S. Reichard
Purdue University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by S. Reichard.
Physical Review D | 2014
E. Aprile; F. Agostini; M. Alfonsi; K. Arisaka; F. Arneodo; M. Auger; C. Balan; P. Barrow; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; K. Bokeloh; A. Brown; E. Brown; Stefan Brünner; G. Bruno; R. Budnik; João Cardoso; A.P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; F. Gao; M. Garbini; C. Geis
We present the first results of searches for axions and axionlike particles with the XENON100 experiment. The axion-electron coupling constant, g Ae , has been probed by exploiting the axioelectric effect in liquid xenon. A profile likelihood analysis of 224.6 live days × 34-kg exposure has shown no evidence for a signal. By rejecting g Ae larger than 7.7×10 −12 (90% C.L.) in the solar axion search, we set the best limit to date on this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions heavier than 0.3 and 80 eV/c 2 , respectively. For axionlike particles, under the assumption that they constitute the whole abundance of dark matter in our galaxy, we constrain g Ae to be lower than 1×10 −12 (90% C.L.) for masses between 5 and 10 keV/c 2 .
European Physical Journal C | 2015
E. Aprile; F. Agostini; M. Alfonsi; L. Arazi; K. Arisaka; F. Arneodo; M. Auger; C. Balan; P. Barrow; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; Abbe Brown; E. Brown; S. Bruenner; G. Bruno; R. Budnik; Lukas Bütikofer; João Cardoso; Daniel Coderre; A. P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; A. Di Giovanni; E. Duchovni; S. Fattori; A. D. Ferella; A. Fieguth
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
Journal of Instrumentation | 2014
E. Aprile; F. Agostini; M. Alfonsi; K. Arisaka; F. Arneodo; M. Auger; C. Balan; P. Barrow; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; K. Bokeloh; A. Breskin; Abbe Brown; E. Brown; S. Bruenner; G. Bruno; R. Budnik; João Cardoso; A. P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; M. Garbini; C. Geis
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of 2 10-47 c 2 for WIMP masses around 50 GeV2, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of ~ 10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons (>99.5%) and showers of secondary particles from muon interactions in the rock (>70%). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.
Physical Review D | 2013
L. Baudis; Gaudenz Kessler; Philipp Klos; R. F. Lang; Javier Menéndez; S. Reichard; A. Schwenk
Direct dark matter detection focuses on elastic scattering of dark matter particles off nuclei. In this study, we explore inelastic scattering where the nucleus is excited to a low-lying state of 10-100 keV, with subsequent prompt de-excitation. We calculate the inelastic structure factors for the odd-mass xenon isotopes based on state-of-the-art large-scale shell-model calculations with chiral effective field theory WIMP-nucleon currents. For these cases, we find that the inelastic channel is comparable to or can dominate the elastic channel for momentum transfers around 150 MeV. We calculate the inelastic recoil spectra in the standard halo model, compare these to the elastic case, and discuss the expected signatures in a xenon detector, along with implications for existing and future experiments. The combined information from elastic and inelastic scattering will allow to determine the dominant interaction channel within one experiment. In addition, the two channels probe different regions of the dark matter velocity distribution and can provide insight into the dark halo structure. The allowed recoil energy domain and the recoil energy at which the integrated inelastic rates start to dominate the elastic channel depend on the mass of the dark matter particle, thus providing a potential handle to constrain its mass.
Physical Review D | 2017
L. Baudis; A. Brown; Chiara Capelli; M. Galloway; S. Kazama; A. Kish; F. Piastra; S. Reichard; J. Wulf
We present the first constraints on the spin-dependent, inelastic scattering cross section of weakly interacting massive particles (WIMPs) on nucleons from XENON100 data with an exposure of
Journal of Physics: Conference Series | 2017
S. Reichard; R. F. Lang; Christopher McCabe; M. Selvi; Irene Tamborra
7.64 \times 10^3 kg \cdot
Physical Review D | 2016
R. F. Lang; Christopher McCabe; S. Reichard; M. Selvi; Irene Tamborra
days. XENON100 is a dual-phase xenon time projection chamber with 62 kg of active mass, operated at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy and designed to search for nuclear recoils from WIMP-nucleus interactions. Here we explore inelastic scattering, where a transition to a low-lying excited nuclear state of
Physical Review D | 2017
E. Aprile; F. Agostini; M. Alfonsi; K. Arisaka; F. Arneodo; M. Auger; C. Balan; P. Barrow; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; K. Bokeloh; April S. Brown; E. Brown; S. Bruenner; G. Bruno; R. Budnik; João Cardoso; A. P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; F. Gao; M. Garbini; C. Geis
^{129}Xe