Ping-Hua Teng
Tunghai University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Ping-Hua Teng.
PLOS ONE | 2012
Yun-Long Tsai; Hwa-Tang Thomas Wang; Hsiao-Fen Grace Chang; Chuan-Fu Tsai; Ching-Ko Lin; Ping-Hua Teng; Chen Su; Chien-Chung Jeng; Pei-Yu Lee
Insulated isothermal PCR (iiPCR), established on the basis of Ralyeigh-Bénard convection, is a rapid and low-cost platform for nucleic acid amplification. However, the method used for signal detection, namely gel electrophoresis, has limited the application of iiPCR. In this study, TaqMan probe-based iiPCR system was developed to obviate the need of post-amplification processing. This system includes an optical detection module, which was designed and integrated into the iiPCR device to detect fluorescent signals generated by the probe. TaqMan probe-iiPCR assays targeting white spot syndrome virus (WSSV) and infectious myonecrosis virus were developed for preliminary evaluation of this system. Significant elevation of fluorescent signals was detected consistently among positive iiPCR reactions in both assays, correlating with amplicon detection by gel electrophoresis analysis. After condition optimization, a threshold value of S/N (fluorescent intensityafter/fluorescent intensitybefore) for positive reactions was defined for WSSV TaqMan probe-iiPCR on the basis of 20 blank reactions. WSSV TaqMan probe-iiPCR generated positive S/Ns from as low as 101 copies of standard DNA and lightly infected Litopenaeus vannamei. Compared with an OIE-certified nested PCR, WSSV TaqMan probe-iiPCR showed a sensitivity of 100% and a specificity of 96.67% in 120 WSSV-free or lightly infected shrimp samples. Generating positive signals specifically and sensitively, TaqMan probe-iiPCR system has a potential as a low-cost and rapid on-site diagnostics method.
Biotechnology Journal | 2012
Hsiao-Fen Grace Chang; Yun-Long Tsai; Chuan-Fu Tsai; Ching-Ko Lin; Pei-Yu Lee; Ping-Hua Teng; Chen Su; Chien-Chung Jeng
Rayleigh‐Bénard convective PCR is a simple and effective design for amplification of DNA. Convective PCR is, however, extremely sensitive to environmental temperature fluctuations, especially when using small‐ diameter test tubes. Therefore, this method is inherently unstable with limited applications. Here, we present a convective PCR device that has been modified by adding thermal baffles. With this thermally baffled device the influence from fluctuations in environmental temperature were significantly reduced, even in a wind tunnel (1 m/s). The thermally baffled PCR instrument described here has the potential to be used as a low‐cost, point‐of‐care device for PCR‐based molecular diagnostics in the field.
Journal of Virological Methods | 2011
Pin-Hsing Chou; Yu-Chan Lin; Ping-Hua Teng; Chu-Liang Chen; Pei-Yu Lee
Aiming to establish a target amplicon-specific detection system for loop-mediated isothermal amplification (LAMP), the fluorescent resonance energy transfer (FRET) probe technology was applied to develop the FRET LAMP platform. This report describes the development of the first FRET LAMP assay targeting white spot syndrome virus (WSSV) of penaeid shrimp. A successful accelerated WSSV LAMP was assembled first in a conventional oven and confirmed by gel electrophoresis and dot-blot hybridization. Subsequently, two additional FRET probes designed to target one loop region within WSSV LAMP amplicons were added to the same LAMP reaction. The reactions were carried out in a LightCycler (Roche) and significant FRET signals were detected in real time. Optimization of the reaction using plasmid DNA shortened the time for the detection of 10(2) copies of the target DNA to less than 70min. Cross reactivity was absent with WSSV-free or infectious hypodermal and hematopoietic necrosis virus-infected Penaeus vannamei samples. The performance of this system was comparable with that of a nested PCR assay from 21 WSSV-infected shrimp. Specifically detecting target amplicons and requiring no post-amplification manipulation, the novel FRET LAMP assay should allow indisputable detection of pathogens with minimized risks of amplicon contamination.
Journal of Virological Methods | 2012
Yun-Long Tsai; Yu-Chan Lin; Pin-Hsing Chou; Ping-Hua Teng; Pei-Yu Lee
Aiming to develop a rapid, low-cost, and user-friendly system for the diagnosis of white spot syndrome virus (WSSV), a PCR assay performed in capillary tubes under insulated isothermal conditions (iiPCR assay) was established on the basis of Rayleigh-Benard convection. WSSV amplicons were generated reproducibly within 30 min from a target sequence-containing plasmid in an iiPCR device, in which a special polycarbonate capillary tube (R-tube™) was heated isothermally by a copper ring attached to its bottom and shielded by a thermal baffle around its upper half. Furthermore, WSSV-specific amplicons were produced from nucleic acid extracts of WSSV-infected Penaeus vannamei in the WSSV iiPCR assay, with sensitivity comparable to that of an OIE-certified commercial nested PCR kit (IQ2000™ WSSV Detection and Prevention System). Specificity of the WSSV iiPCR assay was demonstrated as no amplicons were generated from shrimp genomic DNA, and IHHNV, MBV, and HPV DNA. iiPCR has a potential as a low-cost method for sensitive, specific and rapid detection of pathogens.
Journal of Virological Methods | 2007
Ping-Hua Teng; Chu-Liang Chen; Ping-Feng Sung; Fu-Chun Lee; Bor-Rung Ou; Pei-Yu Lee
Journal of Food Protection | 2013
Hau-Yang Tsen; Chia-Ming Shih; Ping-Hua Teng; Hsin-Yen Chen; Chia-Wei Lin; Chien-Shun Chiou; Hwa-Tang Thomas Wang; Hsiao-Fen Grace Chang; Te-Yu Chung; Pei-Yu Lee; Yu-Cheng Chiang
Diseases of Aquatic Organisms | 2006
Ping-Hua Teng; Pei-Yu Lee; Fu-Chun Lee; Hung-Wen Chien; Man-Shu Chen; Ping-Feng Sung; Chen Su; Bor-Rung Ou
Archive | 2011
Chen Su; Ping-Hua Teng; Chien-Chung Jeng
Archive | 2016
Chen Su; Ping-Hua Teng; Chien-Chung Jeng
Archive | 2012
Chen Su; 苏城; Ping-Hua Teng; 邓秉华; Chien-Chung Jeng; 郑建宗