Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Prasath Mageswaran is active.

Publication


Featured researches published by Prasath Mageswaran.


Journal of Neurosurgery | 2012

Hybrid dynamic stabilization: a biomechanical assessment of adjacent and supraadjacent levels of the lumbar spine

Prasath Mageswaran; Fernando Techy; Robb Colbrunn; Tara F. Bonner; Robert F. McLain

OBJECT The object of this study was to evaluate the effect of hybrid dynamic stabilization on adjacent levels of the lumbar spine. METHODS Seven human spine specimens from T-12 to the sacrum were used. The following conditions were implemented: 1) intact spine; 2) fusion of L4-5 with bilateral pedicle screws and titanium rods; and 3) supplementation of the L4-5 fusion with pedicle screw dynamic stabilization constructs at L3-4, with the purpose of protecting the L3-4 level from excessive range of motion (ROM) and to create a smoother motion transition to the rest of the lumbar spine. An industrial robot was used to apply continuous pure moment (± 2 Nm) in flexion-extension with and without a follower load, lateral bending, and axial rotation. Intersegmental rotations of the fused, dynamically stabilized, and adjacent levels were measured and compared. RESULTS In flexion-extension only, the rigid instrumentation at L4-5 caused a 78% decrease in the segments ROM when compared with the intact specimen. To compensate, it caused an increase in motion at adjacent levels L1-2 (45.6%) and L2-3 (23.2%) only. The placement of the dynamic construct at L3-4 decreased the operated levels ROM by 80.4% (similar stability as the fusion at L4-5), when compared with the intact specimen, and caused a significant increase in motion at all tested adjacent levels. In flexion-extension with a follower load, instrumentation at L4-5 affected only a subadjacent level, L5-sacrum (52.0%), while causing a reduction in motion at the operated level (L4-5, -76.4%). The dynamic construct caused a significant increase in motion at the adjacent levels T12-L1 (44.9%), L1-2 (57.3%), and L5-sacrum (83.9%), while motion at the operated level (L3-4) was reduced by 76.7%. In lateral bending, instrumentation at L4-5 increased motion at only T12-L1 (22.8%). The dynamic construct at L3-4 caused an increase in motion at T12-L1 (69.9%), L1-2 (59.4%), L2-3 (44.7%), and L5-sacrum (43.7%). In axial rotation, only the placement of the dynamic construct at L3-4 caused a significant increase in motion of the adjacent levels L2-3 (25.1%) and L5-sacrum (31.4%). CONCLUSIONS The dynamic stabilization system displayed stability characteristics similar to a solid, all-metal construct. Its addition of the supraadjacent level (L3-4) to the fusion (L4-5) did protect the adjacent level from excessive motion. However, it essentially transformed a 1-level lumbar fusion into a 2-level lumbar fusion, with exponential transfer of motion to the fewer remaining discs.


American Journal of Sports Medicine | 2012

Analysis of baseball-to-helmet impacts in major league baseball

Aravind Athiviraham; Adam J. Bartsch; Prasath Mageswaran; Edward C. Benzel; Brian Perse; Morgan H. Jones; Mark S. Schickendantz

Background: In Major League Baseball (MLB), helmet hit-by-pitch (H-HBP) incidents are a leading cause of concussion. However, not all H-HBPs result in diagnosed concussion. Purpose: This study was designed to (1) quantify batter concussion risk as a function of H-HBP pitch velocity, time duration batter spent on the ground post–H-HBP, first responder assessment time duration, and number of days missed post–H-HBP and (2) estimate H-HBP impact locations on the helmet with respect to current National Operating Committee on Standards for Athletic Equipment (NOCSAE) helmet test standards and correlate impact locations with concussion diagnosis. Study Design: Case-control study; Level of evidence, 3. Methods: A retrospective case-control study of 18 MLB players with H-HBP incidents in the 2009 and 2010 seasons was undertaken. A database was compiled via quantitative and qualitative analysis using video coverage obtained from MLB. Quantitative factors included batter concussion diagnosis, pitch velocity, number of days missed post–H-HBP, time duration batter spent on the ground post–H-HBP, and first responder assessment time duration. The H-HBP impact location was among several qualitative factors developed via video analysis of each H-HBP from 4 raters. Results: In our study, 9 players (50%) were diagnosed with concussion. Concussion diagnoses were more frequent for posterior versus anterior impacts. The majority of H-HBP impact locations were different from those in the current NOCSAE standard tests. First responders took an average of approximately 65 seconds (time to reach batter plus assessment time) to decide on batter removal/return to play. The 25% logistic regression concussion risk threshold for pitch velocity and days missed was 86.2 mph and 1.3 days, respectively. The number of days missed after H-HBP showed a significant correlation (P = .02) among concussed and nonconcussed batters. Conclusion: In professional baseball H-HBP incidents, first responders should (1) be aware of pitch velocity in excess of 86 mph and (2) be provided ample time when assessing batters’ removal/return to play. Clinical Relevance: First responders should not rely solely on visual indicators such as batter reaction, holding head, or amount of time spent on the ground after H-HBP when assessing batters for concussion. Batting helmets in the MLB should maximize protection and mitigate impact dosage for H-HBP impact locations and velocity in addition to NOCSAE standard test locations and velocities.


The Spine Journal | 2014

Biomechanical analysis of the upper thoracic spine after decompressive procedures

Andrew T. Healy; Daniel Lubelski; Prasath Mageswaran; Deb A Bhowmick; Adam J. Bartsch; Edward C. Benzel; Thomas E. Mroz

BACKGROUND CONTEXT Decompressive procedures such as laminectomy, facetectomy, and costotransversectomy are routinely performed for various pathologies in the thoracic spine. The thoracic spine is unique, in part, because of the sternocostovertebral articulations that provide additional strength to the region relative to the cervical and lumbar spines. During decompressive surgeries, stability is compromised at a presently unknown point. PURPOSE To evaluate thoracic spinal stability after common surgical decompressive procedures in thoracic spines with intact sternocostovertebral articulations. STUDY DESIGN Biomechanical cadaveric study. METHODS Fresh-frozen human cadaveric spine specimens with intact rib cages, C7-L1 (n=9), were used. An industrial robot tested all spines in axial rotation (AR), lateral bending (LB), and flexion-extension (FE) by applying pure moments (±5 Nm). The specimens were first tested in their intact state and then tested after each of the following sequential surgical decompressive procedures at T4-T5 consisting of laminectomy; unilateral facetectomy; unilateral costotransversectomy, and subsequently instrumented fusion from T3-T7. RESULTS We found that in all three planes of motion, the sequential decompressive procedures caused no statistically significant change in motion between T3-T7 or T1-T12 when compared with intact. In comparing between intact and instrumented specimens, our study found that instrumentation reduced global range of motion (ROM) between T1-T12 by 16.3% (p=.001), 12% (p=.002), and 18.4% (p=.0004) for AR, FE, and LB, respectively. Age showed a negative correlation with motion in FE (r = -0.78, p=.01) and AR (r=-0.7, p=.04). CONCLUSIONS Thoracic spine stability was not significantly affected by sequential decompressive procedures in thoracic segments at the level of the true ribs in all three planes of motion in intact thoracic specimens. Age appeared to negatively correlate with ROM of the specimen. Our study suggests that thoracic spinal stability is maintained immediately after unilateral decompression at the level of the true ribs. These preliminary observations, however, do not depict the long-term sequelae of such procedures and warrant further investigation.


The Spine Journal | 2014

Biomechanics of the lower thoracic spine after decompression and fusion: a cadaveric analysis

Daniel Lubelski; Andrew T. Healy; Prasath Mageswaran; Edward C. Benzel; Thomas E. Mroz

BACKGROUND CONTEXT Few studies have evaluated the extent of biomechanical destabilization of thoracic decompression on the upper and lower thoracic spine. The present study evaluates lower thoracic spinal stability after laminectomy, unilateral facetectomy, and unilateral costotransversectomy in thoracic spines with intact sternocostovertebral articulations. PURPOSE To assess the biomechanical impact of decompression and fixation procedures on lower thoracic spine stability. STUDY DESIGN Biomechanical cadaveric study. METHODS Sequential surgical decompression (laminectomy, unilateral facetectomy, unilateral costotransversectomy) and dorsal fixation were performed on the lower thoracic spine (T8-T9) of human cadaveric spine specimens with intact rib cages (n=10). An industrial robot was used to apply pure moments to simulate flexion-extension (FE), lateral bending (LB), and axial rotation (AR) in the intact specimens and after decompression and fixation. Global range of motion (ROM) between T1-T12 and intrinsic ROM between T7-T11 were measured for each specimen. RESULTS The decompression procedures caused no statistically significant change in either global or intrinsic ROM compared with the intact state. Instrumentation, however, reduced global motion for AR (45° vs. 30°, p=.0001), FE (24° vs. 19°, p=.02), and LB (47° vs. 36°, p=.0001) and for intrinsic motion for AR (17° vs. 4°, p=.0001), FE (8° vs. 1°, p=.0001), and LB (12° vs. 1°, p=.0001). No significant differences were identified between decompression of the upper versus lower thoracic spine, with trends toward significantly greater ROM for AR and lower ROM for LB in the lower thoracic spine. CONCLUSIONS The lower thoracic spine was not destabilized by sequential unilateral decompression procedures. Addition of dorsal fixation increased segment rigidity at intrinsic levels and also reduced overall ROM of the lower thoracic spine to a greater extent than did fusing the upper thoracic spine (level of the true ribs). Despite the lack of true ribs, the lower thoracic spine was not significantly different compared with the upper thoracic spine in FE and LB after decompression, although there were trends toward significance for greater AR after decompression. In certain patients, instrumentation may not be needed after unilateral decompression of the lower thoracic spine; further validation and additional clinical studies are warranted.


Journal of Neurosurgery | 2014

Biomechanical evaluation of a simulated T-9 burst fracture of the thoracic spine with an intact rib cage.

Tiffany G. Perry; Prasath Mageswaran; Robb Colbrunn; Tara F. Bonner; Todd Francis; Robert F. McLain

OBJECT Classic biomechanical models have used thoracic spines disarticulated from the rib cage, but the biomechanical influence of the rib cage on fracture biomechanics has not been investigated. The well-accepted construct for stabilizing midthoracic fractures is posterior instrumentation 3 levels above and 2 levels below the injury. Short-segment fixation failure in thoracolumbar burst fractures has led to kyphosis and implant failure when anterior column support is lacking. Whether shorter constructs are viable in the midthoracic spine is a point of controversy. The objective of this study was the biomechanical evaluation of a burst fracture at T-9 with an intact rib cage using different fixation constructs for stabilizing the spine. METHODS A total of 8 human cadaveric spines (C7-L1) with intact rib cages were used in this study. The range of motion (ROM) between T-8 and T-10 was the outcome measure. A robotic spine testing system was programmed to apply pure moment loads (± 5 Nm) in lateral bending, flexion-extension, and axial rotation to whole thoracic specimens. Intersegmental rotations were measured using an optoelectronic system. Flexibility tests were conducted on intact specimens, then sequentially after surgically induced fracture at T-9, and after each of 4 fixation construct patterns. The 4 construct patterns were sequentially tested in a nondestructive protocol, as follows: 1) 3 above/2 below (3A/2B); 2) 1 above/1 below (1A/1B); 3) 1 above/1 below with vertebral body augmentation (1A/1B w/VA); and 4) vertebral body augmentation with no posterior instrumentation (VA). A repeated-measures ANOVA was used to compare the segmental motion between T-8 and T-10 vertebrae. RESULTS Mean ROM increased by 86%, 151%, and 31% after fracture in lateral bending, flexion-extension, and axial rotation, respectively. In lateral bending, there was significant reduction compared with intact controls for all 3 instrumented constructs: 3A/2B (-92%, p = 0.0004), 1A/1B (-63%, p = 0.0132), and 1A/1B w/VA (-66%, p = 0.0150). In flexion-extension, only the 3A/2B pattern showed a significant reduction (-90%, p = 0.011). In axial rotation, motion was significantly reduced for the 3 instrumented constructs: 3A/2B (-66%, p = 0.0001), 1A/1B (-53%, p = 0.0001), and 1A/1B w/VA (-51%, p = 0.0002). Between the 4 construct patterns, the 3 instrumented constructs (3A/2B, 1A/1B, and 1A/1B w/VA) showed comparable stability in all 3 motion planes. CONCLUSIONS This study showed no significant difference in the stability of the 3 instrumented constructs tested when the rib cage is intact. Fractures that might appear more grossly unstable when tested in the disarticulated spine may be bolstered by the ribs. This may affect the extent of segmental spinal instrumentation needed to restore stability in some spine injuries. While these initial findings suggest that shorter constructs may adequately stabilize the spine in this fracture model, further study is needed before these results can be extrapolated to clinical application.


Journal of Neurosurgery | 2015

Thoracic range of motion, stability, and correlation to imaging-determined degeneration

Andrew T. Healy; Prasath Mageswaran; Daniel Lubelski; Benjamin P. Rosenbaum; Virgilio Matheus; Edward C. Benzel; Thomas E. Mroz

OBJECT The degenerative process of the spinal column results in instability followed by a progressive loss of segmental motion. Segmental degeneration is associated with intervertebral disc and facet changes, which can be quantified. Correlating this degeneration with clinical segmental motion has not been investigated in the thoracic spine. The authors sought to determine if imaging-determined degeneration would correlate with native range of motion (ROM) or the change in ROM after decompressive procedures, potentially guiding clinical decision making in the setting of spine trauma or following decompressive procedures in the thoracic spine. METHODS Multidirectional flexibility tests with image analysis were performed on thoracic cadaveric spines with intact ib cage. Specimens consisted of 19 fresh frozen human cadaveric spines, spanning C-7 to L-1. ROM was obtained for each specimen in axial rotation (AR), flexion-extension (FE), and lateral bending (LB) in the intact state and following laminectomy, unilateral facetectomy, and unilateral costotransversectomy performed at either T4-5 (in 9 specimens) or T8-9 (in 10 specimens). Image grading of segmental degeneration was performed utilizing 3D CT reconstructions. Imaging scores were obtained for disc space degeneration, which quantified osteophytes, narrowing, and endplate sclerosis, all contributing to the Lane disc summary score. Facet degeneration was quantified using the Weishaupt facet summary score, which included the scoring of facet osteophytes, narrowing, hypertrophy, subchondral erosions, and cysts. RESULTS The native ROM of specimens from T-1 to T-12 (n = 19) negatively correlated with age in AR (Pearsons r coefficient = -0.42, p = 0.070) and FE (r = -0.42, p = 0.076). When regional ROM (across 4 adjacent segments) was considered, the presence of disc osteophytes negatively correlated with FE (r = -0.69, p = 0.012), LB (r = -0.82, p = 0.001), and disc narrowing trended toward significance in AR (r = -0.49, p = 0.107). Facet characteristics, scored using multiple variables, showed minimal correlation to native ROM (r range from -0.45 to +0.19); however, facet degeneration scores at the surgical level revealed strong negative correlations with regional thoracic stability following decompressive procedures in AR and LB (Weishaupt facet summary score: r = -0.52 and r = -0.71; p = 0.084 and p = 0.010, respectively). Disc degeneration was not correlated (Lane disc summary score: r = -0.06, p = 0.861). CONCLUSIONS Advanced age was the most important determinant of decreasing native thoracic ROM, whereas imaging characteristics (T1-12) did not correlate with the native ROM of thoracic specimens with intact rib cages. Advanced facet degeneration at the surgical level did correlate to specimen stability following decompressive procedures, and is likely indicative of the terminal stages of segmental degeneration.


Journal of Neurosurgery | 2014

Zero-profile hybrid fusion construct versus 2-level plate fixation to treat adjacent-level disease in the cervical spine

Andrew T. Healy; Swetha J. Sundar; Raul J. Cardenas; Prasath Mageswaran; Edward C. Benzel; Thomas E. Mroz; Todd B. Francis

OBJECT Single-level anterior cervical discectomy and fusion (ACDF) is an established surgical treatment for cervical myelopathy. Within 10 years of undergoing ACDF, 19.2% of patients develop symptomatic adjacent-level degeneration. Performing ACDF adjacent to prior fusion requires exposure and removal of previously placed hardware, which may increase the risk of adverse outcomes. Zero-profile cervical implants combine an interbody spacer with an anterior plate into a single device that does not extend beyond the intervertebral disc space, potentially obviating the need to remove prior hardware. This study compared the biomechanical stability and adjacent-level range of motion (ROM) following placement of a zero-profile device (ZPD) adjacent to a single-level ACDF against a standard 2-level ACDF. METHODS In this in vitro biomechanical cadaveric study, multidirectional flexibility testing was performed by a robotic spine system that simulates flexion-extension, lateral bending, and axial rotation by applying a continuous pure moment load. Testing conditions were as follows: 1) intact, 2) C5-6 ACDF, 3) C4-5 ZPD supraadjacent to simulated fusion at C5-6, and 4) 2-level ACDF (C4-6). The sequence of the latter 2 test conditions was randomized. An unconstrained pure moment of 1.5 Nm with a 40-N simulated head weight load was applied to the intact condition first in all 3 planes of motion and then using the hybrid test protocol, overall intact kinematics were replicated subsequently for each surgical test condition. Intersegmental rotations were measured optoelectronically. Mean segmental ROM for operated levels and adjacent levels was recorded and normalized to the intact condition and expressed as a percent change from intact. A repeated-measures ANOVA was used to analyze the ROM between test conditions with a 95% level of significance. RESULTS No statistically significant differences in immediate construct stability were found between construct Patterns 3 and 4, in all planes of motion (p > 0.05). At the operated level, C4-5, the zero-profile construct showed greater decreases in axial rotation (-45% vs -36%) and lateral bending (-55% vs -38%), whereas the 2-level ACDF showed greater decreases in flexion-extension (-40% vs -34%). These differences were marginal and not statistically significant. Adjacent-level motion was nearly equivalent, with minor differences in flexion-extension. CONCLUSIONS When treating degeneration adjacent to a single-level ACDF, a zero-profile implant showed stabilizing potential at the operated level statistically similar to that of the standard revision with a 2-level plate. Revision for adjacent-level disease is common, and using a ZPD in this setting should be investigated clinically because it may be a faster, safer alternative.


Computer Methods in Biomechanics and Biomedical Engineering | 2014

Multi-scale finite element modelling at the posterior lumbar vertebra: analysis of pedicle stresses due to pars fracture

Serkan Inceoglu; Prasath Mageswaran

Multi-scale finite element (FE) model is a cost-effective way to analyse stress response of micro-level structures to the changes in loading at macro-level. This study deals with the development of a multi-scale model of a human vertebra and stress changes in the pedicle at high resolution after a gross fracture at the posterior neural arch. Spondylolysis (pars fracture) is a painful condition occurring in the vertebral neural arch and common especially among the athletic young population. The fracture of the pars significantly alters load distribution and load transfer characteristics at the neural arch. Structural changes in the posterior vertebra due to the new loading patterns can trigger secondary complications. Clinical reports have shown the association of pedicle hypertrophy or pedicle fracture with unilateral pars fractures. However, the biomechanical consequences of pars fracture and its effect on the pedicle have never been studied in detail. Therefore, we prepared a multi-scale model of posterior vertebra with continuum laminar complex model combined with micro-FE model of a pedicle section. The results showed that stress at the contralateral pars and pedicle increased after unilateral pars fracture simulation. High-stress regions were found around the outer boundaries of the pedicle. This model and information are helpful in understanding the stress changes in the pedicle and can be used for adaptive remodelling studies.


The Spine Journal | 2013

Properties of an interspinous fixation device (ISD) in lumbar fusion constructs: a biomechanical study

Fernando Techy; Prasath Mageswaran; Robb Colbrunn; Tara F. Bonner; Robert F. McLain


Journal of Neurosurgery | 2013

Plate fixation in the cervical spine: traditional paramedian screw configuration compared with unique unilateral configuration.

Prasath Mageswaran; Robert F. McLain; Robb Colbrunn; Tara F. Bonner; Elijah Hothem; Adam J. Bartsch

Collaboration


Dive into the Prasath Mageswaran's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Fernando Techy

Rosalind Franklin University of Medicine and Science

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge