Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Robert H. Beekman is active.

Publication


Featured researches published by Robert H. Beekman.


American Journal of Cardiology | 1990

Balloon aortic valvuloplasty: Results of the Valvuloplasty and Angioplasty of Congenital Anomalies Registry

Albert P. Rocchini; Robert H. Beekman; Giora Ben Shachar; Lee N. Benson; David C. Schwartz; Jean S. Kan

Data from 204 children and infants who underwent aortic balloon valvuloplasty between 1982 and 1986, reported to the Valvuloplasty and Angioplasty of Congenital Anomalies Registry, were reviewed. Valvuloplasty was successful in 192 of 204 children, reducing the peak systolic left ventricular ejection gradient from 77 +/- 2 to 30 +/- 1 mm Hg, p less than 0.001. The same degree of aortic stenosis gradients reduction was noted in both the 38 children under 1 year of age and in the 166 children over 1 year of age. Significant complications included death, aortic regurgitation and femoral artery thrombosis or damage. The incidence of these complications correlated with the age of the child, the ratio of valvuloplasty balloon size/anulus size, or both. The data suggest that percutaneous balloon valvuloplasty provides effective acute relief of valvar aortic stenosis in both infants and children. However, long-term follow-up data are necessary before balloon valvuloplasty can be established as a treatment of choice for congenital valvar aortic stenosis.


American Heart Journal | 1994

International experience with secundum atrial septal defect occlusion by the buttoned device

P. Syamasundar Rao; Eleftherios B. Sideris; Gerd Hausdort; Christian Rey; Thomas R. Lloyd; Robert H. Beekman; Ann Worms; François Bourlon; Eustaquio Onorato; Mohamed Khalilullah; Jorge Haddad

Several devices are available for transcatheter occlusion of atrial septal defect. This report describes the international experience with the buttoned device. During a 4.5-year period ending in February 1993, 180 transcatheter atrial septal defect occlusions were performed with the buttoned device. Patient age varied between 0.6 and 76 years and stretched atrial defect diameter between 5 and 25 mm. The defects were closed with 25 to 50 mm devices delivered through 8F (148 patients) or 9F (32 patients) sheaths. Twelve patients were adults whose defects were closed to prevent recurrence of cerebrovascular accidents caused by presumed paradoxic embolism. In the remaining patients the atrial defect was closed to treat the left-to-right shunt. The atrial septal defects were effectively occluded as demonstrated by (1) decrease in pulmonary-to-systemic flow ratio from 2.1 +/- 0.6 (mean +/- SD) to 1.05 +/- 0.1 (p < 0.01) by oximetry; (2) normalized S2 and disappearance of the diastolic murmur by auscultation; and (3) improvement in right ventricular volume overloading by echocardiogram. However, trivial to small shunts could be detected by color Doppler studies in 76 (45%) of 168 patients in whom such data are available. Complications included unbuttoning in 13 and whole-device embolization in 1. All patients remained stable, and retrieval of the device and surgical closure of the atrial septal defect were accomplished in 10 patients. Transcatheter retrieval was used in the remaining 4 patients. The incidence of unbuttoning, a major complication of the procedure, appeared to decrease with the increasing experience of the investigators and with device modification (third-generation). The follow-up duration varied between 1 month and 4 years. Six patients required surgery during the follow-up period. In the remaining patients (n = 160), clinical examination did not reveal signs of atrial shunts. Color Doppler studies revealed either complete disappearance of the previously demonstrated shunts or further diminution of their size. The results indicate that transcatheter occlusion of the atrial septal defects with buttoned devices is feasible, relatively safe, and effective, and it appears to be a viable alternative to surgery for some patients with secundum atrial septal defect. Complications are infrequent and should improve with experience.


Pediatrics | 2009

Role of Pulse Oximetry in Examining Newborns for Congenital Heart Disease: A Scientific Statement from the AHA and AAP

William T. Mahle; Jane W. Newburger; G. Paul Matherne; Frank C. Smith; Tracey R. Hoke; Robert Koppel; Samuel S. Gidding; Robert H. Beekman; Scott D. Grosse

BACKGROUND: The purpose of this statement is to address the state of evidence on the routine use of pulse oximetry in newborns to detect critical congenital heart disease (CCHD). METHODS AND RESULTS: A writing group appointed by the American Heart Association and the American Academy of Pediatrics reviewed the available literature addressing current detection methods for CCHD, burden of missed and/or delayed diagnosis of CCHD, rationale of oximetry screening, and clinical studies of oximetry in otherwise asymptomatic newborns. MEDLINE database searches from 1966 to 2008 were done for English-language papers using the following search terms: congenital heart disease, pulse oximetry, physical examination, murmur, echocardiography, fetal echocardiography, and newborn screening. The reference lists of identified papers were also searched. Published abstracts from major pediatric scientific meetings in 2006 to 2008 were also reviewed. The American Heart Association classification of recommendations and levels of evidence for practice guidelines were used. In an analysis of pooled studies of oximetry assessment performed after 24 hours of life, the estimated sensitivity for detecting CCHD was 69.6%, and the positive predictive value was 47.0%; however, sensitivity varied dramatically among studies from 0% to 100%. False-positive screens that required further evaluation occurred in only 0.035% of infants screened after 24 hours. CONCLUSIONS: Currently, CCHD is not detected in some newborns until after their hospital discharge, which results in significant morbidity and occasional mortality. Furthermore, routine pulse oximetry performed on asymptomatic newborns after 24 hours of life, but before hospital discharge, may detect CCHD. Routine pulse oximetry performed after 24 hours in hospitals that have on-site pediatric cardiovascular services incurs very low cost and risk of harm. Future studies in larger populations and across a broad range of newborn delivery systems are needed to determine whether this practice should become standard of care in the routine assessment of the neonate.


American Journal of Cardiology | 1993

Usefulness of the bidirectional Glenn procedure as staged reconstruction for the functional single ventricle

Ara K. Pridjian; Alan M. Mendelsohn; Flavian M. Lupinetti; Robert H. Beekman; Macdonald Dick; Gerald A. Serwer; Edward L. Bove

The bidirectional Glenn operation may be particularly useful as an intermediate procedure before Fontan correction in high-risk patients. From October 1989 through February 1992, 50 patients 1 to 60 months old (median 12) have undergone a bidirectional Glenn operation. Diagnoses included hypoplastic left heart syndrome in 21 patients, pulmonary atresia with intact ventricular septum in 10, tricuspid valve atresia in 9, other complex univentricular heart defects in 9, and Ebsteins anomaly in 1. Mean pulmonary vascular resistance was 2.2 +/- 0.2 Wood U (range 0.5 to 7.3) and mean pulmonary artery area Nakata index was 318 +/- mm2/m2 (range 80 to 821). Additional procedures were performed in 17 patients, including pulmonary artery reconstruction in 15 (29%) and bilateral caval anastomoses in 5 (10%). There were 4 hospital deaths (8%). Two deaths resulted from myocardial infarction in patients with pulmonary atresia with intact ventricular septum and sinusoids and 1 from severe pulmonary vascular disease in a patient with hypoplastic left heart syndrome. There was 1 late death from pneumonia. Actuarial survival is 92 +/- 4% at 1 month and beyond, with a mean follow-up of 13.4 +/- 1 months. Risk factor analysis showed that pulmonary vascular resistance > 3 Wood U and pulmonary artery distortion were associated with increased mortality. Twelve patients have undergone a Fontan procedure at a mean duration after bidirectional Glenn of 18 months with 1 death (8%). The bidirectional Glenn procedure provides excellent palliation in high-risk patients and appears useful as a staging procedure before Fontan correction.


Pediatrics | 2012

Endorsement of Health and Human Services Recommendation for Pulse Oximetry Screening for Critical Congenital Heart Disease

Section on Cardiology; William T. Mahle; Gerard R. Martin; Robert H. Beekman; W. Robert Morrow; Geoffrey L. Rosenthal; Christopher S. Snyder; L. LuAnn Minich; Seema Mital; Jeffrey A. Towbin; James S. Tweddell

Incorporation of pulse oximetry to the assessment of the newborn infant can enhance detection of critical congenital heart disease (CCHD). Recently, the Secretary of Health and Human Services (HHS) recommended that screening for CCHD be added to the uniform screening panel. The American Academy of Pediatrics (AAP) has been a strong advocate of early detection of CCHD and fully supports the decision of the Secretary of HHS. The AAP has published strategies for the implementation of pulse oximetry screening, which addressed critical issues such as necessary equipment, personnel, and training, and also provided specific recommendations for assessment of saturation by using pulse oximetry as well as appropriate management of a positive screening result. The AAP is committed to the safe and effective implementation of pulse oximetry screening and is working with other advocacy groups and governmental agencies to promote pulse oximetry and to support widespread surveillance for CCHD. Going forward, AAP chapters will partner with state health departments to implement the new screening strategy for CCHD and will work to ensure that there is an adequate system for referral for echocardiographic/pediatric cardiac evaluation after a positive screening result. It is imperative that AAP members engage their respective policy makers in adopting and funding the recommendations made by the Secretary of HHS.


Circulation | 2009

Role of Pulse Oximetry in Examining Newborns for Congenital Heart Disease: A Scientific Statement From the American Heart Association and American Academy of Pediatrics

William T. Mahle; Jane W. Newburger; G. Paul Matherne; Frank C. Smith; Tracey R. Hoke; Robert Koppel; Samuel S. Gidding; Robert H. Beekman; Scott D. Grosse

Background— The purpose of this statement is to address the state of evidence on the routine use of pulse oximetry in newborns to detect critical congenital heart disease (CCHD). Methods and Results— A writing group appointed by the American Heart Association and the American Academy of Pediatrics reviewed the available literature addressing current detection methods for CCHD, burden of missed and/or delayed diagnosis of CCHD, rationale of oximetry screening, and clinical studies of oximetry in otherwise asymptomatic newborns. MEDLINE database searches from 1966 to 2008 were done for English-language papers using the following search terms: congenital heart disease, pulse oximetry, physical examination, murmur, echocardiography, fetal echocardiography, and newborn screening. The reference lists of identified papers were also searched. Published abstracts from major pediatric scientific meetings in 2006 to 2008 were also reviewed. The American Heart Association classification of recommendations and levels of evidence for practice guidelines were used. In an analysis of pooled studies of oximetry assessment performed after 24 hours of life, the estimated sensitivity for detecting CCHD was 69.6%, and the positive predictive value was 47.0%; however, sensitivity varied dramatically among studies from 0% to 100%. False-positive screens that required further evaluation occurred in only 0.035% of infants screened after 24 hours. Conclusions— Currently, CCHD is not detected in some newborns until after their hospital discharge, which results in significant morbidity and occasional mortality. Furthermore, routine pulse oximetry performed on asymptomatic newborns after 24 hours of life, but before hospital discharge, may detect CCHD. Routine pulse oximetry performed after 24 hours in hospitals that have on-site pediatric cardiovascular services incurs very low cost and risk of harm. Future studies in larger populations and across a broad range of newborn delivery systems are needed to determine whether this practice should become standard of care in the routine assessment of the neonate.


Pediatrics | 2005

Cardiovascular health supervision for individuals affected by duchenne or becker muscular dystrophy

Thomas S. Klitzner; Robert H. Beekman; Frank M. Galioto; Thomas K. Jones; Peter B. Manning; W. Robert Morrow; Jane W. Newburger; John W. Moore; Linda H. Cripe; Lynn Colegrove

Duchenne muscular dystrophy is the most common and severe form of the childhood muscular dystrophies. The disease is typically diagnosed between 3 and 7 years of age and follows a predictable clinical course marked by progressive skeletal muscle weakness with loss of ambulation by 12 years of age. Death occurs in early adulthood secondary to respiratory or cardiac failure. Becker muscular dystrophy is less common and has a milder clinical course but also results in respiratory and cardiac failure. The natural history of the cardiomyopathy in these diseases has not been well established. As a result, patients traditionally present for cardiac evaluation only after clinical symptoms become evident. The purpose of this policy statement is to provide recommendations for optimal cardiovascular evaluation to health care specialists caring for individuals in whom the diagnosis of Duchenne or Becker muscular dystrophy has been confirmed.


Catheterization and Cardiovascular Interventions | 2009

Adverse event rates in congenital cardiac catheterization — A multi-center experience†

Lisa Bergersen; Audrey C. Marshall; Kimberlee Gauvreau; Robert H. Beekman; Russel Hirsch; Susan Foerster; David T. Balzer; Julie A. Vincent; William E. Hellenbrand; Ralf Holzer; John P. Cheatham; John W. Moore; James E. Lock; Kathy J. Jenkins

Objectives: To describe case mix variation among institutions, and report adverse event rates in congenital cardiac catheterization by case type. Background: Reported adverse event rates for patients with congenital heart disease undergoing cardiac catheterization vary considerably, due to non‐comparable standards of data inclusion, and highly variable case mix. Methods: The Congenital Cardiac Catheterization Outcomes Project (C3PO) has been capturing case characteristics and adverse events (AE) for all cardiac catheterizations performed at six pediatric institutions. Validity and completeness of data were independently audited. Results: Between 2/1/07 and 4/30/08, 3855 cases (670 biopsy, 1037 diagnostic, and 2148 interventional) were recorded, median number of cases per site 480 (308 to 1526). General anesthesia was used in 70% of cases (28 to 99%), and 22% of cases (15 to 26%) were non‐electively or emergently performed. Three institutions performed a higher proportion of interventions during a case, 72 to 77% compared to 56 to 58%. The median rate of AE reported per institution was 16%, ranging from 5 to 18%. For interventional cases the median rate of AE reported per institution was 19% (7 to 25%) compared to 10% for diagnostic cases (6 to 16%). The incidence of AE was significantly higher for interventional compared to diagnostic cases (20% vs 10%, p<0.001), as was the incidence of higher severity AE (9% vs 5%, p<0.001). Adverse events in biopsy cases were uncommon. Conclusions: In this multi‐institutional cohort, the incidence of AE is higher among interventional compared to diagnostic cases, and is very low among biopsy cases. Equitable comparisons among institutions will require the development and application of risk adjustment methods.


American Journal of Cardiology | 1994

Late follow-up of balloon angioplasty in children with a native coarctation of the aorta

Alan M. Mendelsohn; Thomas R. Lloyd; Dennis C. Crowley; Satinder K. Sandhu; Keith C. Kocis; Robert H. Beekman

Between May 1984 and April 1993, 59 children underwent balloon angioplasty of a native coarctation at our institution. The follow-up protocol included a cardiac catheterization 1 to 2 years after angioplasty, which was performed in 90% of patients with > or = 2 years follow-up. Angioplasty caused an acute decrease in peak systolic gradient from 46 +/- 2 to 15 +/- 2 mm Hg, without early aneurysm or emergent surgical intervention in any patient. Based on follow-up data, a satisfactory result was obtained in 38 patients (64%; 70% confidence limit: 58% to 71%), defined as a residual systolic gradient < 20 mm Hg and no aneurysm. In these patients the gradient decreased acutely from 43 +/- 2 to 9 +/- 1 mm Hg, was 6 +/- 1 mm Hg at follow-up catheterization, and 9 +/- 2 mm Hg by clinical evaluation 4.4 +/- 0.3 years after angioplasty. Twenty-one patients (36%; 70% confidence limit: 29% to 42%) had an unsatisfactory result due to a residual gradient > or = 20 mm Hg (n = 19) or aneurysm formation (n = 3), or both. Restenosis occurred in 6 patients, and occurred more in infants than in children > or = 12 months of age (3 of 5 infants vs 3 of 41 children, p = 0.01). Thus, balloon angioplasty provides an effective initial treatment strategy for native coarctation in most children aged > 12 months.


Journal of the American College of Cardiology | 1989

Aortic aneurysm after patch aortoplasty repair of coarctation: A prospective analysis of prevalence, screening tests and risks

Burt I. Bromberg; Robert H. Beekman; Albert P. Rocchini; A. Rebecca Snider; Estelle R. Bank; Kathleen P. Heidelberger; Amnon Rosenthal

Twenty-nine children were evaluated prospectively for the presence of an aortic aneurysm at the repair site 1 to 19 years after patch aortoplasty repair of coarctation of the aorta. In each child, noninvasive evaluation included a chest X-ray film, computed tomography of the chest and two-dimensional echocardiography. The presence and size of an aortic aneurysm were determined quantitatively by measuring the ratio of the diameter of the thoracic aorta at the repair site to the diameter of the aorta at the diaphragm (aortic ratio). An aortic ratio of greater than or equal to 1.5 was judged abnormal and was shown to be significantly greater than the aortic ratio of a normal control group. An aortogram was obtained in each child if any noninvasive screening test was found to be abnormal. As assessed by the aortogram, the prevalence of aortic aneurysm was 24% in this patient group. The sensitivity of echocardiography and chest computed tomography for detecting an aneurysm was 71% and 66%, and the specificity 76% and 85%, respectively. The chest X-ray film was 100% sensitive and 68% specific in determining the presence of an aneurysm. Although the data are not statistically significant, they suggest that children undergoing patch aortoplasty as the primary procedure (rather than a reoperation after earlier resection), and children in whom a Dacron patch is utilized may be at increased risk for aneurysm formation.(ABSTRACT TRUNCATED AT 250 WORDS)

Collaboration


Dive into the Robert H. Beekman's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kathy J. Jenkins

Boston Children's Hospital

View shared research outputs
Top Co-Authors

Avatar

Amnon Rosenthal

Boston Children's Hospital

View shared research outputs
Top Co-Authors

Avatar

Gerard R. Martin

Children's National Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Russel Hirsch

Cincinnati Children's Hospital Medical Center

View shared research outputs
Top Co-Authors

Avatar

Lisa Bergersen

Boston Children's Hospital

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge