Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Robert A. Schweikert is active.

Publication


Featured researches published by Robert A. Schweikert.


Circulation | 2003

Phased-array intracardiac echocardiography monitoring during pulmonary vein isolation in patients with atrial fibrillation: impact on outcome and complications.

Nassir F. Marrouche; David O. Martin; Oussama Wazni; A. Marc Gillinov; Allan L. Klein; Mandeep Bhargava; Eduardo B. Saad; Dianna Bash; Hirotsugu Yamada; Wael A. Jaber; Robert A. Schweikert; Patrick Tchou; Ahmad Abdul-Karim; Walid Saliba; Andrea Natale

Background—The objective of this study was to assess the impact of intracardiac echocardiography (ICE) on the long-term success and complications in patients undergoing pulmonary vein isolation (PVI) for treatment of atrial fibrillation (AF). Methods and Results—Three hundred fifteen patients underwent PVI for treatment of AF. Each patient underwent ostial isolation of all PVs using a cooled-tip ablation catheter. PVI was performed using circular mapping (CM) alone (group 1, 56 patients), CM and ICE (group 2, 107 patients), and CM and ICE with titration of radiofrequency energy based on visualization of microbubbles by ICE (group 3, 152 patients). After a mean follow-up time of 417±145 days, 19.6% (11 of 56), 16.8% (18 of 107), and 9.8% (15 of 152) of patients in groups 1, 2, and 3 experienced recurrence of AF, respectively. Moreover, whereas no group 3 patient experienced severe (>70%) PV stenosis, severe PV stenosis was documented in 3 (3.5%) of 56 patients in group 1 and in 2 (1.8%) of 107 patients in group 2 (P <0.05). No embolic events were detected in group 3 patients. Conclusions—Intracardiac echocardiography improves the outcome of cooled-tip PVI. Power adjustment guided by direct visualization of microbubble formation reduces the risk of PV stenosis and improves long-term cure.


The New England Journal of Medicine | 2008

Pulmonary-Vein Isolation for Atrial Fibrillation in Patients with Heart Failure

Mohammed N. Khan; Pierre Jaïs; Jennifer E. Cummings; Luigi Di Biase; Prashanthan Sanders; David O. Martin; Josef Kautzner; Steven Hao; Sakis Themistoclakis; Raffaele Fanelli; Domenico Potenza; Raimondo Massaro; Oussama Wazni; Robert A. Schweikert; Walid Saliba; Paul J. Wang; Amin Al-Ahmad; Salwa Beheiry; Pietro Santarelli; Randall C. Starling; Antonio Dello Russo; Gemma Pelargonio; Johannes Brachmann; Volker Schibgilla; Aldo Bonso; Michela Casella; Antonio Raviele; Michel Haïssaguerre; Andrea Natale

BACKGROUND Pulmonary-vein isolation is increasingly being used to treat atrial fibrillation in patients with heart failure. METHODS In this prospective, multicenter clinical trial, we randomly assigned patients with symptomatic, drug-resistant atrial fibrillation, an ejection fraction of 40% or less, and New York Heart Association class II or III heart failure to undergo either pulmonary-vein isolation or atrioventricular-node ablation with biventricular pacing. All patients completed the Minnesota Living with Heart Failure questionnaire (scores range from 0 to 105, with a higher score indicating a worse quality of life) and underwent echocardiography and a 6-minute walk test (the composite primary end point). Over a 6-month period, patients were monitored for both symptomatic and asymptomatic episodes of atrial fibrillation. RESULTS In all, 41 patients underwent pulmonary-vein isolation, and 40 underwent atrioventricular-node ablation with biventricular pacing; none were lost to follow-up at 6 months. The composite primary end point favored the group that underwent pulmonary-vein isolation, with an improved questionnaire score at 6 months (60, vs. 82 in the group that underwent atrioventricular-node ablation with biventricular pacing; P<0.001), a longer 6-minute-walk distance (340 m vs. 297 m, P<0.001), and a higher ejection fraction (35% vs. 28%, P<0.001). In the group that underwent pulmonary-vein isolation, 88% of patients receiving antiarrhythmic drugs and 71% of those not receiving such drugs were free of atrial fibrillation at 6 months. In the group that underwent pulmonary-vein isolation, pulmonary-vein stenosis developed in two patients, pericardial effusion in one, and pulmonary edema in another; in the group that underwent atrioventricular-node ablation with biventricular pacing, lead dislodgment was found in one patient and pneumothorax in another. CONCLUSIONS Pulmonary-vein isolation was superior to atrioventricular-node ablation with biventricular pacing in patients with heart failure who had drug-refractory atrial fibrillation. (ClinicalTrials.gov number, NCT00599976.)


Journal of the American College of Cardiology | 2002

Circular Mapping and Ablation of the Pulmonary Vein for Treatment of Atrial Fibrillation Impact of Different Catheter Technologies

Nassir F. Marrouche; Thomas Dresing; Christopher R. Cole; Dianna Bash; Eduardo B. Saad; Stephen Pavia; Robert A. Schweikert; Walid Saliba; Ahmed Abdul-Karim; Ennio Pisano; Raffaele Fanelli; Patrick Tchou; Andrea Natale

OBJECTIVES We conducted this study to compare the efficacy and safety of different catheter ablation technologies and of distal versus ostial pulmonary veins (PV) isolation using the circular mapping technique. BACKGROUND Electrical isolation of the PVs in patients with atrial fibrillation (AF) remains a technical challenge. METHODS Two hundred eleven patients (163 men; mean age 53 +/- 11 years) with symptomatic AF were included in this study. In the first 21 patients (group 1), distal isolation (> or = 5 mm from the ostium) was achieved targeting veins triggering AF. In the remaining 190 patients (group 2), ostial isolation of all PVs was performed using 4-mm tip (47 patients), 8-mm tip (21 patients), or cooled-tip (122 patients) ablation catheters. RESULTS Distal isolation was able to eliminate premature atrial contractions (PACs) and AF in six of 21 patients (29%) and 10 of 34 PVs. After a mean follow-up time of 6 +/- 4 months, no patients treated with the 8-mm tip catheter experienced recurrence of AF, whereas 21% (10 of 47 patients) and 15% (18 of 122 patients) of the patients ablated with the 4-mm tip and the cooled-tip ablation catheters experienced recurrence of AF after a mean follow-up of 10 +/- 3 and 4 +/- 2 months, respectively. Significant complications including stroke, tamponade, and severe stenosis occurred in 3.5% (8/211) of patients. CONCLUSIONS Catheter technologies designed to achieve better lesion size appeared to have a positive impact on procedure time, fluoroscopy time, number of lesions, and overall efficacy. Although distal isolation can be achieved with fewer lesions, ostial isolation is required in the majority of patients to eliminate arrhythmogenic PACs and AF.


Circulation | 2010

Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-Up The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) Trial

Niraj Varma; Andrew E. Epstein; Anand Irimpen; Robert A. Schweikert; Charles Love

Background— Monitoring implantable cardiac device function and patient condition is important. The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial tested the hypothesis that remote home monitoring with automatic daily surveillance (HM) is safe and effective for implantable cardioverter-defibrillator follow-up for 1 year and enables rapid physician evaluation of significant events. Methods and Results— In total, 1339 patients were randomized 2:1 to HM or conventional follow-up. Follow-up checks occurred at 3, 6, 9, 12, and 15 months after implantation. HM was used before office visits at 3 and 15 months in the HM group. At 6, 9, and 12 months, HM only was used but was followed by office visits if necessary. Conventional patients were evaluated with office visits only. Scheduled office visits and unscheduled evaluations, incidence of morbidity, and time elapsed from first event occurrence in each patient to physician evaluation were tracked for each group. HM and conventional patients were similar (age, 63.3±12.8 versus 64.0±12.1 years; gender, 72.0% versus 73.1% male; New York Heart Association class II, 55.9% versus 60.4%; pathology: left ventricular ejection fraction, 29.0±10.7% versus 28.5±9.8%; coronary artery disease, 64.8% versus 71.7%; primary prevention indication, 72.2% versus 73.8%; and dual-chamber implants, 57.8% versus 56.6%). HM reduced total in-hospital device evaluations by 45% without affecting morbidity. In the HM group, 85.8% of all 6-, 9-, and 12-month follow-ups were performed remotely only, indicating that HM provided sufficient assessment in the majority. Median time to evaluation was <2 days in the HM group compared with 36 days in the conventional group (P<0.001) for all arrhythmic events. Conclusions— HM is safe and allows more rapid detection of actionable events compared with conventional monitoring in patients with implantable electronic cardiac devices. Clinical Trials Registration— URL: http:/www.clinicaltrials.gov. Unique identifier: NCT00336284.


Circulation | 2003

Pulmonary Vein Stenosis After Radiofrequency Ablation of Atrial Fibrillation Functional Characterization, Evolution, and Influence of the Ablation Strategy

Eduardo B. Saad; Antonio Rossillo; Cynthia P. Saad; David O. Martin; Mandeep Bhargava; Demet Erciyes; Dianna Bash; Michelle Williams-Andrews; Salwa Beheiry; Nassir F. Marrouche; James Adams; Ennio Pisano; Raffaele Fanelli; Domenico Potenza; Antonio Raviele; Aldo Bonso; Sakis Themistoclakis; Joannes Brachmann; Walid Saliba; Robert A. Schweikert; Andrea Natale

Background—Pulmonary vein (PV) stenosis is a complication of ablation for atrial fibrillation. The impact of different ablation strategies on the incidence of PV stenosis and its functional characterization has not been described. Methods and Results—PV isolation was performed in 608 patients. An electroanatomic approach was used in 71 and circular mapping in 537 (distal isolation, 25; ostial isolation based on PV angiography, 102; guided by intracardiac echocardiography, 140; with energy delivery based on visualization of microbubbles, 270). Severe (≥70%) narrowing was detected in 21 patients (3.4%), and moderate (50% to 69%) and mild (<50%) narrowing occurred in 27 (4.4%) and 47 (7.7%), respectively. Severe stenosis occurred in 15.5%, 20%, 2.9%, 1.4%, and 0%, respectively. Development of symptoms was correlated with involvement of >1 PV with severe narrowing (P =0.01), whereas all patients with mild and moderate narrowing were asymptomatic. In the latter group, lung perfusion (V/Q) scans were normal in all but 4 patients. All patients with severe stenosis had abnormal perfusion scans. Conclusions—V/Q scans are useful to assess the functional significance of PV stenosis. Mild and moderate degrees of PV narrowing are not associated with development of symptoms and seem to have no or minimal detrimental effect on pulmonary flow. The incidence of severe PV stenosis seems to be declining with better imaging techniques to ensure ostial isolation and to guide power titration. Mild narrowing 3 months after ablation does not preclude future development of severe stenosis and should be assessed with repeat imaging studies.


Circulation | 2005

Response of Atrial Fibrillation to Pulmonary Vein Antrum Isolation Is Directly Related to Resumption and Delay of Pulmonary Vein Conduction

Atul Verma; Fethi Kilicaslan; Ennio Pisano; Nassir F. Marrouche; Raffaele Fanelli; Johannes Brachmann; Jens Geunther; Domenico Potenza; David O. Martin; Jennifer E. Cummings; J. David Burkhardt; Walid Saliba; Robert A. Schweikert; Andrea Natale

Background—The role of pulmonary vein (PV) isolation in ablative treatment of atrial fibrillation (AF) has been debated in conflicting reports. We sought to compare PV conduction in patients who had no AF recurrence (group I), patients who could maintain sinus rhythm on antiarrhythmic medication (group II), and patients who had recurrent AF despite antiarrhythmic medication (group III) after PV antrum isolation (PVAI). Methods and Results—PV conduction was examined in consecutive patients undergoing second PVAI for AF recurrence. We also recruited some patients cured of AF to undergo a repeat, limited electrophysiological study at >3 months after PVAI. All patients underwent PVAI with an intracardiac echocardiography (ICE)–guided approach with complete isolation of all 4 PV antra (PVA). The number of PVs with recurrent conduction and the shortest atrial to PV (A-PV) conduction delay was measured with the use of consistent Lasso positions defined by ICE. Late AF recurrence was defined as AF >2 months after PVAI with the patient off medications. Patients in groups I (n=26), II (n=37), and III (n=44) did not differ at baseline (38% permanent AF; ejection fraction 53±6%). Recurrence of PV–left atrial (LA) conduction was seen in 1.7±0.8 and 2.2±0.8 PVAs for groups II and III but only in 0.2±0.4 for group I (P=0.02). In patients with recurrent PV-LA conduction, the A-PV delay increased from the first to second procedure by 69±47% for group III, 267±110% for group II, and 473±71% for group I (P<0.001). When pacing was at a faster rate, A-PV block developed in all 5 of the group I patients with recurrent PV-LA conduction. Conclusions—The majority of patients with drug-free cure show no PV-LA conduction recurrence. Substantial A-PV delay is seen in patients able to maintain sinus rhythm on antiarrhythmic medication or cured of AF compared with patients who fail PVAI.


Circulation | 2010

Left Atrial Appendage An Underrecognized Trigger Site of Atrial Fibrillation

Luigi Di Biase; J. David Burkhardt; Prasant Mohanty; Javier Sanchez; Sanghamitra Mohanty; Rodney Horton; G. Joseph Gallinghouse; Shane Bailey; Jason Zagrodzky; Pasquale Santangeli; Steven Hao; Richard Hongo; Salwa Beheiry; Sakis Themistoclakis; Aldo Bonso; Antonio Rossillo; Andrea Corrado; Antonio Raviele; Amin Al-Ahmad; Paul J. Wang; Jennifer E. Cummings; Robert A. Schweikert; Gemma Pelargonio; Antonio Dello Russo; Michela Casella; Pietro Santarelli; William R. Lewis; Andrea Natale

Background— Together with pulmonary veins, many extrapulmonary vein areas may be the source of initiation and maintenance of atrial fibrillation. The left atrial appendage (LAA) is an underestimated site of initiation of atrial fibrillation. Here, we report the prevalence of triggers from the LAA and the best strategy for successful ablation. Methods and Results— Nine hundred eighty-seven consecutive patients (29% paroxysmal, 71% nonparoxysmal) undergoing redo catheter ablation for atrial fibrillation were enrolled. Two hundred sixty-six patients (27%) showed firing from the LAA and became the study population. In 86 of 987 patients (8.7%; 5 paroxysmal, 81 nonparoxysmal), the LAA was found to be the only source of arrhythmia with no pulmonary veins or other extrapulmonary vein site reconnection. Ablation was performed either with focal lesion (n=56; group 2) or to achieve LAA isolation by placement of the circular catheter at the ostium of the LAA guided by intracardiac echocardiography (167 patients; group 3). In the remaining patients, LAA firing was not ablated (n=43; group 1). At the 12±3-month follow-up, 32 patients (74%) in group 1 had recurrence compared with 38 (68%) in group 2 and 25 (15%) in group 3 (P<0.001). Conclusions— The LAA appears to be responsible for arrhythmias in 27% of patients presenting for repeat procedures. Isolation of the LAA could achieve freedom from atrial fibrillation in patients presenting for a repeat procedure when arrhythmias initiating from this structure are demonstrated.


Heart Rhythm | 2008

Ablation for longstanding permanent atrial fibrillation: Results from a randomized study comparing three different strategies

Claude S. Elayi; Atul Verma; Luigi Di Biase; Chi Keong Ching; Dimpi Patel; Conor D. Barrett; David O. Martin; Bai Rong; Tamer S. Fahmy; Yaariv Khaykin; Richard Hongo; Steven Hao; Gemma Pelargonio; Antonio Dello Russo; Michela Casella; Pietro Santarelli; Domenico Potenza; Raffaele Fanelli; Raimondo Massaro; Mauricio Arruda; Robert A. Schweikert; Andrea Natale

BACKGROUND This prospective multicenter randomized study aimed to compare the efficacy of 3 common ablation methods used for longstanding permanent atrial fibrillation (AF). METHODS A total of 144 patients with longstanding permanent AF (median duration 28 months) were randomly assigned to circumferential pulmonary vein ablation (CPVA, group 1, n = 47), to pulmonary vein antrum isolation (PVAI, group 2, n = 48) or to a hybrid strategy combining ablation of complex fractionated or rapid atrial electrograms (CFAE) in both atria followed by a pulmonary vein antrum isolation (CFAE + PVAI, group 3, n = 49). RESULTS Scarring in the left atrium and structural heart disease/hypertension were present in most patients (65%). After a mean follow-up of 16 months, 11% of patients in group 1, 40% of patients in group 2 and 61% of patients in group 3 were in sinus rhythm after one procedure and with no antiarrhythmic drugs (P < .001). Sinus rhythm maintenance would increase respectively to 28% (group 1), 83% (group 2), and 94% (group 3) after 2 procedures and with antiarrhythmic drugs (AADs, P < .001). The AF terminated during ablation, either by conversion to sinus rhythm or organization into an atrial tachyarrhythmia, in 13% of patients (group 1), 44% (group 2), and 74% (group 3) respectively. CFAE alone, performed as the first step of the ablation in group 3, organized AF in only 1 patient. CONCLUSION In this study, the hybrid AF ablation strategy including antrum isolation and CFAE ablation had the highest likelihood of maintaining sinus rhythm in patients with longstanding permanent AF. Electrical isolation of the PVs, although inadequate if performed alone, is relevant to achieve long-term sinus rhythm maintenance after ablation. Bi-atrial CFAE ablation had a minimal impact on AF termination during ablation.


Circulation | 2000

First Human Experience With Pulmonary Vein Isolation Using a Through-the-Balloon Circumferential Ultrasound Ablation System for Recurrent Atrial Fibrillation

Andrea Natale; Ennio Pisano; Jeannie Shewchik; Dianna Bash; Raffaele Fanelli; Domenico Potenza; Pietro Santarelli; Robert A. Schweikert; Richard D. White; Walid Saliba; Logan Kanagaratnam; Patrick Tchou; Michael D. Lesh

BackgroundStandard mapping and ablation of focal sources of atrial fibrillation are associated with very long procedure times and low efficacy. An anatomic approach to complete pulmonary vein isolation could overcome these limitations. Methods and ResultsFifteen patients with atrial fibrillation refractory to medication underwent circumferential isolation of the pulmonary veins by using a novel catheter, with an ultrasound transducer (8-MHz) mounted near the tip, in a saline-filled balloon. Twelve atrial foci and/or atrial fibrillation triggers were identified in 9 patients (pulmonary vein locations: left upper, 3; right upper, 6; right middle, 1; right lower, 1; and left inferior, 1). In 5 patients, lesions were placed in the absence of any mapped triggers. Irrespective of trigger mapping, circumferential isolation of both upper pulmonary veins was attempted in all patients. The lower pulmonary veins were ablated when sinus rhythm activation mapping revealed evidence of a sleeve of atrial muscle in the vein. The median number of lesions per patient required to isolate 1 pulmonary vein was 4 (range, 1 to 29). After ablation, no evidence of narrowing was seen with repeat venography or follow-up computed tomography scan. After a mean follow-up of 35±6 weeks, 5 patients had recurrence of atrial fibrillation. Three responded to drugs that were previously ineffective, and 2 remained in atrial fibrillation. ConclusionsThis novel ultrasound ablation system can successfully isolate multiple pulmonary veins. At early follow-up, this approach seems to be effective in preventing recurrent atrial fibrillation in a significant number of patients.


Circulation | 2010

Periprocedural Stroke and Management of Major Bleeding Complications in Patients Undergoing Catheter Ablation of Atrial Fibrillation The Impact of Periprocedural Therapeutic International Normalized Ratio

Luigi Di Biase; J. David Burkhardt; Prasant Mohanty; Javier Sanchez; Rodney Horton; G. Joseph Gallinghouse; Dhanunjay Lakkireddy; Atul Verma; Yaariv Khaykin; Richard Hongo; Steven Hao; Salwa Beheiry; Gemma Pelargonio; Antonio Dello Russo; Michela Casella; Pietro Santarelli; Pasquale Santangeli; Paul J. Wang; Amin Al-Ahmad; Dimpi Patel; Sakis Themistoclakis; Aldo Bonso; Antonio Rossillo; Andrea Corrado; Antonio Raviele; Jennifer E. Cummings; Robert A. Schweikert; William R. Lewis; Andrea Natale

Background— Catheter ablation of atrial fibrillation is associated with the potential risk of periprocedural stroke, which can range between 1% and 5%. We developed a prospective database to evaluate the prevalence of stroke over time and to assess whether the periprocedural anticoagulation strategy and use of open irrigation ablation catheter have resulted in a reduction of this complication. Methods and Results— We collected data from 9 centers performing the same ablation procedure with the same anticoagulation protocol. We divided the patients into 3 groups: ablation with an 8-mm catheter off warfarin (group 1), ablation with an open irrigated catheter off warfarin (group 2), and ablation with an open irrigated catheter on warfarin (group 3). Outcome data on stroke/transient ischemic attack and bleeding complications during and early after the procedures were collected. Of 6454 consecutive patients in the study, 2488 were in group 1, 1348 were in group 2, and 2618 were in group 3. Periprocedural stroke/transient ischemic attack occurred in 27 patients (1.1%) in group 1 and 12 patients (0.9%) in group 2. Despite a higher prevalence of nonparoxysmal atrial fibrillation and more patients with CHADS2 (congestive heart failure, hypertension, age >75 years, diabetes mellitus, and prior stroke or transient ischemic attack) score >2, no stroke/transient ischemic attack was reported in group 3. Complications among groups 1, 2, and 3, including major bleeding (10 [0.4%], 11 [0.8%], and 10 [0.4%], respectively; P>0.05) and pericardial effusion (11 [0.4%], 11 [0.8%], and 12 [0.5%]; P>0.05), were equally distributed. Conclusion— The combination of an open irrigation ablation catheter and periprocedural therapeutic anticoagulation with warfarin may reduce the risk of periprocedural stroke without increasing the risk of pericardial effusion or other bleeding complications.

Collaboration


Dive into the Robert A. Schweikert's collaboration.

Top Co-Authors

Avatar

Andrea Natale

University of Texas at Austin

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Luigi Di Biase

Albert Einstein College of Medicine

View shared research outputs
Top Co-Authors

Avatar

Salwa Beheiry

California Pacific Medical Center

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge