R Thornton
UCL Institute of Neurology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by R Thornton.
Brain | 2011
Frédéric Grouiller; R Thornton; Kristina Groening; Laurent Spinelli; John S. Duncan; Karl Lothard Schaller; Michael Siniatchkin; Louis Lemieux; Margitta Seeck; Christoph M. Michel; Serge Vulliemoz
In patients with medically refractory focal epilepsy who are candidates for epilepsy surgery, concordant non-invasive neuroimaging data are useful to guide invasive electroencephalographic recordings or surgical resection. Simultaneous electroencephalography and functional magnetic resonance imaging recordings can reveal regions of haemodynamic fluctuations related to epileptic activity and help localize its generators. However, many of these studies (40-70%) remain inconclusive, principally due to the absence of interictal epileptiform discharges during simultaneous recordings, or lack of haemodynamic changes correlated to interictal epileptiform discharges. We investigated whether the presence of epilepsy-specific voltage maps on scalp electroencephalography correlated with haemodynamic changes and could help localize the epileptic focus. In 23 patients with focal epilepsy, we built epilepsy-specific electroencephalographic voltage maps using averaged interictal epileptiform discharges recorded during long-term clinical monitoring outside the scanner and computed the correlation of this map with the electroencephalographic recordings in the scanner for each time frame. The time course of this correlation coefficient was used as a regressor for functional magnetic resonance imaging analysis to map haemodynamic changes related to these epilepsy-specific maps (topography-related haemodynamic changes). The method was first validated in five patients with significant haemodynamic changes correlated to interictal epileptiform discharges on conventional analysis. We then applied the method to 18 patients who had inconclusive simultaneous electroencephalography and functional magnetic resonance imaging studies due to the absence of interictal epileptiform discharges or absence of significant correlated haemodynamic changes. The concordance of the results with subsequent intracranial electroencephalography and/or resection area in patients who were seizure free after surgery was assessed. In the validation group, haemodynamic changes correlated to voltage maps were similar to those obtained with conventional analysis in 5/5 patients. In 14/18 patients (78%) with previously inconclusive studies, scalp maps related to epileptic activity had haemodynamic correlates even when no interictal epileptiform discharges were detected during simultaneous recordings. Haemodynamic changes correlated to voltage maps were spatially concordant with intracranial electroencephalography or with the resection area. We found better concordance in patients with lateral temporal and extratemporal neocortical epilepsy compared to medial/polar temporal lobe epilepsy, probably due to the fact that electroencephalographic voltage maps specific to lateral temporal and extratemporal epileptic activity are more dissimilar to maps of physiological activity. Our approach significantly increases the yield of simultaneous electroencephalography and functional magnetic resonance imaging to localize the epileptic focus non-invasively, allowing better targeting for surgical resection or implantation of intracranial electrode arrays.
PLOS ONE | 2009
Anna Elisabetta Vaudano; Helmut Laufs; Stefan J. Kiebel; David W. Carmichael; Khalid Hamandi; Maxime Guye; R Thornton; Roman Rodionov; K. J. Friston; John S. Duncan; Louis Lemieux
Background Generalised spike wave (GSW) discharges are the electroencephalographic (EEG) hallmark of absence seizures, clinically characterised by a transitory interruption of ongoing activities and impaired consciousness, occurring during states of reduced awareness. Several theories have been proposed to explain the pathophysiology of GSW discharges and the role of thalamus and cortex as generators. In this work we extend the existing theories by hypothesizing a role for the precuneus, a brain region neglected in previous works on GSW generation but already known to be linked to consciousness and awareness. We analysed fMRI data using dynamic causal modelling (DCM) to investigate the effective connectivity between precuneus, thalamus and prefrontal cortex in patients with GSW discharges. Methodology and Principal Findings We analysed fMRI data from seven patients affected by Idiopathic Generalized Epilepsy (IGE) with frequent GSW discharges and significant GSW-correlated haemodynamic signal changes in the thalamus, the prefrontal cortex and the precuneus. Using DCM we assessed their effective connectivity, i.e. which region drives another region. Three dynamic causal models were constructed: GSW was modelled as autonomous input to the thalamus (model A), ventromedial prefrontal cortex (model B), and precuneus (model C). Bayesian model comparison revealed Model C (GSW as autonomous input to precuneus), to be the best in 5 patients while model A prevailed in two cases. At the group level model C dominated and at the population-level the p value of model C was ∼1. Conclusion Our results provide strong evidence that activity in the precuneus gates GSW discharges in the thalamo-(fronto) cortical network. This study is the first demonstration of a causal link between haemodynamic changes in the precuneus - an index of awareness - and the occurrence of pathological discharges in epilepsy.
NeuroImage | 2009
Serge Vulliemoz; R Thornton; Roman Rodionov; David W. Carmichael; Maxime Guye; Samden Lhatoo; Andrew W. McEvoy; Laurent Spinelli; Christoph M. Michel; John S. Duncan; Louis Lemieux
Simultaneous EEG–fMRI acquisitions in patients with epilepsy often reveal distributed patterns of Blood Oxygen Level Dependant (BOLD) change correlated with epileptiform discharges. We investigated if electrical source imaging (ESI) performed on the interictal epileptiform discharges (IED) acquired during fMRI acquisition could be used to study the dynamics of the networks identified by the BOLD effect, thereby avoiding the limitations of combining results from separate recordings. Nine selected patients (13 IED types identified) with focal epilepsy underwent EEG–fMRI. Statistical analysis was performed using SPM5 to create BOLD maps. ESI was performed on the IED recorded during fMRI acquisition using a realistic head model (SMAC) and a distributed linear inverse solution (LAURA). ESI could not be performed in one case. In 10/12 remaining studies, ESI at IED onset (ESIo) was anatomically close to one BOLD cluster. Interestingly, ESIo was closest to the positive BOLD cluster with maximal statistical significance in only 4/12 cases and closest to negative BOLD responses in 4/12 cases. Very small BOLD clusters could also have clinical relevance in some cases. ESI at later time frame (ESIp) showed propagation to remote sources co-localised with other BOLD clusters in half of cases. In concordant cases, the distance between maxima of ESI and the closest EEG–fMRI cluster was less than 33 mm, in agreement with previous studies. We conclude that simultaneous ESI and EEG–fMRI analysis may be able to distinguish areas of BOLD response related to initiation of IED from propagation areas. This combination provides new opportunities for investigating epileptic networks.
Annals of Neurology | 2011
R Thornton; S Vulliemoz; Roman Rodionov; David W. Carmichael; Umair J. Chaudhary; Beate Diehl; Helmut Laufs; Christian Vollmar; Andrew W. McEvoy; Matthew C. Walker; Fabrice Bartolomei; Maxime Guye; Patrick Chauvel; John S. Duncan; Louis Lemieux
Surgical treatment of focal epilepsy in patients with focal cortical dysplasia (FCD) is most successful if all epileptogenic tissue is resected. This may not be evident on structural magnetic resonance imaging (MRI), so intracranial electroencephalography (icEEG) is needed to delineate the seizure onset zone (SOZ). EEG‐functional MRI (fMRI) can reveal interictal discharge (IED)‐related hemodynamic changes in the irritative zone (IZ). We assessed the value of EEG‐fMRI in patients with FCD‐associated focal epilepsy by examining the relationship between IED‐related hemodynamic changes, icEEG findings, and postoperative outcome.
NeuroImage | 2010
David W. Carmichael; John S. Thornton; Roman Rodionov; R Thornton; Andrew W. McEvoy; Roger J. Ordidge; Philip J. Allen; Louis Lemieux
In epilepsy patients who have electrodes implanted in their brains as part of their pre-surgical assessment, simultaneous intracranial EEG and fMRI (icEEG-fMRI) may provide important localising information and improve understanding of the underlying neuropathology. However, patient safety during icEEG-fMRI has not been addressed. Here the potential health hazards associated with icEEG-fMRI were evaluated theoretically and the main risks identified as: mechanical forces on electrodes from transient magnetic effects, tissue heating due to interaction with the pulsed RF fields and tissue stimulation due to interactions with the switched magnetic gradient fields. These potential hazards were examined experimentally in vitro on a Siemens 3 T Trio, 1.5 T Avanto and a GE 3 T Signa Excite scanner using a Brain Products MR compatible EEG system. No electrode flexion was observed. Temperature measurements demonstrated that heating well above guideline limits can occur. However heating could be kept within safe limits (<1.0 degrees C) by using a head transmit RF coil, ensuring EEG cable placement to exit the RF coil along its central z-axis, using specific EEG cable lengths and limiting MRI sequence specific absorption rates (SARs). We found that the risk of tissue damage due to RF-induced heating is low provided implant and scanner specific SAR limits are observed with a safety margin used to account for uncertainties (e.g. in scanner-reported SAR). The observed scanner gradient switching induced current (0.08 mA) and charge density (0.2 microC/cm(2)) were well within safety limits (0.5 mA and 30 microC/cm(2), respectively). Site-specific testing and a conservative approach to safety are required to avoid the risk of adverse events.
NeuroImage | 2010
R Thornton; Roman Rodionov; Helmut Laufs; S Vulliemoz; A. Vaudano; David W. Carmichael; S Cannadathu; Maxime Guye; Andrew W. McEvoy; Samden Lhatoo; Fabrice Bartolomei; Patrick Chauvel; Beate Diehl; F. De Martino; R.D.C. Elwes; Matthew C. Walker; John S. Duncan; Louis Lemieux
BACKGROUNDnSimultaneous EEG-fMRI can reveal haemodynamic changes associated with epileptic activity which may contribute to understanding seizure onset and propagation.nnnMETHODSnNine of 83 patients with focal epilepsy undergoing pre-surgical evaluation had seizures during EEG-fMRI and analysed using three approaches, two based on the general linear model (GLM) and one using independent component analysis (ICA): The results were compared with intracranial EEG.nnnRESULTSnThe canonical GLM analysis revealed significant BOLD signal changes associated with seizures on EEG in 7/9 patients, concordant with the seizure onset zone in 4/7. The Fourier GLM analysis revealed changes in BOLD signal corresponding with the results of the canonical analysis in two patients. ICA revealed components spatially concordant with the seizure onset zone in all patients (8/9 confirmed by intracranial EEG).nnnCONCLUSIONnIctal EEG-fMRI visualises plausible seizure related haemodynamic changes. The GLM approach to analysing EEG-fMRI data reveals localised BOLD changes concordant with the ictal onset zone when scalp EEG reflects seizure onset. ICA provides additional information when scalp EEG does not accurately reflect seizures and may give insight into ictal haemodynamics.
Journal of Magnetic Resonance Imaging | 2008
David W. Carmichael; John S. Thornton; Roman Rodionov; R Thornton; Andrew W. McEvoy; Philip J. Allen; Louis Lemieux
To investigate heating during postimplantation localization of intracranial electroencephalograph (EEG) electrodes by MRI.
NeuroImage | 2010
Serge Vulliemoz; Roman Rodionov; David W. Carmichael; R Thornton; Maxime Guye; Samden Lhatoo; Christoph M. Michel; John S. Duncan; Louis Lemieux
INTRODUCTIONnEEG-correlated fMRI (EEG-fMRI) studies can reveal haemodynamic changes associated with Interictal Epileptic Discharges (IED). Methodological improvements are needed to increase sensitivity and specificity for localising the epileptogenic zone. We investigated whether the estimated EEG source activity improved models of the BOLD changes in EEG-fMRI data, compared to conventional << event-related >> designs based solely on the visual identification of IED.nnnMETHODSnTen patients with pharmaco-resistant focal epilepsy underwent EEG-fMRI. EEG Source Imaging (ESI) was performed on intra-fMRI averaged IED to identify the irritative zone. The continuous activity of this estimated IED source (cESI) over the entire recording was used for fMRI analysis (cESI model). The maps of BOLD signal changes explained by cESI were compared to results of the conventional IED-related model.nnnRESULTSnESI was concordant with non-invasive data in 13/15 different types of IED. The cESI model explained significant additional BOLD variance in regions concordant with video-EEG, structural MRI or, when available, intracranial EEG in 10/15 IED. The cESI model allowed better detection of the BOLD cluster, concordant with intracranial EEG in 4/7 IED, compared to the IED model. In 4 IED types, cESI-related BOLD signal changes were diffuse with a pattern suggestive of contamination of the source signal by artefacts, notably incompletely corrected motion and pulse artefact. In one IED type, there was no significant BOLD change with either model.nnnCONCLUSIONnContinuous EEG source imaging can improve the modelling of BOLD changes related to interictal epileptic activity and this may enhance the localisation of the irritative zone.
Brain | 2012
Umair J. Chaudhary; David W. Carmichael; Roman Rodionov; R Thornton; Phillipa Bartlett; Serge Vulliemoz; Caroline Micallef; Andrew W. McEvoy; Beate Diehl; Matthew C. Walker; John S. Duncan; Louis Lemieux
Ictal patterns on scalp-electroencephalography are often visible only after propagation, therefore rendering localization of the seizure onset zone challenging. We hypothesized that mapping haemodynamic changes before and during seizures using simultaneous video-electroencephalography and functional imaging will improve the localization of the seizure onset zone. Fifty-five patients with ≥2 refractory focal seizures/day, and who had undergone long-term video-electroencephalography monitoring were included in the study. Preictal (30 s immediately preceding the electrographic seizure onset) and ictal phases, ictal-onset; ictalestablished and late ictal, were defined based on the evolution of the electrographic pattern and clinical semiology. The functional imaging data were analysed using statistical parametric mapping to map ictal phase-related haemodynamic changes consistent across seizures. The resulting haemodynamic maps were overlaid on co-registered anatomical scans, and the spatial concordance with the presumed and invasively defined seizure onset zone was determined. Twenty patients had typical seizures during functional imaging. Seizures were identified on video-electroencephalography in 15 of 20, on electroencephalography alone in two and on video alone in three patients. All patients showed significant ictal-related haemodynamic changes. In the six cases that underwent invasive evaluation, the ictal-onset phase-related maps had a degree of concordance with the presumed seizure onset zone for all patients. The most statistically significant haemodynamic cluster within the presumed seizure onset zone was between 1.1 and 3.5 cm from the invasively defined seizure onset zone, which was resected in two of three patients undergoing surgery (Class I post-surgical outcome) and was not resected in one patient (Class III post-surgical outcome). In the remaining 14 cases, the ictal-onset phase-related maps had a degree of concordance with the presumed seizure onset zone in six of eight patients with structural-lesions and five of six non-lesional patients. The most statistically significant haemodynamic cluster was localizable at sub-lobar level within the presumed seizure onset zone in six patients. The degree of concordance of haemodynamic maps was significantly better (P < 0.05) for the ictal-onset phase [entirely concordant/concordant plus (13/20; 65%) + some concordance (4/20; 20%) = 17/20; 85%] than ictal-established [entirely concordant/concordant plus (5/13; 38%) + some concordance (4/13; 31%) = 9/13; 69%] and late ictal [concordant plus (1/9; 11%) + some concordance (4/9; 44%) = 5/9; 55%] phases. Ictal propagation-related haemodynamic changes were also seen in symptomatogenic areas (9/20; 45%) and the default mode network (13/20; 65%). A common pattern of preictal changes was seen in 15 patients, starting between 98 and 14 s before electrographic seizure onset, and the maps had a degree of concordance with the presumed seizure onset zone in 10 patients. In conclusion, preictal and ictal haemodynamic changes in refractory focal seizures can non-invasively localize seizure onset at sub-lobar/gyral level when ictal scalp-electroencephalography is not helpful.
NeuroImage | 2012
Umair J. Chaudhary; Roman Rodionov; David W. Carmichael; R Thornton; John S. Duncan; Louis Lemieux
RATIONALEnTo improve the sensitivity and specificity of simultaneous electroencephalography and functional magnetic resonance imaging (EEG-fMRI) it is prudent to devise modelling strategies explaining the residual variance. The purpose of this study is to investigate the potential value of including additional regressors for physiological activities, derived from video-EEG, in the modelling of haemodynamic patterns linked to interictal epileptiform discharges (IEDs) using simultaneously recorded video-EEG-fMRI.nnnMETHODSnTen patients with IED (focal epilepsy: 6, idiopathic generalized epilepsy (IGE):4) were studied. BOLD-sensitive fMRI images were acquired on a 3T MRI scanner. 64-channel EEG was recorded using MR-compatible system. A custom made, dual-video-camera system synchronised with EEG was used to record video simultaneously. IEDs and physiological activities were identified and labelled on video-EEG using Brain Analyzer2. fMRI time-series data were pre-processed and analysed using SPM5 software. Two general linear models (GLM) were created; GLM1: IEDs were convolved with the canonical haemodynamic response function and its derivatives. Realignment parameters and pulse regressors were included in the design matrix as confounds, GLM2: GLM1 and additional regressors identified on video-EEG including: eye blinks, hand or foot movement, chewing and swallowing were also included in the design matrix. SPM [F] maps (p<0.05, corrected for family wise error and p<0.001, uncorrected) were generated for both models. We compared the resulting blood oxygen level dependent (BOLD) maps for cluster size, statistical significance and degree of concordance with the irritative zone.nnnRESULTSnBOLD changes relating to physiological activities were generally seen in expected brain areas. In patients with focal epilepsy, the extent and Z-score of the IED-related global maximum BOLD clusters increased in 4/6 patients and additional IED-related BOLD clusters were observed in 3/6 patients for GLM2. Also, the degree of concordance of IED-related maps with irritative zone improved for one patient for GLM2 and was unchanged for the other cases. In patients with IGE, the size and statistical significance for global maximum and other BOLD clusters increased in 2/4 patients. We conclude that the inclusion of additional regressors, derived from video based information, in the design matrix explains a greater amount of variance and can reveal additional IED-related BOLD clusters which may be part of the epileptic networks.