Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ram Niranjan is active.

Publication


Featured researches published by Ram Niranjan.


Review of Scientific Instruments | 2013

Palm top plasma focus device as a portable pulsed neutron source

R. K. Rout; Ram Niranjan; P K Mishra; Rohit Srivastava; A. M. Rawool; T. C. Kaushik; Satish C. Gupta

Development of a palm top plasma focus device generating (5.2 ± 0.8) × 10(4) neutrons∕pulse into 4π steradians with a pulse width of 15 ± 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 μF capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US


Review of Scientific Instruments | 2011

Note: A portable pulsed neutron source based on the smallest sealed-type plasma focus device.

Ram Niranjan; R K Rout; Prabhat Mishra; Rohit Srivastava; A. M. Rawool; T. C. Kaushik; Satish C. Gupta

10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 μF, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of (3)He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.


Review of Scientific Instruments | 2016

A 109 neutrons/pulse transportable pulsed D-D neutron source based on flexible head plasma focus unit

Ram Niranjan; R. K. Rout; Rohit Srivastava; T. C. Kaushik; Satish C. Gupta

Development and operation of a portable and compact pulsed neutron source based on sealed-type plasma focus (PF) device are reported. The unit is the smallest sealed-type neutron producing PF device. The effective volume of the PF unit is 33 cm(3) only. A compact size single capacitor (4 μF) is used as the energy driver. A battery based power supply unit is used for charging the capacitor and triggering the spark gap. The PF unit is operated at 10 kV (200 J) and at a deuterium gas filling pressure of 8 mb. The device is operated over a time span of 200 days and the neutron emissions have been observed for 200 shots without changing the gas in between the shots. The maximum yield of this device is 7.8 × 10(4) neutrons/pulse. Beyond 200 shots the yield is below the threshold (1050 neutrons/pulse) of our (3)He detector. The neutron energy is evaluated using time of flight technique and the value is (2.49 ± 0.27) MeV. The measured neutron pulse width is (24 ± 5) ns. Multishot and long duration operations envisage the potentiality of such portable device for repetitive mode of operation.


SOLID STATE PHYSICS: Proceedings of the 58th DAE Solid State Physics Symposium 2013 | 2014

Response of nickel surface to pulsed fusion plasma radiations

Ram Niranjan; R. K. Rout; Rohit Srivastava; Y. Chakravarthy; N. N. Patel; P. Alex; Satish C. Gupta

A 17 kJ transportable plasma focus (PF) device with flexible transmission lines is developed and is characterized. Six custom made capacitors are used for the capacitor bank (CB). The common high voltage plate of the CB is fixed to a centrally triggered spark gap switch. The output of the switch is coupled to the PF head through forty-eight 5 m long RG213 cables. The CB has a quarter time-period of 4 μs and an estimated current of 506 kA is delivered to the PF device at 17 kJ (60 μF, 24 kV) energy. The average neutron yield measured using silver activation detector in the radial direction is (7.1 ± 1.4) × 10(8) neutrons/shot over 4π sr at 5 mbar optimum D2 pressure. The average neutron yield is more in the axial direction with an anisotropy factor of 1.33 ± 0.18. The average neutron energies estimated in the axial as well as in the radial directions are (2.90 ± 0.20) MeV and (2.58 ± 0.20) MeV, respectively. The flexibility of the PF head makes it useful for many applications where the source orientation and the location are important factors. The influence of electromagnetic interferences from the CB as well as from the spark gap on applications area can be avoided by putting a suitable barrier between the bank and the PF head.


SOLID STATE PHYSICS: PROCEEDINGS OF THE 57TH DAE SOLID STATE PHYSICS SYMPOSIUM 2012 | 2013

Characterization of pulsed (plasma focus) neutron source with image plate and application to neutron radiography

Sanjay Andola; Ram Niranjan; A. M. Shaikh; R. K. Rout; T. C. Kaushik; Swati Gupta

Nickel based alloys are being projected as suitable materials for some components of the next generation fusion reactor because of compatible thermal, electrical and mechanical properties. Pure nickel material is tested here for possibility of similar application purpose. Nickel samples (> 99.5 % purity) are exposed here to plasma radiations produced due to D-D fusion reaction inside an 11.5 kJ plasma focus device. The changes in the physical properties of the nickel surface at microscopic level which in turn change the mechanical properties are analyzed using scanning electron microscope, optical microscope, glancing incident X-ray diffractometer and Vickers hardness gauge. The results are reported here.


Journal of Applied Physics | 2018

Effect of gas filling pressure and operation energy on ion and neutron emission in a medium energy plasma focus device

Ram Niranjan; R. K. Rout; Rohit Srivastava; T. C. Kaushik

Plasma focus device of Mather type developed in house has been used first time for neutron radiography of different objects. The device gives (1.2±0.3) ×109 neutrons per pulse produced by D-D fusion reaction with a pulse width of 50±5 ns. The method involves exposing sample to be radiographed to thermalized D-D neutrons and recording the image on Fuji-film BAS-ND image plates. The thermal neutron component of the moderated beam was estimated using two image plates: a conventional IP for X-rays and gamma rays, and an IP doped with Gd for detecting neutrons.


Applied Surface Science | 2015

Surface modifications of fusion reactor relevant materials on exposure to fusion grade plasma in plasma focus device

Ram Niranjan; R.K. Rout; Rohit Srivastava; Y. Chakravarthy; P K Mishra; T. C. Kaushik; Satish C. Gupta

The effects of gas filling pressure and operation energy on deuterium ions and neutrons have been studied in a medium energy plasma focus device, MEPF-12. The deuterium gas filling pressure was varied from 1 to 10 mbar at an operation energy of 9.7 kJ. Also, the operation energy was varied from 3.9 to 9.7 kJ at a deuterium gas filling pressure of 4 mbar. Time resolved emission of deuterium ions was measured using a Faraday cup. Simultaneously, time integrated and time resolved emissions of neutrons were measured using a silver activation detector and plastic scintillator detector, respectively. Various characteristics (fluence, peak density, and most probable energy) of deuterium ions were estimated using the Faraday cup signal. The fluence was found to be nearly independent of the gas filling pressure and operation energy, but the peak density and most probable energy of deuterium ions were found to be varying. The neutron yield was observed to be varying with the gas filling pressure and operation energ...


Journal of Radioanalytical and Nuclear Chemistry | 2014

Synthesis and characterization of ammonium molybdophosphate–silica nano-composite (AMP–SiO2) as a prospective sorbent for the separation of 137Cs from nuclear waste

S. V. Ingale; Ramu Ram; P. U. Sastry; P. B. Wagh; Ratanesh Kumar; Ram Niranjan; S. Phapale; R. Tewari; Ashutosh Dash; Satish C. Gupta


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2014

Use of delayed gamma rays for active non-destructive assay of 235U irradiated by pulsed neutron source (plasma focus)

Sanjay Andola; Ram Niranjan; T. C. Kaushik; R.K. Rout; Ashwani Kumar; D.B. Paranjape; Pradeep Kumar; B. S. Tomar; K. L. Ramakumar; Swati Gupta


IJPAP Vol.50(11) [November 2012] | 2012

The smallest plasma accelerator device as a radiation safe repetitive pulsed neutron source

Ram Niranjan; R. K. Rout; Rohit Srivastava; Satish C. Gupta

Collaboration


Dive into the Ram Niranjan's collaboration.

Top Co-Authors

Avatar

Rohit Srivastava

Bhabha Atomic Research Centre

View shared research outputs
Top Co-Authors

Avatar

Satish C. Gupta

Bhabha Atomic Research Centre

View shared research outputs
Top Co-Authors

Avatar

T. C. Kaushik

Bhabha Atomic Research Centre

View shared research outputs
Top Co-Authors

Avatar

R. K. Rout

Bhabha Atomic Research Centre

View shared research outputs
Top Co-Authors

Avatar

A. M. Rawool

Bhabha Atomic Research Centre

View shared research outputs
Top Co-Authors

Avatar

P K Mishra

Bhabha Atomic Research Centre

View shared research outputs
Top Co-Authors

Avatar

R.K. Rout

Bhabha Atomic Research Centre

View shared research outputs
Top Co-Authors

Avatar

Sanjay Andola

Bhabha Atomic Research Centre

View shared research outputs
Top Co-Authors

Avatar

Swati Gupta

Bhabha Atomic Research Centre

View shared research outputs
Top Co-Authors

Avatar

Y. Chakravarthy

Bhabha Atomic Research Centre

View shared research outputs
Researchain Logo
Decentralizing Knowledge