R. Dzhygadlo
Forschungszentrum Jülich
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by R. Dzhygadlo.
Journal of Instrumentation | 2016
E. Etzelmüller; A. Belias; R. Dzhygadlo; A. Gerhardt; K. Götzen; G. Kalicy; M. Krebs; D. Lehmann; F. Nerling; M. Patsyuk; K. Peters; G. Schepers; L. Schmitt; C. Schwarz; J. Schwiening; M. Traxler; M. Zühlsdorf; A. Britting; W. Eyrich; A. Lehmann; M. Pfaffinger; F. Uhlig; M. Düren; K. Föhl; A. Hayrapetyan; B. Kröck; O. Merle; J. Rieke; M. Schmidt; E. Cowie
The PANDA experiment at the future Facility for Antiproton and Ion Research (FAIR) requires excellent particle identification. Two different DIRC detectors will utilize internally reflected Cherenkov light of charged particles to enable the separation of pions and kaons up to momenta of 4 GeV/c. The Endcap Disc DIRC will be placed in the forward endcap of PANDAs central spectrometer covering polar angles between 5° and 22°. Its final design is based on MCP-PMTs for the photon detection and an optical system made of fused silica. A new prototype has been investigated during a test beam at CERN in May 2015 and first results will be presented. In addition a new synthetic fused silica material by Nikon has been tested and was found to be radiation hard.
Journal of Instrumentation | 2014
G. Kalicy; H. Kumawat; J. Schwiening; R. Dzhygadlo; A. Gerhardt; R. Hohler; D. Lehmann; B. Lewandowski; M. Patsyuk; K. Peters; G. Schepers; L. Schmitt; C. Schwarz; M. Traxler; M. Zühlsdorf; V.Kh. Dodokhov; A.S. Vodopianov; A. Britting; W. Eyrich; A. Lehmann; F. Uhlig; M. Düren; K. Föhl; A. Hayrapetyan; P Koch; B. Kröck; O. Merle; E. Cowie; T. Keri; R. A. Montgomery
The PANDA experiment at the future Facility for Antiproton and Ion Research in Europe GmbH (FAIR) at GSI, Darmstadt will study fundamental questions of hadron physics and QCD using high-intensity cooled antiproton beams with momenta between 1.5 and 15 GeV/c. Hadronic PID in the barrel region of the PANDA detector will be provided by a DIRC (Detection of Internally Reflected Cherenkov light) counter. The design is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. Detailed Monte Carlo simulation studies were performed for DIRC designs based on narrow bars or wide plates with a variety of focusing solutions. The performance of each design was characterized in terms of photon yield and single photon Cherenkov angle resolution and a maximum likelihood approach was used to determine the π/K separation. Selected design options were implemented in prototypes and tested with hadronic particle beams at GSI and CERN. This article describes the status of the design and R&D for the PANDA Barrel DIRC detector, with a focus on the performance of different DIRC designs in simulation and particle beams.
Journal of Instrumentation | 2016
J. Rieke; A. Belias; R. Dzhygadlo; A. Gerhardt; K. Götzen; G. Kalicy; M. Krebs; D. Lehmann; F. Nerling; M. Patsyuk; K. Peters; G. Schepers; L. Schmitt; C. Schwarz; J. Schwiening; M. Traxler; M. Zühlsdorf; A. Britting; W. Eyrich; A. Lehmann; M. Pfaffinger; F. Uhlig; M. Düren; E. Etzelmüller; K. Föhl; A. Hayrapetyan; B. Kröck; O. Merle; M. Schmidt; E. Cowie
Micro-channel plate photomultiplier tubes (MCP-PMTs) are chosen in many applications that have to cope with strong magnetic fields. The DIRC detectors of the PANDA experiment plan to employ them as they show excellent timing characteristics, radiation hardness, relatively low dark count rates and sufficient lifetime. This article mainly focuses on the performance of the position reconstruction of detected photons. Two different MCP-PMTs with segmented anode geometries have been tested in magnetic fields of different strengths. The variation of their performance has been studied. The measurements show improved position resolution and image shifts with increasing magnetic field strength.
nuclear science symposium and medical imaging conference | 2014
J. Rieke; M. Düren; E. Etzelmüller; K. Föhl; A. Hayrapetyan; B. Kröck; O. Merle; R. Dzhygadlo; A. Gerhardt; K. Götzen; G. Kalicy; M. Krebs; H. Kumawat; D. Lehmann; M. Patsyuk; K. Peters; G. Schepers; L. Schmitt; C. Schwarz; J. Schwiening; M. Traxler; M. Zühlsdorf; V.Kh. Dodokhov; F. Uhlig; A. Britting; W. Eyrich; A. Lehmann; E. Cowie; T. Keri; R. A. Montgomery
The upcoming PANDA Experiment at FAIR in Germany will be equipped with a novel Cherenkov detector type for high-energy particle identification. This very compact Disc-DIRC detector uses a large disc-shaped fused silica plate of 2 cm thickness as its Cherenkov radiator. The internally reflected Cherenkov light is transported to the rim of the disc where it is focused by quartz light guides onto microchannel plate photomultiplier tubes (MCP-PMTs) with high spatial resolution (pitch 0.5 mm) and high time resolution (σ ≈ 100 ps). The device has an active area of about 3 m2 and will be able to identify pions and kaons with a separation power of more than 3σ in the momentum range up to 4 GeV/c. It has 32400 individual pixels and each can handle a mean photon rate of up to about 100 kHz. The presented design deals with numerous challenges that come with the very hostile environment in which the detector has to function properly, caused by the presence of high magnetic fields of up to 2 Tesla, high levels of radiation, high particle and background rates and a tight spatial volume. First test measurements have shown the performance of the design.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2018
C. Schwarz; A. Ali; A. Belias; R. Dzhygadlo; A. Gerhardt; M. Krebs; D. Lehmann; K. Peters; G. Schepers; J. Schwiening; M. Traxler; L. Schmitt; M. Böhm; A. Lehmann; M. Pfaffinger; F. Uhlig; S. Stelter; M. Düren; E. Etzelmüller; K. Föhl; A. Hayrapetyan; K. Kreutzfeld; J. Rieke; M. Schmidt; T. Wasem; P. Achenbach; M. Cardinali; M. Hoek; W. Lauth; S. Schlimme
Abstract The PANDA experiment is one of the four large experiments being built at FAIR in Darmstadt. It will use a cooled antiproton beam on a fixed target within the momentum range of 1.5 to 15 GeV/c to address questions of strong QCD, where the coupling constant α s ≳ 0 . 3 . The luminosity of up to 2 ⋅ 1 0 32 cm − 2 s − 1 and the momentum resolution of the antiproton beam down to Δ p ∕ p = 4 ⋅ 1 0 − 5 allows for high precision spectroscopy, especially for rare reaction processes. Above the production threshold for open charm mesons the production of kaons plays an important role for identifying the reaction. The DIRC principle allows for a compact particle identification for charged particles in a hermetic detector, limited in size by the electromagnetic lead tungstate calorimeter. The Barrel DIRC in the target spectrometer covers polar angles between 22° and 140° and will achieve a pion–kaon separation of 3 standard deviations up to 3.5 GeV/ c . Here, results of a test beam are shown for a single radiator bar coupled to a prism with 33° opening angle, both made from synthetic fused silica read out with a photon detector array with 768 pixels.
Journal of Instrumentation | 2017
C. Schwarz; A. Ali; A. Belias; R. Dzhygadlo; A. Gerhardt; K. Götzen; G. Kalicy; M. Krebs; D. Lehmann; F. Nerling; M. Patsyuk; K. Peters; G. Schepers; L. Schmitt; J. Schwiening; M. Traxler; M. Zühlsdorf; M. Böhm; A. Britting; W. Eyrich; A. Lehmann; M. Pfaffinger; F. Uhlig; M. Düren; E. Etzelmüller; K. Föhl; A. Hayrapetyan; K. Kreutzfeld; B. Kröck; O. Merle
The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two DIRC (Detection of Internally Reflected Cherenkov light) counters in the target spectrometer. The design for the barrel region covering polar angles between 22o to 140o is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. The novel Endcap Disc DIRC will cover the smaller forward angles between 5o (10o) to 22o in the vertical (horizontal) direction. Both DIRC counters will use lifetime-enhanced microchannel plate PMTs for photon detection in combination with fast readout electronics. Geant4 simulations and tests with several prototypes at various beam facilities have been used to evaluate the designs and validate the expected PID performance of both PANDA DIRC counters.
Journal of Instrumentation | 2017
M. Schmidt; A. Ali; A. Belias; R. Dzhygadlo; A. Gerhardt; K. Götzen; G. Kalicy; M. Krebs; D. Lehmann; F. Nerling; M. Patsyuk; K. Peters; G. Schepers; L. Schmitt; C. Schwarz; J. Schwiening; M. Traxler; M. Böhm; W. Eyrich; A. Lehmann; M. Pfaffinger; F. Uhlig; M. Düren; E. Etzelmüller; K. Föhl; A. Hayrapetyan; K. Kreutzfeld; O. Merle; J. Rieke; T. Wasem
The EndcapDisc DIRC has been developed to provide an excellent particle identification for the future PANDA experiment by separating pions and kaons up to a momentum of 4GeV/c with a separation power of 3 standard deviations in the polar angle region from 5◦ to 22◦. This goal will be achieved using dedicated particle identification algorithms based on likelihood methods and will be applied in an offline analysis and online event filtering. This paper evaluates the resulting PID performance using Monte-Carlo simulations to study basic single track PID as well as the analysis of complex physics channels. The online reconstruction algorithm has been tested with a Virtex4 FGPA card and optimized regarding the resulting constraints.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2014
A. Lehmann; A. Britting; W. Eyrich; F. Uhlig; R. Dzhygadlo; A. Gerhardt; K. Götzen; R. Hohler; G. Kalicy; H. Kumawat; D. Lehmann; B. Lewandowski; M. Patsyuk; K. Peters; G. Schepers; L. Schmitt; C. Schwarz; J. Schwiening; M. Traxler; M. Zühlsdorf; V.Kh. Dodokhov; M. Düren; K. Föhl; A. Hayrapetyan; B. Kröck; O. Merle; J. Rieke; E. Cowie; T. Keri; R. A. Montgomery
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2014
M. Hoek; R. Dzhygadlo; A. Gerhardt; K. Götzen; R. Hohler; G. Kalicy; H. Kumawat; D. Lehmann; B. Lewandowski; M. Patsyuk; K. Peters; G. Schepers; L. Schmitt; C. Schwarz; J. Schwiening; M. Traxler; M. Zühlsdorf; V.Kh. Dodokhov; A. Britting; W. Eyrich; A. Lehmann; F. Uhlig; M. Düren; K. Föhl; A. Hayrapetyan; B. Kröck; O. Merle; J. Rieke; E. Cowie; T. Keri
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2014
O. Merle; R. Dzhygadlo; A. Gerhardt; K. Götzen; R. Hohler; G. Kalicy; H. Kumawat; D. Lehmann; B. Lewandowski; M. Patsyuk; K. Peters; G. Schepers; L. Schmitt; C. Schwarz; J. Schwiening; M. Traxler; M. Zühlsdorf; V.Kh. Dodokhov; A. Britting; W. Eyrich; A. Lehmann; F. Uhlig; M. Düren; E. Etzelmüller; K. Föhl; A. Hayrapetyan; B. Kröck; D. Mühlheim; J. Rieke; E. Cowie