Veterinary and Comparative Orthopaedics and Traumatology | 2011
John Field; Margaret A. McGee; Richard M. Stanley; G. Ruthenbeck; T. Papadimitrakis; Andrew C.W. Zannettino; Stan Gronthos; Silviu Itescu
INTRODUCTION Synthetic void-fillers offer an alternative to autograft or allograft bone in the repair of segmental defects. However, the reparative process is delayed as only osteoconductive elements are present. The inclusion of pluripotential cells may resolve this limitation, and the use of allogeneic tissue provides the opportunity for an off-the-shelf remedy. The current study evaluated the utilisation of mesenchymal precursor cells (MPC) for the repair of an ovine critical-size tibial segmental defect. METHODS Twenty-four, mature female sheep underwent surgery for the creation of a 3 cm tibial diaphyseal defect. In one group of 12 sheep the scaffold was used alone, and in the second group the scaffold was seeded with MPC. The defect was stabilised using a locking intramedullary nail and allowed to heal over a nine-month-period. Outcome assessments of healing included radiology of callus formation, computed tomography, assessment of new-bone volume, mechanical attributes, and histological evaluation of linear bone apposition rate and tissue response. RESULTS The MPC-treated group displayed a significantly greater level of callus formation and rate of bone apposition in the defect. DISCUSSION The incorporation of allogeneic MPC to a synthetic void filler stimulated early repair of critical-size diaphyseal segmental defects and holds potential as an off-the-shelf therapy for augmenting bone regeneration.
conference of the industrial electronics society | 2011
Boyin Ding; Richard M. Stanley; B. Cazzolato; John J. Costi
A hexapod robotic test system has been developed to enable complex six degree of freedom (6-DOF) testing of bones, joints, soft tissues, artificial joints and other medical and surgical devices. The device employs six permanent-magnet servomotor driven ballscrews to actuate the system, and measures the displacement response using incremental encoders and loads using a six axis load-cell. The mechanism incorporates a unique design which mitigates many of the issues arising from load-cell compliance, common to most other serial and parallel mechanisms for material testing. This was achieved through a non-collocated design which raises additional challenges. Achieving high bandwidth control of the hexapod also presents challenges, and was achieved using a combination of LabVIEW real-time running on a floating-point Intel processor, along with LabVIEW FPGA running on 16bit Xilinx FPGAs. In this paper the following unique aspects of this hexapod are discussed: the mitigation of load-cell compliance, non-collocated control, implementation of the controller on a real-time platform, and finally technical solutions to solve the complex forward-kinematics solution in real-time. Finally, the results from testing a high-density polymer cylindrical specimen are presented.
Journal of Dynamic Systems Measurement and Control-transactions of The Asme | 2014
Boyin Ding; B. Cazzolato; Richard M. Stanley; Steven Grainger; John J. Costi
Robot frame compliance has a large negative effect on the global accuracy of the system when large external forces/torques are exerted. This phenomenon is particularly problematic in applications where the robot is required to achieve ultrahigh (micron level) accuracy under very large external loads, e.g., in biomechanical testing and high precision machining. To ensure the positioning accuracy of the robot in these applications, the authors proposed a novel Stewart platform-based manipulator with decoupled sensor–actuator locations. The unique mechanism has the sensor locations fully decoupled from the actuator locations for the purpose of passively compensating for the load frame compliance, as a result improving the effective stiffness of the manipulator in six degrees of freedom (6DOF). In this paper, the stiffness of the proposed manipulator is quantified via a simplified method, which combines both an analytical model (robot kinematics error model) and a numerical model [finite element analysis (FEA) model] in the analysis. This method can be used to design systems with specific stiffness requirements. In the control aspect, the noncollocated positions of the sensors and actuators lead to a suboptimal control structure, which is addressed in the paper using a simple Jacobian-based decoupling method under both kinematics- and dynamics-based control. Simulation results demonstrate that the proposed manipulator configuration has an effective stiffness that is increased by a factor of greater than 15 compared to a general design. Experimental results show that the Jacobian-based decoupling method effectively increases the dynamic tracking performance of the manipulator by 25% on average over a conventional method.
Arthroscopy | 2010
Stuart Roy; Mark Fernhout; Richard M. Stanley; Margaret A. McGee; Tania Carbone; John Field; Peter J Dobson
PURPOSE Because tibial fixation of soft-tissue grafts in anterior cruciate ligament (ACL) reconstruction is problematic, this study aimed to develop a means of delivering bone graft evenly around tendon autograft and define any mechanical, radiologic, or histologic benefit using an ovine model. METHODS A device to deliver bone graft evenly throughout the tibial tunnel was developed. Forty mature sheep underwent simulated quadruple hamstring tendon-ACL reconstruction by use of a bioresorbable interference screw, either with or without bone graft augmentation of the tibial tunnel. Endpoint data were derived at time 0 and after 6 weeks in vivo. Radiostereometric analysis provided quantitation of the translational characteristics; computed tomography evaluated tunnel volume, and measures of yield strength and stiffness were obtained. Sequential fluorochrome administration assessed bone formation, and light microscopy surveyed the biological response. RESULTS Radiostereometric analysis highlighted differences in the translational characteristics of ACL-deficient knees when compared with intact knees. Reconstructed knees (with or without autograft) showed significantly greater translation when compared with unoperated knees at 6 weeks; autograft bone augmentation provided no benefit. Neither tunnel volume nor yield strength nor stiffness was improved with the addition of autograft bone. No untoward histologic responses were observed. Bone apposition rates were similar between treatment groups. An even distribution of bone graft throughout the tunnels was observed. CONCLUSIONS This model has confirmed the ability of the bone graft-delivery system to evenly distribute bone graft throughout the tunnels. However, the study has failed to show improvement in stability or fixation strength after augmentation with autograft bone. CLINICAL RELEVANCE The autograft bone-delivery system may provide a means of establishing an osteoconductive/inductive environment. At this early juncture (6 weeks), no benefit could be defined. Its use in combination with bone morphogenetic proteins or stem cells may provide more rapid fixation, rehabilitation, and reconstitution of bone volume within the tunnel.
Journal of Orthopaedic Research | 2016
Dhara B. Amin; Dana Sommerfeld; I.M. Lawless; Richard M. Stanley; Boyin Ding; John J. Costi
While the effects of disc degeneration on compression and rotation motions have been studied, there is no data for shear loading. Clinical research has shown that those with low back pain (a potential consequence of degeneration) experience a 75% greater lateral shear force than those without it. Therefore, the aim was to compare the effect of degeneration on spine segment stiffness and phase angle in each of six degree of freedom (6DOF) loading directions. Fourteen intact functional spinal units (FSU) were dissected from human lumbar spines (mean (SD) age 76.2 (11) years, Thompson grades 3 (N = 5, mild), 4 (N = 6, moderate), 5 (N = 3, severe)). Each FSU was tested in ±6DOFs while subjected to a physiological preload, hydration, and temperature (37°C) conditions in a hexapod robot. A one‐way ANOVA between degenerated groups was performed on stiffness and phase angle for each DOF. Significant differences in stiffness were found between mild and moderate degenerative groups in lateral shear (p = 0.001), and axial rotation (p = 0.001), where moderate degeneration had decreased stiffness. For phase angle, significant differences were seen in anterior shear (p = 0.017), and axial rotation (p = 0.026), where phase angle for mild degeneration was less than moderate. Trends of stiffness and phase angle changes between degenerative groups were similar within each DOF. Clinically, the identification of the DOFs that are most affected by degeneration could be used in rehabilitation to improve supplemental stabilization of core muscle groups.
Journal of Biomechanics | 2014
Francois Fraysse; John J. Costi; Richard M. Stanley; Boyin Ding; Duncan Thomas McGuire; Kevin Eng; Gregory I. Bain; Dominic Thewlis
Understanding the kinematics of the carpus is essential to the understanding and treatment of wrist pathologies. However, many of the previous techniques presented are limited by non-functional motion or the interpolation of points from static images at different postures. We present a method that has the capability of replicating the kinematics of the wrist during activities of daily living using a unique mechanical testing system. To quantify the kinematics of the carpal bones, we used bone pin-mounted markers and optical motion capture methods. In this paper, we present a hammering motion as an example of an activity of daily living. However, the method can be applied to a wide variety of movements. Our method showed good accuracy (1.0-2.6°) of in vivo movement reproduction in our ex vivo model. Most carpal motion during wrist flexion-extension occurs at the radiocarpal level while in ulnar deviation the motion is more equally shared between radiocarpal and midcarpal joints, and in radial deviation the motion happens mainly at the midcarpal joint. For all rotations, there was more rotation of the midcarpal row relative to the lunate than relative to the scaphoid or triquetrum. For the functional motion studied (hammering), there was more midcarpal motion in wrist extension compared to pure wrist extension while radioulnar deviation patterns were similar to those observed in pure wrist radioulnar deviation. Finally, it was found that for the amplitudes studied the amount of carpal rotations was proportional to global wrist rotations.
Journal of Biomechanical Engineering-transactions of The Asme | 2015
Dhara B. Amin; I.M. Lawless; Dana Sommerfeld; Richard M. Stanley; Boyin Ding; John J. Costi
Polymethyl methacrylate (PMMA) and Woods Metal are fixation media for biomechanical testing; however, the effect of each potting medium on the measured six degree-of-freedom (DOF) mechanical properties of human lumbar intervertebral discs is unknown. The first aim of this study was to compare the measured 6DOF elastic and viscoelastic properties of the disc when embedded in PMMA compared to repotting in Woods Metal. The second aim was to compare the surface temperature of the disc when potted with PMMA and Woods Metal. Six human lumbar functional spinal units (FSUs) were first potted in PMMA, and subjected to overnight preload in a saline bath at 37 °C followed by five haversine loading cycles at 0.1 Hz in each of 6DOF loading directions (compression, left/right lateral bending, flexion, extension, left/right axial rotation, anterior/posterior, and lateral shear). Each specimen was then repotted in Woods Metal and subjected to a 2-h re-equilibrating preload followed by repeating the same 6DOF tests. Outcome measures of stiffness and phase angle were calculated from the final loading cycle in each DOF and were expressed as normalized percentages relative to PMMA (100%). Disc surface temperatures (anterior, left/right lateral) were measured during potting. Paired t-tests (with alpha adjusted for multiple DOF) were conducted to compare the differences in each outcome parameter between PMMA and Woods Metal. No significant differences in stiffness or phase angle were found between PMMA and Woods Metal. On average, the largest trending differences were found in the shear DOFs for both stiffness (approximately 35% greater for Woods Metal compared to PMMA) and phase angle (approximately 15% greater for Woods Metal). A significant difference in disc temperature was found at the anterior surface after potting with Woods Metal compared to PMMA, which did not exceed 26 °C. Woods Metal is linear elastic, stiffer than PMMA and may reduce measurement artifact of potting medium, particularly in the shear directions. Furthermore, it is easier to remove than PMMA, reuseable, and cost effective.
Veterinary and Comparative Orthopaedics and Traumatology | 2009
John Field; Richard M. Stanley; Richard Appleyard; Margaret A. McGee; Stuart A. Callary; Kjell G. Nilsson
OBJECTIVES The quantitation of the impact of hemiarthroplasty currently involves clinical outcome measures and radiographic evaluation. This study used in vivo and in vitro means in order to evaluate articular cartilage changes following hemiarthroplasty in the sheep. METHODS Radiostereometric analysis (RSA) was utilized in order to quantitate migration (penetration) in vivo of the femoral head into the articular cartilage of the acetabulum. Dynamic stiffness of retrieved specimens was quantitated in vitro using a handheld device. Chondrocyte viability was assessed using live/dead cell staining and quantitated using image analysis techniques. Saffranin-O staining provided histological assessment of the cellular response to hemiarthroplasty. RESULTS RSA showed rapid penetration of the femoral head into the acetabular cartilage over six months. Significantly higher levels of dynamic stiffness were observed in the acetabula following hemiarthroplasty. Confocal imagery highlighted changes in chondrocyte distribution and morphology. A loss of metachromasia, fibrovascular tissue invasion and apoptosis were observed histologically. CONCLUSIONS RSA and measurement of the dynamic mechanical characteristics of cartilage provide a means of evaluating the development of degenerative articular cartilage changes in response to hemiarthroplasty.
Journal of Biomechanics | 2016
Dhara B. Amin; I.M. Lawless; Dana Sommerfeld; Richard M. Stanley; Boyin Ding; John J. Costi
The complex, direction-dependent, poro-viscoelastic properties of the intervertebral disc (disc) suggest that investigations of the six degree of freedom (6DOF) behaviour may be susceptible to inter-test variation in mechanical response if the disc does not return to initial conditions between loading directions. No studies have quantified the effects of sequential multi-directional loading on the consistency of the compressive response of the disc throughout a 6DOF testing protocol. Therefore, the objective of this study was to determine the effect of 6DOF loading on the compressive properties (stiffness and phase angle) of human discs, as evaluated by a reference compression test performed after each single DOF test. Fourteen intact human functional spinal units (FSU) were tested in each of ±6DOFs (shear directions followed by bending and compression) across four orders of magnitude loading frequencies (0.001-1Hz), followed by reference compression tests while subjected to physiological preload, hydration, and body temperature conditions in a hexapod robot. Repeated measures ANOVA revealed significant within-subjects effects between the reference compression tests for modulus (p<0.001), stiffness (p<0.001), and phase angle (p=0.008). Significant post-hoc pairwise comparisons were initially seen between the control and other reference compression tests for stiffness and modulus after the shear DOFs, however, no significant differences were present after the final reference compression test compared to control. More pronounced effects were seen for stiffness in comparison to modulus and phase angle. These effects may be due to three potentials factors, which include the sequence of testing, the cohort of degenerative specimens, and/or cumulative creep due to the constant application of a follower load. While the sequence of test directions was chosen to minimise the biphasic effect, there may be other sequences, which could result in minimal changes in compressive properties.
Medical Engineering & Physics | 2014
John J. Costi; Richard M. Stanley; Boyin Ding; Lucian B. Solomon
INTRODUCTION This study compared the initial viscoelastic properties of a segmental tibial defect stabilized with intramedullary nailing and impaction bone grafting to that of a transverse fracture stabilized with intramedullary nailing. MATERIALS AND METHODS Seven sheep tibiae were tested in compression (1000N), bending and torsion (6Nm) in a six degree-of-freedom hexapod robot. Tests were repeated across three groups: intact tibia (Intact), transverse fracture stabilized by intramedullary nailing (Fracture), and segmental defect stabilized with a nail and impaction bone grafting (Defect). Repeated measures ANOVA on the effect of group on stiffness/phase angle were conducted for each loading direction. RESULTS The Intact group was significantly stiffer than the Fracture and Defect groups in bending and torsion (p<0.022 for both loading directions), and was marginal for the Defect group in compression (p=0.052). No significant differences were found between the Fracture and Defect groups (p>0.246 for all loading directions) for stiffness/phase angle. In compression and bending, phase angles were significantly greater for the Fracture and Defect groups compared to Intact (p<0.025), with no significant differences between groups in torsion (p=0.13). Sensitivity analyses conducted between the Fracture and Defect group differences found that they were not of clinical significance. CONCLUSION The initial properties of a segmental defect stabilized with intramedullary nailing and impaction bone grafting was not clinically significantly different to that of a transverse fracture stabilized with intramedullary nailing.