Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Qiugen Wang is active.

Publication


Featured researches published by Qiugen Wang.


Journal of Solar Energy Engineering-transactions of The Asme | 1997

Study on a new solid absorption refrigeration pair : Active carbon fiber-methanol

R.Z. Wang; J. P. Jia; Y. H. Zhu; Y. Teng; J. Y. Wu; J. Cheng; Qiugen Wang

The experiments show that active carbon fiber (ACF) might be a good substitute for activated carbon (AC) as the refrigeration capacity Q{sub f} and adsorption time of ACF are three times more and 1/5--1/10 of those of normal activated carbon (AC), respectively. The COP for ACF-methanol could be 10% {approximately} 20% higher than that of AC-methanol. Thus ACF-methanol might be a good adsorption refrigeration pair for constructing adsorption refrigerators, especially those for household applications.


Journal of Biomedical Informatics | 2015

Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display

Xiaojun Chen; Lu Xu; Yiping Wang; Huixiang Wang; Fang Wang; Xiangsen Zeng; Qiugen Wang; Jan Egger

The surgical navigation system has experienced tremendous development over the past decades for minimizing the risks and improving the precision of the surgery. Nowadays, Augmented Reality (AR)-based surgical navigation is a promising technology for clinical applications. In the AR system, virtual and actual reality are mixed, offering real-time, high-quality visualization of an extensive variety of information to the users (Moussa et al., 2012) [1]. For example, virtual anatomical structures such as soft tissues, blood vessels and nerves can be integrated with the real-world scenario in real time. In this study, an AR-based surgical navigation system (AR-SNS) is developed using an optical see-through HMD (head-mounted display), aiming at improving the safety and reliability of the surgery. With the use of this system, including the calibration of instruments, registration, and the calibration of HMD, the 3D virtual critical anatomical structures in the head-mounted display are aligned with the actual structures of patient in real-world scenario during the intra-operative motion tracking process. The accuracy verification experiment demonstrated that the mean distance and angular errors were respectively 0.809±0.05mm and 1.038°±0.05°, which was sufficient to meet the clinical requirements.


Injury-international Journal of The Care of The Injured | 2016

Application of an innovative computerized virtual planning system in acetabular fracture surgery: A feasibility study.

Huixiang Wang; Fang Wang; Simon Newman; Yanping Lin; Xiaojun Chen; Lu Xu; Qiugen Wang

INTRODUCTION Acetabular fracture surgery is amongst the most challenging tasks in the field of trauma surgery and careful preoperative planning is crucial for success. The aim of this paper is to describe the preliminary outcome of the utilization of an innovative computerized virtual planning system for acetabular fractures. METHODS 3D models of acetabular fractures and surrounding soft tissues from six patients were constructed from preoperative CT scans. A novel highly-automatic segmentation technique was performed on the 3D model to separate each fracture fragment, then 3D virtual reduction was performed. Additionally, the models were used to assess potential surgical approaches with reference to both the fracture and the surrounding soft tissues. The time required for virtual planning was recorded. After surgery, the virtual plan was compared to the real surgery with respect to surgical approach and reduction sequence. A Likert scale questionnaire was completed by the surgeons to evaluate their satisfaction with the system. RESULTS Virtual planning was successfully completed in all cases. The planned surgical approach was followed in all cases with the planned reduction sequence followed completely in five cases and partially in one. The mean time required for virtual planning was 38.7min (range 21-57, SD=15.5). The mean time required for planning of B-type fractures was 25.0min (range 21-30, SD=4.6), of C-type fracture 52.3min (range 49-57, SD=4.2). The results of the questionnaire demonstrated a high level of satisfaction with the planning system. CONCLUSION This study demonstrates that the virtual planning system is feasible in clinical settings with high satisfaction and acceptability from the surgeons. It provides a viable option for the planning of acetabular fracture surgery.


Medical Engineering & Physics | 2014

3-D finite element analysis of the influence of synovial condition in sacroiliac joint on the load transmission in human pelvic system

Dufang Shi; Fang Wang; Dongmei Wang; Xiaoqin Li; Qiugen Wang

The anterior part of the sacroiliac joint (SIJ) is a synovial joint, with little gliding and rotary movement between the contact surfaces of SIJ during locomotion. Due to its complex structure, especially when considering the surrounding ligaments, it is difficult to construct an accurate three-dimensional (3-D) finite element model for the human pelvis. Most of the pelvic models in the previous studies were simplified with either SIJ fusing together or without the sacral bone. However, the influence of those simplifications on the load transmission in human pelvis has not been studied, so the reliability of those studies remains unclear. In this study, two 3-D pelvic models were constructed: an SIJ fusing model and an SIJ contacting model. In the SIJ fusing model, the SIJ interfaces were fused together. In the SIJ contacting model, the SIJ interfaces were just in contact with each other without fusion. Compared with the SIJ contacting model, the SIJ fusing model have smaller movements in the SIJ. The stress distribution area in the SIJ fusing model on sacroiliac cartilages was also different. Those differences contributed to the decline of tensile force in the SIJ surrounding ligaments and the re-distribution of stress in the pelvic bones. In addition, the SIJ fusing model was far less sensitive to the increase in modulus of the sacroiliac cartilages, and decrease in stiffness of the ligaments surrounding the SIJ. The presence of synovia in the SIJ had greater influence on the load transmission in the human pelvic system. Therefore, the effect of the presence of synovia should not be neglected when the biomechanical behavior of human pelvis is being studied, especially for those studies related to clinical applications.


Medical Engineering & Physics | 2017

Development of a surgical navigation system based on 3D Slicer for intraoperative implant placement surgery

Xiaojun Chen; Lu Xu; Huixiang Wang; Fang Wang; Qiugen Wang; Ron Kikinis

Implant placement has been widely used in various kinds of surgery. However, accurate intraoperative drilling performance is essential to avoid injury to adjacent structures. Although some commercially-available surgical navigation systems have been approved for clinical applications, these systems are expensive and the source code is not available to researchers. 3D Slicer is a free, open source software platform for the research community of computer-aided surgery. In this study, a loadable module based on Slicer has been developed and validated to support surgical navigation. This research module allows reliable calibration of the surgical drill, point-based registration and surface matching registration, so that the position and orientation of the surgical drill can be tracked and displayed on the computer screen in real time, aiming at reducing risks. In accuracy verification experiments, the mean target registration error (TRE) for point-based and surface-based registration were 0.31±0.06mm and 1.01±0.06mm respectively, which should meet clinical requirements. Both phantom and cadaver experiments demonstrated the feasibility of our surgical navigation software module.


Colloids and Surfaces B: Biointerfaces | 2018

Selenium nanocomposites as multifunctional nanoplatform for imaging guiding synergistic chemo-photothermal therapy

Xijian Liu; Yeying Wang; Qiyang Yu; Guoying Deng; Qian Wang; Xinhui Ma; Qiugen Wang; Jie Lu

A multifunctional selenium nanocomposite (selenium@silica core-shell nanoshperes for loading indocyanine green(ICG)/Doxorubicin(DOX)) was fabricated to reach visible and efficient cancer treatment. The Se@SiO2-ICG nanocomposites could be used not only as excellent photothermal agents but also as carriers for DOX delivery. In addition, the Se@SiO2-ICG/DOX nanocomposites exhibited excellent fluorescence imaging and infrared imaging performance. Tumor could be effectively inhibited by Se@SiO2-ICG/DOX due to the triple treatment of photothermal effect and chemotherapy of selenium and DOX. Thus, the Se@SiO2-ICG/DOX nanocomposites have a great potential in imaging guiding synergistic treatment of cancer.


Scientific Reports | 2017

Treatment of steroid-induced osteonecrosis of the femoral head using porous Se@SiO 2 nanocomposites to suppress reactive oxygen species

Guoying Deng; Kerun Niu; Feng Zhou; Buxiao Li; Yingjie Kang; Xijian Liu; Junqing Hu; Bo Li; Qiugen Wang; Chengqing Yi; Qian Wang

Reducing oxidative stress (ROS) have been demonstrated effective for steroid-induced osteonecrosis of the femoral head (steroid-induced ONFH). Selenium (Se) plays an important role in suppressing oxidative stress and has huge potential in ONFH treatments. However the Se has a narrow margin between beneficial and toxic effects which make it hard for therapy use in vivo. In order to make the deficiency up, a control release of Se (Se@SiO2) were realized by nanotechnology modification. Porous Se@SiO2 nanocomposites have favorable biocompatibility and can reduced the ROS damage effectively. In vitro, the cck-8 analysis, terminal dexynucleotidyl transferase (TdT)-mediated dUTP nick end labeling (TUNEL) stain and flow cytometry analysis showed rare negative influence by porous Se@SiO2 nanocomposites but significantly protective effect against H2O2 by reducing ROS level (detected by DCFH-DA). In vivo, the biosafety of porous Se@SiO2 nanocomposites were confirmed by the serum biochemistry, the ROS level in serum were significantly reduced and the curative effect were confirmed by Micro CT scan, serum Elisa assay (inflammatory factors), Western blotting (quantitative measurement of ONFH) and HE staining. It is expected that the porous Se@SiO2 nanocomposites may prevent steroid-induced ONFH by reducing oxidative stress.


International Journal of Nanomedicine | 2017

Porous Se@SiO 2 nanospheres treated paraquat-induced acute lung injury by resisting oxidative stress

Yong Zhu; Guoying Deng; Anqi Ji; Jiayi Yao; Xiaoxiao Meng; Jinfeng Wang; Qian Wang; Qiugen Wang; Ruilan Wang

Acute paraquat (PQ) poisoning is one of the most common forms of pesticide poisoning. Oxidative stress and inflammation are thought to be important mechanisms in PQ-induced acute lung injury (ALI). Selenium (Se) can scavenge intracellular free radicals directly or indirectly. In this study, we investigated whether porous Se@SiO2 nanospheres could alleviate oxidative stress and inflammation in PQ-induced ALI. Male Sprague Dawley rats and RLE-6TN cells were used in this study. Rats were categorized into 3 groups: control (n=6), PQ (n=18), and PQ + Se@SiO2 (n=18). The PQ and PQ + Se@SiO2 groups were randomly and evenly divided into 3 sub-groups according to different time points (24, 48 and 72 h) after PQ treatment. Porous Se@SiO2 nanospheres 1 mg/kg (in the PQ + Se@SiO2 group) were administered via intraperitoneal injection every 24 h. Expression levels of reduced glutathione, malondialdehyde, superoxide dismutase, reactive oxygen species (ROS), nuclear factor-κB (NF-κB), phosphorylated NF-κB (p-NF-κB), tumor necrosis factor-α and interleukin-1β were detected, and a histological analysis of rat lung tissues was performed. The results showed that the levels of ROS, malondialdehyde, NF-κB, p-NF-κB, tumor necrosis factor-α and interleukin-1β were markedly increased after PQ treatment. Glutathione and superoxide dismutase levels were reduced. However, treatment with porous Se@SiO2 nanospheres markedly alleviated PQ-induced oxidative stress and inflammation. Additionally, the results from histological examinations and wet-to-dry weight ratios of rat lung tissues showed that lung damage was reduced after porous Se@SiO2 nanosphere treatment. These data indicate that porous Se@SiO2 nanospheres may reduce NF-κB, p-NF-κB and inflammatory cytokine levels by inhibiting ROS in PQ-induced ALI. This study demonstrates that porous Se@SiO2 nanospheres may be a therapeutic method for use in the future for PQ poisoning.


International Journal of Nanomedicine | 2018

Porous Se@SiO 2 nanocomposites protect the femoral head from methylprednisolone-induced osteonecrosis

Guoying Deng; Chenyun Dai; Jinyuan Chen; Anqi Ji; Jingpeng Zhao; Yue Zhai; Yingjie Kang; Xijian Liu; Yin Wang; Qiugen Wang

Background Methylprednisolone (MPS) is an important drug used in therapy of many diseases. However, osteonecrosis of the femoral head is a serious damage in the MPS treatment. Thus, it is imperative to develop new drugs to prevent the serious side effect of MPS. Methods The potential interferences Se@SiO2 nanocomposites may have to the therapeutic effect of methylprednisolone (MPS) were evaluated by classical therapeutic effect index of acute respiratory distress syndrome (ARDS), such as wet-to-dry weight ratio, inflammatory factors IL-1β and TNF-α. And oxidative stress species (ROS) index like superoxide dismutase (SOD) and glutathione (GSH) were tested. Then, the protection effects of Se@SiO2 have in osteonecrosis of the femoral head (ONFH) were evaluated by micro CT, histologic analysis and Western-blot analysis. Results In the present study, we found that in the rat model of ARDS, Se@SiO2 nanocomposites induced SOD and GSH indirectly to reduce ROS damage. The wet-to-dry weight ratio of lung was significantly decreased after MPS treatment compared with the control group, whereas the Se@SiO2 did not affect the reduced wet-to-dry weight ratio of MPS. Se@SiO2 also did not impair the effect of MPS on the reduction of inflammatory factors IL-1β and TNF-α, and on the alleviation of structural destruction. Furthermore, micro CT and histologic analysis confirmed that Se@SiO2 significantly alleviate MPS-induced destruction of femoral head. Moreover, compared with MPS group, Se@SiO2 could increase collagen II and aggrecan, and reduce the IL-1β level in the cartilage of femoral head. In addition, the biosafety of Se@SiO2 in vitro and in vivo were supported by cell proliferation assay and histologic analysis of main organs from rat models. Conclusion Se@SiO2 nanocomposites have a protective effect in MPS-induced ONFH without influence on the therapeutic activity of MPS, suggesting the potential as effective drugs to avoid ONFH in MPS therapy.


International Journal of Nanomedicine | 2017

Inhibition of cancer cell migration with CuS@mSiO 2 -PEG nanoparticles by repressing MMP-2/MMP-9 expression

Guoying Deng; Feng Zhou; Zizheng Wu; Fei Zhang; Kerun Niu; Yingjie Kang; Xijian Liu; Qiugen Wang; Yin Wang; Qian Wang

The metastasis of cancer cells is a vital aspect of disease progression and therapy. Although a few nanoparticles (NPs) aimed at controlling metastasis in cancer therapy have been reported, the NPs are normally combined with drugs, yet the direct therapeutic effects of the NPs are not reported. To study the direct influence of NPs on cancer metastasis, the potential suppression capacity of CuS@mSiO2-PEG NPs to tumor cell migration, a kind of typical photothermal NPs, was systemically evaluated in this study. Using CuS@mSiO2-PEG NP stimulation and a transwell migration assay, we found that the migration of HeLa cells was significantly decreased. This phenomenon may be associated with two classical proteins in metastasis: matrix metalloproteinase 2 (MMP-2) and matrix metalloproteinase 9 (MMP-9). In addition, the mechanism may closely associate with non-receptor tyrosine kinase protein (SRC)/focal adhesion kinase (FAK) signaling pathway which varies in vivo and in vitro. To confirm the differences in the expression of SRC and FAK, related inhibitors were studied for additional comparison. Also, the results indicated that even though the migration inhibition was closely related to SRC and FAK signaling pathway, there may be another unknown regulation mechanism existing and its metastasis inhibition was significant. Confirmed by long-term survival curve study, CuS@mSiO2-PEG NPs significantly reduced the metastasis of cancer cells and improved the survival rates of metastasis in a mouse model. Thus, we believe that the direct influence of NPs on cancer cell metastasis is a promising study topic.

Collaboration


Dive into the Qiugen Wang's collaboration.

Top Co-Authors

Avatar

Fang Wang

Shanghai Jiao Tong University

View shared research outputs
Top Co-Authors

Avatar

Dongmei Wang

Shanghai Jiao Tong University

View shared research outputs
Top Co-Authors

Avatar

Guoying Deng

Shanghai Jiao Tong University

View shared research outputs
Top Co-Authors

Avatar

Qian Wang

Shanghai Jiao Tong University

View shared research outputs
Top Co-Authors

Avatar

Xiaoxi Ji

Shanghai Jiao Tong University

View shared research outputs
Top Co-Authors

Avatar

Huixiang Wang

Shanghai Jiao Tong University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Chun Bi

Shanghai Jiao Tong University

View shared research outputs
Top Co-Authors

Avatar

Feng Zhou

Shanghai Jiao Tong University

View shared research outputs
Top Co-Authors

Avatar

Jiandong Wang

Shanghai Jiao Tong University

View shared research outputs
Researchain Logo
Decentralizing Knowledge