Rafiz Abdul Rani
Universiti Teknologi MARA
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Rafiz Abdul Rani.
Intestinal Research | 2016
Rafiz Abdul Rani; Raja Affendi Raja Ali; Yeong Yeh Lee
Irritable bowel syndrome (IBS), a common gastrointestinal disorder involving the gut-brain axis, and inflammatory bowel disease (IBD), a chronic relapsing inflammatory disorder, are both increasing in incidence and prevalence in Asia. Both have significant overlap in terms of symptoms, pathophysiology, and treatment, suggesting the possibility of IBS and IBD being a single disease entity albeit at opposite ends of the spectrum. We examined the similarities and differences in IBS and IBD, and offer new thoughts and approaches to the disease paradigm.
International journal of hepatology | 2018
Sumitro Kosasih; Wong Zhi Qin; Rafiz Abdul Rani; Nazefah Abd Hamid; Ngiu Chai Soon; Shamsul Azhar Shah; Yazmin Yaakob; Raja Affendi Raja Ali
Backgrounds The aim of this study was to appraise the relationship between serum fragmented cytokeratin-18(CK-18), controlled attenuation parameter (CAP), and liver steatosis assessed by ultrasound (US) in nonalcoholic fatty liver disease (NAFLD) patients. Methods Patients who underwent abdominal US were recruited, followed with measurement of CAP using Fibroscan® and serum fragmented CK-18 using enzyme-linked immunosorbent assay. The degree of liver steatosis assessed by US was categorized into mild (S1), moderate (S2), and severe (S3). Results A total of 109 patients were included in our study. CAP and fragmented CK-18 level were significantly correlated with liver steatosis grade with rs = 0.56 and 0.68, p=0.001, respectively. NAFLD Fibrosis Score was poorly correlated with liver steatosis grade (rs=-0.096, p=0.318). Using fragmented CK-18 level, area under receiver operating characteristic (AUROC) curves for S≥2 and S≥3 were excellent (0.82 and 0.84, respectively). Using CAP, AUROC curves for detection of S≥2 and S≥3 were good (0.76, 0.77, respectively). We also proposed cut-off value of CAP to detect S≥2 and S≥3 to be 263 and 319db/m, respectively, and fragmented CK-18 level to detect S≥2 and S≥3 (194 and 294 U/L, respectively). Conclusions Both the fragmented CK-18 level and the CAP, but not NAFLD Fibrosis Score, were well correlated with hepatic steatosis grade as assessed by US.
Endoscopy International Open | 2018
Naohisa Yoshida; Yuji Naito; Ritsu Yasuda; Takaaki Murakami; Ryohei Hirose; Kiyoshi Ogiso; Yutaka Inada; Hideyuki Konishi; Rafiz Abdul Rani; Mitsuo Kishimoto; Eiichi Konishi; Masayoshi Nakanishi; Yoshito Itoh
Background and study aims Severe fibrosis poses a challenge in colorectal endoscopic submucosal dissection (ESD). Recently, the pocket-creation method (PCM) has been developed for overcoming various difficulties of ESD. A specific tapered hood is used for adequate traction in the PCM, and endoscopic operability becomes stable in the pocket. In this study, we investigated the efficacy of the PCM in ESD for cases with severe fibrosis. Patients and methods We retrospectively reviewed 1000 consecutive colorectal ESD cases (April 2006 to January 2017). Since 2016, the PCM was performed in 58 cases. The indications for ESD included (1) tumors ≥ 20 mm in size diagnosed as intramucosal cancer or high-grade dysplasia and part of T1a cancer using magnifying endoscopic examinations and (2) tumors that appeared impossible to resect with endoscopic mucosal resection because of suspected fibrosis. We identified 120 cases with severe fibrosis and compared them to cases without severe fibrosis. Additionally, the 120 severe fibrosis cases were divided into the PCM and non-PCM groups. En bloc resection, procedure time, discontinuation, and complications were analyzed between these 2 groups. Results Among all 1000 ESDs, severe fibrosis and discontinuation rates were 12.0 % (120 cases) and 1.8 % (18 cases), respectively. Regarding the comparison between cases with severe fibrosis and with no severe fibrosis, there were significant differences about en bloc resection rate (78.3 % vs. 95.7 %, P < 0.001), discontinuance rate (12.5 % vs. 0.3 %, P < 0.001), and perforation rate (8.3 % vs. 2.6 %, P = 0.001). Among the 120 cases with severe fibrosis, 21 and 99 cases were in the PCM and non-PCM groups, respectively. The PCM group had a higher en bloc resection rate (95.2 vs. 74.7, P = 0.03), a shorter mean procedure time (min) (79.6 ± 26.5 vs. 118.8 ± 71.0, P = 0.001), and no cases of discontinuation. An analysis of the interobserver agreement for the diagnosis of severe fibrosis among the 3 endoscopists showed kappa values of > 0.6. Conclusions In cases with severe fibrosis, the PCM with ESD improved en bloc resection rates and shortened the procedure time compared to the conventional non-PCM method. Additionally, the PCM reduced the discontinuation rate.
Case Reports in Gastroenterology | 2018
Naohisa Yoshida; Yuji Naito; Takaaki Murakami; Kiyoshi Ogiso; Ryohei Hirose; Yutaka Inada; Mitsuo Kishimoto; Rafiz Abdul Rani; Yoshito Itoh
Cold snare polypectomy (CSP) should be performed for benign lesions, though an accurate diagnosis is sometimes difficult with only white light observation. Irregular findings by narrow-band imaging (NBI) are useful for differentiating malignant lesions from benign lesions, and cases with this finding are not expected for CSP. We present a diminutive T1 cancer resected by CSP as a reflection case. A 68-year-old man underwent colonoscopy for surveillance after polypectomy. A reddish polyp 4 mm in size was detected at the rectum. White light observation showed no depression, but a slight, heterogeneous color change. NBI magnification showed irregular vessel and surface patterns. The polyp was diagnosed as intramucosal cancer. Even though cancerous lesions are regularly resected by endoscopic mucosal resection (EMR), this polyp was resected by CSP in daycare surgery because the patient requested not to be treated by EMR but by CSP, which needed an admission to our institution. The surgeon thought the polyp could be completely resected by CSP. It was thoroughly resected, and a histological examination showed submucosal cancer with a positive vertical margin. Additional surgical resection was not accepted by the patient, since he had received total gastrectomy for gastric cancer and a right hemicolectomy for colonic cancer in the past 7 years. He underwent follow-up colonoscopy 2 months after the CSP. Although there were no recurrent endoscopic findings, endoscopic submucosal dissection was performed to the scar area. The histological examination showed no residual tumor. In conclusion, CSP should only be adopted for benign cases, as cancerous lesions have a possibility for invading the submucosa, like in our case.
Endoscopy International Open | 2017
Naohisa Yoshida; Yuji Naito; Ritsu Yasuda; Takaaki Murakami; Kiyoshi Ogiso; Ryohei Hirose; Yutaka Inada; Osamu Dohi; Tetsuya Okayama; Kazuhiro Kamada; Kazuhiko Uchiyama; Takeshi Ishikawa; Osamu Handa; Hideyuki Konishi; Rafiz Abdul Rani; Yoshito Itoh
Background and study aims Water drop adhesions (WDA) impair endoscopic view during gastrointestinal endoscopy. We developed a novel lens cleaner designed using two types of harmLess surfactants and it is reported to be useful for preventing lens cloudiness during colorectal ESD. In the current study, we examined the ability of it for preventing and removing WDA. Patients and methods During laboratory experiments, the cleaner (Cleash; Fujifilm Co., Tokyo, Japan and Nagase Medicals Co., Hyogo, Japan) was applied to the endoscopic lens and an air/water device (AWD) (water 200 mL, dimethicone 1 mL, Cleash 1 mL). The endoscope was submerged in water 100 times for 5 cycles. Rates of WDA were calculated for various groups (lens and AWD with or without Cleash) and compared to a normal cleaner (SL cleaner). During clinical research, 30 colonoscopies and 30 esophagogastroduodenoscopies were analyzed. For the Cleash group, the cleaner was applied to both lens and AWD. The numbers of WDA and WDA with non-rapid removal were calculated, compared to those of the SL cleaner group. Results The mean WDA rate for the Cleash setting (lens: Cleash; AWD: Cleash) was 11.0 %, which was significantly lower than other settings (lens: SL cleaner; AWD: water, 31.0 %; P < 0.001) (lens: Cleash; AWD: water, 19.0 %; P < 0.001). Clinical research of colonoscopies indicated that the numbers of WDA (number/15 sec) and WDA with non-rapid removal were 0.38 and 0.17 for the Cleash group and 0.91 and 0.46 for the SL cleaner groups ( P < 0.001, P < 0.001). For esophagogastroduodenoscopies, the results were 0.47 and 0.24 for the Cleash group and 0.54 and 0.42 for the SL cleaner group ( P = 0.72, P = 0.018). Conclusion A clear and beautiful image without WDA is useful not only for routine endoscopy but also, more importantly, for magnifying endoscopy and other endoscopic treatments. The use of Cleash to lens and AWD showed positive results for preventing and removing WDA during laboratory experiments and clinical research involving CS. Additionally, it also showed positive results for the removal of WDA during EGD.
Digestive Endoscopy | 2012
Chai Soon Ngiu; Rafiz Abdul Rani; Soo Fin Low
In the study, colonoscopies were performed by an experienced endoscopist without sedating the patient.The discomfort of patients in corset-arm was significantly reduced compared to that of the conventional-arm patients.However, in theToros et al.methodology,potential confounding factors need to be clarified.There was no specification regarding air or carbon dioxide insufflation during colonoscopy. It is wellknown that carbon dioxide insufflation reduces the level of discomfort and pain. The amount of gas insufflation or the degree of abdominal distension should be quantified, as increased bowel distension will also cause pain.Furthermore, it would be interesting to assess recovery period in both the corset-arm group and the conventional-arm group. Studies have shown abdominal distension or bloating causes prolonged recovery and delays discharge. 2,3 Documentation of the length of colonoscopy from anus to cecum should be reported as well, as this is an important indicator of looping and mesenteric stretching. 4
Annals of Translational Medicine | 2017
Naohisa Yoshida; Yuji Naito; Takaaki Murakami; Ryohei Hirose; Kiyoshi Ogiso; Yutaka Inada; Rafiz Abdul Rani; Mitsuo Kishimoto; Masayoshi Nakanishi; Yoshito Itoh
International Journal of Colorectal Disease | 2017
Naohisa Yoshida; Yuji Naito; Ritsu Yasuda; Takaaki Murakami; Ryohei Hirose; Kiyoshi Ogiso; Yutaka Inada; Osamu Dohi; Kazuhiro Kamada; Kazuhiko Uchiyama; Osamu Handa; Hideyuki Konishi; Rafiz Abdul Rani; Mitsuo Kishimoto; Eiichi Konishi; Yoshito Itoh
Gastrointestinal Endoscopy | 2018
Naohisa Yoshida; Yuji Naito; Takaaki Murakami; Ryohei Hirose; Yutaka Inada; Osamu Dohi; Kazuhiro Kamada; Kazuhiko Uchiyama; Osamu Handa; Hideyuki Konishi; Rafiz Abdul Rani; Yoshito Itoh
Gastrointestinal Endoscopy | 2018
Naohisa Yoshida; Yuji Naito; Ritsu Yasuda; Takaaki Murakami; Ryohei Hirose; Yutaka Inada; Osamu Dohi; Kazuhiro Kamada; Kazuhiko Uchiyama; Osamu Handa; Hideyuki Konishi; Rafiz Abdul Rani; Yoshito Itoh