Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Rany Busold is active.

Publication


Featured researches published by Rany Busold.


Journal of Trauma-injury Infection and Critical Care | 2013

Self-expanding polyurethane polymer improves survival in a model of noncompressible massive abdominal hemorrhage.

Michael Duggan; Adam Rago; Upma Sharma; Gregory T. Zugates; Toby Freyman; Rany Busold; Caulkins J; Pham Q; Yuchiao Chang; Ali Y. Mejaddam; John Beagle; George C. Velmahos; Marc DeMoya; Lawrence R. Zukerberg; Tat Fong Ng; David R. King

BACKGROUND Intracavitary noncompressible hemorrhage remains a significant cause of preventable death on the battlefield. Two dynamically mixed and percutaneously injected liquids were engineered to create an in situ self-expanding polymer foam to facilitate hemostasis in massive bleeding. We hypothesized that intraperitoneal injection of the polymer could achieve conformal contact with sites of injury and improve survival in swine with lethal hepatoportal injury. METHODS High grade hepatoportal injury was created in a closed abdominal cavity, resulting in massive noncoagulopathic, noncompressible hemorrhage. Animals received either standard battlefield fluid resuscitation (control, n = 12) or fluid resuscitation plus intraperitoneal injection of hemostatic foam (polymer, n = 15) and were monitored for 3 hours. Blood loss was quantified, and all hepatoportal injuries were inspected for consistency. RESULTS Before intervention, all animals initially experienced severe, profound hypotension and near-arrest (mean arterial pressure at 10 minutes, 21 [5.3] mm Hg). Overall survival at 3 hours was 73% in the polymer group and 8% in the control group (p = 0.001). Median survival time was more than 150 minutes in the polymer group versus 23 minutes (19–41.5 minutes) in the control group (p < 0.001), and normalized blood loss in the polymer group was 0.47 (0.30) g/kg per minute versus 3.0 (1.3) g/kg per minute in the controls (p = < 0.001). All hepatoportal injuries were anatomically similar, and the polymer had conformal contact with injured tissues. CONCLUSION Intraperitoneal polymer injection during massive noncompressible hemorrhage reduces blood loss and improves survival in a lethal, closed-cavity, hepatoportal injury model. Chronic safety and additional efficacy studies in other models are needed.


Journal of Trauma-injury Infection and Critical Care | 2014

Self-expanding foam for prehospital treatment of severe intra-abdominal hemorrhage: dose finding study.

Miroslav P. Peev; Adam Rago; John O. Hwabejire; Michael Duggan; John Beagle; John Marini; Greg Zugates; Rany Busold; Toby Freyman; George Velmahos; Marc DeMoya; D. Dante Yeh; Peter J. Fagenholz; Upma Sharma; David R. King

BACKGROUND Noncompressible abdominal bleeding is a significant cause of preventable death on the battlefield and in the civilian trauma environment, with no effective therapies available at point of injury. We previously described the development of a percutaneously administered, self-expanding, poly(urea)urethane foam that improved survival in a lethal Grade V hepatic and portal vein injury model in swine. In this study, we hypothesized that survival with foam treatment is dose dependent. METHODS A high-grade hepatoportal injury was created in a closed abdominal cavity, resulting in massive noncompressible hemorrhage. After injury, the animals were divided into five groups. The control group (n = 12) was treated only with fluid resuscitation, and four polymer groups received different dose volumes (Group 1, n = 6, 64 mL; Group 2, n = 6, 85 mL; Group 3, n = 18, 100 mL; and Group 4, n = 10, 120 mL) in addition to fluids. Ten minutes after injury, the foam was percutaneously administered, and animals were monitored for 3 hours. RESULTS Survival with hepatoportal injury was highest in Group 4 (90%) and decreased in a dose-dependent fashion (Group 3, 72%; Group 2, 33%; Group 1, 17%). All polymer groups survived significantly longer than the controls (8.3%). Hemorrhage rate was reduced in all groups but lowest in Group 4 versus the control group (0.34 [0.052] vs. 3.0 [1.3] mL/kg/min, p < 0.001). Increasing foam dose volume was associated with increased peak intra-abdominal pressure (88.2 [38.9] in Group 4 vs. 9.5 [3.2] in the controls, p < 0.0001) and increased incidence of focal bowel injuries. CONCLUSION The self-expanding foam significantly improves survival in a dose-dependent fashion in an otherwise lethal injury. Higher doses are associated with better survival but resulted in the need for bowel resection.


Journal of Surgical Research | 2013

Development of a lethal, closed-abdomen grade V hepato-portal injury model in non-coagulopathic swine

Michael Duggan; Ali Y. Mejaddam; John Beagle; Marc DeMoya; George C. Velmahosa; Hasan B. Alam; Adam Rago; Greg Zugates; Rany Busold; Toby Freyman; Upma Sharma; David R. King

BACKGROUND Hemorrhage within an intact abdominal cavity remains a leading cause of preventable death on the battlefield. Despite this need, there is no existing closed-cavity animal model to assess new hemostatic agents for the preoperative control of intra-abdominal hemorrhage. METHODS We developed a novel, lethal liver injury model in non-coagulopathic swine by strategic placement of two wire loops in the medial liver lobes including the hepatic and portal veins. Distraction resulted in grade V liver laceration with hepato-portal injury, massive bleeding, and severe hypotension. Crystalloid resuscitation was started once mean arterial pressure (MAP) fell below 65 mm Hg. Monitoring continued for up to 180 min. RESULTS We demonstrated 90% lethality (9/10) in swine receiving injury and fluid resuscitation, with a mean survival time of 43 min. Previous efforts in our laboratory to develop a consistently lethal swine model of abdominal solid organs, including preemptive anticoagulation, a two-hit injury with controlled hemorrhage prior to liver trauma, and the injury described above without resuscitation, consistently failed to result in lethal injury. CONCLUSION This model can be used to screen other interventions for pre hospital control of noncompressible.


Journal of Trauma-injury Infection and Critical Care | 2015

Efficacy of a prehospital self-expanding polyurethane foam for noncompressible hemorrhage under extreme operational conditions.

Adam Rago; Andreas Larentzakis; John Marini; Abby Picard; Michael Duggan; Rany Busold; Marc Helmick; Greg Zugates; John Beagle; Upma Sharma; David R. King

BACKGROUND Noncompressible abdominal hemorrhage is a significant cause of battlefield and civilian mortality. We developed a self-expanding polyurethane foam intended to provide temporary hemorrhage control and enable evacuation to a definitive surgical capability, for casualties who would otherwise die. We hypothesized that foam treatment would be efficacious over a wide range of out-of-hospital operational conditions. METHODS The foam was tested in an established lethal, closed-cavity hepatoportal injury model in four groups as follows. Group 1 involved baseline conditions, wherein foam was deployed from a pneumatically driven, first-generation delivery device at room temperature (n = 6). Group 2 involved foam deployment from a field-relevant, handheld delivery prototype (n = 12). Group 3 involved foam components that were conditioned to simulate 1-year shelf-life (n = 6). Group 4 involved foam that was conditioned to a range of temperatures (10°C and 50°C; n = 6 per group). In all studies, survival was monitored for up to 180 minutes and compared with an ongoing and accumulating control group with no intervention (n = 14). RESULTS In Group 1 with a first-generation delivery system, foam treatment resulted in a significant survival advantage relative to the control group (p < 0.001), confirming previous results. In Group 2 with a handheld delivery system, survival was also improved, 83% at 3 hours, compared with 7% in the control group (p < 0.001). In Group 3, survival was 83% at 3 hours (p = 0.002). In Group 4 at temperature extremes, 3-hour survival was 83% (p = 0.002) and 67% (p = 0.014) in the low- and high-temperature groups, respectively. Temperature extremes did not result in hypothermia, hyperthermia, or thermal injury. In all studies, the bleeding rate in foam groups was significantly lower than in the control group (p < 0.05). CONCLUSION Under a range of military operational conditions, foam treatment resulted in a survival advantage relative to the control group. This supports the feasibility of foam treatment as a prehospital hemostatic bridge to surgery for severely bleeding causalities.


Journal of Trauma-injury Infection and Critical Care | 2014

Self-expanding foam for prehospital treatment of intra-abdominal hemorrhage: 28-day survival and safety.

Adam Rago; Michael Duggan; John Beagle; Miroslav P. Peev; John Marini; John O. Hwabejire; Patricia Hannett; Greg Zugates; Rany Busold; Marc Helmick; George C. Velmahos; Marc DeMoya; D. Dante Yeh; Peter J. Fagenholz; Upma Sharma; David R. King

BACKGROUND Intracavitary noncompressible hemorrhage remains a significant cause of preventable death on the battlefield and in the homeland. We previously demonstrated the hemostatic efficacy of an in situ self-expanding poly(urea)urethane foam in a severe, closed-cavity, hepatoportal exsanguination model in swine. We hypothesized that treatment with, and subsequent explantation of, foam would not adversely impact 28-day survival in swine. METHODS Following a closed-cavity splenic transection, animals received either fluid resuscitation alone (control group, n = 6) or resuscitation plus foam treatment at doses of 100 mL (n = 6), 120 mL (n = 6), and 150 mL (n = 2). Foam was allowed to polymerize in situ and was explanted after 3 hours. The animals were recovered and monitored for 28 days. RESULTS All 18 animals in the 100-mL, 120-mL, and control groups survived to the 28-day endpoint without complications. The 150-mL group was terminated after the acute phase (n = 2). En bloc explantation of the foam took less than 2 minutes and was associated with millimeter-sized remnant particles. All foam animals required some level of enteric repair (imbrication or resection). Excluding the aborted 150-mL group, all animals survived, with no differences in renal or hepatic function, serum chemistries, or semiquantitative abdominal adhesion scores. Histologic analysis demonstrated that remnant particles were associated with a fibrotic capsule and mild inflammation, similar to that of standard suture reaction. In addition, safety testing (including genotoxicity, pyrogenicity, and cytotoxicity) was performed consistent with the ISO-10993 standard, and the materials passed all tests. CONCLUSION For a distinct dose range, 28-day recovery after foam treatment and explantation for noncompressible, intra-abdominal hemorrhage is not associated with significant physiologic or biochemical evidence of end-organ dysfunction. A foam volume exceeding the maximum tolerable dose was identified. Bowel repair is required to ensure survival.


Nature Materials | 2017

The development of bioresorbable composite polymeric implants with high mechanical strength

Upma Sharma; Danny Concagh; Lee Core; Yina Kuang; Changcheng You; Quynh P. Pham; Greg Zugates; Rany Busold; Stephanie Webber; Jonathan Merlo; Robert Langer; George M. Whitesides; Maria Palasis

Implants for the treatment of tissue defects should mimic the mechanical properties of the native tissue of interest and should be resorbable as well as biocompatible. In this work, we developed a scaffold from variants of poly(glycolic) acid which were braided and coated with an elastomer of poly(glycolide-co-caprolactone) and crosslinked. The coating of the scaffold with the elastomer led to higher mechanical strength in terms of compression, expansion and elasticity compared to braids without the elastomer coating. These composite scaffolds were found to have expansion properties similar to metallic stents, utilizing materials which are typically much weaker than metal. We optimized the mechanical properties of the implant by tuning the elastomer branching structure, crosslink density, and molecular weight. The scaffolds were shown to be highly resorbable following implantation in a porcine femoral artery. Biocompatibility was studied in vivo in an ovine model by implanting the scaffolds into femoral arteries. The scaffolds were able to support an expanded open lumen over 12 months in vivo and also fully resorbed by 18 months in the ovine model.


Archive | 2012

In-Situ Forming Foams for Treatment of Aneurysms

Upma Sharma; Gregory T. Zugates; Rany Busold; Toby Freyman


Archive | 2011

In situ forming hemostatic foam implants

Upma Sharma; Irina Gitlin; Gregory T. Zugates; Adam Rago; Parisa Zamiri; Rany Busold; Toby Freyman; Robert J. Caulkins; Quynh P. Pham; Changcheng You; Jeffrey D. Carbeck


Archive | 2009

Polymeric implant delivery system

Nareak Douk; Rany Busold; Lee Core; Kicherl Ho; My Le


Archive | 2012

FOAM AND DELIVERY SYSTEM FOR TREATMENT OF POSTPARTUM HEMORRHAGE

Upma Sharma; Irina Gitlin; Parisa Zamiri; Toby Freyman; Rany Busold; Lee Core; Janet Komatsu; Jennifer Mortensen

Collaboration


Dive into the Rany Busold's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge