Que Jiemin
Chinese Academy of Sciences
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Que Jiemin.
Chinese Physics C | 2012
Que Jiemin; Cao Daquan; Zhao Wei; Tang Xiao; Sun Cuili; Wang Yanfang; Wei Cunfeng; Shi Rongjian; Wei Long; Yu Zhong-Qiang; Yan Yonglian
Computed laminography (CL) is an alternative to computed tomography if large objects are to be inspected with high resolution. This is especially true for planar objects. In this paper, we set up a new scanning geometry for CL, and study the algebraic reconstruction technique (ART) for CL imaging. We compare the results of ART with variant weighted functions by computer simulation with a digital phantom. It proves that ART algorithm is a good choice for the CL system.
Chinese Physics C | 2011
Zhao Wei; Fu Guo-Tao; Sun Cuili; Wang Yanfang; Wei Cunfeng; Cao Daquan; Que Jiemin; Tang Xiao; Shi Rongjian; Wei Long; Yu Zhong-Qiang
In this paper, we present a beam hardening correction (BHC) method in three-dimension space for a cone-beam computed tomography (CBCT) system in a mono-material case and investigate its effect on the spatial resolution. Due to the polychromatic character of the X-ray spectrum used, cupping and streak artifacts called beam hardening artifacts arise in the reconstructed CT images, causing reduced image quality. In addition, enhanced edges are introduced in the reconstructed CT images because of the beam hardening effect. The spatial resolution of the CBCT system is calculated from the edge response function (ERF) on different planes in space. Thus, in the CT images with beam hardening artifacts, enhanced ERFs will be extracted to calculate the modulation transfer function (MTF), obtaining a better spatial resolution that deviates from the real value. Reasonable spatial resolution can be obtained after reducing the artifacts. The 10% MTF value and the full width at half maximum (FWHM) of the point spread function with and without BHC are presented.
Chinese Physics C | 2012
Tang Xiao; Zhao Wei; Wang Yanfang; Shu Hang; Sun Cuili; Wei Cunfeng; Cao Daquan; Que Jiemin; Shi Rongjian; Wei Long
A dedicated breast CT system (DBCT) is a new method for breast cancer detection proposed in recent years. In this paper, the glandular dose in the DBCT is simulated using the Monte Carlo method. The phantom shape is half ellipsoid, and a series of phantoms with different sizes, shapes and compositions were constructed. In order to optimize the spectra, monoenergy X-ray beams of 5–80 keV were used in simulation. The dose distribution of a breast phantom was studied: a higher energy beam generated more uniform distribution, and the outer parts got more dose than the inner parts. For polyenergtic spectra, four spectra of Al filters with different thicknesses were simulated, and the polyenergtic glandular dose was calculated as a spectral weighted combination of the monoenergetic dose.
Archive | 2013
Wang Yaxiao; Wei Cunfeng; Shu Yanfeng; Que Jiemin; Sun Cuili; Wang Zhe; Cao Daquan; Meng Fanhui
Archive | 2015
Shao Yumeng; Wei Long; Wei Cunfeng; Wang Yanfang; Que Jiemin; Liu Baodong; Wang Yaxiao; Yuan Lulu; Zhou Junguang; Meng Fanhui
Archive | 2013
Shu Yanfeng; Wei Cunfeng; Que Jiemin; Meng Fanhui; Wang Yaxiao; Sun Cuili; Wang Zhe; Cao Daquan; Zhou Junguang
Archive | 2017
Chen Xu; Wei Cunfeng; Jiang Pengfei; Que Jiemin; Yuan Lulu; Wei Long
Archive | 2017
Yang Mingjie; Wang Yingjie; Liu Yantao; Zhang Zhiming; Zhu Meiling; Li Daowu; Que Jiemin; Liu Lin; Zhou Wei; Tong Teng; Shi Rongjian; Wei Cunfeng; Wei Long
Archive | 2016
Shao Yumeng; Wei Long; Wei Cunfeng; Wang Yanfang; Que Jiemin; Liu Baodong; Wang Yaxiao; Yuan Lulu; Zhou Junguang; Meng Fanhui
Archive | 2016
Que Jiemin; Wei Cunfeng; Sun Cuili; Shu Yanfeng; Meng Fanhui; Cao Daquan; Yang Shengyu; Shi Rongjian; Wei Long