Archives of Pathology & Laboratory Medicine | 2000

Effects of Different Hematocrit Levels on Glucose Measurements With Handheld Meters for Point-of-Care Testing

Zuping Tang; Judith H. Lee; Richard F. Louie; Gerald J. Kost

OBJECTIVES To determine the effects of low, normal, and high hematocrit levels on glucose meter measurements and to assess the clinical risks of hematocrit errors. DESIGN Changes in glucose measurements between low and high hematocrit levels were calculated to determine hematocrit effects. The differences between glucose measured with meters and with a plasma glucose method (YSI 2300) also were compared. SETTING Six hand-held glucose meters were assessed in vitro at low (19.1%), normal (38.5%), and high (58.3%) hematocrit levels, and at 6 glucose concentrations ranging from 2.06 mmol/L (37.1 mg/dL) to 30.24 mmol/L (544.7 mg/dL). RESULTS Most systems, regardless of the reference to which they were calibrated, demonstrated positive bias at lower hematocrit levels and negative bias at higher hematocrit levels. Low, normal, and high hematocrit levels progressively lowered Precision G and Precision QID glucose measurements. Hematocrit effects on the other systems were more dependent on the glucose concentration. Overall, Accu-Chek Comfort Curve showed the least sensitivity to hematocrit changes, except at the lowest glucose concentration. CONCLUSIONS We strongly recommend that clinical professionals choose glucose systems carefully and interpret glucose measurements with extreme caution when the patients hematocrit value changes, particularly if there is a simultaneous change in glucose level.


Archives of Pathology & Laboratory Medicine | 2000

Point-of-Care Glucose Testing Effects of Critical Care Variables, Influence of Reference Instruments, and a Modular Glucose Meter Design

Richard F. Louie; Zuping Tang; Demetria V. Sutton; Judith H. Lee; Gerald J. Kost

OBJECTIVE To assess the clinical performance of glucose meter systems when used with critically ill patients. DESIGN Two glucose meter systems (SureStepPro and Precision G) and a modular adaptation (Immediate Response Mobile Analysis-SureStepPro) were assessed clinically using arterial samples from critically ill patients. A biosensor-based analyzer (YSI 2700) and a hospital chemistry analyzer (Synchron CX-7) were the primary and secondary reference instruments, respectively. PATIENTS AND SETTING Two hundred forty-seven critical care patients at the University of California, Davis, Medical Center participated in this study. OUTCOME MEASURES Error tolerances of +/-15 mg/dL for glucose levels </=100 mg/dL and +/-15% for glucose levels >100 mg/dL were used to evaluate glucose meter performance; 95% of glucose meter measurements should fall within these tolerances. RESULTS Compared to the primary reference method, 98% to 100% of SureStepPro and 91% to 95% of Precision G measurements fell within the error tolerances. Paired differences of glucose measurements versus critical care variables (Po(2), pH, Pco(2), and hematocrit) were analyzed to determine the effects of these variables on meter measurements. Po(2) and Pco(2) decreased Precision G and SureStepPro measurements, respectively, but not enough to be clinically significant based on the error tolerance criteria. Hematocrit levels affected glucose measurements on both meter systems. Modular adaptation did not affect test strip performance. CONCLUSIONS Glucose meter measurements correlated best with primary reference instrument measurements. Overall, both glucose meter systems showed acceptable performance for point-of-care testing. However, the effects of some critical care variables, especially low and high hematocrit values, could cause overestimated or underestimated glucose measurements.


American Journal of Clinical Pathology | 2000

Effects of Drugs on Glucose Measurements With Handheld Glucose Meters and a Portable Glucose Analyzer

Zuping Tang; Xiaogu Du; Richard F. Louie; Gerald J. Kost

Thirty drugs used primarily in critical care and hospital settings were tested in vitro to observe interference on glucose measurements with 6 hand-held glucose meters and a portable glucose analyzer. Paired differences of glucose measurements between drug-spiked samples and unspiked control samples were calculated to determine bias. A criterion of +/- 6 mg/dL was used as the cutoff for interference. Ascorbic acid interfered with the measurements on all glucose devices evaluated. Acetaminophen, dopamine, and mannitol interfered with glucose measurements on some devices. Dose-response relationships help assessment of drug interference in clinical use. High dosages of these drugs may be given to critically ill patients or self-administered by patients without medical supervision. Package inserts for the glucose devices may not provide adequate warning information. Hence, we recommend that clinicians choose glucose devices carefully and interpret results cautiously when glucose measurements are performed during or after drug interventions.


Critical Care Medicine | 2001

Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing

Zuping Tang; Richard F. Louie; Judith H. Lee; Debra M. Lee; Earl E. Miller; Gerald J. Kost

ObjectivesTo determine the effects of different oxygen tensions (Po2) on glucose measurements with glucose dehydrogenase (GD)-based and glucose oxidase (GO)-based test strips, to quantitate changes in glucose measurements observed with different Po2 levels, and to discuss the potential risks of oxygen-derived glucose errors in critical care. DesignVenous blood from healthy volunteers was tonometered to create different oxygen tensions simulating patient arterial Po2 levels. Venous blood from diabetic patients was exposed to air to alter oxygen tensions simulating changes in Po2 during sample handling. Whole-blood glucose measurements obtained from these samples with six glucose meters were compared with reference analyzer plasma glucose measurements. Glucose differences were plotted vs. different Po2 levels to identify error trends. Error tolerances were as follows: a) within ±15 mg/dL of the reference measurement for glucose levels ≤100 mg/dL; and b) within ±15% of the reference measurement for glucose levels >100 mg/dL. Setting and Subjects Five healthy volunteers in the bench study and 11 diabetic patients in the clinical study. ResultsIn the bench study, increases in Po2 levels decreased glucose measured with GO-based amperometric test strips, mainly at Po2 levels >100 torr. At nearly constant glucose concentrations, glucose meter systems showed large variations at low (39 torr) vs. high (396 torr) Po2 levels. Glucose measured with GD-based amperometric and GO-based photometric test strips generally were within error tolerances. In the clinical study, 31.6% (Precision PCx), 20.2% (Precision QID), and 23.0% (Glucometer Elite) of glucose measurements with GO-based amperometric test strips, 14.3% (SureStep) of glucose measurements with GO-based photometric test strips, and 4.6% (Accu-Chek Advantage H) and 5.9% (Accu-Chek Comfort Curve) of glucose measurements with GD-based amperometric test strips were out of the error tolerances. ConclusionsDifferent oxygen tensions do not significantly affect glucose measured with the GD-based amperometric test strips, and have minimal effect on GO-based photometric test strips. Increases in oxygen tension lowered glucose measured with GO-based amperometric test strips. We recommend that the effects of different oxygen tensions in blood samples on glucose measurements be minimized by using oxygen-independent test strips for point-of-care glucose testing in critically ill and other patients with high or unpredictable blood Po2 levels.


Critical Care Medicine | 2008

Multiplex polymerase chain reaction detection enhancement of bacteremia and fungemia.

Richard F. Louie; Zuping Tang; Timothy E. Albertson; Stuart H. Cohen; Nam K. Tran; Gerald J. Kost

Objective:To test a multiplex real-time polymerase chain reaction (PCR) method for simultaneous detection of multiple organisms in bloodstream infections. Methods:Prospective observational study at the University of California Davis Medical Center (Sacramento, CA). Two hundred adult (>18 yrs) patients from the emergency room, intensive care units, and general medicine wards at risk of a bloodstream infection and who manifested signs of systemic inflammatory response syndrome (SIRS). Whole blood samples for PCR testing were collected at the same time as blood culture (BC). PCR results were compared to blood and other culture results. Results:PCR detected potentially significant bacteria and fungi in 45 cases compared to 37 by BC. PCR detected the methicillin resistance (mecA) gene in all three culture-confirmed methicillin-resistant Staphylococcus aureus cases. More than 68% of PCR results were confirmed by blood, urine, and catheter culture. Independent clinical arbitrators could not rule out the potential clinical significance of organism(s) detected by PCR, but not by BC. PCR did not detect Enterococcus faecalis in five BC-confirmed cases. On average, seven patient samples could be tested simultaneously with the PCR method in 6.54 ± .27 hrs. Conclusions:Multiplex PCR detected potentially significant bacteria and fungi that were not found by BC. BC found organisms that were not detected by PCR. Despite limitations of both BC and PCR methods, PCR could serve as an adjunct to current culture methods to facilitate early detection of bloodstream infections. Early detection of microorganisms has the potential to facilitate evidence-based treatment decisions, antimicrobial selection, and adequacy of antimicrobial therapy.


Archives of Pathology & Laboratory Medicine | 2000

Effects of pH on glucose measurements with handheld glucose meters and a portable glucose analyzer for point-of-care testing.

Zuping Tang; Xiaogu Du; Richard F. Louie; Gerald J. Kost

OBJECTIVES To determine pH effects on glucose measurements obtained with the latest generation of glucose devices, to quantitate changes in glucose measurements obtained over a wide pH range, and to assess the potential clinical risks of pH effects with use of point-of-care glucose testing. DESIGN Paired differences of glucose measurements between pH-altered and parallel control samples with target pH 7.40 were calculated. SETTING A pH range of 6.94 to 7.84 was used to evaluate pH effects on glucose measurements in vitro with 6 handheld glucose meters and a portable glucose analyzer at both normal, 4.81 mmol/L (86.6 mg/dL), and high, 11.16 mmol/L (201 mg/dL), glucose levels. MAIN OUTCOME MEASURES Glucose measurements obtained from test samples and control samples were compared by calculating paired differences, which were plotted against pH to show pH effects on glucose meter measurements. RESULTS At the normal glucose level, different pH levels did not interfere significantly with glucose measurements. At the high glucose level, a trend whereby low pH decreased and high pH increased glucose measurements was observed on the Precision G and the Precision QID glucose meters. CONCLUSION Because of potential risk in diabetic patients with ketoacidosis and in other patients with acid-base disorders, we recommend that clinicians choose glucose devices carefully and interpret the measurements cautiously when point-of-care glucose testing is performed in critically ill patients with acidemia, alkalemia, or changing acid-base status.


Critical Care Medicine | 2009

Potential clinical utility of polymerase chain reaction in microbiological testing for sepsis

Lutz Eric Lehmann; Julian Alvarez; Klaus Peter Hunfeld; Antonio Goglio; Gerald J. Kost; Richard F. Louie; Annibale Raglio; Benito Regueiro; Heimo Wissing; Frank Stuber

Objectives: To evaluate the potential improvement of antimicrobial treatment by utilizing a new multiplex polymerase chain reaction (PCR) assay that identifies sepsis-relevant microorganisms in blood. Design: Prospective, observational international multicentered trial. Setting: University hospitals in Germany (n = 2), Spain (n = 1), and the United States (n = 1), and one Italian tertiary general hospital. Patients: 436 sepsis patients with 467 episodes of antimicrobial treatment. Methods: Whole blood for PCR and blood culture (BC) analysis was sampled independently for each episode. The potential impact of reporting microorganisms by PCR on adequacy and timeliness of antimicrobial therapy was analyzed. The number of gainable days on early adequate antimicrobial treatment attributable to PCR findings was assessed. Measurements and Main Results: Sepsis criteria, days on antimicrobial therapy, antimicrobial substances administered, and microorganisms identified by PCR and BC susceptibility tests. Results: BC diagnosed 117 clinically relevant microorganisms; PCR identified 154. Ninety-nine episodes were BC positive (BC+); 131 episodes were PCR positive (PCR+). Overall, 127.8 days of clinically inadequate empirical antibiotic treatment in the 99 BC+ episodes were observed. Utilization of PCR-aided diagnostics calculates to a potential reduction of 106.5 clinically inadequate treatment days. The ratio of gainable early adequate treatment days to number of PCR tests done is 22.8 days/100 tests overall (confidence interval 15–31) and 36.4 days/100 tests in the intensive care and surgical ward populations (confidence interval 22–51). Conclusions: Rapid PCR identification of microorganisms may contribute to a reduction of early inadequate antibiotic treatment in sepsis.


Diabetes Technology & Therapeutics | 2000

Oxygen Effects on Glucose Measurements with a Reference Analyzer and Three Handheld Meters

Zuping Tang; Richard F. Louie; Marta Payes; Kai-Chiao J. Chang; Gerald J. Kost

Oxygen may affect glucose meter and reference analyzer measurements. We evaluated the effects of changes in blood oxygen tension (Po2) on Accu-Chek Comfort Curve (Roche Diagnostics, Indianapolis, IN), Precision G, (Abbott Laboratories, Bedford, MA) and One Touch II (Lifescan, Milpitas, CA) glucose meter measurements, and on Yellow Springs Instruments (YSI) (Yellow Springs, OH) reference analyzer measurements. Venous blood drawn from healthy volunteers was adjusted to three glucose levels of 80, 200, and 400 mg/dL, each tonometered with six different Po2 levels (40, 80, 160, 240, 320, and 400 torr). To quantitate oxygen effects on reference analyzer measurements, glucose differences between test sample (Po2 changed) and control (Po2 80 torr) were calculated (YSItest-YSIcontrol). The threshold for determination of oxygen effects was +/-2 SD, where 2 SD was fro


Labmedicine | 2000

Point-of-Care Testing: Millennium Technology for Critical Care

Richard F. Louie; Zuping Tang; David G. Shelby; Gerald J. Kost

Point-of-care testing (POCT) is an important diagnostic tool used in various locations in the hospital, especially in critical care settings such as the intensive care unit (ICU), the operating room (OR), and the emergency department (ED).


Disaster Medicine and Public Health Preparedness | 2009

Thermal stress and point-of-care testing performance: suitability of glucose test strips and blood gas cartridges for disaster response.

Richard F. Louie; Stephanie L. Sumner; Shaunyé Belcher; Ron Mathew; Nam K. Tran; Gerald J. Kost

OBJECTIVE Point-of-care testing (POCT) devices are deployed in the field for emergency on-site testing under a wide range of environmental conditions. Our objective was to evaluate the performance of glucose meter test strips and handheld blood gas analyzer cartridges following thermal stresses that simulate field conditions. METHODS We evaluated electrochemical and spectrophotometric glucose meter systems and a handheld blood gas analyzer. Glucose test strips were cold-stressed (-21 degrees C) and heat-stressed (40 degrees C) for up to 4 weeks. Blood gas cartridges were stressed at -21 degrees C, 2 degrees C, and 40 degrees C for up to 72 hours. Test strip and cartridge performance was evaluated using aqueous quality control solutions. Results were compared with those obtained with unstressed POCT strips and cartridges. RESULTS Heated glucose test strips and blood gas cartridges yielded elevated results. Frozen test strips and cooled cartridges yielded depressed glucose and blood gas results, respectively. Frozen cartridges failed. CONCLUSIONS The performance of glucose test strips and blood gas cartridges was affected adversely by thermal stresses. Heating generated elevated results, and cooling depressed results. Disaster medical assistance teams and emergency medical responders should be aware of these risks. Field POCT devices must be robust to withstand adverse conditions. We recommend that industry produce POCT devices and reagents suitable for disaster medical assistance teams.

Collaboration


Dive into the Richard F. Louie's collaboration.

Top Co-Authors

Avatar

Gerald J. Kost

University of California

View shared research outputs
Top Co-Authors

Avatar

Nam K. Tran

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Zuping Tang

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

John H. Vy

University of California

View shared research outputs
Top Co-Authors

Avatar

Judith H. Lee

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Chloe S. Tang

University of California

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge