Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where S. Hawkins is active.

Publication


Featured researches published by S. Hawkins.


Physica Medica | 2008

A compact linac for intensity modulated proton therapy based on a dielectric wall accelerator

George J. Caporaso; T R Mackie; Stephen E. Sampayan; Yu-Jiuan Chen; D. Blackfield; J. R. Harris; S. Hawkins; C. Holmes; Scott D. Nelson; Arthur C. Paul; Brian R. Poole; Mark A. Rhodes; David M. Sanders; J. Sullivan; L. Wang; J. Watson; Paul J. Reckwerdt; R. Schmidt; D. Pearson; R.W. Flynn; D. Matthews; J. Purdy

A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. Feasibility tests of an optimization system for selecting the position, energy, intensity and spot size for a collection of spots comprising the treatment are underway. A prototype is being designed and concept designs of the envelope and environmental needs of the unit are beginning. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, SiC photoconductive switches and compact proton sources.


ieee particle accelerator conference | 2007

High gradient induction accelerator

George J. Caporaso; S. Sampayan; Y.-J. Chen; D. Blackfield; J. R. Harris; S. Hawkins; C. Holmes; Michael L. Krogh; Scott D. Nelson; W. Nunnally; Arthur C. Paul; Brian R. Poole; Mark A. Rhodes; D. Sanders; K. Selenes; James S. Sullivan; L. Wang; J. Watson

A new type of compact induction accelerator is under development at the Lawrence Livermore National Laboratory that promises to increase the average accelerating gradient by at least an order of magnitude over that of existing induction machines. The machine is based on the use of high gradient vacuum insulators, advanced dielectric materials and switches and is stimulated by the desire for compact flash X-ray radiography sources. Research describing an extreme variant of this technology aimed at proton therapy for cancer will be described. Progress in applying this technology to several applications will be reviewed.


ieee international pulsed power conference | 2005

Development of a Compact Radiography Accelerator Using Dielectric Wall Accelerator Technology

S. Sampayan; George J. Caporaso; Yu-Jiuan Chen; S. Hawkins; C. Holmes; M. Krogh; James F. McCarrick; Scott D. Nelson; W. Nunnally; Brian R. Poole; Mark A. Rhodes; D. Sanders; K. Selenes; James S. Sullivan; L. Wang; J. Watson

We are developing an inexpensive compact accelerator system primarily intended for pulsed radiography. Design characteristics are an 8 MeV endpoint energy, 2 kA beam current, a cell gradient of approximately 3 MV/m (for an overall accelerator length is 2-3 m), and <


IEEE Transactions on Dielectrics and Electrical Insulation | 2007

Multilayer High-Gradient Insulators

J. R. Harris; R.M. Anaya; D. Blackfield; Y.-J. Chen; Steven Falabella; S. Hawkins; C. Holmes; Arthur C. Paul; S. Sampayan; D. Sanders; J. Watson; George J. Caporaso; M. Krogh

1/Volt capital costs. Such designs have been made possible with the development of high specific energy dielectrics (>10J/cm3), specialized transmission line designs and multi-gap laser triggered low jitter (<1 ns) gas switches. In this geometry, the pulse forming lines, switches, and insulator/beam pipe are fully integrated within each cell to form a compact, stand-alone, stackable unit. We detail our research and modeling to date, recent high voltage test results, and the integration concept of the cells into a radiographic system.


Journal of Applied Physics | 2008

Vacuum Insulator Development for the Dielectric Wall Accelerator

J. R. Harris; D. Blackfield; George J. Caporaso; Y.-J. Chen; S. Hawkins; M. Kendig; Brian R. Poole; D. Sanders; M. Krogh; J. E. Managan

Multilayer high-gradient insulators are vacuum insulating structures composed of thin, alternating layers of dielectric and metal. They are currently being developed for application to high-current accelerators and related pulsed power systems. This paper describes some of the high-gradient insulator research currently being conducted at Lawrence Livermore National Laboratory


IEEE Transactions on Plasma Science | 2009

Plasma Cathode for a Short-Pulse Dielectric Wall Accelerator

J. R. Harris; B.C. Hickman; R.M. Anaya; E.G. Cook; S. Hawkins; C. Holmes; Joel R. Stanley; J. Watson; George J. Caporaso

At Lawrence Livermore National Laboratory, we are developing a new type of accelerator, known as a dielectric wall accelerator, in which compact pulse-forming lines directly apply an accelerating field to the beam through an insulating vacuum boundary. The electrical strength of this insulator may define the maximum gradient achievable in these machines. To increase the system gradient, we use “high-gradient insulators” composed of alternating layers of dielectric and metal for the vacuum insulator. In this paper, we present our recent results from experiment and simulation, including successful testing of a high-gradient insulator in a functioning dielectric wall accelerator cell. Our results indicate that proper high-voltage conditioning of the insulators can delay the onset of flashover, that the observed conditioning consists of both a permanent and a temporary part, and that the insulators’ voltage-holding capability increases with increasing dielectric layer thickness.


Medical Physics | 2007

TH‐C‐AUD‐09: A Proposal for a Novel Compact Intensity Modulated Proton Therapy System Using a Dielectric Wall Accelerator

T Mackie; George J. Caporaso; S. Sampayan; Yu-Jiuan Chen; D. Blackfield; J. R. Harris; S. Hawkins; C. Holmes; Scott D. Nelson; Arthur C. Paul; Brian R. Poole; Mark A. Rhodes; D. Sanders; James S. Sullivan; L. Wang; J. Watson; Paul J. Reckwerdt; R Schmidt; D Pearson; R Flynn; D. Matthews; James A. Purdy

The Beam Research Program at Lawrence Livermore National Laboratory is continuing development of the dielectric wall accelerator (DWA), a type of accelerator which uses stacked pulse-forming lines (PFLs) to apply an accelerating field directly to the beam through a nonconducting vacuum boundary. Here, we report operation of a DWA as an electron diode using a surface flashover plasma cathode. Peak perveances in excess of 6 times 10-6A/V3/2 were measured, with current extraction and pulse train format depending on flashover source timing and PFL switching speed.


Photonics West '99 Symposium, San Jose, CA (US), 01/23/1999--01/29/1999 | 1999

Performance results of the high-gain Nd:glass engineering prototype preamplifier module (PAM) for the National Ignition Facility (NIF)

Mikael D. Martinez; Kenneth M. Skulina; Fred J. Deadrick; John K. Crane; Bryan D. Moran; John Braucht; Bobby Jones; S. Hawkins; Ronald Tilley; James Crawford; Donald F. Browning; Frank A. Penko

Purpose: A novel compact CT‐guided intensity modulated protonradiotherapy (IMPT) system is introduced. The system is being designed to deliver motion‐managed IMPT to large target volumes. The system will be ideal for large and complex target volumes in young patients. Method and Materials: The basis of the design is the dielectric wall accelerator (DWA) system being developed at Lawrence Livermore National Laboratory (LLNL). The DWA will use fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width, all of which will be optimized in the IMPT planning system. It is anticipated that no magnets will be required and the neutron contamination will be very low. The system will be capable of being sited in a conventional linac vault. Results: The design specifications have been met in some component tests. Gradients of 100 MV/m have been achieved in small HGI samples. Optical switches based on fast laser switched SiC has been achieved. Feasibility tests of an optimization system for selecting the position, energy, intensity and spot size for a collection of spots comprising the treatment are underway. A prototype is being designed and concept designs of the envelope and environmental needs of the unit has commenced. Conclusion: The DWA accelerator represents breakthrough technology for intensity modulated proton therapy. The system is being designed from the ground up to be capable of CT‐guided intensity modulated proton therapy and to be housed in a conventional linac vault. Conflict of Interest:Some of the authors have financial interest in TomoTherapy Inc., which has licensed the DWA technology from LLNL.


ieee international pulsed power conference | 2005

Experiments with UV Laser Triggered Spark Gaps in a Stacked Blumlein System

W. Nunnally; F. V. Allen; S. Hawkins; C. Holmes; S. Sampayan; G. J. Corporaso

We describe recent, energetics performance results on the engineering preamplifier module (PAM) prototype located in the front end of the 1.8 MJ National Ignition Facility laser system. Three vertically mounted subsystem located in the PAM provide laser gain as well as spatial beam shaping. The first subsystem in the PAM prototype is a diode pumped, Nd:glass, linear, TEM00, 4.5 m long regenerative amplifier cavity. With a single diode pumped head, we amplify a 1 nJ, mode matched, temporally shaped (approximately equals 20 ns) seed pulse by a factor of approximately 107 to 20 mJ. The second subsystem in the PAM is the beam shaping module, which magnifies the gaussian output beam of the regenerative amplifier to provide a 30 mm X 30 mm square beam that is spatially shaped in two dimensions to pre- compensate for radial gain profiles in the main amplifiers. The final subsystem in the PAM is the 4-pass amplifier which relay images the 1 mJ output of the beam shaper through four gain passes in a (phi) 5 cm X 48 cm flashlamp pumped rod amplifier, amplifying the energy to 17 J. The system gain of the PAM is 1010. Each PAM provides 3 J of injected energy to four separate main amplifier chains which in turn delivers 1.8 MJ in 192 frequency converted laser beams to the target for a broad range of laser fusion experiments.


international power modulator symposium and high voltage workshop | 2002

Solid-state modulated kicker pulser

B.S. Lee; F.V. Allen; R.M. Anaya; E.G. Cook; S. Hawkins; B.C. Hickman; J. Watson

Very compact pulsed power systems can be fabricated with stacked Blumlein lines (SBL). The critical component necessary to field a viable SBL system is the switch that is integrated into one of the two transmission lines that forms each Blumlein in the stack. The critical parameters of the switch are the current inductive time constant, the switch resistive phase closure time, and the switch closure jitter all of which must be much lower than the desired load pulse risetime. Another important consideration / requirement is the method of triggering the switches in the stack, which should be compact and provide high voltage isolation while delivering very precise, controllable switching. This paper discusses switch requirements from basic circuit analysis and the experimental setup, parameters, and results of an experiment to investigate the feasibility of UV laser triggering of up to 40 Blumlein lines in a very compact SBL. In addition, the method of fabricating a very compact SBL transmission lines is presented. Then the behavior of the switch parameters in the stack when closure is initiated with a UV laser pulse is presented. Specifically, the time varying inductance and resistance of the laser initiated gas discharge channel is presented and compared with a circuit model to elucidate the switch performance.

Collaboration


Dive into the S. Hawkins's collaboration.

Top Co-Authors

Avatar

George J. Caporaso

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

J. R. Harris

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

C. Holmes

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

J. Watson

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Arthur C. Paul

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Brian R. Poole

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

D. Sanders

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

James S. Sullivan

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

L. Wang

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Scott D. Nelson

Lawrence Livermore National Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge