8%] patients in the paclitaxel-eluting stent group, p value for superiority was 0.005. INTERPRETATION The everolimus-eluting stent is better than the second generation paclitaxel-eluting stent in unselected patients in terms of safety and efficacy. On the basis of our results, we suggest that paclitaxel-eluting stents should no longer be used in everyday clinical practice. FUNDING Unrestricted grants from Abbott Vascular and Boston Scientific.


Circulation | 2004

Unrestricted Utilization of Sirolimus-Eluting Stents Compared With Conventional Bare Stent Implantation in the “Real World” The Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) Registry

Pedro A. Lemos; Patrick W. Serruys; Ron T. van Domburg; Francesco Saia; Chourmouzios A. Arampatzis; Angela Hoye; Muzaffer Degertekin; Kengo Tanabe; Joost Daemen; Tommy K.K. Liu; Eugene McFadden; Georgios Sianos; Sjoerd H. Hofma; Pieter C. Smits; Willem J. van der Giessen; Pim J. de Feyter

Background—The effectiveness of sirolimus-eluting stents in unselected patients treated in the daily practice is currently unknown. Methods and Results—Sirolimus-eluting stent implantation has been used as the default strategy for all percutaneous procedures in our hospital as part of the R apamycin-E luting S tent E valuated A t R otterdam C ardiology H ospital (RESEARCH) registry. Consecutive patients with de novo lesions (n=508) treated exclusively with sirolimus-eluting stents (SES group) were compared with 450 patients who received bare stents in the period just before (pre-SES group). Patients in the SES group more frequently had multivessel disease, more type C lesions, received more stents, and had more bifurcation stenting. At 1 year, the cumulative rate of major adverse cardiac events (death, myocardial infarction, or target vessel revascularization) was 9.7% in the SES group and 14.8% in the pre-SES group (hazard ratio [HR], 0.62 [95% CI, 0.44 to 0.89]; P =0.008). The 1-year risk of clinically driven target vessel revascularization in the SES group and in the pre-SES group was 3.7% versus 10.9%, respectively (HR, 0.35 [95% CI, 0.21 to 0.57]; P <0.001). Conclusions—Unrestricted utilization of sirolimus-eluting stents in the “real world” is safe and effective in reducing both repeat revascularization and major adverse cardiac events at 1 year compared with bare stent implantation.


Journal of the American College of Cardiology | 2010

Evaluation of the Second Generation of a Bioresorbable Everolimus Drug-Eluting Vascular Scaffold for Treatment of De Novo Coronary Artery Stenosis Six-Month Clinical and Imaging Outcomes

Patrick W. Serruys; Yoshinobu Onuma; John A. Ormiston; Bernard De Bruyne; Evelyn Regar; Dariusz Dudek; Leif Thuesen; Pieter C. Smits; Bernard Chevalier; Dougal McClean; Jacques J. Koolen; Stephan Windecker; Robert Whitbourn; Ian T. Meredith; Cecile Dorange; Susan Veldhof; Karine Miquel-Hebert; Richard Rapoza; Hector M. Garcia-Garcia

OBJECTIVES The aim of this study was to demonstrate that the prevention of early scaffold area shrinkage of the ABSORB BVS (Rev.1.1, Abbott Vascular, Santa Clara, California) was sustained and not simply delayed by a few months. BACKGROUND With improved scaffold design and modified manufacturing process of its polymer, the second iteration of ABSORB (BVS 1.1) has improved performance to prevent a scaffold area reduction at 6 months. METHODS Fifty-six patients were enrolled and received 57 ABSORB scaffolds. Quantitative coronary angiography, intravascular ultrasound (IVUS), analysis of radiofrequency backscattering, echogenicity and optical coherence tomography (OCT) were performed at baseline and at 12-month follow-up. RESULTS Overall the scaffold area remained unchanged with IVUS as well as with OCT, whereas the radiofrequency backscattering and the echogenicity of the struts decreased by 16.8% (p < 0.001) and 20% (p < 0.001), respectively; more specifically, the strut core area on OCT decreased by 11.4% (p = 0.003). Despite the absence of scaffold area loss, pharmacological vasomotion was restored. On an intention-to-treat basis, the angiographic late lumen loss amounted to 0.27 ± 0.32 mm with an IVUS relative decrease in minimal lumen area of 1.94% (p = 0.12), without significant changes in mean lumen area. The OCT at follow-up showed that 96.69% of the struts were covered and that malapposition, initially observed in 18 scaffolds was only detected at follow-up in 4 scaffolds. Two patients experienced peri-procedural and iatrogenic myocardial infarction, respectively, whereas 2 underwent repeat intervention, resulting in the major adverse cardiac event rate of 7.1% (4 of 56). CONCLUSIONS The 12-month performance of the second-generation ABSORB bioresorbable everolimus-eluting scaffold justifies the conduct of a randomized trial against current best standards. (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System [BVS EECSS] in the Treatment of Patients With de Novo Native Coronary Artery Lesions; NCT00856856).


Circulation | 2003

TAXUS III Trial In-Stent Restenosis Treated With Stent-Based Delivery of Paclitaxel Incorporated in a Slow-Release Polymer Formulation

Kengo Tanabe; Patrick W. Serruys; Eberhard Grube; Pieter C. Smits; Guido Selbach; Willem J. van der Giessen; Manfred Staberock; Pim J. de Feyter; Ralf Müller; Evelyn Regar; Muzaffer Degertekin; Jurgen Ligthart; Clemens Disco; Bianca Backx; Mary E. Russell

Background—The first clinical study of paclitaxel-eluting stent for de novo lesions showed promising results. We performed the TAXUS III trial to evaluate the feasibility and safety of paclitaxel-eluting stent for the treatment of in-stent restenosis (ISR). Methods and Results—The TAXUS III trial was a single-arm, 2-center study that enrolled 28 patients with ISR meeting the criteria of lesion length ≤30 mm, 50% to 99% diameter stenosis, and vessel diameter 3.0 to 3.5 mm. They were treated with one or more TAXUS NIRx paclitaxel-eluting stents. Twenty-five patients completed the angiographic follow-up at 6 months, and 17 of these underwent intravascular ultrasound (IVUS) examination. No subacute stent thrombosis occurred up to 12 months, but there was one late chronic total occlusion, and additional 3 patients showed angiographic restenosis. The mean late loss was 0.54 mm, with neointimal hyperplasia volume of 20.3 mm3. The major adverse cardiac event rate was 29% (8 patients; 1 non-Q-wave myocardial infarction, 1 coronary artery bypass grafting, and 6 target lesion revascularization [TLR]). Of the patients with TLR, 1 had restenosis in a bare stent implanted for edge dissection and 2 had restenosis in a gap between 2 paclitaxel-eluting stents. Two patients without angiographic restenosis underwent TLR as a result of the IVUS assessment at follow-up (1 incomplete apposition and 1 insufficient expansion of the stent). Conclusions—Paclitaxel-eluting stent implantation is considered safe and potentially efficacious in the treatment of ISR. IVUS guidance to ensure good stent deployment with complete coverage of target lesion may reduce reintervention.


Circulation | 2005

Short- and Long-Term Clinical Outcome After Drug-Eluting Stent Implantation for the Percutaneous Treatment of Left Main Coronary Artery Disease Insights From the Rapamycin-Eluting and Taxus Stent Evaluated At Rotterdam Cardiology Hospital Registries (RESEARCH and T-SEARCH)

Marco Valgimigli; Carlos Van Mieghem; Andrew T.L. Ong; Jiro Aoki; Gaston A. Rodriguez Granillo; Eugene McFadden; Arie Pieter Kappetein; Pim J. de Feyter; Pieter C. Smits; Evelyn Regar; Willem J. van der Giessen; George Sianos; Peter de Jaegere; Ron T. van Domburg; Patrick W. Serruys

Background—The impact of drug-eluting stent (DES) implantation on the incidence of major adverse cardiovascular events in patients undergoing percutaneous intervention for left main (LM) coronary disease is largely unknown. Methods and Results—From April 2001 to December 2003, 181 patients underwent percutaneous coronary intervention for LM stenosis at our institution. The first cohort consisted of 86 patients (19 protected LM) treated with bare metal stents (pre-DES group); the second cohort comprised 95 patients (15 protected LM) treated exclusively with DES. The 2 cohorts were well balanced for all baseline characteristics. At a median follow-up of 503 days (range, 331 to 873 days), the cumulative incidence of major adverse cardiovascular events was lower in the DES cohort than in patients in the pre-DES group (24% versus 45%, respectively; hazard ratio [HR], 0.52 [95% CI, 0.31 to 0.88]; P=0.01). Total mortality did not differ between cohorts; however, there were significantly lower rates of both myocardial infarction (4% versus 12%, respectively; HR, 0.22 [95% CI, 0.07 to 0.65]; P=0.006) and target vessel revascularization (6% versus 23%, respectively; HR, 0.26 [95% CI, 0.10 to 0.65]; P=0.004) in the DES group. On multivariate analysis, use of DES, Parsonnet classification, troponin elevation at entry, distal LM location, and reference vessel diameter were independent predictors of major adverse cardiovascular events. Conclusions—When percutaneous coronary intervention is undertaken at LM lesions, routine DES implantation, which reduces the cumulative incidence of myocardial infarction and the need for target vessel revascularization compared with bare metal stents, should currently be the preferred strategy.


Circulation | 2004

Clinical, Angiographic, and Procedural Predictors of Angiographic Restenosis After Sirolimus-Eluting Stent Implantation in Complex Patients An Evaluation From the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) Study

Pedro A. Lemos; Angela Hoye; Dick Goedhart; Chourmouzios A. Arampatzis; Francesco Saia; Willem J. van der Giessen; Eugene McFadden; Georgios Sianos; Pieter C. Smits; Sjoerd H. Hofma; Pim J. de Feyter; Ron T. van Domburg; Patrick W. Serruys

Background—The factors associated with the occurrence of restenosis after sirolimus-eluting stent (SES) implantation in complex cases are currently unknown. Methods and Results—A cohort of consecutive complex patients treated with SES implantation was selected according to the following criteria: (1) treatment of acute myocardial infarction, (2) treatment of in-stent restenosis, (3) 2.25-mm diameter SES, (4) left main coronary stenting, (5) chronic total occlusion, (6) stented segment >36 mm, and (7) bifurcation stenting. The present study population was composed of 238 patients (441 lesions) for whom 6-month angiographic follow-up data were obtained (70% of eligible patients). Significant clinical, angiographic, and procedural predictors of post-SES restenosis were evaluated. Binary in-segment restenosis was diagnosed in 7.9% of lesions (6.3% in-stent, 0.9% at the proximal edge, 0.7% at the distal edge). The following characteristics were identified as independent multivariate predictors: treatment of in-stent restenosis (OR 4.16, 95% CI 1.63 to 11.01; P <0.01), ostial location (OR 4.84, 95% CI 1.81 to 12.07; P <0.01), diabetes (OR 2.63, 95% CI 1.14 to 6.31; P =0.02), total stented length (per 10-mm increase; OR 1.42, 95% CI 1.21 to 1.68; P <0.01), reference diameter (per 1.0-mm increase; OR 0.46, 95% CI 0.24 to 0.87; P =0.03), and left anterior descending artery (OR 0.30, 95% CI 0.10 to 0.69; P <0.01). Conclusions—Angiographic restenosis after SES implantation in complex patients is an infrequent event, occurring mainly in association with lesion-based characteristics and diabetes mellitus.


Circulation | 2003

Coronary Restenosis After Sirolimus-Eluting Stent Implantation Morphological Description and Mechanistic Analysis From a Consecutive Series of Cases

Pedro A. Lemos; Francesco Saia; Jurgen Ligthart; Chourmouzios A. Arampatzis; Georgios Sianos; Kengo Tanabe; Angela Hoye; Muzaffer Degertekin; Joost Daemen; Eugene McFadden; Sjoerd H. Hofma; Pieter C. Smits; Pim J. de Feyter; Willem J. van der Giessen; Ron T. van Domburg; Patrick W. Serruys

Background We describe the clinical and morphological patterns of restenosis after sirolimus‐eluting stent (SES) implantation. Methods and Results From 121 patients with coronary angiography obtained >30 days after SES implantation, restenosis (diameter stenosis >50%) was identified in 19 patients and 20 lesions (located at the proximal 5‐mm segment in 30% or within the stent in 70%). Residual dissection after the procedure or balloon trauma outside the stent was identified in 83% of the proximal edge lesions. Lesions within the stent were focal, and stent discontinuity was identified in some lesions evaluated by intravascular ultrasound. Conclusions Sirolimus‐eluting stent edge restenosis is frequently associated with local trauma outside the stent. In‐stent restenosis occurs as a localized lesion, commonly associated with a discontinuity in stent coverage. Local conditions instead of intrinsic drug‐resistance to sirolimus are likely to play a major role in post‐SES restenosis. (Circulation. 2003; 108:257‐260.)


Journal of the American College of Cardiology | 2003

Sirolimus-eluting stent for treatment of complex in-stent restenosis: the first clinical experience.

Muzaffer Degertekin; Evelyn Regar; Kengo Tanabe; Pieter C. Smits; Willem J. van der Giessen; S.G. Carlier; Pim J. de Feyter; Jeroen Vos; David P. Foley; Jurgen Ligthart; Jeffrey J. Popma; Patrick W. Serruys

OBJECTIVES In this study, we assess the value of sirolimus eluting stent (SES) implantation in patients with complex in-stent restenosis (ISR). BACKGROUND The treatment of ISR remains a therapeutic challenge, since many pharmacological and mechanical approaches have shown disappointing results. The SESs have been reported to be effective in de-novo coronary lesions. METHODS Sixteen patients with severe, recurrent ISR in a native coronary artery (average lesion length 18.4 mm) and objective evidence of ischemia were included. They received one or more 18 mm Bx VELOCITY SESs (Cordis Waterloo, Belgium). Quantitative angiographic and three-dimensional intravascular ultrasound (IVUS) follow-up was performed at four months, and clinical follow-up at nine months. RESULTS The SES implantation (n = 26) was successful in all 16 patients. Four patients had recurrent restenosis following brachytherapy, and three patients had totally occluded vessels preprocedure. At four months follow-up, one patient had died and three patients had angiographic evidence of restenosis (one in-stent and two in-lesion). In-stent late lumen loss averaged 0.21 mm and the volume obstruction of the stent by IVUS was 1.1%. At nine months clinical follow-up, three patients had experienced four major adverse cardiac events (two deaths and one acute myocardial infarction necessitating repeat target vessel angioplasty). CONCLUSIONS The SES implantation in patients with severe ISR lesions effectively prevents neointima formation and recurrent restenosis at four months angiographic follow-up.


Circulation | 2010

Evaluation of the Second Generation of a Bioresorbable Everolimus Drug-Eluting Vascular Scaffold for Treatment of De Novo Coronary Artery StenosisClinical Perspective

Patrick W. Serruys; Yoshinobu Onuma; John Ormiston; Bernard De Bruyne; Evelyn Regar; Dariusz Dudek; Leif Thuesen; Pieter C. Smits; Bernard Chevalier; Dougal McClean; Jacques J. Koolen; Stephan Windecker; Robert Whitbourn; Ian T. Meredith; Cecile Dorange; Susan Veldhof; Karine Miquel-Hebert; Richard Rapoza; Hector M. Garcia-Garcia

Background— The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified. Methods and Results— Quantitative coronary angiography, intravascular ultrasound with analysis of radiofrequency backscattering, and as an optional assessment, optical coherence tomography (OCT) were performed at baseline and at a 6-month follow-up. Forty-five patients successfully received a single bioresorbable everolimus drug-eluting vascular scaffold. One patient had postprocedural release of myocardial enzyme without Q-wave occurrence; 1 patient with OCT-diagnosed disruption of the scaffold caused by excessive postdilatation was treated 1 month later with a metallic drug-eluting stent. At follow-up, 3 patients declined recatheterization, 42 patients had quantitative coronary angiography, 37 had quantitative intravascular ultrasound, and 25 had OCT. Quantitative coronary angiography disclosed 1 edge restenosis (1 of 42; in-segment binary restenosis, 2.4%). At variance with the ultrasonic changes seen with the first generation of bioresorbable everolimus drug-eluting vascular scaffold at 6 months, the backscattering of the polymeric struts did not decrease over time, the scaffold area was reduced by only 2.0% with intravascular ultrasound, and no change was noted with OCT. On an intention-to-treat basis, the late lumen loss amounted to 0.19±0.18 mm with a limited relative decrease in minimal luminal area of 5.4% on intravascular ultrasound. OCT showed at follow-up that 96.8% of the struts were covered and that malapposition of at least 1 strut, initially observed in 12 scaffolds, was detected at follow-up in only 3 scaffolds. Mean neointimal growth measured by OCT between and on top of the polymeric struts equaled 1.25 mm2, or 16.6% of the scaffold area. Conclusion— Modified manufacturing process of the polymer and geometric changes in the polymeric platform have substantially improved the medium-term performance of this new generation of drug-eluting scaffold to become comparable to those of current drug eluting stents. Clinical Trial Registration— URL: http://clinicaltrials.gov. Unique identifier: NCT00856856.

Collaboration


Dive into the Pieter C. Smits's collaboration.

Top Co-Authors

Avatar

Patrick W. Serruys

University of Texas Health Science Center at Houston

View shared research outputs
Top Co-Authors

Avatar

Gregg W. Stone

NewYork–Presbyterian Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Pedro A. Lemos

University of São Paulo

View shared research outputs
Top Co-Authors

Avatar

Martin B. Leon

Columbia University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Pim J. de Feyter

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Ron T. van Domburg

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Eugene McFadden

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Sjoerd H. Hofma

Erasmus University Rotterdam

View shared research outputs
Researchain Logo
Decentralizing Knowledge