Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Robert Merwa is active.

Publication


Featured researches published by Robert Merwa.


Physiological Measurement | 2005

Solution of the inverse problem of magnetic induction tomography (MIT)

Robert Merwa; Karl Hollaus; Patricia Brunner; Hermann Scharfetter

Magnetic induction tomography (MIT) of biological tissue is used to reconstruct the changes in the complex conductivity distribution inside an object under investigation. The measurement principle is based on determining the perturbation DeltaB of a primary alternating magnetic field B0, which is coupled from an array of excitation coils to the object under investigation. The corresponding voltages DeltaV and V0 induced in a receiver coil carry the information about the passive electrical properties (i.e. conductivity, permittivity and permeability). The reconstruction of the conductivity distribution requires the solution of a 3D inverse eddy current problem. As in EIT the inverse problem is ill-posed and on this account some regularization scheme has to be applied. We developed an inverse solver based on the Gauss-Newton-one-step method for differential imaging, and we implemented and tested four different regularization schemes: the first and second approaches employ a classical smoothness criterion using the unit matrix and a differential matrix of first order as the regularization matrix. The third method is based on variance uniformization, and the fourth method is based on the truncated singular value decomposition. Reconstructions were carried out with synthetic measurement data generated with a spherical perturbation at different locations within a conducting cylinder. Data were generated on a different mesh and 1% random noise was added. The model contained 16 excitation coils and 32 receiver coils which could be combined pairwise to give 16 planar gradiometers. With 32 receiver coils all regularization methods yield fairly good 3D-images of the modelled changes of the conductivity distribution, and prove the feasibility of difference imaging with MIT. The reconstructed perturbations appear at the right location, and their size is in the expected range. With 16 planar gradiometers an additional spurious feature appears mirrored with respect to the median plane with negative sign. This demonstrates that a symmetrical arrangement with one ring of planar gradiometers cannot distinguish between a positive conductivity change at the true location and a negative conductivity change at the mirrored location.


Physiological Measurement | 2004

Detection of brain oedema using magnetic induction tomography: a feasibility study of the likely sensitivity and detectability

Robert Merwa; Karl Hollaus; Oszkar Biro; Hermann Scharfetter

The detection and continuous monitoring of brain oedema is of particular interest in clinical applications because existing methods (invasive measurement of the intracranial pressure) may cause considerable distress for the patients. A new non-invasive method for continuous monitoring of an oedema promises the use of multi-frequency magnetic induction tomography (MIT). MIT is an imaging method for reconstructing the changes of the conductivity deltakappa in a target object. The sensitivity of a single MIT-channel to a spherical oedematous region was analysed with a realistic model of the human brain. The model considers the cerebrospinal fluid around the brain, the grey matter, the white matter, the ventricle system and an oedema (spherical perturbation). Sensitivity maps were generated for different sizes and positions of the oedema when using a coaxial coil system. The maps show minimum sensitivity along the coil axis, and increasing values when moving the perturbation towards the brain surface. Parallel to the coil axis, however, the sensitivity does not vary significantly. When assuming a standard deviation of 10(-7) for the relative voltage change due to the systems noise, a centrally placed oedema with a conductivity contrast of 2 with respect to the background and a radius of 20 mm can be detected at 100 kHz. At higher frequencies the sensitivity increases considerably, thus suggesting the capability of multi-frequency MIT to detect cerebral oedema.


Physiological Measurement | 2003

Numerical solution of the general 3D eddy current problem for magnetic induction tomography (spectroscopy)

Robert Merwa; Karl Hollaus; Bernhard Brandstätter; Hermann Scharfetter

Magnetic induction tomography (MIT) is used for reconstructing the changes of the conductivity in a target object using alternating magnetic fields. Applications include, for example, the non-invasive monitoring of oedema in the human brain. A powerful software package has been developed which makes it possible to generate a finite element (FE) model of complex structures and to calculate the eddy currents in the object under investigation. To validate our software a model of a previously published experimental arrangement was generated. The model consists of a coaxial coil system and a conducting sphere which is moved perpendicular to the coil axis (a) in an empty space and (b) in a saline-filled cylindrical tank. The agreement of the measured and simulated data is very good when taking into consideration the systematic measurement errors in case (b). Thus the applicability of the simulation algorithm for two-compartment systems has been demonstrated even in the case of low conductivities and weak contrast. This can be considered an important step towards the solution of the inverse problem of MIT.


Physiological Measurement | 2005

A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT).

Hermann Scharfetter; Robert Merwa; Karl Pilz

Magnetic induction tomography (MIT) is a low-resolution imaging modality which aims at the three-dimensional (3D) reconstruction of the electrical conductivity in objects from alternating magnetic fields. In MIT systems the magnetic field perturbations to be detected are very small when compared to the excitation field (ppm range). The voltage which is induced by the excitation field in the receiver coils must be suppressed for providing sufficient dynamic range. In the past, two very efficient strategies were proposed: adjusted planar gradiometers (PGRAD) and the orientation of a receiver coil with respect to the excitation coil such that the net magnetic flow is zero (zero flow coil, ZFC). In contrast to the PGRAD no voltage is induced in the ZFC by the main field. This is advantageous because two comparatively high voltages in the two gradiometer coils can never be subtracted perfectly, thus leaving a residual voltage which is prone to drift. However, a disadvantage of the ZFC is the higher susceptibility to interferences from far RF sources. In contrast, in the gradiometer such interferences are cancelled to a high degree. We developed a new type of gradiometer (zero flow gradiometer, ZFGRAD) which combines the advantages of ZFC and PGRAD. All three systems were compared with respect to sensitivity and perturbation to signal ratio (PSR) defined as the ratio of the signal change due to a magnetic perturbation field at the carrier frequency and the signal change due to shifting a metallic sphere between two test points. The spatial sensitivity of the three systems was found to be very similar. The PSR of the ZFGRAD was more than 12 times lower than that of the ZFC. Finally, the feasibility of image reconstruction with two arrays of eight excitation coils and eight ZFGRAD, respectively, was shown with a single-step Gauss-Newton reconstructor and simulated measurement data generated for a cylindrical tank with a spherical perturbation. The resulting images show a clear, bright feature at the correct position of the sphere and are comparable to those with PGRAD arrays.


Physiological Measurement | 2006

A multifrequency magnetic induction tomography system using planar gradiometers: data collection and calibration

Javier Rosell-Ferrer; Robert Merwa; Patricia Brunner; Hermann Scharfetter

We developed a 14-channel multifrequency magnetic induction tomography system (MF-MIT) for biomedical applications. The excitation field is produced by a single coil and 14 planar gradiometers are used for signal detection. The object under measurement was rotated (16 steps per turn) to obtain a full data set for image reconstruction. We make measurements at frequencies from 50 kHz to 1 MHz using a single frequency excitation signal or a multifrequency signal containing several frequencies in this range. We used two acquisition boards giving a total of eight synchronous channels at a sample rate of 5 MS s(-1) per channel. The real and imaginary parts of DeltaB/B(0) were calculated using coherent demodulation at all injected frequencies. Calibration, averaging and drift cancellation techniques were used before image reconstruction. A plastic tank filled with saline (D = 19 cm) and with conductive and/or paramagnetic perturbations was measured for calibration and test purposes. We used a FEM model and an eddy current solver to evaluate the experimental results and to reconstruct the images. Measured equivalent input noise voltage for each channel was 2 nV Hz(-1/2). Using coherent demodulation, with an integration time of 20 ms, the measured STD for the magnitude was 7 nV(rms) (close to the theoretical value only taking into account the amplifiers thermal noise). For long acquisition times the drift in the signal produced a bigger effect than the input noise (typical STD was 10 nV with a maximum of 35 nV at one channel) but this effect was reduced using a drift cancellation technique based on averaging. We were able to image a 2 S m(-1) agar sphere (D = 4 cm) inside the tank filled with saline of 1 S m(-1).


Physiological Measurement | 2004

Fast calculation of the sensitivity matrix in magnetic induction tomography by tetrahedral edge finite elements and the reciprocity theorem

Karl Hollaus; Christian Magele; Robert Merwa; Hermann Scharfetter

Magnetic induction tomography of biological tissue is used to reconstruct the changes in the complex conductivity distribution by measuring the perturbation of an alternating primary magnetic field. To facilitate the sensitivity analysis and the solution of the inverse problem a fast calculation of the sensitivity matrix, i.e. the Jacobian matrix, which maps the changes of the conductivity distribution onto the changes of the voltage induced in a receiver coil, is needed. The use of finite differences to determine the entries of the sensitivity matrix does not represent a feasible solution because of the high computational costs of the basic eddy current problem. Therefore, the reciprocity theorem was exploited. The basic eddy current problem was simulated by the finite element method using symmetric tetrahedral edge elements of second order. To test the method various simulations were carried out and discussed.


IEEE Transactions on Magnetics | 2004

Numerical simulation of the eddy current problem in magnetic induction tomography for biomedical applications by edge elements

Karl Hollaus; Christian Magele; Robert Merwa; Hermann Scharfetter

Magnetic induction tomography of biological tissue is used for reconstructing the conductivity distribution /spl kappa/=/spl sigma/+j/spl omega//spl epsiv/ or changes /spl Delta//spl kappa/ in a human body by measuring the perturbation /spl Delta/B of an alternating magnetic field B/sub 0/. The aim is to simulate the eddy current problem in magnetic induction tomography for biomedical applications by symmetric tetrahedral edge finite elements of second order. The method is validated by measurement data from a representative experiment, and numerical results of an edema in a human head are presented.


Physiological Measurement | 2006

Reconstruction of the shape of conductivity spectra using differential multi-frequency magnetic induction tomography

Patricia Brunner; Robert Merwa; Andreas Missner; Javier Rosell; Karl Hollaus; Hermann Scharfetter

Magnetic induction tomography (MIT) of biological tissue is used for the reconstruction of the complex conductivity distribution kappa inside the object under investigation. It is based on the perturbation of an alternating magnetic field caused by the object and can be used in all applications of electrical impedance tomography (EIT) such as functional lung monitoring and assessment of tissue fluids. In contrast to EIT, MIT does not require electrodes and magnetic fields can also penetrate non-conducting barriers such as the skull. As in EIT, the reconstruction of absolute conductivity values is very difficult because of the methods sensitivity to numerical errors and noise. To overcome this problem, image reconstruction in EIT is often done differentially. Analogously, this concept has been adopted for MIT. Two different methods for differential imaging are applicable. The first one is state-differential, for example when the conductivity change between inspiration and expiration in the lung regions is being detected. The second one is frequency-differential, which is of high interest in motionless organs like the brain, where a state-differential method cannot be applied. An equation for frequency-differential MIT was derived taking into consideration the frequency dependence of the sensitivity matrix. This formula is valid if we can assume that only small conductivity changes occur. In this way, the non-linear inverse problem of MIT can be approximated by a linear one (depending only on the frequency), similar to in EIT. Keeping this limitation in mind, the conductivity changes between one or more reference frequencies and several measurement frequencies were reconstructed, yielding normalized conductivity spectra. Due to the differential character of the method, these spectra do not provide absolute conductivities but preserve the shape of the spectrum. The validity of the method was tested with artificial data generated with a spherical perturbation within a conducting cylinder as well as for real measurement data. The measurement data were obtained from a potato immersed in saline. The resulting spectra were compared with reference measurements and the preservation of the shape of the spectra was analyzed.


Physiological Measurement | 2003

Direct estimation of Cole parameters in multifrequency EIT using a regularized Gauss–Newton method

Bernhard Brandstätter; Karl Hollaus; Helmut Hutten; Michael Mayer; Robert Merwa; Hermann Scharfetter

A major drawback of electrical impedance tomography is the poor quality of the conductivity images, i.e., the low spatial resolution as well as large errors in the reconstructed conductivity values. The main reason is the necessity for regularization of the ill-conditioned inverse problem which results in excessive spatial low-pass filtering. A novel regularization method (SMORR (spectral modelling regularized reconstructor)) is proposed, which is based on the inclusion of spectral a priori information in the form of appropriate tissue models (e.g. Cole models). This approach reduces the ill-posedness of the inverse problem, when multifrequency data are available. An additional advantage is the direct reconstruction of the (physiological) tissue parameters of interest instead of the conductivities. SMORR was compared with posterior fitting of a Cole model to the conductivity spectra obtained with a classical iterative reconstruction scheme at various frequencies. SMORR performed significantly better than the reference method concerning robustness against noise in the data.


Physiological Measurement | 2007

Magnetic induction tomography: evaluation of the point spread function and analysis of resolution and image distortion

Robert Merwa; Hermann Scharfetter

Magnetic induction tomography (MIT) is a low-resolution imaging modality used for reconstructing the changes of the passive electrical properties in a target object. For an imaging system, it is very important to give forecasts about the image quality. Both the maximum resolution and the correctness of the location of the inhomogeneities are of major interest. Furthermore, the smallest object which can be detected for a certain noise level is a criterion for the diagnostic value of an image. The properties of an MIT image are dependent on the position inside the object, the conductivity distribution and of course on the location and the number of excitation coils and receiving coils. Quantitative statements cannot be made in general but it is feasible to predict the image quality for a selected problem. For electrical impedance tomography (EIT), the theoretical limits of image quality have been studied carefully and a comprehensive analysis for MIT is necessary. Thus, a simplified analysis on resolution, dimensions and location of an inhomogeneity was carried out by means of an evaluation of the point spread function (PSF). In analogy to EIT the PSF depends strongly on the location, showing the broadest distribution in the centre of the object. Increasing the amount of regularization according to increasing measurement noise, the PSF broadens and its centre is shifted towards the borders of the object. The resolution is indirectly proportional to the width of the PSF and increases when moving from the centre towards the border of the object and decreases with increasing noise.

Collaboration


Dive into the Robert Merwa's collaboration.

Top Co-Authors

Avatar

Hermann Scharfetter

Graz University of Technology

View shared research outputs
Top Co-Authors

Avatar

Karl Hollaus

Graz University of Technology

View shared research outputs
Top Co-Authors

Avatar

Patricia Brunner

Graz University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Michael Mayer

Graz University of Technology

View shared research outputs
Top Co-Authors

Avatar

Javier Rosell

Polytechnic University of Catalonia

View shared research outputs
Top Co-Authors

Avatar

Andreas Missner

Graz University of Technology

View shared research outputs
Top Co-Authors

Avatar

Christian Magele

Graz University of Technology

View shared research outputs
Top Co-Authors

Avatar

Oszkar Biro

Graz University of Technology

View shared research outputs
Top Co-Authors

Avatar

Javier Rosell-Ferrer

Polytechnic University of Catalonia

View shared research outputs
Researchain Logo
Decentralizing Knowledge