Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where S. Chelkowski is active.

Publication


Featured researches published by S. Chelkowski.


Physical Review Letters | 2008

Observation of squeezed light with 10-dB quantum-noise reduction.

H. Vahlbruch; M. Mehmet; N. Lastzka; B. Hage; S. Chelkowski; A. Franzen; S. Gossler; Karsten Danzmann; Roman Schnabel

Squeezing of lights quantum noise requires temporal rearranging of photons. This again corresponds to creation of quantum correlations between individual photons. Squeezed light is a nonclassical manifestation of light with great potential in high-precision quantum measurements, for example, in the detection of gravitational waves [C. M. Caves, Phys. Rev. D 23, 1693 (1981)10.1103/PhysRevD.23.1693]. Equally promising applications have been proposed in quantum communication [H. P. Yuen and J. H. Shapiro, IEEE Trans. Inf. Theory 24, 657 (1978)10.1109/TIT.1978.1055958]. However, after 20 years of intensive research doubts arose whether strong squeezing can ever be realized as required for eminent applications. Here we show experimentally that strong squeezing of lights quantum noise is possible. We reached a benchmark squeezing factor of 10 in power (10 dB). Thorough analysis reveals that even higher squeezing factors will be feasible in our setup.


Physical Review Letters | 2006

Coherent control of vacuum squeezing in the gravitational-wave detection band

H. Vahlbruch; S. Chelkowski; B. Hage; A. Franzen; Karsten Danzmann; Roman Schnabel

We propose and demonstrate a coherent control scheme for stable phase locking of squeezed vacuum fields. We focus on sideband fields at frequencies from 10 Hz to 10 kHz, which is a frequency regime of particular interest in gravitational-wave detection and for which conventional control schemes have failed so far. A vacuum field with broadband squeezing covering this entire band was produced using optical parametric oscillation and characterized with balanced homodyne detection. The system was stably controlled over long periods utilizing two coherent but frequency shifted control fields. In order to demonstrate the performance of our setup the squeezed field was used for a nonclassical sensitivity improvement of a Michelson interferometer at audio frequencies.


Classical and Quantum Gravity | 2010

A Xylophone Configuration for a third Generation Gravitational Wave Detector

S. Hild; S. Chelkowski; Andreas Freise; J. Franc; N. Morgado; R. Flaminio; R. DeSalvo

Achieving the demanding sensitivity and bandwidth, envisaged for third-generation gravitational wave (GW) observatories, is extremely challenging with a single broadband interferometer. Very high optical powers (megawatts) are required to reduce the quantum noise contribution at high frequencies, while the interferometer mirrors have to be cooled to cryogenic temperatures in order to reduce thermal noise sources at low frequencies. To resolve this potential conflict of cryogenic test masses with high thermal load, we present a conceptual design for a 2-band xylophone configuration for a third-generation GW observatory, composed of a high-power, high-frequency interferometer and a cryogenic low-power, low-frequency instrument. Featuring inspiral ranges of 3200 Mpc and 38 000 Mpc for binary neutron stars and binary black holes coalesences, respectively, we find that the potential sensitivity of xylophone configurations can be significantly wider and better than what is possible in a single broadband interferometer.


Classical and Quantum Gravity | 2006

Status of the GEO600 detector

H. Lück; M. Hewitson; P. Ajith; B. Allen; P. Aufmuth; C. Aulbert; S. Babak; R. Balasubramanian; B. Barr; Steven J. Berukoff; Alexander Bunkowski; G. Cagnoli; C. A. Cantley; M. M. Casey; S. Chelkowski; Y. Chen; D. Churches; T. Cokelaer; C. N. Colacino; D. R. M. Crooks; Curt Cutler; Karsten Danzmann; R. J. Dupuis; E. J. Elliffe; Carsten Fallnich; A. Franzen; A. Freise; I. Gholami; S. Goßler; A. Grant

Of all the large interferometric gravitational-wave detectors, the German/British project GEO600 is the only one which uses dual recycling. During the four weeks of the international S4 data-taking run it reached an instrumental duty cycle of 97% with a peak sensitivity of 7 × 10−22 Hz−1/2 at 1 kHz. This paper describes the status during S4 and improvements thereafter.


Physical Review Letters | 2005

Demonstration of a squeezed light enhanced power- and signal-recycled Michelson interferometer

H. Vahlbruch; S. Chelkowski; B. Hage; A. Franzen; Karsten Danzmann; Roman Schnabel

We report on the experimental combination of three advanced interferometer techniques for gravitational wave detection, namely, power recycling, detuned signal recycling, and squeezed field injection. For the first time, we experimentally prove the compatibility of especially the latter two. To achieve a broadband nonclassical sensitivity improvement, we applied a filter cavity for compensation of quadrature rotation. The signal-to-noise ratio was improved by up to 2.8 dB beyond the coherent states shot noise. The complete setup was stably locked for arbitrary times and characterized by injected single-sideband modulation fields.


Physical Review D | 2003

Squeezed-input, optical-spring, signal-recycled gravitational-wave detectors

J. Harms; Yanbei Chen; S. Chelkowski; A. Franzen; H. Vahlbruch; Karsten Danzmann; Roman Schnabel

We theoretically analyze the quantum noise of signal-recycled laser interferometric gravitational-wave detectors with additional input and output optics, namely frequency-dependent squeezing of the vacuum entering the dark port and frequency-dependent homodyne detection. We combine the work of Buonanno and Chen on the quantum noise of signal-recycled interferometers with ordinary input-output optics, and the work of Kimble el al. on frequency-dependent input-output optics with conventional interferometers. Analytical formulas for the optimal input and output frequency dependencies are obtained. It is shown that injecting squeezed light with the optimal frequency-dependent squeezing angle into the dark port yields an improvement on the noise spectral density by a factor of exp(-2r) (in power) over the entire squeezing bandwidth, where r is the squeezing parameter. It is further shown that frequency-dependent (variational) homodyne read-out leads to an additional increase in sensitivity which is significant in the wings of the doubly resonant structure. The optimal variational input squeezing in case of an ordinary output homodyne detection is shown to be realizable by applying two optical filters on a frequency-independent squeezed vacuum. Throughout this paper, we take as example the signal-recycled topology currently being completed at the GEO600 site. However, theoretical results obtained here are also applicable to the proposed topology of Advanced LIGO.


Classical and Quantum Gravity | 2009

DC-readout of a signal-recycled gravitational wave detector

S. Hild; H. Grote; J. Degallaix; S. Chelkowski; Karsten Danzmann; A. Freise; M. Hewitson; J. Hough; H. Lück; M. Prijatelj; K. A. Strain; J. R. Smith; B. Willke

All first-generation large-scale gravitational wave detectors are operated at the dark fringe and use a heterodyne readout employing radio frequency (RF) modulation–demodulation techniques. However, the experience in the currently running interferometers reveals several problems connected with a heterodyne readout, of which phase noise of the RF modulation is the most serious one. A homodyne detection scheme (DC-readout), using the highly stabilized and filtered carrier light as a local oscillator for the readout, is considered to be a favourable alternative. Recently a DC-readout scheme has been implemented on the GEO 600 detector. We describe the results of first measurements and give a comparison of the performance achieved with homodyne and heterodyne readout. The implications of the combined use of DC-readout and signal recycling are considered.


New Journal of Physics | 2007

Quantum engineering of squeezed states for quantum communication and metrology

H. Vahlbruch; S. Chelkowski; Karsten Danzmann; Roman Schnabel

We report the experimental realization of squeezed quantum states of light, tailored for new applications in quantum communication and metrology. Squeezed states in a broad Fourier frequency band down to 1 Hz have been observed for the first time. Nonclassical properties of light in such a low frequency band are required for high efficiency quantum information storage in electromagnetically induced transparency (EIT) media. The states observed also cover the frequency band of ultra-high precision laser interferometers for gravitational wave detection and can be used to reach the regime of quantum non-demolition interferometry. Furthermore, they cover the frequencies of motion of heavy macroscopic objects and might therefore support attempts to observe entanglement in our macroscopic world.


Proceedings of SPIE | 2004

The status of GEO 600

K. A. Strain; B. Allen; P. Aufmuth; Carsten Aulbert; S. Babak; R. Balasubramanian; B. Barr; Steven J. Berukoff; Alexander Bunkowski; G. Cagnoli; C. A. Cantley; M. M. Casey; S. Chelkowski; D. Churches; T. Cokelaer; Carlo Nicola Colacino; D. R. M. Crooks; Curt Cutler; Karsten Danzmann; R. Davies; R. J. Dupuis; E. J. Elliffe; Carsten Fallnich; A. Franzen; Andreas Freise; S. Goßler; A. Grant; H. Grote; S. Grunewald; J. Harms

The GEO 600 laser interferometer with 600m armlength is part of a worldwide network of gravitational wave detectors. GEO 600 is unique in having advanced multiple pendulum suspensions with a monolithic last stage and in employing a signal recycled optical design. This paper describes the recent commissioning of the interferometer and its operation in signal recycled mode.


Physical Review D | 2009

Prospects of higher-order Laguerre-Gauss modes in future gravitational wave detectors

S. Chelkowski; S. Hild; Andreas Freise

The application of higher-order Laguerre-Gauss (LG) modes in large-scale gravitational wave detectors has recently been proposed. In comparison to the fundamental mode, some higher-order Laguerre-Gauss modes can significantly reduce the contribution of coating Brownian noise. Using frequency domain simulations we give a detailed analysis of the longitudinal and angular control signals derived with a

Collaboration


Dive into the S. Chelkowski's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Andreas Freise

University of Birmingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

S. Hild

University of Glasgow

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

B. Barr

University of Glasgow

View shared research outputs
Top Co-Authors

Avatar

A. Freise

University of Birmingham

View shared research outputs
Top Co-Authors

Avatar

A. Grant

University of Glasgow

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge