Rolf Stämpfli
Swiss Federal Laboratories for Materials Science and Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Rolf Stämpfli.
Biomaterials | 2011
Lutz-Christian Gerhardt; Kate Widdows; M. Erol; Charles W. Burch; J.A. Sanz-Herrera; Ignacio Ochoa; Rolf Stämpfli; Iman S. Roqan; S.M. Gabe; Tahera Ansari; Aldo R. Boccaccini
The angiogenic properties of micron-sized (m-BG) and nano-sized (n-BG) bioactive glass (BG) filled poly(D,L lactide) (PDLLA) composites were investigated. On the basis of cell culture work investigating the secretion of vascular endothelial growth factor (VEGF) by human fibroblasts in contact with composite films (0, 5, 10, 20 wt %), porous 3D composite scaffolds, optimised with respect to the BG filler content capable of inducing angiogenic response, were produced. The in vivo vascularisation of the scaffolds was studied in a rat animal model and quantified using stereological analyses. The prepared scaffolds had high porosities (81-93%), permeability (k = 5.4-8.6 x 10⁻⁹ m²) and compressive strength values (0.4-1.6 MPa) all in the range of trabecular bone. On composite films containing 20 wt % m-BG or n-BG, human fibroblasts produced 5 times higher VEGF than on pure PDLLA films. After 8 weeks of implantation, m-BG and n-BG containing scaffolds were well-infiltrated with newly formed tissue and demonstrated higher vascularisation and percentage blood vessel to tissue (11.6-15.1%) than PDLLA scaffolds (8.5%). This work thus shows potential for the regeneration of hard-soft tissue defects and increased bone formation arising from enhanced vascularisation of the construct.
Textile Research Journal | 2011
René M. Rossi; Rolf Stämpfli; Agnes Psikuta; Ivo Rechsteiner; Paul A. Brühwiler
The moisture transfer and absorption properties of fabrics play an important role in the evaluation of the overall wear comfort of the textile. The location of moisture in the textile influences the skin wetness as well as the skin/textile friction process. In this study, we used X-ray tomography to analyze the transplanar and in-plane water transport in different sock materials when two defined pressures were applied to the inner side by means of an adjustable screw. The materials used were polyamide, polypropylene and wool, and had very distinct hydrophilic/hydrophobic and hygroscopic properties. The in-plane wicking effect showed a clear time dependency for the polyamide and wool samples, while the spreading of the polypropylene samples was very scattered. This effect was generally larger in the outer side of the sock than in the inner side, showing a clear tendency of these socks to wick the moisture away from the skin. Applying a pressure generally increased the in-plane water transport, but it affected the water distribution throughout the thickness of the sock for the wool samples, as more water remained in the inner half. The transplanar wicking effect was the most efficient with the polypropylene sock under the high pressure condition, but with the low pressure, this sock was not able to absorb all the moisture and a small quantity of water remained at its inner surface. X-ray tomography was shown to be a powerful tool to analyze not only the water distribution in static conditions, but also the transient 3-dimensional water transport.
British Journal of Sports Medicine | 2010
Kai-Uwe Schmitt; Bendicht Liechti; Frank I. Michel; Rolf Stämpfli; Paul A. Brühwiler
Objective Back protectors for snowboarders were analysed with respect to their potential to prevent spinal injury. Design In 20 Swiss skiing resorts, athletes were interviewed on the slope. In addition, an online survey was conducted. The performance of 12 commercially available back protectors was investigated by means of mechanical testing. A currently used drop test according to standard EN1621 (motorcycle protectors), testing energy damping was supplemented by penetration tests according to standard EN1077, which reflects snowsport safety concerns. Results 6 out of 12 back protectors fulfilled the higher safety level defined in EN1621. Protectors making use of energy-absorbing layers performed particularly well. In contrast, hard shell protectors exhibited a higher potential to withstand the penetration test. The surveys confirmed that approximately 40–50% of snowboarders use a back protector. A large majority of users expect protection from severe spinal injury such as vertebral fractures or spinal cord injury. Conclusions The currently used test standards are fulfilled by many back protectors. Users, however, expect protectors to be efficient in impact scenarios that result in spinal injury, which are more severe than impacts as addressed in the current standards. This study highlights that there is a mismatch between the capabilities of current back protectors to prevent spinal injury in snowboarding and the expectations users have of these protectors.
International Journal of Occupational Safety and Ergonomics | 2008
René M. Rossi; Walter Bolli; Rolf Stämpfli
Heat and mechanical protection properties of 6 fabric combinations commonly used in firefighters’ protective clothing were assessed before and after different heat treatment. It was shown that after heat exposure, the values obtained were generally lower than in the original state. The mechanical properties of the materials were more affected by heat than by heat protective properties. In 2 cases, degradation started before a visible change in the material could be observed, which might be potentially dangerous for the end user who will not realize the alteration of the material.
PLOS ONE | 2015
Patrick D. Wettenschwiler; Silvio Lorenzetti; Rolf Stämpfli; René M. Rossi; Stephen J. Ferguson; Simon Annaheim
Discomfort during load carriage is a major issue for activities using backpacks (e.g. infantry maneuvers, children carrying school supplies, or outdoor sports). It is currently unclear which mechanical parameters are responsible for subjectively perceived discomfort. The aim of this study was to identify objectively measured mechanical predictors of discomfort during load carriage. We compared twelve different configurations of a typical load carriage system, a commercially available backpack with a hip belt. The pressure distribution under the hip belt and the shoulder strap, as well as the tensile force in the strap and the relative motion of the backpack were measured. Multiple linear regression analyses were conducted to investigate possible predictors of discomfort. The results demonstrate that static peak pressure, or alternatively, static strap force is a significant (p<0.001) predictor of discomfort during load carriage in the shoulder and hip region, accounting for 85% or more of the variation in discomfort. As an additional finding, we discovered that the regression coefficients of these predictors are significantly smaller for the hip than for the shoulder region. As static peak pressure is measured directly on the body, it is less dependent on the type of load carriage system than static strap force. Therefore, static peak pressure is well suited as a generally applicable, objective mechanical parameter for the optimization of load carriage system design. Alternatively, when limited to load carriage systems of the type backpack with hip belt, static strap force is the most valuable predictor of discomfort. The regionally differing regression coefficients of both predictors imply that the hip region is significantly more tolerant than the shoulder region. In order to minimize discomfort, users should be encouraged to shift load from the shoulders to the hip region wherever possible, at the same time likely decreasing the risk of low back pain or injury.
Measurement Science and Technology | 2009
Rolf Stämpfli; Paul A. Brühwiler
A drop test system with flexibility in the choice of falling object has been constructed and characterized. Using the guided free fall principle, the system enables the study of impacts of a large range of objects on a wide selection of anvils, with high control of the position and orientation of the object. The latter is demonstrated with falls of a standard aluminium headform in mountaineering helmets on a kerbstone anvil, for which visual inspection with a high-speed camera confirms the desired accuracy. Impacts of a flat falling body on cylindrical polystyrene foam samples are used to derive stress–strain curves for materials of different density and for multilayer samples. In this case, the effects of striker orientation and placement on the resultant data are discussed, and the reproducibility of the data serves as an additional confirmation of the accuracy of the measurement apparatus and procedures. A check on the improvement in the level of positional and orientational striking precision achievable is obtained via an inter-laboratory comparison.
PLOS ONE | 2017
Patrick D. Wettenschwiler; Simon Annaheim; Silvio Lorenzetti; Stephen J. Ferguson; Rolf Stämpfli; Agnes Psikuta; René M. Rossi
Due to the increasing load in backpacks and other load carriage systems over the last decades, load carriage system designs have to be adapted accordingly to minimize discomfort and to reduce the risk of injury. As subject studies are labor-intensive and include further challenges such as intra-subject and inter-subject variability, we aimed to validate an instrumented dummy as an objective laboratory tool to assess the mechanical aspects of discomfort. The validation of the instrumented dummy was conducted by comparison with a recent subject study. The mechanical parameters that characterize the static and dynamic interaction between backpack and body during different backpack settings were compared. The second aim was to investigate whether high predictive power (coefficient of determination R2>0.5) in assessing the discomfort of load carriage systems could be reached using the instrumented dummy. Measurements were conducted under static conditions, simulating upright standing, and dynamic conditions, simulating level walking. Twelve different configurations of a typical load carriage system, a commercially available backpack with a hip belt, were assessed. The mechanical parameters were measured in the shoulder and the hip region of the dummy and consisted of average pressure, peak pressure, strap force and relative motion between the system and the body. The twelve configurations consisted of three different weights (15kg, 20kg, and 25kg), combined with four different hip belt tensions (30N, 60N, 90N, and 120N). Through the significant (p<0.05) correlation of the mechanical parameters measured on the dummy with the corresponding values of the subject study, the dummy was validated for all static measurements and for dynamic measurements in the hip region to accurately simulate the interaction between the human body and the load carriage system. Multiple linear regressions with the mechanical parameters measured on the dummy as independent variables and the corresponding subjective discomfort scores from the subject study as the dependent variable revealed a high predictive power of the instrumented dummy. The dummy can explain 75% or more of the variance in discomfort using average pressures as predictors and even 79% or more of the variance in discomfort using strap forces as predictors. Use of the dummy enables objective, fast, and iterative assessments of load carriage systems and therefore reduces the need for labor-intensive subject studies in order to decrease the mechanical aspects of discomfort during load carriage.
Computer Methods in Biomechanics and Biomedical Engineering | 2017
Patrick D. Wettenschwiler; Silvio Lorenzetti; Stephen J. Ferguson; Rolf Stämpfli; Ameet Aiyangar; René M. Rossi; Simon Annaheim
Abstract Backpack carriage is significantly associated with a higher prevalence of low back pain. Elevated compression and shear forces in the lumbar intervertebral discs are known risk factors. A novel method of calculating the loads in the lumbar spine during backpack carriage is presented by combining physical and numerical modelling. The results revealed that to predict realistic lumbar compression forces, subject-specific lumbar curvature data were not necessary for loads up to 40 kg. In contrast, regarding shear forces, using subject-specific lumbar curvature data from upright MRI measurements as input for the rigid body model significantly altered lumbar joint force estimates.
Journal of the American Ceramic Society | 2008
Jörg Petrasch; Peter Wyss; Rolf Stämpfli; Aldo Steinfeld
Applied Ergonomics | 2005
Paul A. Brühwiler; Rolf Stämpfli; R. Huber; M. Camenzind
Collaboration
Dive into the Rolf Stämpfli's collaboration.
Swiss Federal Laboratories for Materials Science and Technology
View shared research outputsSwiss Federal Laboratories for Materials Science and Technology
View shared research outputsSwiss Federal Laboratories for Materials Science and Technology
View shared research outputsSwiss Federal Laboratories for Materials Science and Technology
View shared research outputsSwiss Federal Laboratories for Materials Science and Technology
View shared research outputs