S. Doyle
Cardiff University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by S. Doyle.
Astrophysical Journal Supplement Series | 2011
A. Monfardini; A. Benoît; A. Bideaud; Loren J. Swenson; A. Cruciani; P. Camus; C. Hoffmann; F.-X. Desert; S. Doyle; Peter A. R. Ade; Philip Daniel Mauskopf; C. Tucker; M. Roesch; S. Leclercq; K. Schuster; A. Endo; A. Baryshev; J. J. A. Baselmans; L. Ferrari; S. J. C. Yates; O. Bourrion; J. F. Macías-Pérez; C. Vescovi; M. Calvo; C. Giordano
The Neel IRAM KIDs Array (NIKA) is a fully integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. The instrument includes dual-band optics allowing simultaneous imaging at 150 GHz and 220 GHz. The imaging sensors consist of two spatially separated arrays of KIDs. The first array, mounted on the 150 GHz branch, is composed of 144 lumped-element KIDs. The second array (220 GHz) consists of 256 antenna-coupled KIDs. Each of the arrays is sensitive to a single polarization; the band splitting is achieved by using a grid polarizer. The optics and sensors are mounted in a custom dilution cryostat, with an operating temperature of ~70 mK. Electronic readout is realized using frequency multiplexing and a transmission line geometry consisting of a coaxial cable connected in series with the sensor array and a low-noise 4 K amplifier. The dual-band NIKA was successfully tested in 2010 October at the Institute for Millimetric Radio Astronomy (IRAM) 30 m telescope at Pico Veleta, Spain, performing in-line with laboratory predictions. An optical NEP was then calculated to be around 2 × 10–16 W Hz–1/2 (at 1 Hz) while under a background loading of approximately 4 pW pixel–1. This improvement in comparison with a preliminary run (2009) verifies that NIKA is approaching the target sensitivity for photon-noise limited ground-based detectors. Taking advantage of the larger arrays and increased sensitivity, a number of scientifically relevant faint and extended objects were then imaged including the Galactic Center SgrB2 (FIR1), the radio galaxy Cygnus A, and the NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the 150 GHz and 220 GHz atmospheric windows.
Astronomy and Astrophysics | 2010
A. Monfardini; L. J. Swenson; A. Bideaud; F.-X. Desert; S. J. C. Yates; A. Benoît; A. Baryshev; J. J. A. Baselmans; S. Doyle; B. Klein; M. Roesch; Carole Tucker; Peter A. R. Ade; M. Calvo; P. Camus; C. Giordano; Rolf Guesten; C. Hoffmann; S. Leclercq; Philip Daniel Mauskopf; K. Schuster
Context. Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. These instruments typically employ multiplexing ratios well below a hundred. To achieve multiplexing ratios greater than a thousand, it is imperative to investigate technologies that intrinsically incorporate strong multiplexing. One possible solution is the kinetic inductance detector (KID). To assess the potential of this nascent technology, a prototype instrument optimized for the 2 mm atmospheric window was constructed. Known as the Neel IRAM KID Array (NIKA), it has recently been tested at the Institute for Millimetric Radio Astronomy (IRAM) 30-m telescope at Pico Veleta, Spain. Aims. There were four principle research objectives: to determine the practicality of developing a giant array instrument based on KIDs, to measure current in-situ pixel sensitivities, to identify limiting noise sources, and to image both calibration and scientificallyrelevant astronomical sources. Methods. The detectors consisted of arrays of high-quality superconducting resonators electromagnetically coupled to a transmission line and operated at ∼100 mK. The impedance of the resonators was modulated by incident radiation; two separate arrays were tested to evaluate the efficiency of two unique optical-coupling strategies. The first array consisted of lumped element kinetic inductance detectors (LEKIDs), which have a fully planar design properly shaped to enable direct absorbtion. The second array consisted of antenna-coupled KIDs with individual sapphire microlenses aligned with planar slot antennas. Both detectors utilized a single transmission line along with suitable room-temperature digital electronics for continuous readout. Results. NIKA was successfully tested in October 2009, performing in line with expectations. The measurement resulted in the imaging of a number of sources, including planets, quasars, and galaxies. The images for Mars, radio star MWC349, quasar 3C345, and galaxy M 87 are presented. From these results, the optical NEP was calculated to be around 1×10 −15 W/Hz 1/2 . A factor of 10 improvement is expected to be readily feasible by improvements in the detector materials and reduction of performance-degrading spurious radiation.
Astronomy and Astrophysics | 2014
A. Catalano; M. Calvo; N. Ponthieu; R. Adam; A. Adane; Peter A. R. Ade; P. André; A. Beelen; B. Belier; A. Benoît; A. Bideaud; N. Billot; N. Boudou; O. Bourrion; G. Coiffard; B. Comis; A. D'Addabbo; F.-X. Désert; S. Doyle; J. Goupy; C. Kramer; S. Leclercq; J. F. Macías-Pérez; J. Martino; Philip Daniel Mauskopf; F. Mayet; A. Monfardini; F. Pajot; Enzo Pascale; L. Perotto
The New IRAM KID Array (NIKA) instrument is a dual-band imaging camera operating with Kinetic Inductance Detectors (KID) cooled at 100 mK. NIKA is designed to observe the sky at wavelengths of 1.25 and 2.14 mm from the IRAM 30m telescope at Pico Veleta with an estimated resolution of 13 arcsec and 18 arcsec respectively. This work presents the performance of the NIKA camera prior to its opening to the astrophysical community as an IRAM common user facility in early 2014. NIKA is a test-bench for the final NIKA2 instrument to be installed at the end of 2015. The last NIKA observation campaigns on November 2012 and June 2013 have been used to evaluate this performance and to improve the control of systematic effects. We discuss here the dynamical tuning of the readout electronics to optimize the KID working point with respect to background changes and the new technique of atmospheric absorption correction. These modifications improve significantly the overall linearity, sensitivity and absolute calibration performance of NIKA. This is proved on observations of point-like sources for which we obtain a best sensitivity (averaged over all valid detectors) of 40 and 14 mJy.s^1/2 for optimal weather conditions for the 1.25 and 2.14 mm arrays, respectively. NIKA observations of well known extended sources (DR21 complex and the Horsehead nebula) are presented. This performance makes the NIKA camera a competitive astrophysical instrument.
Astronomy and Astrophysics | 2015
R. Adam; B. Comis; J. F. Macías-Pérez; A. Adane; Peter A. R. Ade; P. André; A. Beelen; B. Belier; A. Benoît; A. Bideaud; N. Billot; G. Blanquer; O. Bourrion; M. Calvo; A. Catalano; G. Coiffard; A. Cruciani; A. D'Addabbo; F.-X. Desert; S. Doyle; J. Goupy; C. Kramer; S. Leclercq; J. Martino; Philip Daniel Mauskopf; F. Mayet; A. Monfardini; F. Pajot; Enzo Pascale; L. Perotto
The thermal Sunyaev-Zel’dovich (tSZ) e ect is expected to provide a low scatter mass proxy for galaxy clusters since it is directly proportional to the cluster thermal energy. The tSZ observations have proven to be a powerful tool for detecting and studying them, but high angular resolution observations are now needed to push their investigation to a higher redshift. In this paper, we report high angular (<20 arcsec) resolution tSZ observations of the high-redshift cluster CL J1226.9+3332 (z = 0:89). It was imaged at 150 and 260 GHz using the NIKA camera at the IRAM 30-m telescope. The 150 GHz map shows that CL J1226.9+3332 is morphologically relaxed on large scales with evidence of a disturbed core, while the 260 GHz channel is used mostly to identify point source contamination. NIKA data are combined with those of Planck and X-ray from Chandra to infer the cluster’s radial pressure, density, temperature, and entropy distributions. The total mass profile of the cluster is derived, and we find M500 = 5:96 +1:02 0:79 10 14 M within the radius R500 = 930 +50 kpc, at a 68% confidence level. (R500 is the radius within which the average density is 500 times the critical density at the cluster’s redshift.) NIKA is the prototype camera of NIKA2, a KIDs (kinetic inductance detectors) based instrument to be installed at the end of 2015. This work is, therefore, part of a pilot study aiming at optimizing tSZ NIKA2 large programs.
Astronomy and Astrophysics | 2013
M. Calvo; M. Roesch; F.-X. Desert; A. Monfardini; A. Benoît; P. Mauskopf; Peter A. R. Ade; N. Boudou; O. Bourrion; P. Camus; A. Cruciani; S. Doyle; C. Hoffmann; S. Leclercq; J. F. Macías-Pérez; N. Ponthieu; K. Schuster; Carole Tucker; C. Vescovi
Context. We have developed a dual-band (140 and 220 GHz) mm-wave imaging camera based on superconducting kinetic inductance detector (KID) arrays. Each array contains 132 superconducting resonators whose resonant frequencies are shifted by mm-wave photons absorption. The read out is achieved with a single electronics chain per band, taking advantage of the intrinsic KID frequency-domain multiplexability. The arrays are easily scalable and well adapted for future large format focal plane instruments. NIKA (formerly Neel IRAM KID Array, now New IRAM KID Array) has been specifically designed for the IRAM 30 m telescope at Pico Veleta, and is one of the first instruments using KIDs to have made measurements of astronomical sources. Aims. In this Letter we describe the solutions adopted to improve the calibration accuracy and the sensitivity of the instrument, and we report on the outcome of the 3rd NIKA observing run of October, 2011. Methods. We use a fast electronic modulation of the readout tone for each KID pixel in order to linearize the instrument calibration, which we track with measurements of planets. We also adopt a new design of the KIDs, sensitive to both polarizations, to increase the amount of radiation absorbed and thus the optical efficiency of the system. Results. We measured an average sensitivity on the sky of 21 mJys0.5 per beam at 140 GHz and 140 mJys0.5 at 220 GHz in the best observing conditions (τ220 ≃ 0.2) after atmospheric noise decorrelation. The sensitivity at 220 GHz was limited by the atmospheric attenuation and loading as well as a reduction in the spectral bandwidth due to a misplaced filter. We found the repeatability in the photometry over the entire observing run to be better than 10% in both bands, thus demonstrating a significant improvement over the previous runs. We also find good agreement between NIKA measurements of faint astronomical sources and previous measurements of the same sources.
Review of Scientific Instruments | 2014
Heather McCarrick; D. Flanigan; Glenn Jones; B. R. Johnson; Peter A. R. Ade; Derek Araujo; Kristi J. Bradford; Robin Cantor; George Che; Peter K. Day; S. Doyle; H. G. LeDuc; M. Limon; Vy Luu; P. Mauskopf; Amber D. Miller; Tony Mroczkowski; C. Tucker; Jonas Zmuidzinas
We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background studies. The LEKIDs are made from a thin aluminum film deposited on a silicon wafer and patterned using standard photolithographic techniques at STAR Cryoelectronics, a commercial device foundry. We fabricated 20-element arrays, optimized for a spectral band centered on 150 GHz, to test the sensitivity and yield of the devices as well as the multiplexing scheme. We characterized the detectors in two configurations. First, the detectors were tested in a dark environment with the horn apertures covered, and second, the horn apertures were pointed towards a beam-filling cryogenic blackbody load. These tests show that the multiplexing scheme is robust and scalable, the yield across multiple LEKID arrays is 91%, and the measured noise-equivalent temperatures for a 4 K optical load are in the range 26±6 μK√s.
Proceedings of SPIE | 2012
E. Shirokoff; P. S. Barry; Charles M. Bradford; Goutam Chattopadhyay; Peter K. Day; S. Doyle; S. Hailey-Dunsheath; Matthew I. Hollister; A. Kovács; C. M. McKenney; H. G. LeDuc; Nuria Llombart; D. P. Marrone; Philip Daniel Mauskopf; Roger O'Brient; S. Padin; Theodore Reck; Loren J. Swenson; Jonas Zmuidzinas
SuperSpec is an ultra-compact spectrometer-on-a-chip for millimeter and submillimeter wavelength astronomy. Its very small size, wide spectral bandwidth, and highly multiplexed readout will enable construction of powerful multibeam spectrometers for high-redshift observations. The spectrometer consists of a horn-coupled microstrip feedline, a bank of narrow-band superconducting resonator filters that provide spectral selectivity, and kinetic inductance detectors (KIDs) that detect the power admitted by each filter resonator. The design is realized using thin-film lithographic structures on a silicon wafer. The mm-wave microstrip feedline and spectral filters of the first prototype are designed to operate in the band from 195-310 GHz and are fabricated from niobium with at Tc of 9.2K. The KIDs are designed to operate at hundreds of MHz and are fabricated from titanium nitride with a Tc of ~ 2 K. Radiation incident on the horn travels along the mm-wave microstrip, passes through the frequency-selective filter, and is finally absorbed by the corresponding KID where it causes a measurable shift in the resonant frequency. In this proceedings, we present the design of the KIDs employed in SuperSpec and the results of initial laboratory testing of a prototype device. We will also brie describe the ongoing development of a demonstration instrument that will consist of two 500-channel, R=700 spectrometers, one operating in the 1-mm atmospheric window and the other covering the 650 and 850 micron bands.
THE THIRTEENTH INTERNATIONAL WORKSHOP ON LOW TEMPERATURE DETECTORS—LTD13 | 2009
Loren J. Swenson; J. Minet; G. J. Grabovskij; O. Buisson; F. Lecocq; C. Hoffmann; P. Camus; J.-C. Villégier; S. Doyle; Philip Daniel Mauskopf; M. Roesch; M. Calvo; C. Giordano; S. J. C. Yates; A. Baryshev; J. J. A. Baselmans; A. Benoît; A. Monfardini
Low‐temperature physics and astronomy have traditionally focused on developing exquisitely sensitive single‐pixel detectors. While this has yielded considerable results, these technologies almost uniformly suffer from an inability to scale to large array sizes. In order to circumvent this barrier, frequency‐multiplexing techniques have recently emerged as a suitable solution. Here we present a detailed description of a measurement platform based on frequency‐multiplexed superconducting resonators along with the results from two distinct measurements that leverage this nascent technology to achieve multiple‐device readout. The first application discussed is a seven‐pixel array sensor of the permittivity of liquid helium suitable for quantum hydrodynamic experiments. The second implementation described is a prototype 16‐channel mm‐wavelength detector optimized for ground‐based astronomical detection at the 30 meter Institute for Millimeter‐Wave Radio Astronomy (IRAM) telescope in Pico Veleta, Spain.
Astronomy and Astrophysics | 2018
R. Adam; A. Adane; Peter A. R. Ade; P. André; A. Andrianasolo; H. Aussel; A. Beelen; A. Benoît; A. Bideaud; N. Billot; O. Bourrion; A. Bracco; M. Calvo; A. Catalano; G. Coiffard; B. Comis; M. De Petris; F.-X. Desert; S. Doyle; E. F. C. Driessen; Rhodri Evans; J. Goupy; C. Kramer; G. Lagache; S. Leclercq; J.-P. Leggeri; J.-F. Lestrade; J. F. Macías-Pérez; P. Mauskopf; F. Mayet
Context. Millimetre-wave continuum astronomy is today an indispensable tool for both general astrophysics studies (e.g. star formation, nearby galaxies) and cosmology (e.g. CMB - cosmic microwave background and high-redshift galaxies). General purpose, large-field-of-view instruments are needed to map the sky at intermediate angular scales not accessible by the high-resolution interferometers (e.g. ALMA in Chile, NOEMA in the French Alps) and by the coarse angular resolution space-borne or ground-based surveys (e.g. Planck, ACT, SPT). These instruments have to be installed at the focal plane of the largest single-dish telescopes, which are placed at high altitude on selected dry observing sites. In this context, we have constructed and deployed a three-thousand-pixel dual-band (150 GHz and 260 GHz, respectively 2 mm and 1.15 mm wavelengths) camera to image an instantaneous circular field-ofview of 6.5 arcminutes in diameter, and configurable to map the linear polarisation at 260 GHz. Aims. First, we are providing a detailed description of this instrument, named NIKA2 (New IRAM KID Arrays 2), in particular focussing on the cryogenics, optics, focal plane arrays based on Kinetic Inductance Detectors (KID), and the readout electronics. The focal planes and part of the optics are cooled down to the nominal 150 mK operating temperature by means of an ad-hoc dilution refrigerator. Secondly, we are presenting the performance measured on the sky during the commissioning runs that took place between October 2015 and April 2017 at the 30-meter IRAM (Institut of Millimetric Radio Astronomy) telescope at Pico Veleta, near Granada (Spain). Methods. We have targeted a number of astronomical sources. Starting from beam-maps on primary and secondary calibrators we have then gone to extended sources and faint objects. Both internal (electronic) and on-the-sky calibrations are applied. The general methods are described in the present paper. Results. NIKA2 has been successfully deployed and commissioned, performing in-line with expectations. In particular, NIKA2 exhibits full width at half maximum (FWHM) angular resolutions of around 11 and 17.5 arc-seconds at respectively 260 and 150 GHz. The noise equivalent flux densities (NEFD) are, at these two respective frequencies, 33±2 and 8±1 mJy ·s 1/2. A first successful science verification run was achieved in April 2017. The instrument is currently offered to the astronomy community and will remain available for at least the following ten years.
Journal of Low Temperature Physics | 2014
Alessandro Monfardini; R. Adam; A. Adane; Peter A. R. Ade; P. André; A. Beelen; B. Belier; A. Benoît; A. Bideaud; N. Billot; O. Bourrion; M. Calvo; A. Catalano; G. Coiffard; B. Comis; A. D'Addabbo; F.-X. Desert; S. Doyle; J. Goupy; C. Kramer; S. Leclercq; J. F. Macías-Pérez; J. Martino; Philip Daniel Mauskopf; F. Mayet; F. Pajot; Enzo Pascale; N. Ponthieu; V. Revéret; L. Rodriguez
NIKA (New IRAM KID Arrays) is a dual-band imaging instrument installed at the IRAM (Institut de RadioAstronomie Millimetrique) 30-meter telescope at Pico Veleta (Spain). Two distinct Kinetic Inductance Detectors (KID) focal planes allow the camera to simultaneous image a field-of-view of about 2 arc-min in the bands 125 to 175 GHz (150 GHz) and 200 to 280 GHz (240 GHz). The sensitivity and stability achieved during the last commissioning Run in June 2013 allows opening the instrument to general observers. We report here the latest results, in particular in terms of sensitivity, now comparable to the state-of-the-art Transition Edge Sensors (TES) bolometers, relative and absolute photometry. We describe briefly the next generation NIKA-2 instrument, selected by IRAM to occupy, from 2015, the continuum imager/polarimeter slot at the 30-m telescope.