Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Said A. Hassan is active.

Publication


Featured researches published by Said A. Hassan.


Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2011

Three different spectrophotometric methods manipulating ratio spectra for determination of binary mixture of Amlodipine and Atorvastatin.

Hany W. Darwish; Said A. Hassan; Maissa Y. Salem; Badr A. El-Zeiny

Three simple, specific, accurate and precise spectrophotometric methods manipulating ratio spectra are developed for the simultaneous determination of Amlodipine besylate (AM) and Atorvastatin calcium (AT) in tablet dosage forms. The first method is first derivative of the ratio spectra ((1)DD), the second is ratio subtraction and the third is the method of mean centering of ratio spectra. The calibration curve is linear over the concentration range of 3-40 and 8-32 μg/ml for AM and AT, respectively. These methods are tested by analyzing synthetic mixtures of the above drugs and they are applied to commercial pharmaceutical preparation of the subjected drugs. Standard deviation is <1.5 in the assay of raw materials and tablets. Methods are validated as per ICH guidelines and accuracy, precision, repeatability and robustness are found to be within the acceptable limit.


Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2013

Three different methods for determination of binary mixture of Amlodipine and Atorvastatin using dual wavelength spectrophotometry.

Hany W. Darwish; Said A. Hassan; Maissa Y. Salem; Badr A. El-Zeany

Three simple, specific, accurate and precise spectrophotometric methods depending on the proper selection of two wavelengths are developed for the simultaneous determination of Amlodipine besylate (AML) and Atorvastatin calcium (ATV) in tablet dosage forms. The first method is the new Ratio Difference method, the second method is the Bivariate method and the third one is the Absorbance Ratio method. The calibration curve is linear over the concentration range of 4-40 and 8-32 μg/mL for AML and ATV, respectively. These methods are tested by analyzing synthetic mixtures of the above drugs and they are applied to commercial pharmaceutical preparation of the subjected drugs. Methods are validated according to the ICH guidelines and accuracy, precision, repeatability and robustness are found to be within the acceptable limit. The mathematical explanation of the procedures is illustrated.


Simulation Modelling Practice and Theory | 2010

Practical simulation application: Evaluation of process control parameters in Twisted-Pair Cables manufacturing system

Amr Mahfouz; Said A. Hassan; Amr Arisha

Intensive competition and rapid technology development of Twisted-Pair Cables (TPC) industry have left no room for competing manufacturers to harbour system inefficiencies. TPC are used in various communication and networks hardware applications; their manufacturing facilities face many challenges including various product configurations with different equipment settings, different product flows and Work in Process (WIP) space limitations. The quest for internal efficiency and external effectiveness forces companies to align their internal settings and resources with external requirements/orders, or in different words, significant factors must be set appropriately and identified prior to manufacturing processes. Integrated definition models (IDEF0, IDEF3) in conjunction with a simulation model and a design of experiments (DOE) have been developed to characterize the TPC production system, identify the significant process parameters and examine various production setting scenarios aiming to get the best product flow time.


Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2013

Comparative study between derivative spectrophotometry and multivariate calibration as analytical tools applied for the simultaneous quantitation of Amlodipine, Valsartan and Hydrochlorothiazide.

Hany W. Darwish; Said A. Hassan; Maissa Y. Salem; Badr A. El-Zeany

Four simple, accurate and specific methods were developed and validated for the simultaneous estimation of Amlodipine (AML), Valsartan (VAL) and Hydrochlorothiazide (HCT) in commercial tablets. The derivative spectrophotometric methods include Derivative Ratio Zero Crossing (DRZC) and Double Divisor Ratio Spectra-Derivative Spectrophotometry (DDRS-DS) methods, while the multivariate calibrations used are Principal Component Regression (PCR) and Partial Least Squares (PLSs). The proposed methods were applied successfully in the determination of the drugs in laboratory-prepared mixtures and in commercial pharmaceutical preparations. The validity of the proposed methods was assessed using the standard addition technique. The linearity of the proposed methods is investigated in the range of 2-32, 4-44 and 2-20 μg/mL for AML, VAL and HCT, respectively.


Journal of Chromatography B | 2016

Development and validation of LC–MS/MS assay for the simultaneous determination of methotrexate, 6-mercaptopurine and its active metabolite 6-thioguanine in plasma of children with acute lymphoblastic leukemia: Correlation with genetic polymorphism

Medhat A. Al-Ghobashy; Said A. Hassan; Doaa H. Abdelaziz; Noha M. Elhosseiny; Nirmeen A. Sabry; Ahmed S. Attia; Manal H. El-Sayed

Individualized therapy is a recent approach aiming to specify dosage regimen for each patient according to its genetic state. Cancer chemotherapy requires continuous monitoring of the plasma concentration levels of active forms of cytotoxic drugs and subsequent dose adjustment. In order to attain optimum therapeutic efficacy, correlation to pharmacogenetics data is crucial. In this study, a specific, accurate and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) has been developed for determination of methotrexate (MTX), 6-mercaptopurine (MP) and its metabolite 6-thioguanine nucleotide (TG) in human plasma. Based on the basic character of the studied compounds, solid phase extraction using a strong cation exchanger was found the optimum approach to achieve good extraction recovery. Chromatographic separation was carried out using RP-HPLC and isocratic elution by acetonitrile: 0.1% aqueous formic acid (85:15v/v) with a flow rate of 0.8mL/min at 40°C. The detection was performed by tandem mass spectrometry in MRM mode via electrospray ionization source in positive ionization mode. Analysis was carried out within 1.0min over a concentration range of 6.25-200.00ng/mL for the studied analytes. Validation was carried out according to FDA guidelines for bioanalytical method validation and satisfactory results were obtained. The applicability of the assay for the monitoring of the MTX, MP and TG and subsequent application to personalized therapy was demonstrated in a clinical study on children with acute lymphoblastic leukemia (ALL). Results confirmed the need for implementation of reliable analysis tools for therapeutic dose adjustment.


International Journal of Spectroscopy | 2013

Sequential Spectrophotometric Method for the Simultaneous Determination of Amlodipine, Valsartan, and Hydrochlorothiazide in Coformulated Tablets

Hany W. Darwish; Said A. Hassan; Maissa Y. Salem; Badr A. El-Zeany

A new, simple and specific spectrophotometric method was developed and validated in accordance with ICH guidelines for the simultaneous estimation of Amlodipine (AML), Valsartan (VAL), and Hydrochlorothiazide (HCT) in their ternary mixture. In this method three techniques were used, namely, direct spectrophotometry, ratio subtraction, and isoabsorptive point. Amlodipine (AML) was first determined by direct spectrophotometry and then ratio subtraction was applied to remove the AML spectrum from the mixture spectrum. Hydrochlorothiazide (HCT) could then be determined directly without interference from Valsartan (VAL) which could be determined using the isoabsorptive point theory. The calibration curve is linear over the concentration ranges of 4–32, 4–44 and 6–20 μg/mL for AML, VAL, and HCT, respectively. This method was tested by analyzing synthetic mixtures of the above drugs and was successfully applied to commercial pharmaceutical preparation of the drugs, where the standard deviation is <2 in the assay of raw materials and tablets. The method was validated according to the ICH guidelines and accuracy, precision, repeatability, and robustness were found to be within the acceptable limits.


Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2014

Different approaches in Partial Least Squares and Artificial Neural Network models applied for the analysis of a ternary mixture of Amlodipine, Valsartan and Hydrochlorothiazide.

Hany W. Darwish; Said A. Hassan; Maissa Y. Salem; Badr A. El-Zeany

Different chemometric models were applied for the quantitative analysis of Amlodipine (AML), Valsartan (VAL) and Hydrochlorothiazide (HCT) in ternary mixture, namely, Partial Least Squares (PLS) as traditional chemometric model and Artificial Neural Networks (ANN) as advanced model. PLS and ANN were applied with and without variable selection procedure (Genetic Algorithm GA) and data compression procedure (Principal Component Analysis PCA). The chemometric methods applied are PLS-1, GA-PLS, ANN, GA-ANN and PCA-ANN. The methods were used for the quantitative analysis of the drugs in raw materials and pharmaceutical dosage form via handling the UV spectral data. A 3-factor 5-level experimental design was established resulting in 25 mixtures containing different ratios of the drugs. Fifteen mixtures were used as a calibration set and the other ten mixtures were used as validation set to validate the prediction ability of the suggested methods. The validity of the proposed methods was assessed using the standard addition technique.


Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2015

Continuous Wavelet Transform, a powerful alternative to Derivative Spectrophotometry in analysis of binary and ternary mixtures: A comparative study

Eman S. Elzanfaly; Said A. Hassan; Maissa Y. Salem; Badr A. El-Zeany

A comparative study was established between two signal processing techniques showing the theoretical algorithm for each method and making a comparison between them to indicate the advantages and limitations. The methods under study are Numerical Differentiation (ND) and Continuous Wavelet Transform (CWT). These methods were studied as spectrophotometric resolution tools for simultaneous analysis of binary and ternary mixtures. To present the comparison, the two methods were applied for the resolution of Bisoprolol (BIS) and Hydrochlorothiazide (HCT) in their binary mixture and for the analysis of Amlodipine (AML), Aliskiren (ALI) and Hydrochlorothiazide (HCT) as an example for ternary mixtures. By comparing the results in laboratory prepared mixtures, it was proven that CWT technique is more efficient and advantageous in analysis of mixtures with severe overlapped spectra than ND. The CWT was applied for quantitative determination of the drugs in their pharmaceutical formulations and validated according to the ICH guidelines where accuracy, precision, repeatability and robustness were found to be within the acceptable limit.


Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2015

Different signal processing techniques of ratio spectra for spectrophotometric resolution of binary mixture of bisoprolol and hydrochlorothiazide; a comparative study

Eman S. Elzanfaly; Said A. Hassan; Maissa Y. Salem; Badr A. El-Zeany

Five signal processing techniques were applied to ratio spectra for quantitative determination of bisoprolol (BIS) and hydrochlorothiazide (HCT) in their binary mixture. The proposed techniques are Numerical Differentiation of Ratio Spectra (ND-RS), Savitsky-Golay of Ratio Spectra (SG-RS), Continuous Wavelet Transform of Ratio Spectra (CWT-RS), Mean Centering of Ratio Spectra (MC-RS) and Discrete Fourier Transform of Ratio Spectra (DFT-RS). The linearity of the proposed methods was investigated in the range of 2-40 and 1-22 μg/mL for BIS and HCT, respectively. The proposed methods were applied successfully for the determination of the drugs in laboratory prepared mixtures and in commercial pharmaceutical preparations and standard deviation was less than 1.5. The five signal processing techniques were compared to each other and validated according to the ICH guidelines and accuracy, precision, repeatability and robustness were found to be within the acceptable limit.


Acta Pharmaceutica | 2016

Development and validation of HPLC and CE methods for simultaneous determination of amlodipine and atorvastatin in the presence of their acidic degradation products in tablets

Said A. Hassan; Eman S. Elzanfaly; Salem Badr A. El-Zeany; Maissa Y. Salem

Abstract Two methods were developed for separation and quantitation of amlodipine (AML) and atorvastatin (ATV) in the presence of their acidic degradation products. The first method was a simple isocratic RP-HPLC method while the second was capillary electrophoresis (CE). Degradation products were obtained by acidic hydrolysis of the two drugs and their structures were elucidated for the first time by IR and MS spectra. Degradation products did not interfere with the determination of either drug and the assays were therefore stability-indicating. The linearity of the proposed methods was established over the ranges 1-50 μg mL-1 for AML and ATV in the HPLC method and in the range of 3-50 and 4-50 μg mL-1 for AML and ATV, respectively, in the CE method. The proposed methods were validated according to ICH guidelines. The methods were successfully applied to estimation of AML and ATV in combined tablets.

Collaboration


Dive into the Said A. Hassan's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge