Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Rajan Kanhirodan is active.

Publication


Featured researches published by Rajan Kanhirodan.


IEEE Journal of Selected Topics in Quantum Electronics | 2014

Sparse Recovery Methods Hold Promise for Diffuse Optical Tomographic Image Reconstruction

Jaya Prakash; Calvin B. Shaw; Rakesh Manjappa; Rajan Kanhirodan; Phaneendra K. Yalavarthy

The sparse recovery methods utilize the ℓp-norm-based regularization in the estimation problem with 0 ≤ p ≤ 1. These methods have a better utility when the number of independent measurements are limited in nature, which is a typical case for diffuse optical tomographic image reconstruction problem. These sparse recovery methods, along with an approximation to utilize the ℓ0-norm, have been deployed for the reconstruction of diffuse optical images. Their performance was compared systematically using both numerical and gelatin phantom cases to show that these methods hold promise in improving the reconstructed image quality.


Optics Express | 2011

Ultrasound modulated optical tomography: Young’s modulus of the insonified region from measurement of natural frequency of vibration

R. Sriram Chandran; Debasish Roy; Rajan Kanhirodan; Ram Mohan Vasu; C. Usha Devi

We demonstrate a method to recover the Youngs modulus (E) of a tissue-mimicking phantom from measurements of ultrasound modulated optical tomography (UMOT). The object is insonified by a dual-beam, confocal ultrasound transducer (US) oscillating at frequencies f₀ and f₀ + Δf and the variation of modulation depth (M) in the autocorrelation of light traversed through the focal region of the US transducer against Δf is measured. From the dominant peaks observed in the above variation, the natural frequencies of the insonified region associated with the vibration along the US transducer axis are deduced. A consequence of the above resonance is that the speckle fluctuation at the resonance frequency has a higher signal-to-noise to ratio (SNR). From these natural frequencies and the associated eigenspectrum of the oscillating object, Youngs modulus (E) of the material in the focal region is recovered. The working of this method is confirmed by recovering E in the case of three tissue-mimicking phantoms of different elastic modulus values.


Applied Optics | 2006

Quantitative flow visualization in supersonic jets through tomographic inversion of wavefronts estimated through shadow casting

Hemanth Thayyullathil; R. Mohan Vasu; Rajan Kanhirodan

We present a simple method with which to reconstruct wavefronts that are transilluminating supersonic jets through measurement of their local slopes. The wavefront slopes are measured in two orthogonal directions by use of the average displacements suffered by a random-dot pattern in its shadow cast by the wavefront in front of it. A smooth wavefront is estimated from its measured slopes by a least-squares curve fitting technique. The calculated wavefront distortion is tomographically inverted to yield the density distributions of the object. The results are comparable to that obtained by use of a phase-retrieval algorithm from axial intensity transport measurements.


Medical Physics | 2015

Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters.

Rakesh Manjappa; Sharath Makki S; Rajesh Kumar; Rajan Kanhirodan

PURPOSE Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. METHODS The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at the inhomogeneities. Jacobs ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. RESULTS The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. CONCLUSIONS The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm reconstructs the dose profiles by estimating refractive indices of multiple inhomogeneities having different refractive indices and optical densities embedded in the dosimeter. This is achieved by tracking the path of the ray that traverses through the dosimeter. Extensive simulation studies have been carried out and results are found to be matching that of experimental results.


Journal of The Optical Society of America A-optics Image Science and Vision | 2014

Diffraction tomography from intensity measurements: an evolutionary stochastic search to invert experimental data

Jem Teresa; Mamatha Venugopal; Debasish Roy; Ram Mohan Vasu; Rajan Kanhirodan

We develop iterative diffraction tomography algorithms, which are similar to the distorted Born algorithms, for inverting scattered intensity data. Within the Born approximation, the unknown scattered field is expressed as a multiplicative perturbation to the incident field. With this, the forward equation becomes stable, which helps us compute nearly oscillation-free solutions that have immediate bearing on the accuracy of the Jacobian computed for use in a deterministic Gauss-Newton (GN) reconstruction. However, since the data are inherently noisy and the sensitivity of measurement to refractive index away from the detectors is poor, we report a derivative-free evolutionary stochastic scheme, providing strictly additive updates in order to bridge the measurement-prediction misfit, to arrive at the refractive index distribution from intensity transport data. The superiority of the stochastic algorithm over the GN scheme for similar settings is demonstrated by the reconstruction of the refractive index profile from simulated and experimentally acquired intensity data.


Journal of The Optical Society of America A-optics Image Science and Vision | 2012

Practical fully three-dimensional reconstruction algorithms for diffuse optical tomography

Samir Kumar Biswas; Rajan Kanhirodan; Ram Mohan Vasu; Debasish Roy

We have developed an efficient fully three-dimensional (3D) reconstruction algorithm for diffuse optical tomography (DOT). The 3D DOT, a severely ill-posed problem, is tackled through a pseudodynamic (PD) approach wherein an ordinary differential equation representing the evolution of the solution on pseudotime is integrated that bypasses an explicit inversion of the associated, ill-conditioned system matrix. One of the most computationally expensive parts of the iterative DOT algorithm, the reevaluation of the Jacobian in each of the iterations, is avoided by using the adjoint-Broyden update formula to provide low rank updates to the Jacobian. In addition, wherever feasible, we have also made the algorithm efficient by integrating along the quadratic path provided by the perturbation equation containing the Hessian. These algorithms are then proven by reconstruction, using simulated and experimental data and verifying the PD results with those from the popular Gauss-Newton scheme. The major findings of this work are as follows: (i) the PD reconstructions are comparatively artifact free, providing superior absorption coefficient maps in terms of quantitative accuracy and contrast recovery; (ii) the scaling of computation time with the dimension of the measurement set is much less steep with the Jacobian update formula in place than without it; and (iii) an increase in the data dimension, even though it renders the reconstruction problem less ill conditioned and thus provides relatively artifact-free reconstructions, does not necessarily provide better contrast property recovery. For the latter, one should also take care to uniformly distribute the measurement points, avoiding regions close to the source so that the relative strength of the derivatives for measurements away from the source does not become insignificant.


international conference on industrial technology | 2006

Design of a FIR Filter for Image Restoration using Principal Component Neural Networks

Pradeep Kumar Gupta; Rajan Kanhirodan

The neural network finds its application in many image denoising applications because of its inherent characteristics such as nonlinear mapping and self-adaptiveness. The design of filters largely depends on the a-priori knowledge about the type of noise. Due to this, standard filters are application and image specific. Widely used filtering algorithms reduce noisy artifacts by smoothing. However, this operation normally results in smoothing of the edges as well. On the other hand, sharpening filters enhance the high frequency details making the image non-smooth. An integrated general approach to design a finite impulse response filter based on principal component neural network (PCNN) is proposed in this study for image filtering, optimized in the sense of visual inspection and error metric. This algorithm exploits the inter-pixel correlation by iteratively updating the filter coefficients using PCNN. This algorithm performs optimal smoothing of the noisy image by preserving high and low frequency features. Evaluation results show that the proposed filter is robust under various noise distributions. Further, the number of unknown parameters is very few and most of these parameters are adaptively obtained from the processed image.


Review of Scientific Instruments | 2016

Region-of-interest diffuse optical tomography system

Manob Jyoti Saikia; Rajan Kanhirodan

Diffuse optical tomography (DOT) using near-infrared light is a promising tool for non-invasive imaging of deep tissue. This technique is capable of quantitative reconstruction of absorption (μa) and scattering coefficient (μs) inhomogeneities in the tissue. The rationale for reconstructing the optical property map is that the absorption coefficient variation provides diagnostic information about metabolic and disease states of the tissue. The aim of DOT is to reconstruct the internal tissue cross section with good spatial resolution and contrast from noisy measurements non-invasively. We develop a region-of-interest scanning system based on DOT principles. Modulated light is injected into the phantom/tissue through one of the four light emitting diode sources. The light traversing through the tissue gets partially absorbed and scattered multiple times. The intensity and phase of the exiting light are measured using a set of photodetectors. The light transport through a tissue is diffusive in nature and is modeled using radiative transfer equation. However, a simplified model based on diffusion equation (DE) can be used if the system satisfies following conditions: (a) the optical parameter of the inhomogeneity is close to the optical property of the background, and (b) μs of the medium is much greater than μa (μs > > μa). The light transport through a highly scattering tissue satisfies both of these conditions. A discrete version of DE based on finite element method is used for solving the inverse problem. The depth of probing light inside the tissue depends on the wavelength of light, absorption, and scattering coefficients of the medium and the separation between the source and detector locations. Extensive simulation studies have been carried out and the results are validated using two sets of experimental measurements. The utility of the system can be further improved by using multiple wavelength light sources. In such a scheme, the spectroscopic variation of absorption coefficient in the tissue can be used to arrive at the oxygenation changes in the tissue.


Journal of The Optical Society of America A-optics Image Science and Vision | 2015

Detection and estimation of liquid flow through a pipe in a tissue-like object with ultrasound-assisted diffuse correlation spectroscopy

Sriram R Chandran; G Devaraj; Rajan Kanhirodan; Debasish Roy; Ram Mohan Vasu

Using coherent light interrogating a turbid object perturbed by a focused ultrasound (US) beam, we demonstrate localized measurement of dynamics in the focal region, termed the region-of-interest (ROI), from the decay of the modulation in intensity autocorrelation of light. When the ROI contains a pipe flow, the decay is shown to be sensitive to the average flow velocity from which the mean-squared displacement (MSD) of the scattering centers in the flow can be estimated. While the MSD estimated is seen to be an order of magnitude higher than that obtainable through the usual diffusing wave spectroscopy (DWS) without the US, it is seen to be more accurate as verified by the volume flow estimated from it. It is further observed that, whereas the MSD from the localized measurement grows with time as τ(α) with α≈1.65, without using the US, α is seen to be much less. Moreover, with the local measurement, this super-diffusive nature of the pipe flow is seen to persist longer, i.e., over a wider range of initial τ, than with the unassisted DWS. The reason for the super-diffusivity of flow, i.e., α<2, in the ROI is the presence of a fluctuating (thermodynamically nonequilibrium) component in the dynamics induced by the US forcing. Beyond this initial range, both methods measure MSDs that rise linearly with time, indicating that ballistic and near-ballistic photons hardly capture anything beyond the background Brownian motion.


conference on industrial electronics and applications | 2006

A New FIR Filter for Image Restoration

Imteyaz Ahmad; Partha Pratim Mondal; Rajan Kanhirodan

Image filtering techniques have potential applications in biomedical image processing such as image restoration and image enhancement. The potential of traditional filters largely depends on the apriori knowledge about the type of noise corrupting the image. This makes the standard filters to be application specific. For example, the well-known median filter and its variants can remove the salt-and-pepper (or impulse) noise at low noise levels. Each of these methods has its own advantages and disadvantages. In this paper, we have introduced a new finite impulse response (FIR) filter for image restoration where, the filter undergoes a learning procedure. The filter coefficients are adaptively updated based on correlated Hebbian learning. This algorithm exploits the inter pixel correlation in the form of Hebbian learning and hence performs optimal smoothening of the noisy images. The application of the proposed filter on images corrupted with Gaussian noise, results in restorations which are better in quality compared to those restored by average and Wiener filters. The restored image is found to be visually appealing and artifact-free

Collaboration


Dive into the Rajan Kanhirodan's collaboration.

Top Co-Authors

Avatar

Ram Mohan Vasu

Indian Institute of Science

View shared research outputs
Top Co-Authors

Avatar

Debasish Roy

Indian Institute of Science

View shared research outputs
Top Co-Authors

Avatar

Rakesh Manjappa

Indian Institute of Science

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Manob Jyoti Saikia

Indian Institute of Science

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rajesh Kumar

Bhabha Atomic Research Centre

View shared research outputs
Top Co-Authors

Avatar

Samir Kumar Biswas

Indian Institute of Science

View shared research outputs
Top Co-Authors

Avatar

Dibbyan Mazumder

Indian Institute of Science

View shared research outputs
Top Co-Authors

Avatar

Imteyaz Ahmad

Indian Institute of Science

View shared research outputs
Researchain Logo
Decentralizing Knowledge