Robert B. Knapp
Edgewood Chemical Biological Center
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Robert B. Knapp.
Analytica Chimica Acta | 1994
Arjun S. Bangalore; Gary W. Small; Roger J. Combs; Robert B. Knapp; Robert T. Kroutil
Abstract Signal processing techniques are developed to detect the presence of methanol vapour in an open path Fourier transform infrared (FTIR) measurement. An automated detection algorithm is implemented through the direct application of digital filtering and pattern recognition methods to short segments of FTIR interferograms. To test the data analysis methodology, a pollutant source of methanol vapour is simulated by the use of open air active bistatic, passive terrestrial, and passive laboratory spectrometer configurations. Approximately 30,000 interferograms collected from these experiments are used in optimizing and testing the digital filtering and pattern recognition techniques. Interferogram segment lengths ranging from 40 to 150 points are evaluated, along with different segment starting positions and filter bandpass widths. Interferogram segments as short as 40 points (0.01 cm optical retardation) are found to yield detection percentages approaching 100%. These results are achieved while maintaining an extremely low rate of false detections (0.5%).
Chemometrics and Intelligent Laboratory Systems | 1995
Ronald E. Shaffer; Gary W. Small; Roger J. Combs; Robert B. Knapp; Robert T. Kroutil
Abstract Signal processing techniques are described for open path Fourier transform infrared (FTIR) measurements that overcome fundamental limitations in conventional data analysis strategies. Bandpass digital filters are applied directly to FTIR interferograms to isolate spectral frequencies of interest, followed by pattern recognition analysis of segments of the filtered interferogram to provide an automated means for detecting a target analyte. In this work, four experimental variables are significant: (1) interferogram segment length, (2) interferogram segment position, (3) filter bandpass position, and (4) filter bandpass width. The limit of detection of a compound is directly related to the ability to choose optimal settings for these variables. Laboratory data collected when SF 6 was present in the optical path of the spectrometer are employed to perform a full factorial experimental design study of these four variables. Analysis of variance techniques are employed to provide a statistical means of interpreting the main and interaction effects existing among the variables. Based on these results, a protocol for designing a near-optimal bandpass filter is developed. Interferogram segment starting position, filter bandpass position, and filter bandpass width interaction effects are found to be statistically significant. It is concluded that these factors must be optimized jointly. Interferogram segment length is found to have the most overall influence on detection performance, but can be studied independently from the other variables. To validate the filter generation protocol developed with the laboratory data, additional work is performed with open path SF 6 data collected during a series of field trials. The results of this study demonstrate that the protocol is valid and can be extended to develop detection schemes for other compounds.
Vibrational Spectroscopy | 2001
Frederick W. Koehler; Gary W. Small; Roger J. Combs; Robert B. Knapp; Robert T. Kroutil
Abstract Passive Fourier transform infrared (FT-IR) spectrometry is used in the automated qualitative determination of sulfur dioxide (SO 2 ) in a stack monitoring application. Digital filtering and pattern recognition techniques are optimized and applied to short sections of interferograms in a methodology developed to minimize effects of background variation. Two data sets are investigated that were collected with four similarly configured FT-IR emission spectrometers positioned to monitor stack releases of SO 2 against low-angle sky backgrounds. In the two data sets, 98.2% of 39,058 and 99.58% of 386,260 FT-IR interferograms collected are correctly classified into analyte-active or analyte-inactive categories, respectively, representing the presence or absence of SO 2 in the field-of-view of the spectrometer. This work demonstrates the validity of the methodology with data collected from stack emissions, and shows that the methodology allows training and subsequent prediction of data sets composed of data collected with multiple spectrometers.
Applied Spectroscopy | 1996
Paul E. Field; Roger J. Combs; Robert B. Knapp
Infrared absorbance measurements through a gas flow cell are made with the closed-loop circulation of vapor/air mixtures equilibrated with the use of temperature-regulated aqueous solutions. Constant reproducible vapor pressures of organic solutes are established with the equilibrated aqueous solutions. The water solvent depresses the vapor pressure of the pure organic solutes of methanol, ethanol, isopropanol, acetone, and methyl ethyl ketone (MEK). Knowledge of the solution liquid mole fractions, the pure component vapor pressures, and the Wilson coefficients permits determination of the solute vapor pressures to within 2% accuracy. Reliable aqueous solution preparation requires only the correct weighings of pure constituent materials before mixing to achieve the targeted solute liquid mole fractions. Absorbances are measured for four of the five solutes over a range of seven concentrations and for MEK over four concentrations. These concentrations show the absorbance region of adherence to Beers law with an experimental precision of approximately ±2% for the solutes studied. Absorptivities that are calculated from the Beers law slope are compared to the available infrared absorbance data.
Applied Spectroscopy | 2000
Mutua J. Mattu; Gary W. Small; Roger J. Combs; Robert B. Knapp; Robert T. Kroutil
Multivariate calibration models are developed for the determination of sulfur dioxide (SO2) by passive Fourier transform infrared (FT-IR) remote sensing measurements. In a series of experiments designed to simulate the measurement of SO2 from industrial stack emissions, low-angle sky backgrounds are viewed through the windows of a heated flow-through gas cell. With this apparatus, infrared emission from the hot SO2 is measured against the cold background of the sky. The FT-IR interferogram data collected are analyzed directly in the construction of the calibration models. Bandpass digital filters are applied to the interferograms to isolate the modulated infrared frequencies corresponding to either the asymmetric or symmetric S–O stretching vibrations at 1361 and 1151 cm−1, respectively. Quantitative calibration models are constructed by submitting short segments of the filtered interferograms to partial least-squares regression analysis. The experimental design allows the impact of variation in the temperature of the SO2 to be evaluated for its effect on the calibration models. Three data sets are constructed consisting of data with increasing temperature variation. When the temperature variation in the data is less than 30 °C, the calibration models are able to achieve a cross-validation standard error of prediction (CV-SEP) of approximately 27 ppm-m across the 185 to 727 ppm-m range of density-corrected, path-averaged concentration. These calibration models are applied to an interferogram segment of only 250 points, and do not require any separate measurement of the infrared background. A comparison of the results from the interferogram-based analyses with those obtained in an analysis of single-beam spectral data reveals similar performances for the models computed with both types of data.
Applied Spectroscopy | 2000
Frederick W. Koehler; Gary W. Small; Roger J. Combs; Robert B. Knapp; Robert T. Kroutil
The qualitative determination of acetone is performed by passive Fourier transform infrared (FT-IR) spectrometry with data spanning two spectrometers. Digital filtering and piecewise linear discriminant analysis techniques are optimized and applied directly to short interferogram segments to eliminate background and instrument variation and then perform pattern recognition. Once optimized, this methodology classifies remote sensing data into categories representing the presence or absence of the analyte in an automated fashion. The addition to the training set of small numbers of interferogram data from a second spectrometer is evaluated in the creation of qualitative models robust with respect to differences between the instruments. Results of these experiments show that classification percentages averaged across all tested interferogram segments are improved from 76.2 ± 6.4% to 95.1 ± 2.2% with the addition of as few as 10 background interferograms collected in the field with the secondary instrument. The results also demonstrate that a broader, more optimal range of segments in the interferogram can be utilized when these background data are added from the secondary instrument. It is also found possible to standardize the data from the secondary instrument with blackbody background interferograms collected in the laboratory.
Proceedings of SPIE | 1996
Robert T. Kroutil; Roger J. Combs; Robert B. Knapp; J. P. Godfrey
The detection of gaseous ammonia with open-path Fourier transform spectrometry furnishes a means of accessing fugitive emissions from various industrial production processes by stack and site monitoring. This study relies on direct interferogram analysis of passive infrared data from open-air industrial and controlled laboratory environments. Direct interferogram analysis permits the identification of ammonia emissions by detection of the (nu) 2 spectral bands in the interferogram time domain.
Applied Spectroscopy | 2001
Patrick O. Idwasi; Gary W. Small; Roger J. Combs; Robert B. Knapp; Robert T. Kroutil
Digital filtering methods are evaluated for use in the automated detection of ethanol from passive Fourier transform infrared (FT-IR) data collected during laboratory and open-air remote sensing experiments. In applications in which analyte signals are overwhelmed by the overlapping signals of an interference, the use of multiple digital filters is observed to improve the sensitivity of the analyte detection. The detection strategy is based on the application of bandpass digital filters to short segments of the interferogram data collected by the FT-IR spectrometer. To implement the automated detection of a target analyte, the filtered interferogram segments are supplied as input to piecewise linear discriminant analysis. Through the use of a set of training data, discriminants are computed that can subsequently be applied to detect the presence of the analyte in an automated manner. This research focuses on the detection of ethanol vapor in the presence of an ammonia interference. A two-filter detection strategy based on the use of separate ethanol and ammonia filters is compared to an approach based on a single ethanol filter. Bandpass parameters of the digital filters and the interferogram segment location are optimized through the use of laboratory data in which ethanol and ammonia vapors are generated in a gas cell and viewed against various infrared background radiances. The filter and segment parameters obtained through this optimization are subsequently tested with field remote sensing data collected when the spectrometer is allowed to view ethanol and ammonia plumes generated from a heated stack. The two-filter strategy is found to outperform the single-filter approach with both the laboratory and field data in situations in which the ammonia interference dominates the ethanol signature.
Instrumentation Science & Technology | 1993
Roger J. Combs; Robert B. Knapp; Paul E. Field
ABSTRACT Mirror velocity variations in a continuous mirror drive Michelson interferometer result in erroneous interferogram sampling. The effects of both systematic and random mirror fluctuations are evaluated. Four methods of evaluation provide a means to quantify the importance of mirror velocity errors in the Fourier spectrometers performance as a spectroradiometer. The four methods are time interval signal analysis, sine wave test, optical chopper modulation, and examination of consecutive interferograms. Examination of consecutive interferograms includes the monitoring of a constant blackbody infrared radiation source as well as an interposed ammonia sample cell for wavenumber axis registration. Each method furnishes a known input to the interferometer modulation equation (i.e. 2uv=f) and permits an internal validation of the interferometer mirror velocity evaluation results.
Vibrational Spectroscopy-based Sensor Systems | 2002
Robert B. Knapp; Roger J. Combs; Robert T. Kroutil
Absorbance and transmittance spectra were acquired with ground-based passive FT-IR spectrometry for industrial stack evaluations and open-air controlled vapor generation experiments. The industrial stack effluents of sulfur dioxide and nitrous oxide were detected from a coal-burning power plant and an acid plant, respectively, with both MWIR and LWIR passive sensors. The controlled open-air experiments relied on only a LWIR sensor. These experiments produced plumes of methanol and ethanol at three and four elevated plume temperatures, respectively. Various vapor concentration pathlength produces of both ethanol and methanol were generated and gravimetrically monitored in the range from 0 to 300 ppm-m. The associated absorbance values for these concentration pathlength products were found to obey Beers Law for each elevate stack temperature of 125, 150, 175, and 200 degrees C.