Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Robert-Jan van Geuns is active.

Publication


Featured researches published by Robert-Jan van Geuns.


European Journal of Cardio-Thoracic Surgery | 2014

2014 ESC/EACTS Guidelines on myocardial revascularization The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) Developed with the special contribution of the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

Philippe Kolh; Stephan Windecker; Fernando Alfonso; Jean-Philippe Collet; Jochen Cremer; Volkmar Falk; Gerasimos Filippatos; Christian W. Hamm; Stuart J. Head; Peter Jüni; A. Pieter Kappetein; Adnan Kastrati; Juhani Knuuti; Ulf Landmesser; Günther Laufer; Franz-Josef Neumann; Dimitrios J. Richter; Patrick Schauerte; Miguel Sousa Uva; Giulio G. Stefanini; David P. Taggart; Lucia Torracca; Marco Valgimigli; William Wijns; Adam Witkowski; Jose Luis Zamorano; Stephan Achenbach; Helmut Baumgartner; Jeroen J. Bax; Héctor Bueno

Authors/Task Force members: Stephan Windecker* (ESC Chairperson) (Switzerland), Philippe Kolh* (EACTS Chairperson) (Belgium), Fernando Alfonso (Spain), Jean-Philippe Collet (France), Jochen Cremer (Germany), Volkmar Falk (Switzerland), Gerasimos Filippatos (Greece), Christian Hamm (Germany), Stuart J. Head (The Netherlands), Peter Jüni (Switzerland), A. Pieter Kappetein (The Netherlands), Adnan Kastrati (Germany), Juhani Knuuti (Finland), Ulf Landmesser (Switzerland), Günther Laufer (Austria), Franz-Josef Neumann (Germany), Dimitrios J. Richter (Greece), Patrick Schauerte (Germany), Miguel Sousa Uva (Portugal), Giulio G. Stefanini (Switzerland), David Paul Taggart (UK), Lucia Torracca (Italy), Marco Valgimigli (Italy), William Wijns (Belgium), and Adam Witkowski (Poland).


The Lancet | 2008

Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial

Stephan Windecker; Patrick W. Serruys; Simon Wandel; Pawel Buszman; Stanisław Trznadel; Axel Linke; Karsten Lenk; Thomas Ischinger; Volker Klauss; Franz R. Eberli; Roberto Corti; William Wijns; Marie-Claude Morice; Carlo Di Mario; Simon J. Davies; Robert-Jan van Geuns; Pedro Eerdmans; Gerrit Anne van Es; B Meier; Peter Jüni

BACKGROUND A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer). METHODS We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26). INTERPRETATION Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes. FUNDING Biosensors Europe SA, Switzerland.


The New England Journal of Medicine | 2010

Comparison of zotarolimus-eluting and everolimus-eluting coronary stents.

Patrick W. Serruys; Sigmund Silber; Scot Garg; Robert-Jan van Geuns; Gert Richardt; Pawel Buszman; Henning Kelbæk; Adrianus J. van Boven; Sjoerd H. Hofma; Axel Linke; Volker Klauss; William Wijns; Carlos Macaya; Philippe Garot; Carlo DiMario; Ganesh Manoharan; Ran Kornowski; Thomas Ischinger; Antonio L. Bartorelli; Jacintha Ronden; Marco Bressers; Manuela Negoita; Frank van Leeuwen; Stephan Windecker

BACKGROUND New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed by the Food and Drug Administration. METHODS In this multicenter, noninferiority trial with minimal exclusion criteria, we randomly assigned 2292 patients to undergo treatment with coronary stents releasing either zotarolimus or everolimus. Twenty percent of patients were randomly selected for repeat angiography at 13 months. The primary end point was target-lesion failure, defined as a composite of death from cardiac causes, any myocardial infarction (not clearly attributable to a nontarget vessel), or clinically indicated target-lesion revascularization within 12 months. The secondary angiographic end point was the extent of in-stent stenosis at 13 months. RESULTS At least one off-label criterion for stent placement was present in 66% of patients. The zotarolimus-eluting stent was noninferior to the everolimus-eluting stent with respect to the primary end point, which occurred in 8.2% and 8.3% of patients, respectively (P<0.001 for noninferiority). There were no significant between-group differences in the rate of death from cardiac causes, any myocardial infarction, or revascularization. The rate of stent thrombosis was 2.3% in the zotarolimus-stent group and 1.5% in the everolimus-stent group (P=0.17). The zotarolimus-eluting stent was also noninferior regarding the degree (+/-SD) of in-stent stenosis (21.65+/-14.42% for zotarolimus vs. 19.76+/-14.64% for everolimus, P=0.04 for noninferiority). In-stent late lumen loss was 0.27+/-0.43 mm in the zotarolimus-stent group versus 0.19+/-0.40 mm in the everolimus-stent group (P=0.08). There were no significant between-group differences in the rate of adverse events. CONCLUSIONS At 13 months, the new-generation zotarolimus-eluting stent was found to be noninferior to the everolimus-eluting stent in a population of patients who had minimal exclusion criteria. (ClinicalTrials.gov number, NCT00617084.)


The Lancet | 2012

Everolimus-eluting stent versus bare-metal stent in ST-segment elevation myocardial infarction (EXAMINATION): 1 year results of a randomised controlled trial

Manel Sabaté; Angel Cequier; Andrés Iñiguez; Antonio Serra; Rosana Hernández-Antolín; Vicente Mainar; Marco Valgimigli; Maurizio Tespili; Pieter den Heijer; Armando Bethencourt; Nicolás Vázquez; Joan Antoni Gómez-Hospital; José Antonio Baz; Victoria Martín-Yuste; Robert-Jan van Geuns; Fernando Alfonso; Pascual Bordes; Matteo Tebaldi; Monica Masotti; Antonio Silvestro; Bianca Backx; Salvatore Brugaletta; Gerrit Anne van Es; Patrick W. Serruys

BACKGROUND Everolimus-eluting stent (EES) reduces the risk of restenosis in elective percutaneous coronary intervention. However, the use of drug-eluting stent in patients with ST-segment elevation myocardial infarction (STEMI) is still controversial. Data regarding the performance of second-generation EES in this setting are scarce. We report the 1-year result of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) trial, comparing EES with bare-metal stents (BMS) in patients with STEMI. METHODS This multicentre, prospective, randomised, all-comer controlled trial was done in 12 medical centres in three countries. Between Dec 31, 2008, and May 15, 2010, we recruited patients with STEMI up to 48 h after the onset of symptoms requiring emergent percutaneous coronary intervention. Patients were randomly assigned (ratio 1:1) to receive EES or BMS. Randomisation was in blocks of four or six patients, stratified by centre and centralised by telephone. Patients were masked to treatment. The primary endpoint was the patient-oriented combined endpoint of all-cause death, any recurrent myocardial infarction, and any revascularisation at 1 year and was analysed by intention to treat. The secondary endpoints of the study included the device-oriented combined endpoint of cardiac death, target vessel myocardial infarction or target lesion revascularisation, and rates of all cause or cardiac death, recurrent myocardial infarction, target lesion or target vessel revascularisation, stent thrombosis, device and procedure success, and major and minor bleeding. This trial is registered with ClinicalTrials.gov, number NCT00828087. FINDINGS Of the 1504 patients randomised, 1498 patients were randomly assigned to receive EES (n=751) or BMS (n=747). The primary endpoint was similar in both groups (89 [11·9%] of 751 patients in the EES group vs 106 [14·2%] of 747 patients in the BMS group; difference -2·34 [95% CI -5·75 to 1·07]; p=0·19). Device-oriented endpoint (44 [5·9%] in the EES group vs 63 [8·4%] in the BMS group; difference -2·57 [95% CI -5·18 to 0·03]; p=0·05) did not differ between groups, although rates of target lesion and vessel revascularisation were significantly lower in the EES group (16 [2·1%] vs 37 [5·0%], p=0·003, and 28 [3·7%] vs 51 [6·8%], p=0·0077, respectively). Rates of all cause (26 [3·5%] for EES vs 26 [3·5%] for BMS, p=1·00) or cardiac death (24 [3·2%] for EES vs 21 [2·8%] for BMS, p=0·76) or myocardial infarction (10 [1·3%] vs 15 [2·0%], p=0·32) did not differ between groups. Stent thrombosis rates were significantly lower in the EES group (4 [0·5%] patients with definite stent thrombosis in the EES group vs 14 [1·9%] in the BMS group and seven [0·9%] patients with definite or probable stent thrombosis in the EES group vs 19 [2·5%] in the BMS group, both p=0·019). Although device success rate was similar between groups, procedure success rate was significantly higher in the EES group (731 [97·5%] vs 705 [94·6%]; p=0·0050). Finally, Bleeding rates at 1 year were comparable between groups (29 [3·9%] patients in the EES group vs 39 [5·2%] in the BMS group; p=0·19). INTERPRETATION The use of EES compared with BMS in the setting of STEMI did not lower the patient-oriented endpoint. However, at the stent level both rates of target lesion revascularisation and stent thrombosis were reduced in recipients of EES. FUNDING Spanish Heart Foundation.


European Heart Journal | 2010

An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: A LEADERS trial sub-study

Evelyn Regar; Patrick W. Serruys; Konstantinos Dimopoulos; Willem J. van der Giessen; Robert-Jan van Geuns; Giuseppe Ferrante; Simon Wandel; Stephan Windecker; Gerrit Anne van Es; Pedro Eerdmans; Peter Jüni; Carlo Di Mario

AIMS Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial. METHODS AND RESULTS Fifty-six consecutive patients underwent OCT during angiographic follow-up at 9 months. OCT images were acquired using a non-occlusive technique at a pullback speed of 3 mm/s. Data were analysed using a Bayesian hierarchical random-effects model, which accounted for the correlation of lesion characteristics within patients and implicitly assigned analytical weights to each lesion depending on the number of struts observed per lesion. Primary outcome was the difference in percentage of uncovered struts between BESs and SESs. Twenty patients were included in the analysis in the BES group (29 lesions with 4592 struts) and 26 patients in the SES group (35 lesions with 6476 struts). A total of 83 struts were uncovered in the BES group and 407 out of 6476 struts were uncovered in the SES group [weighted difference -1.4%, 95% confidence interval (CI) -3.7 to 0.0, P = 0.04]. Results were similar after adjustment for pre-procedure lesion length, reference vessel diameter, number of implanted study stents, and presence of stent overlap. There were three lesions in the BES group and 15 lesions in the SES group that had > or =5% of all struts uncovered (difference -33.1%, 95% CI -61.7 to -10.3, P < 0.01). CONCLUSION Strut coverage at an average follow-up of 9 months appears to be more complete in patients allocated to BESs when compared with SESs. The impact of this difference on clinical outcome and, in particular, on the risk of late stent thrombosis is yet to be determined.


American Journal of Cardiology | 2002

Usefulness of multislice computed tomography for detecting obstructive coronary artery disease

Koen Nieman; Bj Rensing; Robert-Jan van Geuns; Arie Munne; J. Ligthart; Peter M.T. Pattynama; Gabriel P. Krestin; Patrick W. Serruys; Pim J. de Feyter

The latest generation of multislice spiral computed tomography (MSCT) scanners is capable of noninvasive coronary angiography. We evaluated its diagnostic accuracy to detect stenotic coronary artery disease (CAD). In 53 patients with suspected CAD, contrast-enhanced MSCT and conventional angiography were performed. The CT data were acquired within a single breathhold, and isocardiophasic slices were reconstructed by means of retrospective electrocardiographic gating. Coronary segments of > or = 2 mm in diameter, measured by quantitative angiography, were evaluated. In 70% of the 358 available segments, image quality was regarded as adequate for assessment. The overall sensitivity, specificity, and positive and negative predictive values to detect > or = 50% stenotic lesions in the assessable segments were 82% (42 of 51 lesions), 93% (285 of 307 nonstenotic segments), and 66% and 97%, respectively, regarding conventional quantitative angiography as the gold standard. Proximal segments were assessable in 92%, and distal segments and side branches in 71% and 50%, respectively. Including the undetected lesions in non-assessable segments, overall sensitivity decreased to 61% but remained 82% for lesions in proximal coronary segments. MSCT correctly predicted absent, single, or multiple lesions in 55% of patients. Thus, despite potentially high image quality, current MSCT protocols offer only reasonable diagnostic accuracy in an unselected patient group with a high prevalence of CAD.


Eurointervention | 2014

Dynamics of vessel wall changes following the implantation of the Absorb everolimus-eluting bioresorbable vascular scaffold: a multi-imaging modality study at 6, 12, 24 and 36 months

Patrick W. Serruys; Yoshinobu Onuma; Hector M. Garcia-Garcia; Takashi Muramatsu; Robert-Jan van Geuns; Bernard De Bruyne; Dariusz Dudek; Leif Thuesen; Pieter C. Smits; Bernard Chevalier; Dougal McClean; Jacques J. Koolen; Stephan Windecker; Robert Whitbourn; Ian T. Meredith; Cecile Dorange; Susan Veldhof; Karine Miquel Hebert; Richard Rapoza; John Ormiston

AIMS To assess observations with multimodality imaging of the Absorb bioresorbable everolimus-eluting vascular scaffold performed in two consecutive cohorts of patients who were serially investigated either at 6 and 24 months or at 12 and 36 months. METHODS AND RESULTS In the ABSORB multicentre single-arm trial, 45 patients (cohort B1) and 56 patients (cohort B2) underwent serial invasive imaging, specifically quantitative coronary angiography (QCA), intravascular ultrasound (IVUS), radiofrequency backscattering (IVUS-VH) and optical coherence tomography (OCT). Between one and three years, late luminal loss remained unchanged (6 months: 0.19 mm, 1 year: 0.27 mm, 2 years: 0.27 mm, 3 years: 0.29 mm) and the in-segment angiographic restenosis rate for the entire cohort B (n=101) at three years was 6%. On IVUS, mean lumen, scaffold, plaque and vessel area showed enlargement up to two years. Mean lumen and scaffold area remained stable between two and three years whereas significant reduction in plaque behind the struts occurred with a trend toward adaptive restrictive remodelling of EEM. Hyperechogenicity of the vessel wall, a surrogate of the bioresorption process, decreased from 23.1% to 10.4% with a reduction of radiofrequency backscattering for dense calcium and necrotic core. At three years, the count of strut cores detected on OCT increased significantly, probably reflecting the dismantling of the scaffold; 98% of struts were covered. In the entire cohort B (n=101), the three-year major adverse cardiac event rate was 10.0% without any scaffold thrombosis. CONCLUSIONS The current investigation demonstrated the dynamics of vessel wall changes after implantation of a bioresorbable scaffold, resulting at three years in stable luminal dimensions, a low restenosis rate and a low clinical major adverse cardiac events rate. CLINICAL TRIAL REGISTRATION INFORMATION http://www.clinicaltrials.gov/ct2/show/NCT00856856.


Circulation-cardiovascular Interventions | 2012

First Serial Assessment at 6 Months and 2 Years of the Second Generation of Absorb Everolimus-Eluting Bioresorbable Vascular Scaffold A Multi-Imaging Modality Study

John Ormiston; Patrick W. Serruys; Yoshinobu Onuma; Robert-Jan van Geuns; Bernard De Bruyne; Dariusz Dudek; Leif Thuesen; Pieter C. Smits; Bernard Chevalier; Dougal McClean; Jacques J. Koolen; Stephan Windecker; Robert Whitbourn; Ian T. Meredith; Cecile Dorange; Susan Veldhof; Karine Miquel Hebert; Richard Rapoza; Hector M. Garcia-Garcia

Background—Nonserial observations have shown this bioresorbable scaffold to have no signs of area reduction at 6 months and recovery of vasomotion at 1 year. Serial observations at 6 months and 2 years have to confirm the absence of late restenosis or unfavorable imaging outcomes. Methods and Results—The ABSORB trial is a multicenter single-arm trial assessing the safety and performance of an everolimus-eluting bioresorbable vascular scaffold. Forty-five patients underwent serial invasive imaging, such as quantitative coronary angiography, intravascular ultrasound, and optical coherence tomography at 6 and 24 months of follow-up. From 6 to 24 months, late luminal loss increased from 0.16±0.18 to 0.27±0.20 mm on quantitative coronary angiography, with an increase in neointima of 0.68±0.43 mm2 on optical coherence tomography and 0.17±0.26 mm2 on intravascular ultrasound. Struts still recognizable on optical coherence tomography at 2 years showed 99% of neointimal coverage with optical and ultrasonic signs of bioresorption accompanied by increase in mean scaffold area compared with baseline (0.54±1.09 mm2 on intravascular ultrasound, P=0.003 and 0.77±1.33 m2 on optical coherence tomography, P=0.016). Two-year major adverse cardiac event rate was 6.8% without any scaffold thrombosis. Conclusions—This serial analysis of the second generation of the everolimus-eluting bioresorbable vascular scaffold confirmed, at medium term, the safety and efficacy of the new device. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT00856856.


Journal of the American College of Cardiology | 2010

Value of the SYNTAX score for risk assessment in the all-comers population of the randomized multicenter LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial

Joanna J. Wykrzykowska; Scot Garg; Chrysafios Girasis; Ton de Vries; Marie-Angèle Morel; Gerrit Anne van Es; Pawel Buszman; Axel Linke; Thomas Ischinger; Volker Klauss; Roberto Corti; Franz R. Eberli; William Wijns; Marie-Claude Morice; Carlo Di Mario; Robert-Jan van Geuns; Peter Jüni; Stephan Windecker; Patrick W. Serruys

OBJECTIVES We aimed to assess the predictive value of the SYNTAX score (SXscore) for major adverse cardiac events in the all-comers population of the LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial. BACKGROUND The SXscore has been shown to be an effective predictor of clinical outcomes in patients with multivessel disease undergoing percutaneous coronary intervention. METHODS The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the LEADERS trial (patients after surgical revascularization were excluded). Post hoc analysis was performed by stratifying clinical outcomes at 1-year follow-up, according to 1 of 3 SXscore tertiles. RESULTS The 1,397 patients were divided into tertiles based on the SXscore in the following fashion: SXscore<or=8 (SXlow) (n=464), SXscore>8 and <or=16 (SXmid) (n=472), and SXscore>16 (SXhigh) (n=461). At 1-year follow-up, there was a significantly lower number of patients with major cardiac event-free survival in the highest tertile of SXscore (SXlow=92.2%, SXmid=91.1%, and SXhigh=84.6%; p<0.001). Death occurred in 1.5% of SXlow patients, 2.1% of SXmid patients, and 5.6% of SXhigh patients (hazard ratio [HR]: 1.97, 95% confidence interval [CI]: 1.29 to 3.01; p=0.002). The myocardial infarction rate tended to be higher in the SXhigh group. Target vessel revascularization was 11.3% in the SXhigh group compared with 6.3% and 7.8% in the SXlow and SXmid groups, respectively (HR: 1.38, 95% CI: 1.1 to 1.75; p=0.006). Composite of cardiac death, myocardial infarction, and clinically indicated target vessel revascularization was 7.8%, 8.9%, and 15.4% in the SXlow, SXmid, and SXhigh groups, respectively (HR: 1.47, 95% CI: 1.19 to 1.81; p<0.001). CONCLUSIONS The SXscore, when applied to an all-comers patient population treated with drug-eluting stents, may allow prospective risk stratification of patients undergoing percutaneous coronary intervention. (LEADERS Trial Limus Eluted From A Durable Versus ERodable Stent Coating; NCT00389220).


European Heart Journal | 2014

In vivo detection of high-risk coronary plaques by radiofrequency intravascular ultrasound and cardiovascular outcome: results of the ATHEROREMO-IVUS study.

Jin M. Cheng; Hector M. Garcia-Garcia; Sanneke P.M. de Boer; Isabella Kardys; Jung Ho Heo; K. Martijn Akkerhuis; Rohit M. Oemrawsingh; Ron T. van Domburg; Jurgen Ligthart; Karen Witberg; Evelyn Regar; Patrick W. Serruys; Robert-Jan van Geuns; Eric Boersma

AIMS Acute coronary syndromes (ACS) are mostly caused by plaque rupture. This study aims to investigate the prognostic value of in vivo detection of high-risk coronary plaques by intravascular ultrasound (IVUS) in patients undergoing coronary angiography. METHODS AND RESULTS Between November 2008 and January 2011, IVUS of a non-culprit coronary artery was performed in 581 patients who underwent coronary angiography for ACS (n = 318) or stable angina (n = 263). Primary endpoint was major adverse cardiac events (MACEs) defined as mortality, ACS, or unplanned coronary revascularization. Culprit lesion-related events were not counted. Cumulative Kaplan-Meier incidence of 1-year MACE was 7.8%. The presence of IVUS virtual histology-derived thin-cap fibroatheroma (TCFA) lesions (present 10.8% vs. absent 5.6%; adjusted HR: 1.98, 95% CI: 1.09-3.60; P = 0.026) and lesions with a plaque burden of ≥70% (present 16.2% vs. absent 5.5%; adjusted HR: 2.90, 95% CI: 1.60-5.25; P < 0.001) were independently associated with a higher MACE rate. Thin-cap fibroatheroma lesions were also independently associated with the composite of death or ACS only (present 7.5% vs. absent 3.0%; adjusted HR: 2.51, 95% CI: 1.15-5.49; P = 0.021). Thin-cap fibroatheroma lesions with a plaque burden of ≥70% were associated with a higher MACE rate within (P = 0.011) and after (P < 0.001) 6 months of follow-up, while smaller TCFA lesions were only associated with a higher MACE rate after 6 months (P = 0.033). CONCLUSION In patients undergoing coronary angiography, the presence of IVUS virtual histology-derived TCFA lesions in a non-culprit coronary artery is strongly and independently predictive for the occurrence of MACE within 1 year, particularly of death and ACS. Thin-cap fibroatheroma lesions with a large plaque burden carry higher risk than small TCFA lesions, especially on the short term.

Collaboration


Dive into the Robert-Jan van Geuns's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Evelyn Regar

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yoshinobu Onuma

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Eric Boersma

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Felix Zijlstra

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Peter de Jaegere

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Roberto Diletti

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Ron T. van Domburg

Erasmus University Rotterdam

View shared research outputs
Researchain Logo
Decentralizing Knowledge