Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by S. Sala.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000
Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; W. Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; E. Grigoriev; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania
The paper reviews measurements of the radiation tolerance of CVD diamond for irradiation with 24 GeV/c protons, 300 MeV/c pions and 1 MeV neutrons. For proton and neutron irradiation, the measured charge signal spectrum is compared with the spectrum calculated by a model. Irradiation by particles causes radiation damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model shows that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. In addition, we observed after proton irradiation at the charge signal spectrum a decrease of the number of small signals. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal. (11 refs).
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2003
Wolfgang Adam; B. Bellini; E. Berdermann; P. Bergonzo; W. De Boer; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; W. Dabrowski; P. Delpierre; J. Doroshenko; W. Dulinski; B. Van Eijk; A. Fallou; P. Fischer; F. Fizzotti; C. Furetta; K. K. Gan; N. Ghodbane; E. Grigoriev; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan
Chemical Vapor Deposited (CVD) polycrystalline diamond has been proposed as a radiation-hard alternative to silicon in the extreme radiation levels occurring close to the interaction region of the Large Hadron Collider. Due to an intense research effort, reliable high-quality polycrystalline CVD diamond detectors, with up to 270μm charge collection distance and good spatial uniformity, are now available. The most recent progress on the diamond quality, on the development of diamond trackers and on radiation hardness studies are presented and discussed.
Diamond and Related Materials | 2001
M. Krammer; Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania
Abstract CVD diamond material was used to build position-sensitive detectors for single-charged particles to be employed in high-intensity physics experiments. To obtain position information, metal contacts shaped as strips or pixels are applied to the detector surface for one- or two-dimensional coordinate measurement. Strip detectors 2×4 cm2 in size with a strip distance of 50 μm were tested. Pixel detectors of various pixel sizes were bump bonded to electronics chips and investigated. A key issue for the use of these sensors in high intensity experiments is the radiation hardness. Several irradiation experiments were carried out with pions, protons and neutrons exceeding a fluence of 1015 particles/cm2. The paper presents an overview of the results obtained with strip and pixel detectors in high-energy test beams and summarises the irradiation studies.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2002
Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania; J. Kaplon
Abstract CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15 /cm 2 ) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2×10 15 p / cm 2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9×10 15 π / cm 2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000
Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania; J. Kaplon
Abstract In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2006
Wolfgang Adam; W. De Boer; E. Borchi; M. Bruzzi; C. Colledani; P. D’Angelo; V. Dabrowski; W. Dulinski; B. Van Eijk; V. Eremin; F. Fizzotti; H. Frais-Kölbl; C. Furetta; K. K. Gan; A. Gorišek; E. Griesmayer; E. Grigoriev; F. Hartjes; J. Hrubec; F. Huegging; H. Kagan; J. Kaplon; R. Kass; K.T. Knöpfle; M. Krammer; W. Lange; A. Logiudice; C. Manfredotti; M. Mathes; D. Menichelli
Archive | 2006
W. Adam; R. Kass; C. Sutera; J. Hrubec; M. Sampietro; E. Berdermann; W. Trischuk; F. Fizzotti; E. Grigoriev; B. Van Eijk; E. Borchi; F. Hugging; L. MacLynne; A. Lo Giudice; H. Kagan; E. Griesmayer; R.-S. Lu; S. Schnetzer; W. Dulinski; C. Colledani; A. Gorišek; P. D'Angelo; M. Pernicka; H. Frais-Kölbl; W. Dabrowski; M. Krammer; R. Stone; J.L. Riester; B. Vincenzo; W. D. Zeuner
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2002
Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D’Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania; J. Kaplon
European Physical Journal C | 2004
Wolfgang Adam; E. Berdermann; P. Bergonzo; W. De Boer; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D’Angelo; W. Dabrowski; P. Delpierre; W. Dulinski; J. Doroshenko; B. Van Eijk; A. Fallou; P. Fischer; F. Fizzotti; C. Furetta; K. K. Gan; N. Ghodbane; E. Grigoriev; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; J. Kaplon
In: (pp. pp. 739-743). (2002) | 2002
W. Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; W. Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; Gregory David Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D. R. Kania; J. Kaplon