Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ranka Ler is active.

Publication


Featured researches published by Ranka Ler.


Clinical Chemistry | 2008

Use of the Centaur TnI-Ultra Assay for Detection of Myocardial Infarction and Adverse Events in Patients Presenting With Symptoms Suggestive of Acute Coronary Syndrome

Fred S. Apple; Stephen W. Smith; Lesly A. Pearce; Ranka Ler; MaryAnn M. Murakami

BACKGROUND We determined the diagnostic accuracy of the Advia Centaur TnI-Ultra assay for detecting myocardial infarction (MI) and assessing risk of adverse events in patients presenting with ischemic symptoms suggestive of acute coronary syndrome. METHODS We measured cardiac troponin I (cTnI) on admission and 6-24 h after admission (follow-up) in plasma specimens from 371 consecutive patients. The end point was the first of cardiac event or death within 60 days. We estimated survival curves using the Kaplan-Meier method and compared groups with the log rank statistic. RESULTS MI was established in 49 patients (13%). Clinical sensitivities and specificities for MI based on the 99th percentile (0.04 microg/L) were 74% and 84%, respectively, on admission and 94% and 81% at follow-up. ROC curves showed significantly higher accuracy for MI in the follow-up specimen compared with admission (P = 0.001). Overall there were 2 cardiac deaths, 1 noncardiac death, 49 MIs, 7 coronary artery bypass grafts, and 36 percutaneous coronary interventions in 59 patients during follow-up. The event rate in those with cTnI <0.006 microg/L was significantly lower than in groups with cTnI 0.006-0.04 microg/L, >0.04-0.10 microg/L, or >0.10 microg/L (2.8% vs 11.1%, 24.1%, 55.1%, respectively; P <0.0001). Relative risks for the increasing cTnI cutoff groups were 3.9 (95% CI 1.2-13), 8.9 (2.4-34), and 25 (7.3-82) after adjustment for age, diabetes, history of hypertension, previous MI, and estimated glomerular filtration rate. CONCLUSIONS The TnI-Ultra assay is a sensitive, early diagnostic biomarker for MI and an independent predictor of adverse events at any measurable cTnI in patients with symptoms of acute coronary syndrome.


Clinical Chemistry | 2008

Cross-Reactivity of BNP, NT-proBNP, and proBNP in Commercial BNP and NT-proBNP Assays: Preliminary Observations from the IFCC Committee for Standardization of Markers of Cardiac Damage

Kristin Luckenbill; Robert H. Christenson; Allan S. Jaffe; Johannes Mair; Jordi Ordóñez-Llanos; Franca Pagani; Jillian R. Tate; Alan H.B. Wu; Ranka Ler; Fred S. Apple

B-type natriuretic peptide (BNP) is a 32 amino acid cardiac-synthesized hormone that reduces blood pressure and increases sodium excretion (1). Following proteolytic cleavage of proBNP, a 108-amino acid precursor, an N-terminal fragment (NT-proBNP) and BNP are released (2). Increased concentrations of BNP and NT-proBNP can be used clinically to monitor heart failure, but a lack of alignment between commercial BNP and NT-proBNP assays (3) can lead to confusion when clinicians or laboratorians compare results measured for the same analyte on different instruments. Some of this confusion arises from variable assay specificity regarding what peptides are being measured. We studied whether ( a ) BNP assays demonstrated cross-reactivity with NT-proBNP or proBNP, and ( b ) whether NT-proBNP assays demonstrated cross-reactivity with BNP or proBNP, by using 5 commercial BNP and 3 commercial NT-proBNP assays with 2 BNP, 2 NT-proBNP, and 2 proBNP materials. The NPs studied were: Peptide Institute synthetic BNP (aa 77–108), Scios human recombinant BNP (aa 77–108), HyTest human recombinant NT-proBNP (aa 1–76), Roche modified (amidated for stabilization) synthetic NT-proBNP, HyTest human recombinant proBNP (aa 1–108), and Scios glycosylated human recombinant proBNP. BNP assays evaluated were Abbott Architect, Abbott AxSYM, Bayer …


Clinical Chemistry | 2008

Analytical Characteristics of Commercial Cardiac Troponin I and T Immunoassays in Serum from Rats, Dogs, and Monkeys with Induced Acute Myocardial Injury

Fred S. Apple; MaryAnn M. Murakami; Ranka Ler; Dana Walker; Malcolm York

BACKGROUND Information is needed regarding analytical characteristics of cardiac troponin (cTn) assays used in preclinical studies. METHODS We measured cTnI and cTnT in serum from normal animals and animals with induced myocardial injury [Sprague-Dawley (SD) and Wistar rats, beagle dogs, and rhesus (Rh) and cynomolgus (Cy) monkeys]. We evaluated the following assays: for cTnI, Abbott Architect, Bayer Centaur (first and second generation), Beckman Access, DPC Immulite, Dade Dimension, Ortho Vitros ES, Tosoh AIA, and species-specific enzyme immunoassays; for cTnT, Roche Elecsys. RESULTS We found different species-specific responses for the troponin assays evaluated. Abbott, Bayer Ultra, Beckman, and Dade assays gave good responses across all species. In rats, weak responses were observed with DPC and Ortho, and no measurable response with Tosoh. In dogs, weak responses were observed with Tosoh cTnI, Roche cTnT, and species-specific cTnI. In cynomolgus monkeys, weak responses were observed with species-specific cTnI and Roche cTnT. Assay imprecision was < or = 20% at 3 or more examined cTn concentrations for Beckman (rat, dog, monkey), Dade (rat, dog, monkey), Abbott (rat, dog, monkey), Bayer first generation (dog), Bayer Ultra (rat, dog, monkey), Roche (monkey), DPC (dog, monkey), Ortho (dog, monkey), and Tosoh (dog, monkey) assays, whereas imprecision was < or = 20% at 2 or fewer concentrations for the Bayer first generation (rat, monkey), Roche cTnT (rat, dog), and DPC (rat) assays. CONCLUSIONS Not all cTn assays are suitable for monitoring cTn in each animal species or strain. Individual assay characterization by animal species is needed to prevent misinterpretation of myocardial injury-based cardiac troponin findings.


Clinica Chimica Acta | 2008

Use of the bioMérieux VIDAS® troponin I ultra assay for the diagnosis of myocardial infarction and detection of adverse events in patients presenting with symptoms suggestive of acute coronary syndrome

Fred S. Apple; Stephen W. Smith; Lesly A. Pearce; Ranka Ler; Mary Ann M. Murakami; Marie-Odile Benoit; Camille Levy; Catherine Dumas; Jean-Louis Paul

BACKGROUND We demonstrate the performance of the bioMérieux VIDAS Troponin I Ultra assay for diagnostic accuracy for detection of myocardial infarction (MI) and risk stratification. METHOD cTnI was measured in 545 patients from 2 clinical centers with symptoms suggestive of ACS at admission, with an additional specimen at 4-12 h (453 patients). The 99th percentile value (0.01 microg/l) was used to assess clinical accuracy for diagnosis of acute MI. Primary endpoint for risk stratification was first of cardiac event or death in 302 patients (one center) followed for 60 days. RESULTS 157 (28.8%) patients ruled in for an MI during index hospitalization. Sensitivities and specificities were 88.1% (95% CI 81.9 to 92.4%) and 79.9% (CI 75.5 to 83.6%) for baseline and 100% (CI 96.5 to 100%) and 79.4% (CI 74.4 to 83.4%) for follow-up specimens. ROC curve areas increased from 0.912 (CI 0.879 to 0.944) at baseline to 0.994 (CI 0.988 to 0.999) at second sampling (n=453, p<0.01); with no differences between sites. Primary endpoint rate for the 223 patients (74%) with normal cTnI on presentation was lower than the 79 patients (26%) with cTnI>0.01 ug/l (5.9% vs. 42.3%, p<0.0001). The relative risk for the >0.01 ug/l group was 8.9 (CI 4.6 to 17). CONCLUSION The VIDAS cTnI assay is a sensitive diagnostic method for the early detection of MI and predicts increased risk for adverse events in patients with symptoms suggestive of ACS.


Clinical Chemistry | 2011

Myeloperoxidase Improves Risk Stratification in Patients with Ischemia and Normal Cardiac Troponin I Concentrations

Fred S. Apple; Stephen W. Smith; Lesly A. Pearce; Karen Schulz; Ranka Ler; MaryAnn M. Murakami

BACKGROUND We assessed the ability of myeloperoxidase (MPO) to identify the risk for major adverse cardiac events (MACE) in patients who present with ischemic symptoms suggestive of acute coronary syndrome and have a normal cardiac troponin I (cTnI) value. METHODS We used Siemens (n = 400) and Abbott (n = 350) assays to measure MPO and cTnI in plasma samples from 400 patients. Event rates (myocardial infarction, cardiac death, percutaneous coronary intervention, coronary artery bypass grafting) were estimated by the Kaplan-Meier method and compared with the log-rank statistic. RESULTS At the 30-day follow-up, the adjusted hazard ratios for MACE were 3.9 (P < 0.001) for increased cTnI and 2.7 (P = 0.006) for increased MPO for the Siemens assays and were 5.5 (P < 0.001) for increased cTnI and 2.9 (P = 0.001) for increased MPO for the Abbott assays. Similar findings were observed with 6 months of follow-up. Patients who initially had a normal cTnI value and an increased Siemens MPO value demonstrated a higher rate of MACE at 30 days than those in whom both values were normal (16.1% vs 3.6%, P = 0.002) and 6 months (18.1% vs 5.0%, P = 0.002). Similarly, patients who had an increased Abbott MPO result demonstrated a higher MACE rate at 30 days (12.3% vs 3.9%, P = 0.03) and at 6 months (16.2% vs 5.1%, P = 0.01) than those with normal values. CONCLUSIONS A combination of MPO and cTnI allowed the identification of a greater proportion of patients at risk for MACE than the use of cTnI alone. Increased MPO values remained predictive of future cardiac events even when the cTnI value was normal.


Clinical Chemistry | 2016

Incidence of Undetectable, Measurable, and Increased Cardiac Troponin I Concentrations Above the 99th Percentile Using a High-Sensitivity vs a Contemporary Assay in Patients Presenting to the Emergency Department

Sara A. Love; Yader Sandoval; Stephen W. Smith; Jennifer Nicholson; Jing Cao; Ranka Ler; Karen Schulz; Fred S. Apple

INTRODUCTION We compared the incidence of undetectable [below the limit of detection (LoD)], measurable (LoD to 99th percentile), and increased cardiac troponin I (cTnI) concentrations above the 99th percentile between Abbott high-sensitivity cTnI (hs-cTnI) and contemporary cTnI assays in a US emergency department population. METHODS Patients (n = 2100) presenting to the emergency department who had serial cTnI (0, 3, 6, 9 h) measurements ordered on clinical indication were enrolled. Contemporary cTnI [Abbott Architect used clinically; 99th percentile: 0.030 μg/L (30 ng/L)] and hs-cTnI [Abbott investigational; sex-specific 99th percentiles: female (F) 16 ng/L, male (M) 34 ng/L] assays simultaneously measured fresh EDTA plasma. RESULTS The hs-cTnI assay measured fewer undetectable cTnI concentrations compared to the contemporary cTnI assay across baseline (F: 31% vs 47%, M: 22% vs 40%) and serial (F: 21% vs 46%; M: 19% vs 54%) measurements. Conversely, the proportion of measurable cTnI concentrations was higher using hs-cTnI compared to contemporary cTnI assay across both baseline (F: 46% vs 31%; M: 60% vs 33%) and serial (F: 48% vs 28%; M: 83% vs 40%) measurements. The overall proportion of patients with increased cTnI concentrations above the 99th percentile was not significantly different between the contemporary (31%) and hs-cTnI (26%) assays (P = 0.09). CONCLUSIONS In patients presenting to the emergency department, the use of the Abbott hs-cTnI assay provides clinicians with more numeric cTnI concentrations. This occurs via a shift from results below the LoD to those between the LoD and the 99th percentile and does not increase in the number of cTnI concentrations above the 99th percentile.


Clinical Chemistry | 2016

Prognostic Value of Serial Changes in High-Sensitivity Cardiac Troponin I and T over 3 Months Using Reference Change Values in Hemodialysis Patients

Yader Sandoval; Charles A. Herzog; Sara A. Love; Jing Cao; Yan Hu; Alan H.B. Wu; David T. Gilbertson; Steven M. Brunelli; Amy Young; Ranka Ler; Fred S. Apple

INTRODUCTION Serial changes in cardiac troponin in hemodialysis (HD) patients have uncertain clinical implications. We evaluated associations of adverse outcomes in HD patients with reference change value (RCV) data and tertile concentrations for cardiac troponin I (cTnI) and cTnT measured by high-sensitivity (hs) assays. METHODS RCV data and tertiles for hs-cTnI and hs-cTnT were determined from plasma samples collected 3 months apart in 677 stable outpatient HD patients and assessed for their associations with adverse outcomes using adjusted Cox models. Primary outcomes were all-cause mortality and sudden cardiac death (SCD). RESULTS During a median follow-up of 23 months, 18.6% of patients died. RCVs were: hs-cTnI +37% and -30%; hs-cTnT +25% and -20%. Patients with serial hs-cTnI and hs-cTnT changes >RCV (increase or decrease) had all-cause mortality of 25.2% and 23.8% respectively, compared to 15.0% and 16.5% with changes ≤RCV [adjusted hazard ratios (aHRs): 1.9, P = 0.0003 and 1.7, P = 0.0066), respectively]. Only hs-cTnI changes >RCV were predictive of SCD (aHR 2.6, P = 0.005). hs-Cardiac troponin changes >RCV improved all-cause mortality prognostication compared to changes ≤RCV in tertile 2: hs-cTnI aHR, 2.70 (P = 0.003); hs-cTnT aHR, 1.98 (P = 0.043). The aHR of changes in hs-cTnI in tertile 2 >RCV for SCD was 5.62 (P = 0.039). CONCLUSIONS Changes over 3 months in hs-cTnI and hs-cTnT of >RCV identified patients at greater risk of all-cause mortality, and for hs-cTnI were also predictive of SCD. Among patients with middle tertile cardiac troponin concentrations, hs-cTnI changes >RCV provided additive prognostic value for both SCD and all-cause mortality, whereas those for hs-cTnT provided additive prognostic value only for all-cause mortality.


Clinical Chemistry | 2017

Specificity of B-type natriuretic peptide assays: Cross-reactivity with different BNP, NT-proBNP, and proBNP peptides

Amy K. Saenger; Olaia Rodriguez-Fraga; Ranka Ler; Jordi Ordóñez-Llanos; Allan S. Jaffe; Jens Peter Goetze; Fred S. Apple

BACKGROUND B-type natriuretic peptides (BNPs) are used clinically to diagnose and monitor heart failure and are present in the circulation as multiple proBNP-derived fragments. We investigated the specificity of BNP immunoassays with glycosylated and nonglycosylated BNP, N-terminal proBNP (NT-proBNP), and proBNP peptides to probe the cross-reactivity of each assay. METHODS Nine B-type natriuretic peptides were studied,including synthetic and recombinant BNP (Shionogi, Scios, Mayo), human and synthetic glycosylated and nonglycosylated NT-proBNP (HyTest, Roche Diagnostics), and human glycosylated and nonglycosylated proBNP (HyTest, Scios). Five BNP [Abbott, Abbott POC, Alere, Beckman Coulter, Siemens (Centaur)], 9 NT-proBNP [Ortho-Clinical Diagnostics, Roche, Response, bioMerieux, Siemens (Dimension, Immulite, Stratus CS), Mitsubishi] and 3 research-use-only proBNP immunoassays [Biosite (Alere), Bio-Rad, Goetze] were evaluated. Specificity was assessed by calculating the recovery between baseline and peptide-spiked human plasma pools at target concentrations of 100 ng/L BNP, 300 ng/L proBNP, or 450 ng/L NT-proBNP. All assays were performed in duplicate. RESULTS BNP and NT-proBNP assays demonstrated substantial cross-reactivity with proBNP peptides. NT-proBNP assays do not detect glycosylated forms of either NT-proBNP or proBNP. proBNP assays preferentially detect the BNP 1-32 peptide and have minimal cross-reactivity with BNP peptides and glycosylated proBNP. CONCLUSIONS BNP or NT-proBNP results are not transferable among the current existing immunoassays owing to their differences in cross-reactivity and ability to detect various glycosylated forms of proBNP-derived fragments. Opportunities remain to standardize and harmonize BNP and NT-proBNP assays, as well as to develop specific proBNP assays, to widen their clinical scope of use.


Clinica Chimica Acta | 2008

Performance characteristics of the Architect brain natriuretic peptide (BNP) assay: a two site study.

Shella K. Mongia; Sonia L. La'ulu; Fred S. Apple; Ranka Ler; MaryAnn M. Murakami; William L. Roberts

INTRODUCTION Brain natriuretic peptide (BNP) is produced by the ventricles of the heart and is a biomarker for heart failure. Several commercial assays are now available. We evaluated the performance characteristics of the ARCHITECT BNP assay. METHODS We evaluated the limit of blank, limit of detection, linearity and imprecision. Method comparison studies were performed with 3 other automated BNP assays including the ADVIA Centaur, AxSYM, and UniCel DxI 800 methods. RESULTS The mean LOB and LOD of the Architect assay were 3.5 and 5.8 ng/L, respectively. Imprecision studies yielded within run CVs of 1.1 to 5.1% and total CVs of 2.3 to 5.3% using human plasma based multi-constituent controls at concentrations of 92, 500, and 3500 ng/L. The maximum deviation from the target recovery for dilution linearity was 9.6%. Concordance with other BNP assays at a 100 ng/l cutoff was 91 to 98% and kappa statistics were 0.78 to 0.96. The mean difference between the Architect and Advia Centaur methods was positive. For the other methods, the mean difference with the Architect was negative. CONCLUSIONS The Architect BNP assay shows good performance characteristics with total imprecision < or =5.3%. It agrees well with the Advia Centaur, AxSYM, and UniCel DxI BNP assays.


Clinical Biochemistry | 2017

Sex-specific 99th percentiles derived from the AACC Universal Sample Bank for the Roche Gen 5 cTnT assay: Comorbidities and statistical methods influence derivation of reference limits

Ian L. Gunsolus; Allan S. Jaffe; Anne Sexter; Karen Schulz; Ranka Ler; Brittany Lindgren; Amy K. Saenger; Sara A. Love; Fred S. Apple

OBJECTIVES Our purpose was to determine a) overall and sex-specific 99th percentile upper reference limits (URL) and b) influences of statistical methods and comorbidities on the URLs. METHODS Heparin plasma from 838 normal subjects (423 men, 415 women) were obtained from the AACC (Universal Sample Bank). The cobas e602 measured cTnT (Roche Gen 5 assay); limit of detection (LoD), 3ng/L. Hemoglobin A1c (URL 6.5%), NT-proBNP (URL 125ng/L) and eGFR (60mL/min/1.73m2) were measured, along with identification of statin use, to better define normality. 99th percentile URLs were determined by the non-parametric (NP), Harrell-Davis Estimator (HDE) and Robust (R) methods. RESULTS 355 men and 339 women remained after exclusions. Overall<50% of subjects had measureable concentrations ≥ LoD: 45.6% no exclusion, 43.5% after exclusion; compared to men: 68.1% no exclusion, 65.1% post exclusion; women: 22.7% no exclusion, 20.9% post exclusion. The statistical method used influenced URLs as follows: pre/post exclusion overall, NP 16/16ng/L, HDE 17/17ng/L, R not available; men NP 18/16ng/L, HDE 21/19ng/L, R 16/11ng/L; women NP 13/10ng/L, HDE 14/14ng/L, R not available. CONCLUSIONS We demonstrated that a) the Gen 5 cTnT assay does not meet the IFCC guideline for high-sensitivity assays, b) surrogate biomarkers significantly lowers the URLs and c) statistical methods used impact URLs. Our data suggest lower sex-specific cTnT 99th percentiles than reported in the FDA approved package insert. We emphasize the importance of detailing the criteria used to include and exclude subjects for defining a healthy population and the statistical method used to calculate 99th percentiles and identify outliers.

Collaboration


Dive into the Ranka Ler's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lesly A. Pearce

Hennepin County Medical Center

View shared research outputs
Top Co-Authors

Avatar

Sara A. Love

University of Minnesota

View shared research outputs
Top Co-Authors

Avatar

Stephen W. Smith

Hennepin County Medical Center

View shared research outputs
Top Co-Authors

Avatar

Adrine Y. Chung

Hennepin County Medical Center

View shared research outputs
Top Co-Authors

Avatar

Alan H.B. Wu

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Karen Schulz

Hennepin County Medical Center

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge