Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where S. W. Leman is active.

Publication


Featured researches published by S. W. Leman.


Science | 2009

Dark matter search results from the CDMS II experiment.

J. Cooley; Z. Ahmed; D. S. Akerib; S. Arrenberg; C. N. Bailey; D. Balakishiyeva; L. Baudis; D. A. Bauer; P. L. Brink; T. Bruch; R. Bunker; B. Cabrera; David O. Caldwell; P. Cushman; M. Daal; F. DeJongh; M. R. Dragowsky; L. Duong; S. Fallows; E. Figueroa-Feliciano; J. Filippini; M. Fritts; S. R. Golwala; D. R. Grant; J. Hall; R. Hennings-Yeomans; S. A. Hertel; D. Holmgren; L. Hsu; M. E. Huber

News from the Dark Side? Dark matter is thought to represent 85% of all matter in the universe and to have been responsible for the formation of structure in the early universe, but its nature is still a mystery. Ahmed et al. (p. 1619, published online 11 February; see the Perspective by Lang) describe the results from the completed Cryogenic Dark Matter Search (CDMS II) experiment, which searched for dark matter in the form of weakly interacting massive particles (WIMP). Two candidate signals were observed, whereas only one background event was expected. The probability of having two or more events from the background would have been 23%. The results of this analysis cannot be interpreted with confidence as evidence for WIMP interactions, but, at the same time, neither event can be ruled out as representing signal. Details of possible, but unlikely, detection events produced by dark matter are reported. Astrophysical observations indicate that dark matter constitutes most of the mass in our universe, but its nature remains unknown. Over the past decade, the Cryogenic Dark Matter Search (CDMS II) experiment has provided world-leading sensitivity for the direct detection of weakly interacting massive particle (WIMP) dark matter. The final exposure of our low-temperature germanium particle detectors at the Soudan Underground Laboratory yielded two candidate events, with an expected background of 0.9 ± 0.2 events. This is not statistically significant evidence for a WIMP signal. The combined CDMS II data place the strongest constraints on the WIMP-nucleon spin-independent scattering cross section for a wide range of WIMP masses and exclude new parameter space in inelastic dark matter models.Z. Ahmed, D.S. Akerib, S. Arrenberg, C.N. Bailey, D. Balakishiyeva, L. Baudis, D.A. Bauer, P.L. Brink, T. Bruch, R. Bunker, B. Cabrera, D.O. Caldwell, J. Cooley, P. Cushman, M. Daal, F. DeJongh, M.R. Dragowsky, L. Duong, S. Fallows, E. Figueroa-Feliciano, J. Filippini, M. Fritts, S.R. Golwala, D.R. Grant, J. Hall, R. Hennings-Yeomans, S.A. Hertel, D. Holmgren, L. Hsu, M.E. Huber, O. Kamaev, M. Kiveni, M. Kos, S.W. Leman, R. Mahapatra, V. Mandic, K.A. McCarthy, N. Mirabolfathi, D. Moore, H. Nelson, R.W. Ogburn, A. Phipps, M. Pyle, X. Qiu, E. Ramberg, W. Rau, A. Reisetter, 7 T. Saab, B. Sadoulet, 13 J. Sander, R.W. Schnee, D.N. Seitz, B. Serfass, K.M. Sundqvist, M. Tarka, P. Wikus, S. Yellin, 14 J. Yoo, B.A. Young, and J. Zhang (CDMS Collaboration) Division of Physics, Mathematics & Astronomy, California Institute of Technology, Pasadena, CA 91125, USA Department of Physics, Case Western Reserve University, Cleveland, OH 44106, USA Fermi National Accelerator Laboratory, Batavia, IL 60510, USA Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA Department of Physics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA Department of Physics, Queen’s University, Kingston, ON, Canada, K7L 3N6 Department of Physics, St. Olaf College, Northfield, MN 55057 USA Department of Physics, Santa Clara University, Santa Clara, CA 95053, USA Department of Physics, Southern Methodist University, Dallas, TX 75275, USA Department of Physics, Stanford University, Stanford, CA 94305, USA Department of Physics, Syracuse University, Syracuse, NY 13244, USA Department of Physics, Texas A & M University, College Station, TX 77843, USA Department of Physics, University of California, Berkeley, CA 94720, USA Department of Physics, University of California, Santa Barbara, CA 93106, USA Departments of Phys. & Elec. Engr., University of Colorado Denver, Denver, CO 80217, USA Department of Physics, University of Florida, Gainesville, FL 32611, USA School of Physics & Astronomy, University of Minnesota, Minneapolis, MN 55455, USA Physics Institute, University of Zürich, Winterthurerstr. 190, CH-8057, Switzerland Division of Physics, Mathematics, and Astronomy, California Institute of Technology, Pasadena, CA 91125, USA


Physical Review Letters | 2011

Results from a Low-Energy Analysis of the CDMS II Germanium Data

Z. Ahmed; D. S. Akerib; S. Arrenberg; C. N. Bailey; D. Balakishiyeva; L. Baudis; D. A. Bauer; P. L. Brink; T. Bruch; R. Bunker; B. Cabrera; David O. Caldwell; J. Cooley; E. Do Couto E Silva; P. Cushman; M. Daal; F. DeJongh; P. Di Stefano; M. R. Dragowsky; L. Duong; S. Fallows; E. Figueroa-Feliciano; J. Filippini; J. Fox; M. Fritts; S. R. Golwala; J. Hall; R. Hennings-Yeomans; S. A. Hertel; D. Holmgren

We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from weakly interacting massive particles (WIMPs) with masses below ∼10  GeV/c(2). This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9  GeV/c(2) and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.


Physical Review D | 2013

Silicon detector results from the first five-tower run of CDMS II

R. Agnese; Z. Ahmed; A. J. Anderson; S. Arrenberg; D. Balakishiyeva; R. Basu Thakur; D. A. Bauer; A. W. Borgland; D. Brandt; P. L. Brink; T. Bruch; R. Bunker; B. Cabrera; David O. Caldwell; D. G. Cerdeno; H. Chagani; J. Cooley; B. Cornell; C. H. Crewdson; P. Cushman; M. Daal; F. DeJongh; P. Di Stefano; E. Do Couto E Silva; T. Doughty; L. Esteban; S. Fallows; E. Figueroa-Feliciano; J. Filippini; J. Fox

We report results of a search for weakly interacting massive particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II’s full complement of detectors in 2006–2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 kg-days before analysis cuts, with an expected background of ∼1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a recoil energy range of 7–100 keV for an ideal Si detector and a WIMP mass of 10  GeV/c^2. These data set an upper limit of 1.7×10^(-41)  cm^2 on the WIMP-nucleon spin-independent cross section of a 10  GeV/c^2 WIMP. These data exclude parameter space for spin-independent WIMP-nucleon elastic scattering that is relevant to recent searches for low-mass WIMPs.


Physical Review D | 2010

Analysis of the low-energy electron-recoil spectrum of the CDMS experiment

Z. Ahmed; D. S. Akerib; S. Arrenberg; C. N. Bailey; D. Balakishiyeva; L. Baudis; D. A. Bauer; J. Beaty; P. L. Brink; T. Bruch; R. Bunker; B. Cabrera; David O. Caldwell; J. Cooley; P. Cushman; F. DeJongh; M. R. Dragowsky; L. Duong; E. Figueroa-Feliciano; J. Filippini; M. Fritts; S. R. Golwala; D. R. Grant; J. Hall; R. Hennings-Yeomans; S. A. Hertel; D. Holmgren; L. Hsu; M. E. Huber; O. Kamaev

We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the observed counting rate and possible background sources in the energy range of 2–8.5 keV. We find no significant excess of a peaked contribution to the total counting rate above the background model, and compare this observation to the recent DAMA results. In the framework of a conversion of a dark matter particle into electromagnetic energy, our 90% confidence level upper limit of 0.246  events/kg/day at 3.15 keV is lower than the total rate above background observed by DAMA. In absence of any specific particle physics model to provide the scaling in cross section between NaI and Ge, we assume a Z2 scaling. With this assumption the observed rate in DAMA remains higher than the upper limit in CDMS. Under the conservative assumption that the modulation amplitude is 6% of the total rate we obtain upper limits on the modulation amplitude a factor of ~2 lower than observed by DAMA, constraining some possible interpretations of this modulation.


Physical Review D | 2011

Search for inelastic dark matter with the CDMS II experiment

Z. Ahmed; D. S. Akerib; S. Arrenberg; C. N. Bailey; D. Balakishiyeva; L. Baudis; D. A. Bauer; P. L. Brink; T. Bruch; R. Bunker; B. Cabrera; David O. Caldwell; J. Cooley; E. Do Couto E Silva; P. Cushman; M. Daal; F. DeJongh; P. Di Stefano; M. R. Dragowsky; L. Duong; S. Fallows; E. Figueroa-Feliciano; J. Filippini; J. Fox; M. Fritts; S. R. Golwala; J. Hall; R. Hennings-Yeomans; S. A. Hertel; D. Holmgren

Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events, the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10–100 keV.


Szczerbinska, Barbara & Babu, Kaladi & Balantekin, Baha & Dutta, Bhaskar & Mohapatra, Rabindra N. (Eds.). (2013). Workshop on dark matter, unification and neutrino physics : CETUP* 2012, South Dakota, USA, 10 July-01 August 2012. Melville, N.Y.: American Institute of Physics, pp. 129-135, AIP conference proceedings(1534) | 2013

SuperCDMS status from Soudan and plans for SNOLab

J. Sander; Z. Ahmed; A. J. Anderson; S. Arrenberg; D. Balakishiyeva; R.B. Thakur; D. A. Bauer; D. Brandt; P. L. Brink; R. Bunker; B. Cabrera; David O. Caldwell; D. G. Cerdeno; H. Chagani; J. Cooley; B. Cornell; C. H. Crewdson; P. Cushman; M. Daal; P. Di Stefano; E. Do Couto E Silva; T. Doughty; L. Esteban; S. Fallows; E. Figueroa-Feliciano; J. Fox; M. Fritts; G. Godfrey; S. R. Golwala; J. Hall

Matter, as we know it, makes up less than 5% of the Universe. Various astrophysical observations have confirmed that one quarter of the Universe and most of the matter content in the Universe is made up of Dark Matter. The nature of Dark Matter is yet to be discovered and is one of the biggest questions in Physics. Particle Physics combined with astrophysical measurements of the abundance gives rise to a Dark Matter candidate called Weakly Interacting Massive Particle (WIMP). The low density of WIMPs in the galaxies and the extremely weak nature of the interaction with ordinary matter make detection of the WIMP an extraordinarily challenging task, with abundant fakes from various radioactive and cosmogenic backgrounds with much stronger electromagnetic interaction. The extremely weak nature of the WIMP interaction dictates detectors that have extremely low naturally occurring radioactive background, a large active volume (mass) of sensitive detector material to maximize statistics, a highly efficient detector based rejection mechanism for the dominant electromagnetic background and sophisticated analysis techniques to reject any residual background. This paper describes the status of the SuperCDMS experiment.


THE THIRTEENTH INTERNATIONAL WORKSHOP ON LOW TEMPERATURE DETECTORS—LTD13 | 2009

SuperCDMS Detector Fabrication Advances

P. L. Brink; Z. Alimed; D. S. Akerib; C. N. Bailey; D. Balakishiyeva; D. A. Bauer; J. Beaty; R. Bunker; B. Cabrera; D. O. Caldweir; J. Cooley; E. Do Couto E Silva; P. Cushman; M. Daal; F. DeJongh; M. R. Dragowsky; L. Duong; E. Figueroa-Feliciano; J. P. Filippini; M. Fritts; S. R. Golwala; D. R. Grant; J. Half; R. Hennings-Yeomans; S. Herte; A. Hojem; D. Holmgren; L. Hsu; M. E. Huber; K. D. Irwin

For its dark matter search the SuperCDMS collaboration has developed new Ge detectors using the same athermal phonon sensors and ionization measurement technology of CDMS II but with larger mass, superior sensor performance and increased fabrication efficiency. The improvements in fabrication are described, a comparison of CDMS II and SuperCDMS detector production yield is reported, and future scalability addressed.


Journal of Low Temperature Physics | 2012

Simulations of noise in phase-separated transition-edge sensors for superCDMS

A. J. Anderson; S. W. Leman; M. Pyle; E. Figueroa-Feliciano; K. A. McCarthy; T. Doughty; M. Cherry; B. A. Young

We briefly review a simple model of superconducting-normal phase-separation in transition-edge sensors (TESs) in the SuperCDMS experiment. After discussing some design considerations relevant to the TESs in the experiment, we study noise sources in both the phase-separated and phase-uniform cases. Such simulations will be valuable for optimizing the critical temperature and TES length of future SuperCDMS detectors.


Journal of Low Temperature Physics | 2012

Comparison of CDMS [100] and [111] Oriented Germanium Detectors

S. W. Leman; S. A. Hertel; P. Kim; B. Cabrera; E. Do Couto E Silva; E. Figueroa-Feliciano; K. A. McCarthy; R. Resch; B. Sadoulet; K. M. Sundqvist

The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3″ diameter × 1″ thick target masses as particle detectors. The target is instrumented with both phonon and ionization sensors and comparison of energy in each channel provides event-by-event classification of electron and nuclear recoils. Fiducial volume is determined by the ability to obtain good phonon and ionization signal at a particular location. Due to electronic band structure in germanium, electron mass is described by an anisotropic tensor with heavy mass aligned along the symmetry axis defined by the [111] Miller index (L valley), resulting in large lateral component to the transport. The spatial distribution of electrons varies significantly for detectors which have their longitudinal axis orientations described by either the [100] or [111] Miller indices. Electric fields with large fringing component at high detector radius also affect the spatial distribution of electrons and holes. Both effects are studied in a 3 dimensional Monte Carlo and the impact on fiducial volume is discussed.


Proceedings of SPIE | 2010

Progress on the Micro-X sounding rocket x-ray telescope: completion of flight hardware

P. Wikus; Joseph S. Adams; R. Baker; Simon R. Bandler; W. Brys; Daniel Dewey; W. B. Doriese; Megan E. Eckart; E. Figueroa-Feliciano; R. Goeke; R. Hamersma; G. C. Hilton; Una Hwang; K. D. Irwin; R. L. Kelley; Caroline A. Kilbourne; S. W. Leman; D. McCammon; Takashi Okajima; R. H. O'Neal; F. S. Porter; Carl D. Reintsema; J. M. Rutherford; Peter J. Serlemitsos; T. Saab; Kosuke Sato; Yang Soong; Sarah N. Trowbridge

Micro-X is a rocket-borne X-ray telescope which will use an array of Transition Edge Sensor (TES) microcalorimeters to obtain high resolution soft X-ray spectra of extended astronomical sources. The microcalorimeter array consists of 128 pixels with a size of 590 μm × 590 μm each. The TESs are read out with a time-division Superconducting Quantum Interference Device (SQUID) multiplexing system. The instruments front end assembly, which contains the microcalorimeter array and two SQUID amplification stages, is located at the focal point of a conically approximated Wolter mirror with a focal length of 2100 mm and a point spread function of 2.4 arcmin half-power diameter. The telescopes effective area amounts to ~ 300 cm2 at 1 keV. The TES array is cooled with an Adiabatic Demagnetization Refrigerator. The first flight of Micro-X is scheduled for 2011, and will likely target a Si knot in the Puppis A supernova remnant. The time available for the observation above an altitude of 160 km will be in excess of 300 seconds. The design, manufacturing and assembly of the flight hardware has recently been completed, and system testing is underway. We describe the final design of the Micro-X instrument, and report on the overall status of the project.

Collaboration


Dive into the S. W. Leman's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

P. L. Brink

SLAC National Accelerator Laboratory

View shared research outputs
Top Co-Authors

Avatar

P. Cushman

University of Minnesota

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J. Cooley

Southern Methodist University

View shared research outputs
Top Co-Authors

Avatar

E. Do Couto E Silva

SLAC National Accelerator Laboratory

View shared research outputs
Top Co-Authors

Avatar

R. Bunker

University of California

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge