Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Poornima Sood is active.

Publication


Featured researches published by Poornima Sood.


Journal of the American College of Cardiology | 2011

Randomized Comparison of Everolimus- and Paclitaxel-Eluting Stents: 2-Year Follow-Up From the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) IV Trial

Gregg W. Stone; Ali Rizvi; Krishnankutty Sudhir; William P. Newman; Robert J. Applegate; Louis Cannon; James T. Maddux; Donald E. Cutlip; Charles A. Simonton; Poornima Sood; Spirit Iv Investigators

OBJECTIVES We sought to determine whether the differences in outcomes present between everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES) in the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) IV trial at 1 year were sustained with longer-term follow-up. BACKGROUND In the SPIRIT IV trial, patients undergoing percutaneous coronary intervention who were randomized to EES compared with PES experienced lower 1-year rates of target lesion failure (cardiac death, target vessel myocardial infarction [MI], or ischemia-driven target lesion revascularization [TLR]), with significant reductions in the individual rates of MI, TLR, and stent thrombosis. METHODS We prospectively randomized 3,687 patients with up to 3 noncomplex previously untreated native coronary artery lesions to EES versus PES at 66 U.S. sites. Follow-up through 2 years is complete in 3,578 patents (97.0%). RESULTS Treatment with EES compared with PES reduced the 2-year rates of TLF (6.9% vs. 9.9%, p = 0.003), all MI (2.5% vs. 3.9%, p = 0.02), Q-wave MI (0.1% vs. 0.8%, p = 0.002), stent thrombosis (0.4% vs. 1.2%, p = 0.008), and ischemia-driven TLR (4.5% vs. 6.9%, p = 0.004), with nonsignificantly different rates of all-cause and cardiac mortality. Between 1 year and 2 years, there were no significant differences in adverse event rates between the 2 stent types. CONCLUSIONS In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, the benefits of EES compared with those of PES present at 1 year were sustained at 2 years.


Journal of the American College of Cardiology | 2015

Fully Magnetically Levitated Left Ventricular Assist System for Treating Advanced HF: A Multicenter Study

Ivan Netuka; Poornima Sood; Yuriy Pya; Daniel Zimpfer; Thomas Krabatsch; Jens Garbade; Vivek Rao; Michiel Morshuis; Silvana Marasco; Friedhelm Beyersdorf; Laura Damme; Jan D. Schmitto

BACKGROUND The HeartMate 3 left ventricular assist system (LVAS) is intended to provide long-term support to patients with advanced heart failure. The centrifugal flow pump is designed for enhanced hemocompatibility by incorporating a magnetically levitated rotor with wide blood-flow paths and an artificial pulse. OBJECTIVES The aim of this single-arm, prospective, multicenter study was to evaluate the performance and safety of this LVAS. METHODS The primary endpoint was 6-month survival compared with INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support)-derived performance goal. Patients were adults with ejection fraction ≤ 25%, cardiac index ≤ 2.2 l/min/m(2) without inotropes or were inotrope-dependent on optimal medical management, or listed for transplant. RESULTS Fifty patients were enrolled at 10 centers. The indications for LVAS support were bridge to transplantation (54%) or destination therapy (46%). At 6 months, 88% of patients continued on support, 4% received transplants, and 8% died. Thirty-day mortality was 2% and 6-month survival 92%, which exceeded the 88% performance goal. Support with the fully magnetically levitated LVAS significantly reduced mortality risk by 66% compared with the Seattle Heart Failure Model-predicted survival of 78% (p = 0.0093). Key adverse events included reoperation for bleeding (14%), driveline infection (10%), gastrointestinal bleeding (8%), and debilitating stroke (modified Rankin Score > 3) (8%). There were no pump exchanges, pump malfunctions, pump thrombosis, or hemolysis events. New York Heart Association classification, 6-min walk test, and quality-of-life scores showed progressive and sustained improvement. CONCLUSIONS The results show that the fully magnetically levitated centrifugal-flow chronic LVAS is safe, with high 30-day and 6-month survival rates, a favorable adverse event profile, and improved quality of life and functional status. (HeartMate 3™ CE Mark Clinical Investigation Plan [HM3 CE Mark]; NCT02170363).


Journal of the American College of Cardiology | 2010

Outcomes in diabetic and nondiabetic patients treated with everolimus- or paclitaxel-eluting stents: results from the SPIRIT IV clinical trial (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System).

Donald E. Cutlip; Robert J. Applegate; John C. Wang; Manejeh Yaqub; Poornima Sood; Xiaolu Su; Guoping Su; Naim Farhat; Ali Rizvi; Charles A. Simonton; Krishnankutty Sudhir; Gregg W. Stone

OBJECTIVES We compared the safety and efficacy of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) with the TAXUS Express (Boston Scientific, Natick, Massachusetts) paclitaxel-eluting stent (PES) among the large cohort of randomized diabetic patients enrolled in the SPIRIT IV (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) trial. BACKGROUND Diabetes mellitus remains a significant predictor of adverse clinical outcomes after percutaneous coronary intervention with drug-eluting stents, and the comparative outcomes of different drug-eluting stents in diabetic patients remains ill-defined. METHODS In the SPIRIT IV trial, 3,687 patients with up to 3 de novo native coronary artery lesions were prospectively randomized 2:1 to receive EES or PES. Randomization was stratified by the presence of diabetes and lesion complexity. The primary end point was the occurrence of target lesion failure (TLF) (cardiac death, target-vessel myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year. Clinical outcomes were evaluated in randomized diabetic (n = 1,185 [786 EES; 399 PES]) and nondiabetic patients (n = 2,498 [1,669 EES; 829 PES]). RESULTS The EES compared with PES reduced TLF in nondiabetic patients (3.1% vs. 6.7%, p < 0.0001), with significant reductions in myocardial infarction, stent thrombosis, and target lesion revascularization. In contrast, no difference in TLF (6.4% vs. 6.9%, respectively, p = 0.80) or any of its components was present among diabetic patients, regardless of insulin use. A significant interaction between the presence of diabetes and stent type on TLF (p(interaction) = 0.02) was observed. CONCLUSIONS In the SPIRIT IV randomized trial, EES compared with PES provided similar clinical outcomes in diabetic patients and superior clinical outcomes in nondiabetic patients at 1 year. (SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT00307047).


Coronary Artery Disease | 2010

Recent progress in percutaneous coronary intervention: evolution of the drug-eluting stents, focus on the XIENCE V drug-eluting stent.

Julie Doostzadeh; Lee N. Clark; Susan Bezenek; Wesley Pierson; Poornima Sood; Krishnankutty Sudhir

Although originally the practice of using balloon catheters proved successful in the short term, the long-term prognosis was less promising because of restenosis, which occurred in ≥30% of patients. This prompted the development of new techniques and mechanical adjuncts, or stents, to maintain lumen patency after balloon angioplasty. Bare metal stents (BMS), the first type of stent used in percutaneous coronary intervention, were designed to address the issues met by balloon angioplasty. BMS reduced the angiographic and clinical restenosis rates in de novo lesions compared to percutaneous transluminal coronary angioplasty alone and decreased the need for emergency coronary artery bypass graft surgery. BMS substantially reduced the incidence of abrupt artery closure, but restenosis still occurred after 6 months in about 20% of cases, necessitating repeat procedures. Drug-eluting stents (DES) improved on the principle of BMS by also delivering drugs locally to inhibit neointimal hyperplasia. DES greatly reduced the incidence of restenosis and resulted in a better safety profile as compared to radiation or systemic drug administration. These advantages and a lower cost compared to surgical interventions make DES an attractive option to treat coronary artery disease. Currently, five DES are available in the USA: the CYPHER sirolimus-eluting stent from Cordis (approved by FDA on 24 April 2003), the TAXUS Express2 and Liberté paclitaxel-eluting stents from Boston Scientific (approved by FDA on 4 March 2004 and 10 October 2008, respectively) (hereafter TAXUS Express is referred to as TAXUS), the ENDEAVOR zotarolimus-eluting stent from Medtronic (approved by FDA on 1 February 2008), and the XIENCE V everolimus-eluting stent from Abbott Vascular (approved by FDA on 2 July 2008). Following the approval of CYPHER and TAXUS, the clinical data suggested a potential small increase in the rate of stent thrombosis (ST) in DES compared with BMS after implantation. To determine the differences in ST and other rare events between different stents, some modifications have been made to DES clinical trial design, and postmarket surveillance programs have been included to further evaluate the safety and efficacy of each DES. In this review, we will discuss the key clinical outcomes of DES clinical trials, design and key features of the current coronary stents, and major clinical development programs. Postmarket trials, designed to establish long-term safety around ST and other rare clinical events, are also discussed. The future of DES design technologies will also be outlined.


Jacc-cardiovascular Interventions | 2011

Impact of Lesion Length and Vessel Size on Clinical Outcomes After Percutaneous Coronary Intervention With Everolimus- Versus Paclitaxel-Eluting Stents: Pooled Analysis From the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials

Bimmer E. Claessen; Pieter C. Smits; Helen Parise; Martin Fahy; Elvin Kedhi; Patrick W. Serruys; Alexandra J. Lansky; Ecaterina Cristea; Krishnankutty Sudhir; Poornima Sood; Charles A. Simonton; Gregg W. Stone

OBJECTIVES The aim of this study was to investigate the impact of reference vessel diameter (RVD) and lesion length (LL) on the relative safety and efficacy of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES). BACKGROUND Lesion length and RVD are well-known predictors of adverse events after percutaneous coronary intervention. METHODS Patient-level data were pooled from the randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) trials. Quantitative angiographic core laboratory data were available for 6,183 patients randomized to EES (n = 3,944) or PES (n = 2,239). Long lesions and small vessels were defined as LL >median (13.4 mm) and RVD ≤median (2.65 mm), respectively. Major adverse cardiac events (MACE) (consisting of cardiac death, myocardial infarction, or ischemia-driven target lesion revascularization) were assessed at 2 years, according to stent type in 3 groups: short lesions in large vessels (group A, n = 1,297); long lesions or small vessels but not both (group B, n = 2,981); and long lesions in small vessels (group C, n = 1,905). RESULTS The pooled 2-year MACE rates were 5.6%, 8.2%, and 10.4% in Groups A, B, and C, respectively (p < 0.0001). There was no significant interaction between lesion group and stent type (p = 0.64), indicating lower MACE with EES compared with PES regardless of LL and RVD. However, the absolute difference was largest in Groups B and C. In Group A, 2-year MACE rates were not significantly different between EES and PES (4.8% vs. 7.0%, respectively, p = 0.11). In contrast, EES was associated with lower 2-year rates of MACE in Group B (6.6% vs. 11.2%, p < 0.01) and in Group C (9.1% vs. 12.7%, p = 0.008) as well as lower rates of myocardial infarction, target lesion revascularization, and stent thrombosis. Multivariable analysis confirmed EES versus PES as an independent predictor of freedom from MACE in Groups B and C. CONCLUSIONS Patients with short lesions in large vessels have low rates of MACE at 2 years after treatment with either EES or PES. In higher-risk patients with long lesions and/or small vessels, EES results in significant improvements in both clinical safety and efficacy outcomes. (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT00180479; SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT00307047; A Randomized Controlled Trial of Everolimus-eluting Stents and Paclitaxel-eluting Stents for Coronary Revascularization in Daily Practice: The COMPARE Trial; NCT01016041).


Eurointervention | 2012

Stent thrombosis: insights on outcomes, predictors and impact of dual antiplatelet therapy interruption from the SPIRIT II, SPIRIT III, SPIRIT IV and COMPARE trials.

Elvin Kedhi; Gregg W. Stone; Patrick W. Serruys; Helen Parise; Martin Fahy; Charles A. Simonton; Krishnankutty Sudhir; Poornima Sood; Pieter C. Smits

AIMS Recent studies have suggested that EES may reduce ST compared to PES, but no individual trial has been adequately powered for this endpoint. The incidence of stent thrombosis, as well as the impact of dual antiplatelet therapy (DAPT) discontinuation during the first two years following everolimus-eluting stent (EES) and paclitaxel-eluting stent (PES) deployment were therefore analysed from a pooled, patient-level database derived from four randomised clinical trials. METHODS AND RESULTS Data from the SPIRIT II, SPIRIT III, SPIRIT IV and COMPARE trials (n=6,789 patients) were analysed. Two-year ST rates were determined using time-to-event methods and compared with the log-rank test. ST rates were also determined after DAPT discontinuation. EES compared to PES significantly reduced the two-year rates of ST (0.7% versus 2.3%, p=0.0001), including the interval rates of ST up to 30 days (0.2% versus 1.0%, p<0.0001), between 31 days and one year (0.2% versus 0.6%, p=0.02), and after one year (0.3% versus 0.8%, p=0.001). EES also reduced the two-year composite rate of cardiac death or MI (4.0% versus 6.6%, p=0.0001). Increased rates of ST after DAPT discontinuation beyond six months were observed in the PES cohort, but not in the EES cohort. CONCLUSION In this large pooled analysis from four randomised trials, treatment with EES compared to PES significantly reduced the rates of ST through two years of follow-up, with a concomitant reduction in cardiac death or MI. DAPT discontinuation beyond six months may be safe with EES.


Journal of Heart and Lung Transplantation | 2016

Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol

Gerald Heatley; Poornima Sood; D. Goldstein; Nir Uriel; Joseph C. Cleveland; Don Middlebrook; Mandeep R. Mehra

The HeartMate 3 left ventricular assist system (LVAS; St. Jude Medical, Inc., formerly Thoratec Corporation, Pleasanton, CA) was recently introduced into clinical trials for durable circulatory support in patients with medically refractory advanced-stage heart failure. This centrifugal, fully magnetically levitated, continuous-flow pump is engineered with the intent to enhance hemocompatibility and reduce shear stress on blood elements, while also possessing intrinsic pulsatility. Although bridge-to-transplant (BTT) and destination therapy (DT) are established dichotomous indications for durable left ventricular assist device (LVAD) support, clinical practice has challenged the appropriateness of these designations. The introduction of novel LVAD technology allows for the development of clinical trial designs to keep pace with current practices. The prospective, randomized Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) clinical trial aims to evaluate the safety and effectiveness of the HeartMate 3 LVAS by demonstrating non-inferiority to the HeartMate II LVAS (also St. Jude Medical, Inc.). The innovative trial design includes patients enrolled under a single inclusion and exclusion criteria , regardless of the intended use of the device, with outcomes ascertained in the short term (ST, at 6 months) and long term (LT, at 2 years). This adaptive trial design includes a pre-specified safety phase (n = 30) analysis. The ST cohort includes the first 294 patients and the LT cohort includes the first 366 patients for evaluation of the composite primary end-point of survival to transplant, recovery or LVAD support free of debilitating stroke (modified Rankin score >3), or re-operation to replace the pump. As part of the adaptive design, an analysis by an independent statistician will determine whether sample size adjustment is required at pre-specified times during the study. A further 662 patients will be enrolled to reach a total of 1,028 patients for evaluation of the secondary end-point of pump replacement at 2 years.


Journal of Heart and Lung Transplantation | 2016

Evaluation of von Willebrand factor with a fully magnetically levitated centrifugal continuous-flow left ventricular assist device in advanced heart failure

Ivan Netuka; Tomáš Kvasnička; Jan Kvasnička; Ingrid Hrachovinová; Peter Ivak; František Mareček; Jana Bílková; Ivana Malíková; Michaela Jančová; Jiří Malý; Poornima Sood; Kartik S. Sundareswaran; Jean M. Connors; Mandeep R. Mehra

BACKGROUND Contemporary continuous-flow left ventricular assist devices (CF-LVADs) are associated with degradation of von Willebrand factor (vWF) high-molecular-weight multimers (HMWMs), a critical factor supporting platelet function. We hypothesized that the HeartMate 3 fully magnetically levitated LVAD, designed to reduce circulatory shear stress, favorably influences these hemostatic parameters. METHODS Fifteen consecutive HeartMate 3 LVAD patients were compared with 11 consecutive HeartMate II controls. Serial plasma samples were collected pre-implant and on Days 2, 7, 30 and 45 post-operatively. Changes in vWF HMWMs were evaluated by 2 independent, study-blind hematologists and confirmed using densitometry-based computerized software. Ristocetin cofactor (RiCO) and vWF antigen (vWF Ag) were measured using standard protocols with enzyme-linked immunosorbent assay. RESULTS HeartMate 3 patients and HeartMate II controls had a mean age of 67.3 ± 1.4 and 52.8 ± 2.5 years, respectively (INTERMACS Profiles 2 to 4 in 93.3% and 91%, respectively). HeartMate 3 group demonstrated a significantly greater preservation of HMWMs compared with the HeartMate II group, with the most prominent decrease occurring by Day 2 post-operatively and sustained through 45 days (71.94% vs 31.16%, p = 0.001). Laboratory values (normalized to baseline) for RiCO activity, vWF Ag and RiCO:vWF Ag ratio remained in the functional range with no statistically significant differences observed between groups. CONCLUSION The HeartMate 3 LVAD is associated with enhanced hemocompatibility compared with the HeartMate II LVAD, as demonstrated by the improved preservation of vWF HMWMs, In contrast, effects on HMWM degradation appeared to be dissociated from functional attributes. Further confirmation of these findings in randomized clinical trials is warranted.


The New England Journal of Medicine | 2018

Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure

Mandeep R. Mehra; D. Goldstein; Nir Uriel; Joseph C. Cleveland; M. Yuzefpolskaya; Christopher T. Salerno; Mary Norine Walsh; Carmelo A. Milano; Chetan B. Patel; Gregory A. Ewald; Akinobu Itoh; David A. Dean; Arun Krishnamoorthy; William G. Cotts; Antone Tatooles; Ulrich P. Jorde; Brian A. Bruckner; Jerry D. Estep; Valluvan Jeevanandam; G. Sayer; Douglas A. Horstmanshof; James W. Long; Sanjeev K. Gulati; Eric R. Skipper; John B. O’Connell; Gerald Heatley; Poornima Sood; Yoshifumi Naka

Background In an early analysis of this trial, use of a magnetically levitated centrifugal continuous‐flow circulatory pump was found to improve clinical outcomes, as compared with a mechanical‐bearing axial continuous‐flow pump, at 6 months in patients with advanced heart failure. Methods In a randomized noninferiority and superiority trial, we compared the centrifugal‐flow pump with the axial‐flow pump in patients with advanced heart failure, irrespective of the intended goal of support (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke (with disabling stroke indicated by a modified Rankin score of >3; scores range from 0 to 6, with higher scores indicating more severe disability) or survival free of reoperation to replace or remove a malfunctioning device. The noninferiority margin for the risk difference (centrifugal‐flow pump group minus axial‐flow pump group) was ‐10 percentage points. Results Of 366 patients, 190 were assigned to the centrifugal‐flow pump group and 176 to the axial‐flow pump group. In the intention‐to‐treat population, the primary end point occurred in 151 patients (79.5%) in the centrifugal‐flow pump group, as compared with 106 (60.2%) in the axial‐flow pump group (absolute difference, 19.2 percentage points; 95% lower confidence boundary, 9.8 percentage points [P<0.001 for noninferiority]; hazard ratio, 0.46; 95% confidence interval [CI], 0.31 to 0.69 [P<0.001 for superiority]). Reoperation for pump malfunction was less frequent in the centrifugal‐flow pump group than in the axial‐flow pump group (3 patients [1.6%] vs. 30 patients [17.0%]; hazard ratio, 0.08; 95% CI, 0.03 to 0.27; P<0.001). The rates of death and disabling stroke were similar in the two groups, but the overall rate of stroke was lower in the centrifugal‐flow pump group than in the axial‐flow pump group (10.1% vs. 19.2%; hazard ratio, 0.47; 95% CI, 0.27 to 0.84, P=0.02). Conclusions In patients with advanced heart failure, a fully magnetically levitated centrifugal‐flow pump was superior to a mechanical‐bearing axial‐flow pump with regard to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.)


Circulation | 2017

Hemocompatibility-related Outcomes in the Momentum 3 Trial at 6 Months: A Randomized Controlled Study of a Fully Magnetically Levitated Pump in Advanced Heart Failure

Nir Uriel; P.C. Colombo; Joseph C. Cleveland; James W. Long; Christopher T. Salerno; Daniel J. Goldstein; Chetan B. Patel; Gregory A. Ewald; Antone Tatooles; Scott C. Silvestry; Ranjit John; Christiano Caldeira; Valluvan Jeevanandam; Andrew J. Boyle; Kartik S. Sundareswaran; Poornima Sood; Mandeep R. Mehra

Background: The HeartMate 3 (HM3) Left Ventricular Assist System (LVAS) (Abbott) is a centrifugal, fully magnetically levitated, continuous-flow blood pump engineered to enhance hemocompatibility and reduce shear stress on blood components. The MOMENTUM 3 trial (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) compares the HM3 LVAS with the HeartMate II (HMII) LVAS (Abbott) in advanced heart failure refractory to medical management, irrespective of therapeutic intention (bridge to transplant versus destination therapy). This investigation reported its primary outcome in the short-term cohort (n=294; 6-month follow-up), demonstrating superiority of the HM3 for the trial primary end point (survival free of a disabling stroke or reoperation to replace the pump for malfunction), driven by a reduced need for reoperations. The aim of this analysis was to evaluate the aggregate of hemocompatibility-related clinical adverse events (HRAEs) between the 2 LVAS. Methods: We conducted a secondary end point evaluation of HRAE (survival free of any nonsurgical bleeding, thromboembolic event, pump thrombosis, or neurological event) in the short-term cohort (as-treated cohort n=289) at 6 months. The net burden of HRAE was also assessed by using a previously described hemocompatibility score, which uses 4 escalating tiers of hierarchal severity to derive a total score for events encountered during the entire follow-up experience for each patient. Results: In 289 patients in the as-treated group (151 the HM3 and 138 the HMII), survival free of any HRAE was achieved in 69% of the HM3 group and in 55% of the HMII group (hazard ratio, 0.62; confidence interval, 0.42–0.91; P=0.012). Using the hemocompatibility score, the HM3 group demonstrated less pump thrombosis requiring reoperation (0 versus 36 points, P<0.001) or medically managed pump thrombosis (0 versus 5 points, P=0.02), and fewer nondisabling strokes (6 versus 24 points, P=0.026) than the control HMII LVAS. The net hemocompatibility score in the HM3 in comparison with the HMII patients was 101 (0.67±1.50 points/patient) versus 137 (0.99±1.79 points/patient) (odds ratio, 0.64; confidence interval, 0.39–1.03; P=0.065). Conclusions: In this secondary analysis of the MOMENTUM 3 trial, the HM3 LVAS demonstrated greater freedom from HRAEs in comparison with the HMII LVAS at 6 months. Clinical Trial Registration: URL: http://clinicaltrials.gov. Unique identifier: NCT02224755.

Collaboration


Dive into the Poornima Sood's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gregg W. Stone

Columbia University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

James B. Hermiller

St. Vincent's Health System

View shared research outputs
Top Co-Authors

Avatar

John C. Wang

Memorial Hospital of South Bend

View shared research outputs
Top Co-Authors

Avatar

Mandeep R. Mehra

Brigham and Women's Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nir Uriel

University of Chicago

View shared research outputs
Top Co-Authors

Avatar

Donald E. Cutlip

Beth Israel Deaconess Medical Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge