Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Rendon C. Nelson is active.

Publication


Featured researches published by Rendon C. Nelson.


Radiology | 2010

Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.

Daniele Marin; Rendon C. Nelson; Sebastian T. Schindera; Samuel Richard; Richard Youngblood; Terry T. Yoshizumi; Ehsan Samei

PURPOSE To investigate whether an adaptive statistical iterative reconstruction (ASIR) algorithm improves the image quality at low-tube-voltage (80-kVp), high-tube-current (675-mA) multidetector abdominal computed tomography (CT) during the late hepatic arterial phase. MATERIALS AND METHODS This prospective, single-center HIPAA-compliant study was institutional review board approved. Informed patient consent was obtained. Ten patients (six men, four women; mean age, 63 years; age range, 51-77 years) known or suspected to have hypervascular liver tumors underwent dual-energy 64-section multidetector CT. High- and low-tube-voltage CT images were acquired sequentially during the late hepatic arterial phase of contrast enhancement. Standard convolution FBP was used to reconstruct 140-kVp (protocol A) and 80-kVp (protocol B) image sets, and ASIR (protocol C) was used to reconstruct 80-kVp image sets. The mean image noise; contrast-to-noise ratio (CNR) relative to muscle for the aorta, liver, and pancreas; and effective dose with each protocol were assessed. A figure of merit (FOM) was computed to normalize the image noise and CNR for each protocol to effective dose. Repeated-measures analysis of variance with Bonferroni adjustment for multiple comparisons was used to compare differences in mean CNR, image noise, and corresponding FOM among the three protocols. The noise power spectra generated from a custom phantom with each protocol were also compared. RESULTS When image noise was normalized to effective dose, protocol C, as compared with protocols A (P = .0002) and B (P = .0001), yielded an approximately twofold reduction in noise. When the CNR was normalized to effective dose, protocol C yielded significantly higher CNRs for the aorta, liver, and pancreas than did protocol A (P = .0001 for all comparisons) and a significantly higher CNR for the liver than did protocol B (P = .003). Mean effective doses were 17.5 mSv +/- 0.6 (standard error) with protocol A and 5.1 mSv +/- 0.3 with protocols B and C. Compared with protocols A and B, protocol C yielded a small but quantifiable noise reduction across the entire spectrum of spatial frequencies. CONCLUSION Compared with standard FBP reconstruction, an ASIR algorithm improves image quality and has the potential to decrease radiation dose at low-tube-voltage, high-tube-current multidetector abdominal CT during the late hepatic arterial phase.


Gastrointestinal Endoscopy | 2003

Lower frequency of peritoneal carcinomatosis in patients with pancreatic cancer diagnosed by EUS-guided FNA vs. percutaneous FNA.

Carlos G. Micames; Paul S. Jowell; Rebekah R. White; Erik K. Paulson; Rendon C. Nelson; Michael A. Morse; Herbert Hurwitz; Theodore N. Pappas; Douglas S. Tyler; Kevin McGrath

BACKGROUND Studies have suggested an increased risk of peritoneal seeding in patients with pancreatic cancer diagnosed by percutaneous FNA. EUS-FNA is an alternate method of diagnosis. The aim of this study was to compare the frequency of peritoneal carcinomatosis as a treatment failure pattern in patients with pancreatic cancer diagnosed by EUS-FNA vs. percutaneous FNA. METHODS Retrospective review of patients with non-metastatic pancreatic cancer identified 46 patients in whom the diagnosis was made by EUS-FNA and 43 with the diagnosis established by percutaneous FNA. All had neoadjuvant chemoradiation. Patients underwent restaging CT after completion of therapy, followed by attempted surgical resection if there was no evidence of disease progression. RESULTS There were no significant differences in tumor characteristics between the two study groups. In the EUS-FNA group, one patient had developed peritoneal carcinomatosis compared with 7 in the percutaneous FNA group (2.2% vs. 16.3%; p<0.025). No patient with a potentially resectable tumor in the EUS-FNA group had developed peritoneal carcinomatosis. CONCLUSIONS Peritoneal carcinomatosis may occur more frequently in patients who undergo percutaneous FNA compared with those who have EUS-FNA for the diagnosis of pancreatic cancer. A concern for peritoneal seeding of pancreatic cancer via percutaneous FNA is warranted. EUS-guided FNA is recommended as the method of choice for diagnosis in patients with potentially resectable pancreatic cancer.


Investigative Radiology | 2006

Contrast-induced nephropathy in patients with chronic kidney disease undergoing computed tomography: a double-blind comparison of iodixanol and iopamidol.

Brendan J. Barrett; Richard W. Katzberg; Henrik S. Thomsen; Nan Chen; Dushyant V. Sahani; Gilles Soulez; Jay P. Heiken; Luigi Lepanto; Zhou Hui Ni; Rendon C. Nelson

Background:Based on a single clinical trial, it has been suggested that the contrast agent iodixanol, which is isotonic to human plasma, may be less nephrotoxic than other nonionic contrast agents in renally impaired patients after intra-arterial injection. We compared the effects on renal function of iopamidol-370 injection (796 mOsm/kg) and iodixanol-320 (290 mOsm/kg) in patients with chronic kidney disease undergoing contrast-enhanced multidetector computed tomography (CE-MDCT) examinations using a multicenter, double-blind, randomized, parallel-group design. Methods:A total of 166 patients with stable moderate-to-severe chronic kidney disease (screening and baseline serum creatinine, SCr, ≥1.5 mg/dL and/or creatinine clearance, CrCl, ≤60 mL/min) who were undergoing CE-MDCT of the liver or peripheral arteries were randomized to receive equi-iodine IV doses (40 gI) of either iopamidol-370 (370 mgI/mL) or iodixanol-320 (320 mgI/mL) at 4 mL/s. SCr and CrCl were obtained at screening, baseline, and at 48–72 ± 6 hours after dose (mean, 57.4 hours). Contrast-induced nephropathy (CIN) was defined as an absolute increase ≥0.5 mg/dL (44.2 &mgr;mol/L) and/or a relative increase in SCr ≥25% from baseline. Results:A total of 153 patients were included in the final analysis (13 patients excluded because of lack of follow-up, hemodialysis to remove contrast, average daily CrCl variation >1% at screening). The 2 study groups were comparable with regard to age, gender distribution, the presence of diabetes, concomitant medications, hydration, and contrast dose. Mean predose SCr was 1.6 ± 0.4 mg/dL in both groups (P = 0.9). An absolute increase ≥0.5 mg/dL (44.2 &mgr;mol/L) in SCr was observed in none of the patients receiving iopamidol-370 and in 2.6% (2/76) of patients receiving iodixanol-320 (95% confidence interval −6.2, 1.0, P = 0.2). A relative increase ≥25% in SCr occurred in 4% (3/77) of patients receiving iopamidol-370 and in 4% (3/76) of the patients receiving iodixanol-320 (95% confidence interval −6.2, 6.1, P = 1.0). Conclusion:The rate of CIN was similarly low in risk patients after intravenous administration of iopamidol-370 or iodixanol-320 for CE-MDCT.


Radiographics | 2010

Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging?

Courtney A. Coursey; Rendon C. Nelson; Daniel T. Boll; Erik K. Paulson; Lisa M. Ho; Amy M. Neville; Daniele Marin; Rajan T. Gupta; Sebastian T. Schindera

Dual-energy CT provides information about how substances behave at different energies, the ability to generate virtual unenhanced datasets, and improved detection of iodine-containing substances on low-energy images. Knowing how a substance behaves at two different energies can provide information about tissue composition beyond that obtainable with single-energy techniques. The term K edge refers to the spike in attenuation that occurs at energy levels just greater than that of the K-shell binding because of the increased photoelectric absorption at these energy levels. K-edge values vary for each element, and they increase as the atomic number increases. The energy dependence of the photoelectric effect and the variability of K edges form the basis of dual-energy techniques, which may be used to detect substances such as iodine, calcium, and uric acid crystals. The closer the energy level used in imaging is to the K edge of a substance such as iodine, the more the substance attenuates. In the abdomen and pelvis, dual-energy CT may be used in the liver to increase conspicuity of hypervascular lesions; in the kidneys, to distinguish hyperattenuating cysts from enhancing renal masses and to characterize renal stone composition; in the adrenal glands, to characterize adrenal nodules; and in the pancreas, to differentiate between normal and abnormal parenchyma.


Physics in Medicine and Biology | 2008

In vivo visualization of abdominal malignancies with acoustic radiation force elastography

Brian J. Fahey; Rendon C. Nelson; David Bradway; Stephen J. Hsu; Douglas M. Dumont; Gregg E. Trahey

The utility of acoustic radiation force impulse (ARFI) imaging for real-time visualization of abdominal malignancies was investigated. Nine patients presenting with suspicious masses in the liver (n = 7) or kidney (n = 2) underwent combined sonography/ARFI imaging. Images were acquired of a total of 12 tumors in the nine patients. In all cases, boundary definition in ARFI images was improved or equivalent to boundary definition in B-mode images. Displacement contrast in ARFI images was superior to echo contrast in B-mode images for each tumor. The mean contrast for suspected hepatocellular carcinomas (HCCs) in B-mode images was 2.9 dB (range: 1.5-4.2) versus 7.5 dB (range: 3.1-11.9) in ARFI images, with all HCCs appearing more compliant than regional cirrhotic liver parenchyma. The mean contrast for metastases in B-mode images was 3.1 dB (range: 1.2-5.2) versus 9.3 dB (range: 5.7-13.9) in ARFI images, with all masses appearing less compliant than regional non-cirrhotic liver parenchyma. ARFI image contrast (10.4 dB) was superior to B-mode contrast (0.9 dB) for a renal mass. To our knowledge, we present the first in vivo images of abdominal malignancies in humans acquired with the ARFI method or any other technique of imaging tissue elasticity.


Gastrointestinal Endoscopy | 2005

Pancreatic FNA in 1000 cases: a comparison of imaging modalities

Keith E. Volmar; Robin T. Vollmer; Paul S. Jowell; Rendon C. Nelson; H. Bill Xie

BACKGROUND Image-guided FNA is a popular method for evaluating pancreatic lesions, but few large studies on pancreatic FNA exist. METHODS Cytologic material, imaging reports, and clinical follow-up information were reviewed from pancreatic FNA cases performed over a 5-year period. RESULTS A total of 1050 pancreatic FNAs were obtained by EUS (n = 843), US (n = 140), and CT (n = 67). On-site assessment was performed in 89.2% (n = 937) of cases. Findings were as follows: positive for neoplasm 48.9% (n = 503), negative 29.1% (n = 306), descriptive 10% (n = 105), suspicious 5.9% (n = 62), atypical/inconclusive 4.6% (n = 48), and nondiagnostic/inadequate 1.5% (n = 26). Follow-up in the form of histology or at least 6 months of clinical observation was available for 61.2% (n = 643). There was an overall false-positive rate of 0.3% and a false-negative rate of 14.3%. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were as follows: 79.4, 99.0, 99.4, 67.9, 84.5 for the total series, respectively; 79.9, 98.8, 99.2, 72.5, 86.5 for EUS, respectively; 77.9, 100, 100, 48.6, 81.7 for US, respectively; and 78.6, 100, 100, 47.1, 82.0 for CT, respectively. In general, accuracy was not influenced by lesion size or site, number of FNA passes, or number of procedures per patient. After controlling for lesion size, EUS resulted in greater accuracy than US or CT when evaluating lesions <3 cm ( p = 0.015). CONCLUSIONS All imaging modalities showed moderate to high sensitivity, specificity, and accuracy. Logistic regression analysis showed that for lesions <3 cm, the EUS method had higher accuracy than US or CT. No statistically significant difference was seen for larger lesions or for the number of FNA passes.


Radiology | 2014

State of the Art: Dual-Energy CT of the Abdomen

Daniele Marin; Daniel T. Boll; Achille Mileto; Rendon C. Nelson

Recent technologic advances in computed tomography (CT)--enabling the nearly simultaneous acquisition of clinical images using two different x-ray energy spectra--have sparked renewed interest in dual-energy CT. By interrogating the unique characteristics of different materials at different x-ray energies, dual-energy CT can be used to provide quantitative information about tissue composition, overcoming the limitations of attenuation-based conventional single-energy CT imaging. In the past few years, intensive research efforts have been devoted to exploiting the unique and powerful opportunities of dual-energy CT for a variety of clinical applications. This has led to CT protocol modifications for radiation dose reduction, improved diagnostic performance for detection and characterization of diseases, as well as image quality optimization. In this review, the authors discuss the basic principles, instrumentation and design, examples of current clinical applications in the abdomen and pelvis, and future opportunities of dual-energy CT.


Journal of Magnetic Resonance Imaging | 2015

Emerging applications for ferumoxytol as a contrast agent in MRI

Mustafa R. Bashir; Lubna Bhatti; Daniele Marin; Rendon C. Nelson

Ferumoxytol is an ultrasmall superparamagnetic iron oxide (USPIO) agent initially approved by the Food and Drug Administration (FDA) as an iron replacement therapy for patients with anemia due to chronic renal failure. Recently, ferumoxytol has been investigated extensively as an intravenous contrast agent in magnetic resonance imaging (MRI). Since it causes regional T1 and T2* shortening in vivo, conventional pulse sequences can be used following ferumoxytol administration to demonstrate signal enhancement or loss. Ferumoxytol can be administered as a rapid bolus and has a long intravascular half‐life on the order of 14–15 hours, making it a potentially useful agent for vascular and perfusion‐weighted MRI. In comparison to other USPIOs, ferumoxytol is less limited by allergic and idiosyncratic reactions. Furthermore, since ferumoxytol is an iron‐based agent with no potential for causing nephrogenic systemic fibrosis, it may be useful as an alternative to gadolinium‐based contrast agents in patients with compromised renal function. Ferumoxytol is ultimately taken up by macrophages/the reticuloendothelial system in the liver, spleen, and lymph nodes, and this uptake mechanism is being explored as a novel imaging technique for vascular lesions, tumors, and lymph nodes. This article reviews the properties of ferumoxytol relevant to MRI as well as many of the uses for the agent currently under investigation. J. Magn. Reson. Imaging 2015;41:884–898.


Radiology | 2010

Making the diagnosis of acute appendicitis: Do more preoperative CT scans mean fewer negative appendectomies? A 10-year study

Courtney A. Coursey; Rendon C. Nelson; Mayur B. Patel; Courtney Cochran; Leslie G. Dodd; David M. DeLong; Craig A. Beam; Steven N. Vaslef

PURPOSE To determine the frequency of preoperative computed tomography (CT) in the evaluation of patients suspected of having appendicitis at one institution during the past 10 years and to determine whether changes in CT utilization were associated with changes in the negative appendectomy rate. MATERIALS AND METHODS Institutional review board approval was obtained, and a waiver of informed consent was granted for this HIPAA-compliant study. A surgical database search yielded medical record numbers of 925 patients (526 [ 56.9%] men and 399 [43.1%] women; mean age, 38 years (range, 18-95 years]) who underwent urgent appendectomy between January 1998 and September 2007. Patients who were younger than 18 years of age at the time of surgery were excluded. CT, pathology, and surgery reports were reviewed. By using logistic regression, changes in the proportion of patients undergoing CT and in the proportion of patients undergoing each year appendectomy in which the appendix was healthy were evaluated. Subgroup analyses based on patient age (<or= 45 years or > 45 years) and sex also were performed. RESULTS Prior to urgent appendectomy, 18.5% of patients underwent preoperative CT in 1998 compared with 93.2% of patients in 2007. The negative appendectomy rate for women 45 years of age and younger decreased from 42.9% in 1998% to 7.1% in 2007. However, the timing of the decline in negative appendectomy rates for women 45 years and younger could not be proved to be associated with the increase in CT use. There was no significant trend toward a lower negative appendectomy rate for men regardless of age or for women older than 45 years of age with increased use of preoperative CT. The shift from single-detector CT to multidetector CT and the use of decreasing section thickness also correlated with a reduction in false-positive diagnoses. CONCLUSION Rising utilization of preoperative CT and advances in technology coincided with a decrease in the negative appendectomy rate for women 45 years and younger but not in men of any age or women older than 45 years.


Biological Cybernetics | 1988

Finding motion parameters from spherical motion fields (or the advantages of having eyes in the back of your head)

Rendon C. Nelson; John Aloimonos

A theory is developed for determining the motion of an observer given the motion field over a full 360 degree image sphere. The method is based on the fact that for an observer translating without rotation, the projected circular motion field about any equator can be divided into disjoint semicircles of clockwise and counterclockwise flow, and on the observation that the effects of rotation decouple around the three equators defining the three principal axes of rotation. Since the effect of rotation is geometrical, the three rotational parameters can be determined independently by searching, in each case, for a rotational value for which the derotated equatorial motion field can be partitioned into 180 degree arcs of clockwise and counterclockwise flow. The direction of translation is also obtained from this analysis. This search is two dimensional in the motion parameters, and can be performed relatively efficiently. Because information is correlated over large distances, the method can be considered a pattern recognition rather than a numerical algorithm. The algorithm is shown to be robust and relatively insensitive to noise and to missing data. Both theoretical and empirical studies of the error sensitivity are presented. The theoretical analysis shows that for white noise of bounded magnitude M, the expected errors is at worst linearly proportional to M. Empirical tests demonstrate negligible error for perturbations of up to 20% in the input, and errors of less than 20% for perturbations of up to 200%.

Collaboration


Dive into the Rendon C. Nelson's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge