Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where S. Lindemann is active.

Publication


Featured researches published by S. Lindemann.


Physical Review Letters | 2011

Dark Matter Results from 225 Live Days of XENON100 Data

E. Aprile; K. Arisaka; F. Arneodo; A. Askin; L. Baudis; A. Behrens; K. Bokeloh; E. Brown; T. Bruch; G. Bruno; João Cardoso; W. T. Chen; B. Choi; D. Cline; E. Duchovni; S. Fattori; A. D. Ferella; F. Gao; Karl-Ludwig Giboni; E. Gross; A. Kish; C. W. Lam; J. Lamblin; R. F. Lang; C. Levy; K. E. Lim; Q. Lin; S. Lindemann; Manfred Lindner; J. A. M. Lopes

We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso for 13 months during 2011 and 2012. XENON100 features an ultralow electromagnetic background of (5.3 ± 0.6) × 10(-3) events/(keV(ee) × kg × day) in the energy region of interest. A blind analysis of 224.6 live days × 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the predefined nuclear recoil energy range of 6.6-30.5 keV(nr) are consistent with the background expectation of (1.0 ± 0.2) events. A profile likelihood analysis using a 6.6-43.3 keV(nr) energy range sets the most stringent limit on the spin-independent elastic weakly interacting massive particle-nucleon scattering cross section for weakly interacting massive particle masses above 8 GeV/c(2), with a minimum of 2 × 10(-45) cm(2) at 55 GeV/c(2) and 90% confidence level.


Physical Review D | 2011

Likelihood Approach to the First Dark Matter Results from XENON100

E. Aprile; K. Arisaka; F. Arneodo; A. Askin; L. Baudis; A. Behrens; K. Bokeloh; E. Brown; T. Bruch; João Cardoso; Bernard C. K. Choi; D. Cline; E. Duchovni; S. Fattori; A. D. Ferella; Karl-Ludwig Giboni; Eduardo Gross; A. Kish; C. W. Lam; J. Lamblin; R. F. Lang; K. E. Lim; S. Lindemann; Manfred Lindner; J. A. M. Lopes; T. Marrodán Undagoitia; Y. Mei; A. J. Melgarejo Fernandez; K. Ni; U. Oberlack

Many experiments that aim at the direct detection of dark matter are able to distinguish a dominant background from the expected feeble signals, based on some measured discrimination parameter. We develop a statistical model for such experiments using the profile likelihood ratio as a test statistic in a frequentist approach. We take data from calibrations as control measurements for signal and background, and the method allows the inclusion of data from Monte Carlo simulations. Systematic detector uncertainties, such as uncertainties in the energy scale, as well as astrophysical uncertainties, are included in the model. The statistical model can be used to either set an exclusion limit or to quantify a discovery claim, and the results are derived with the proper treatment of statistical and systematic uncertainties. We apply the model to the first data release of the XENON100 experiment, which allows one to extract additional information from the data, and place stronger limits on the spin-independent elastic weakly interacting massive particles nucleon scattering cross section. In particular, we derive a single limit, including all relevant systematic uncertainties, with a minimum of 2.4×10-44  cm2 for weakly interacting massive particles with a mass of 50  GeV/c2. © 2011 American Physical Society


Physical Review D | 2011

Implications on inelastic dark matter from 100 live days of XENON100 data

E. Aprile; K. Arisaka; F. Arneodo; A. Askin; L. Baudis; A. Behrens; K. Bokeloh; E. Brown; T. Bruch; G. Bruno; João Cardoso; W. T. Chen; B. Choi; D. Cline; E. Duchovni; S. Fattori; A. D. Ferella; F. Gao; Karl-Ludwig Giboni; E. Gross; A. Kish; C. W. Lam; J. Lamblin; R. F. Lang; C. Levy; K. E. Lim; Q. Lin; S. Lindemann; Manfred Lindner; J. A. M. Lopes

The XENON100 experiment has recently completed a dark matter run with 100.9 live-days of data, taken from January to June 2010. Events in a 48kg fiducial volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A total of three events have been found in the predefined signal region, compatible with the background prediction of (1.8 \pm 0.6) events. Based on this analysis we present limits on the WIMP-nucleon cross section for inelastic dark matter. With the present data we are able to rule out the explanation for the observed DAMA/LIBRA modulation as being due to inelastic dark matter scattering off iodine at a 90% confidence level.


Astroparticle Physics | 2014

Analysis of the XENON100 Dark Matter Search Data

E. Aprile; M. Alfonsi; K. Arisaka; F. Arneodo; C. Balan; L. Baudis; A. Behrens; P. Beltrame; K. Bokeloh; E. Brown; G. Bruno; R. Budnik; João Cardoso; W. T. Chen; B. Choi; D. Cline; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; F. Gao; M. Garbini; Karl-Ludwig Giboni; L. W. Goetzke; C. Grignon; E. Gross; W. Hampel

The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have been used in the 100.9 and 224.6 live days science runs from which results on spin-independent elastic, spin-dependent elastic and inelastic WIMP-nucleon cross-sections have already been reported.


Journal of Physics G | 2014

Observation and applications of single-electron charge signals in the XENON100 experiment

E. Aprile; M. Alfonsi; K. Arisaka; F. Arneodo; C. Balan; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; K. Bokeloh; Abbe Brown; E. Brown; S. Bruenner; G. Bruno; R. Budnik; João Cardoso; W. T. Chen; B. Choi; A. P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; F. Gao; M. Garbini; C. Ghag; Karl-Ludwig Giboni

The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter weakly interacting massive particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.


European Physical Journal C | 2015

Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

E. Aprile; F. Agostini; M. Alfonsi; L. Arazi; K. Arisaka; F. Arneodo; M. Auger; C. Balan; P. Barrow; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; Abbe Brown; E. Brown; S. Bruenner; G. Bruno; R. Budnik; Lukas Bütikofer; João Cardoso; Daniel Coderre; A. P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; A. Di Giovanni; E. Duchovni; S. Fattori; A. D. Ferella; A. Fieguth

The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.


Journal of Instrumentation | 2014

Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment

E. Aprile; F. Agostini; M. Alfonsi; K. Arisaka; F. Arneodo; M. Auger; C. Balan; P. Barrow; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; K. Bokeloh; A. Breskin; Abbe Brown; E. Brown; S. Bruenner; G. Bruno; R. Budnik; João Cardoso; A. P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; M. Garbini; C. Geis

XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of 2 10-47 c 2 for WIMP masses around 50 GeV2, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of ~ 10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons (>99.5%) and showers of secondary particles from muon interactions in the rock (>70%). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.


European Physical Journal C | 2014

Krypton assay in xenon at the ppq level using a gas chromatographic system and mass spectrometer

S. Lindemann; H. Simgen

We have developed a new method to measure krypton traces in xenon at unprecedented low concentrations. This is a mandatory task for many near-future low-background particle physics detectors. Our system separates krypton from xenon using cryogenic gas chromatography. The amount of krypton is then quantified using a mass spectrometer. We demonstrate that the system has achieved a detection limit of 8 ppq (parts per quadrillion) and present results of distilled xenon with krypton concentrations below 1 ppt.


Journal of Physics G | 2013

The neutron background of the XENON100 dark matter search experiment

E. Aprile; M. Alfonsi; K. Arisaka; F. Arneodo; C. Balan; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; K. Bokeloh; Abbe Brown; E. Brown; G. Bruno; R. Budnik; João Cardoso; W. T. Chen; B. Choi; A.P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; F. Gao; M. Garbini; C. Ghag; Karl-Ludwig Giboni; L. W. Goetzke

The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso, aims to directly detect dark matter in the form of weakly interacting massive particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from (α, n) reactions and spontaneous fission due to natural radioactivity in the detector and shield materials, as well as muon-induced neutrons. Based on Monte Carlo simulations and using measured radioactive contaminations of all detector components, we predict the nuclear recoil backgrounds for the WIMP search results published by the XENON100 experiment in 2011 and 2012, 0.11 events and 0.17 events, respectively, and conclude that they do not limit the sensitivity of the experiment.TheXENON100 experiment, installed underground at the LaboratoriNazionali del Gran Sasso, aims to directly detect dark matter in the form of weakly interacting massive particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from (alpha, n) reactions and spontaneous fission due to natural radioactivity in the detector and shield materials, as well as muon-induced neutrons. Based on MonteCarlo simulations and using measured radioactive contaminations of all detector components, we predict the nuclear recoil backgrounds for the WIMP search results published by theXENON100 experiment in 2011 and 2012, 0.11(-0.04)(+0.08) events and 0.17(-0.07)(+0.12) events, respectively, and conclude that they do not limit the sensitivity of the experiment.


Journal of Instrumentation | 2012

The distributed Slow Control System of the XENON100 Experiment

E. Aprile; M. Alfonsi; K. Arisaka; F. Arneodo; C. Balan; L. Baudis; A. Behrens; P. Beltrame; K. Bokeloh; E. Brown; G. Bruno; R. Budnik; M. Le Calloch; João Cardoso; W. T. Chen; B. Choi; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; F. Gao; M. Garbini; Karl-Ludwig Giboni; L. W. Goetzke; C. Grignon; E. Gross; W. Hampel

The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature. The system software was designed according to the rules of Object-Oriented Programming and coded in Java, thus promoting code reusability and maximum flexibility during commissioning of the experiment. The SCS has been continuously monitoring the XENON100 detector since mid 2008, remotely recording hundreds of parameters on a few dozen instruments in real time, and setting emergency alarms for the most important variables.

Collaboration


Dive into the S. Lindemann's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

E. Brown

Rensselaer Polytechnic Institute

View shared research outputs
Top Co-Authors

Avatar

K. Arisaka

University of California

View shared research outputs
Top Co-Authors

Avatar

F. Arneodo

New York University Abu Dhabi

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge