Artificial Organs | 2009

Improvement of Hemocompatibility in Centrifugal Blood Pump With Hydrodynamic Bearings and Semi-open Impeller: In Vitro Evaluation

Ryo Kosaka; Osamu Maruyama; Masahiro Nishida; Toru Yada; Sakae Saito; Shusaku Hirai; Takashi Yamane

We have developed a noncontact-type centrifugal blood pump with hydrodynamic bearings and a semi-open impeller for mechanical circulatory assist. The impeller is levitated by an original spiral-groove thrust bearing and a herringbone-groove journal bearing, without any additional displacement-sensing module or additional complex control circuits. The pump was improved by optimizing the groove direction of the spiral-groove thrust bearing and the pull-up magnetic force between the rotor magnet and the stator coil against the impeller. To evaluate hemocompatibility, we conducted a levitation performance test and in vitro hemocompatibility tests by means of a mock-up circulation loop. In the hemolysis test, the normalized index of hemolysis was reduced from 0.721 to 0.0335 g/100 L corresponding to an expansion of the bearing gap from 1.1 to 56.1 microm. In the in vitro antithrombogenic test, blood pumps with a wide thrust bearing gap were effective in preventing thrombus formation. Through in vitro evaluation tests, we confirmed that hemocompatibility was improved by balancing the hydrodynamic fluid dynamics and magnetic forces.


Artificial Organs | 2009

Hemocompatibility Evaluation With Experimental and Computational Fluid Dynamic Analyses for a Monopivot Circulatory Assist Pump

Masahiro Nishida; Osamu Maruyama; Ryo Kosaka; Takashi Yamane; Hisato Kogure; Hiroshi Kawamura; Yoshihiro Yamamoto; Katsuyuki Kuwana; Yoshiyuki Sankai; Tatsuo Tsutsui

The hemocompatibility of a newly developed monopivot circulatory assist pump was evaluated by the computational fluid dynamic (CFD) analyses with the particle tracking velocimetry measurement. Results were compared with those of the hemolysis test and in vitro antithrombogenic test to prevent hemolysis and thrombus formation inside the pump. The results of the CFD analysis and the particle tracking velocimetry had a good agreement with each other. The flow distributions by the CFD analysis indicated that the radial jet out of the impeller was adequately weak so that the wall shear stress was lower than 300 Pa on the volute casing wall. It corresponded with the hemolysis tests results, indicating that the hemolysis level was lower than that of the commercially available pump. However, the flow distributions also indicated that the pivot that was easy to stagnate was washed out, not only by the secondary flow through the back gap of the impeller, but also by the vortices generated by the secondary vanes. It corresponded with the in vitro antithrombogenic test results, indicating that thrombus formation could be removed only by redesigning the geometry of the secondary vanes.


Journal of Artificial Organs | 2007

Hemocompatibility of a hydrodynamic levitation centrifugal blood pump

Takashi Yamane; Osamu Maruyama; Masahiro Nishida; Ryo Kosaka; Daisuke Sugiyama; Yusuke Miyamoto; Hiroshi Kawamura; Takahisa Kato; Takeshi Sano; Takeshi Okubo; Yoshiyuki Sankai; Osamu Shigeta; Tatsuo Tsutsui

A noncontact type centrifugal pump without any complicated control or sensing modules has been developed as a long-term implantable artificial heart. Centrifugal pumps with impellers levitated by original hydrodynamic bearings were designed and have been modified through numerical analyses and in vitro tests. The hemolysis level was reduced by changing the pressure distribution around the impeller and subsequently expanding the bearing gap. Thrombus formation in the bearing was examined with in vitro thrombogenesis tests and was reduced by changing the groove shapes to increase the bearing-gap flow to 3% of the external flow. Unnecessary vortices around the vanes were also eliminated by changing the number of vanes from four to six.


Artificial Organs | 2014

Feasibility of the Optical Imaging of Thrombus Formation in a Rotary Blood Pump by Near‐Infrared Light

Daisuke Sakota; Tomotaka Murashige; Ryo Kosaka; Masahiro Nishida; Osamu Maruyama

Blood coagulation is one of the primary concerns when using mechanical circulatory support devices such as blood pumps. Noninvasive detection and imaging of thrombus formation is useful not only for the development of more hemocompatible devices but also for the management of blood coagulation to avoid risk of infarction. The objective of this study is to investigate the use of near-infrared light for imaging of thrombus formation in a rotary blood pump. The optical properties of a thrombus at wavelengths ranging from 600 to 750 nm were analyzed using a hyperspectral imaging (HSI) system. A specially designed hydrodynamically levitated centrifugal blood pump with a visible bottom area was used. In vitro antithrombogenic testing was conducted five times with the pump using bovine whole blood in which the activated blood clotting time was adjusted to 200 s prior to the experiment. Two halogen lights were used for the light sources. The forward scattering through the pump and backward scattering on the pump bottom area were imaged using the HSI system. HSI showed an increase in forward scattering at wavelengths ranging from 670 to 750 nm in the location of thrombus formation. The time at which the thrombus began to form in the impeller rotating at 2780 rpm could be detected. The spectral difference between the whole blood and the thrombus was utilized to image thrombus formation. The results indicate the feasibility of dynamically detecting and imaging thrombus formation in a rotary blood pump.


Artificial Organs | 2013

Optimal design of the hydrodynamic multi-arc bearing in a centrifugal blood pump for the improvement of bearing stiffness and hemolysis level.

Kazuya Yasui; Ryo Kosaka; Masahiro Nishida; Osamu Maruyama; Yasuo Kawaguchi; Takashi Yamane

The purpose of the present study is to establish an optimal design of the multi-arc hydrodynamic bearing in a centrifugal blood pump for the improvement of bearing stiffness and hemolysis level. The multi-arc bearing was designed to fulfill the required specifications: (i) ensuring the uniform bearing stiffness for various bearing angles; (ii) ensuring a higher bearing stiffness than the centrifugal force to prevent impeller whirl; and (iii) adjusting the bearing clearance as much as possible to reduce hemolysis. First, a numerical analysis was performed to optimize three design parameters of the multi-arc bearing: number of arcs N, bearing clearance C, and groove depth H. To validate the accuracy of the numerical analysis, the impeller trajectories for six pump models were measured. Finally, an in vitro hemolysis test was conducted to evaluate the hemolytic property of the multi-arc bearing. As a result of the numerical analysis, the optimal parameter combination was determined as follows: N=4, C=100 μm, and H ≥ 100 μm. In the measurements of the impeller trajectory, the optimal parameter combination was found to be as follows: N=4, C=90 μm, and H=100 μm. This result demonstrated the high reliability of the numerical analysis. In the hemolysis test, the parameter combination that achieved the smallest hemolysis was obtained as follows: N=4, C=90 μm, and H=100 μm. In conclusion, the multi-arc bearing could be optimized for the improvement of bearing stiffness and hemolysis level.


Artificial Organs | 2013

Geometric Optimization of a Step Bearing for a Hydrodynamically Levitated Centrifugal Blood Pump for the Reduction of Hemolysis

Ryo Kosaka; Toru Yada; Masahiro Nishida; Osamu Maruyama; Takashi Yamane

A hydrodynamically levitated centrifugal blood pump with a semi-open impeller has been developed for mechanical circulatory assistance. However, a narrow bearing gap has the potential to cause hemolysis. The purpose of the present study is to optimize the geometric configuration of the hydrodynamic step bearing in order to reduce hemolysis by expansion of the bearing gap. First, a numerical analysis of the step bearing, based on lubrication theory, was performed to determine the optimal design. Second, in order to assess the accuracy of the numerical analysis, the hydrodynamic forces calculated in the numerical analysis were compared with those obtained in an actual measurement test using impellers having step lengths of 0%, 33%, and 67% of the vane length. Finally, a bearing gap measurement test and a hemolysis test were performed. As a result, the numerical analysis revealed that the hydrodynamic force was the largest when the step length was approximately 70%. The hydrodynamic force calculated in the numerical analysis was approximately equivalent to that obtained in the measurement test. In the measurement test and the hemolysis test, the blood pump having a step length of 67% achieved the maximum bearing gap and reduced hemolysis, as compared with the pumps having step lengths of 0% and 33%. It was confirmed that the numerical analysis of the step bearing was effective, and the developed blood pump having a step length of approximately 70% was found to be a suitable configuration for the reduction of hemolysis.


Artificial Organs | 2013

Enhancement of Hemocompatibility of the MERA Monopivot Centrifugal Pump: Toward Medium-Term Use

Takashi Yamane; Ryo Kosaka; Masahiro Nishida; Osamu Maruyama; Yoshihiro Yamamoto; Katsuyuki Kuwana; Hiroshi Kawamura; Yasuyuki Shiraishi; Tomoyuki Yambe; Yoshiyuki Sankai; Tatsuo Tsutsui

The MERA monopivot centrifugal pump has been developed for use in open-heart surgery, circulatory support, and bridge-to-decision for up to 4 weeks. The pump has a closed-type, 50-mm diameter impeller with four straight paths. The impeller is supported by a monopivot bearing and is driven by a radial-flux magnet-coupling motor. Because flow visualization experiments have clarified sufficient pivot wash and stagnation at the sharp corner of the pivot support was suggested, sharp corners were removed in the design stage. The index of hemolysis of the pump operating at more than 200 mm Hg was found to be lower than that of a commercial pump. Four-week animal tests were then conducted two times; improvement of thrombus formation was seen in the female pivot through modification of female pivot geometry. Overall antithrombogenicity was also recorded. Finally, to assure mid-term use, an additional 4-week durability test revealed that the rate of the axial pivot wear was as small as 1.1 µm/day. The present in vitro and in vivo studies revealed that the MERA monopivot centrifugal pump has sufficient hemocompatibility and durability for up to 4 weeks.


Artificial Organs | 2014

Optimal Bearing Gap of a Multiarc Radial Bearing in a Hydrodynamically Levitated Centrifugal Blood Pump for the Reduction of Hemolysis

Ryo Kosaka; Kazuya Yasui; Masahiro Nishida; Yasuo Kawaguchi; Osamu Maruyama; Takashi Yamane

We have developed a hydrodynamically levitated centrifugal pump as a bridge-to-decision device. The purpose of the present study is to determine the optimal bearing gap of a multiarc radial bearing in the developed blood pump for the reduction of hemolysis. We prepared eight pump models having bearing gaps of 20, 30, 40, 80, 90, 100, 180, and 250 μm. The driving conditions were set to a pressure head of 200 mm Hg and a flow rate of 4 L/min. First, the orbital radius of the impeller was measured for the evaluation of the impeller stability. Second, the hemolytic property was evaluated in an in vitro hemolysis test. As a result, the orbital radius was not greater than 15 μm when the bearing gap was between 20 and 100 μm. The relative normalized index of hemolysis (NIH) ratios in comparison with BPX-80 were 37.67 (gap: 20 μm), 0.95 (gap: 30 μm), 0.96 (gap: 40 μm), 0.82 (gap: 80 μm), 0.77 (gap: 90 μm), 0.92 (gap: 100 μm), 2.76 (gap: 180 μm), and 2.78 (gap: 250 μm). The hemolysis tended to increase at bearing gaps of greater than 100 μm due to impeller instability. When the bearing gap decreased from 30 to 20 μm, the relative NIH ratios increased significantly from 0.95 to 37.67 times (P < 0.01) due to high shear stress. We confirmed that the optimal bearing gap was determined between 30 and 100 μm in the developed blood pump for the reduction of hemolysis.


Artificial Organs | 2016

Effect of Impeller Geometry on Lift‐Off Characteristics and Rotational Attitude in a Monopivot Centrifugal Blood Pump

Masahiro Nishida; Kento Nakayama; Daisuke Sakota; Ryo Kosaka; Osamu Maruyama; Yasuo Kawaguchi; Katsuyuki Kuwana; Takashi Yamane

The effect of the flow path geometry of the impeller on the lift-off and tilt of the rotational axis of the impeller against the hydrodynamic force was investigated in a centrifugal blood pump with an impeller supported by a single-contact pivot bearing. Four types of impeller were compared: the FR model with the flow path having both front and rear cutouts on the tip, the F model with the flow path having only a front cutout, the R model with only a rear cutout, and the N model with a straight flow path. First, the axial thrust and the movement about the pivot point, which was loaded on the surface of the impeller, were calculated using computational fluid dynamics (CFD) analysis. Next, the lift-off point and the tilt of the rotational axis of the impeller were measured experimentally. The CFD analysis showed that the axial thrust increased gently in the FR and R models as the flow rate increased, whereas it increased drastically in the F and N models. This difference in axial thrust was likely from the higher pressure caused by the smaller circumferential velocity in the gap between the top surface of the impeller and the casing in the FR and R models than in the F and N models, which was caused by the rear cutout. These results corresponded with the experimental results showing that the impellers lifted off in the F and N models as the flow rate increased, whereas it did not in the FR and R models. Conversely, the movement about the pivot point increased in the direction opposite the side with the pump outlet as the flow rate increased. However, the tilt of the rotational axis of the impeller, which oriented away from the pump outlet, was less than 0.8° in any model under any conditions, and was considered to negligibly affect the rotational attitude of the impeller. These results confirm that a rear cutout prevents lift-off of the impeller caused by a decrease in the axial thrust.


Artificial Organs | 2015

Real-Time Observation of Thrombus Growth Process in an Impeller of a Hydrodynamically Levitated Centrifugal Blood Pump by Near-Infrared Hyperspectral Imaging

Daisuke Sakota; Tomotaka Murashige; Ryo Kosaka; Tatsuki Fujiwara; Masahiro Nishida; Osamu Maruyama

Understanding the thrombus formation in cardiovascular devices such as rotary blood pumps is the most important issue in developing more hemocompatible devices. The objective of this study was to develop a hyperspectral imaging (HSI) method to visualize the thrombus growth process within a rotary blood pump and investigate the optical properties of the thrombus. An in vitro thrombogenic test was conducted using fresh porcine blood and a specially designed hydrodynamically levitated centrifugal blood pump with a transparent bottom. The pump rotating at 3000 rpm circulated the blood at 1.0 L/min. The bottom surface of the pump was illuminated with white light pulsed at the same frequency as the pump rotation, and the backward-scattered light was imaged using the HSI system. Using stroboscopic HSI and an image construction algorithm, dynamic spectral imaging at wavelengths ranging from 608 to 752 nm within the rotating pump was achieved. After completing the experiment, we collected the red thrombus formed in the pump impeller and quantified the thrombus hemoglobin concentration (Hbthrombus ). The spectrum changed around the center of the impeller, and the area of change expanded toward the impeller flow path. The shape corresponded approximately to the shape of the thrombus. The spectrum change indicated that the light scattering derived from red blood cells decreased. The Hbthrombus was 4.7 ± 1.3 g/dL versus a total hemoglobin of 13 ± 0.87 g/dL. The study revealed that Hbthrombus was reduced by the surrounding blood flow.

Collaboration


Dive into the Ryo Kosaka's collaboration.

Top Co-Authors

Avatar

Osamu Maruyama

National Institute of Advanced Industrial Science and Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Masahiro Nishida

Nagoya Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yasuo Kawaguchi

Tokyo University of Science

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Tomotaka Murashige

Tokyo University of Science

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge