Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Salih Hattapoğlu is active.

Publication


Featured researches published by Salih Hattapoğlu.


Pediatric Radiology | 2015

Acoustic radiation force impulse (ARFI) elastography for detection of renal damage in children

Cemil Göya; Cihad Hamidi; Aydın Ece; Mehmet Hanifi Okur; Bekir Tasdemir; Mehmet Güli Çetinçakmak; Salih Hattapoğlu; Memik Teke; Cahit Şahin

BackgroundAcoustic radiation force impulse (ARFI) imaging is a promising method for noninvasive evaluation of the renal parenchyma.ObjectiveTo investigate the contribution of ARFI quantitative US elastography for the detection of renal damage in kidneys with and without vesicoureteral reflux (VUR).Materials and methodsOne hundred seventy-six kidneys of 88 children (46 male, 42 female) who had been referred for voiding cystourethrography and 20 healthy controls were prospectively investigated. Patients were assessed according to severity of renal damage on dimercaptosuccinic acid (DMSA) scintigraphy. Ninety-eight age- and gender-matched healthy children constituted the control group. Quantitative shear wave velocity (SWV) measurements were performed in the upper and lower poles and in the interpolar region of each kidney. DMSA scintigraphy was performed in 62 children (124 kidneys). Comparisons of SWV values of kidneys with and without renal damage and/or VUR were done.ResultsSignificantly higher SWV values were found in non-damaged kidneys. Severely damaged kidneys had the lowest SWV values (P < 0.001). High-grade (grade V-IV) refluxing kidneys had the lowest SWV values, while non-refluxing kidneys had the highest values (P < 0.05). Significant negative correlations were found between the mean quantitative US elastography values and DMSA scarring score (r = −0.788, P < 0.001) and VUR grade (r = −0.634, P < 0.001). SWV values of the control kidneys were significantly higher than those of damaged kidneys (P < 0.05).ConclusionOur findings suggest decreasing SWV of renal units with increasing grades of vesicoureteric reflux, increasing DMSA-assessed renal damage and decreasing DMSA-assessed differential function.


American Journal of Roentgenology | 2015

Acoustic Radiation Force Impulse Imaging for Evaluation of Renal Parenchyma Elasticity in Diabetic Nephropathy

Cemil Göya; Faruk Kılınç; Cihad Hamidi; Alpaslan Yavuz; Yasar Yildirim; Mehmet Güli Çetinçakmak; Salih Hattapoğlu

OBJECTIVE. The goal of this study is to evaluate the changes in the elasticity of the renal parenchyma in diabetic nephropathy using acoustic radiation force impulse imaging. SUBJECTS AND METHODS. The study included 281 healthy volunteers and 114 patients with diabetic nephropathy. In healthy volunteers, the kidney elasticity was assessed quantitatively by measuring the shear-wave velocity using acoustic radiation force impulse imaging based on age, body mass index, and sex. The changes in the renal elasticity were compared between the different stages of diabetic nephropathy and the healthy control group. RESULTS. In healthy volunteers, there was a statistically significant correlation between the shear-wave velocity values and age and sex. The shear-wave velocity values for the kidneys were 2.87, 3.14, 2.95, 2.68, and 2.55 m/s in patients with stage 1, 2, 3, 4, and 5 diabetic nephropathy, respectively, compared with 2.35 m/s for healthy control subjects. Acoustic radiation force impulse imaging was able to distinguish between the different diabetic nephropathy stages (except for stage 5) in the kidneys. The threshold value for predicting diabetic nephropathy was 2.43 m/s (sensitivity, 84.1%; specificity, 67.3%; positive predictive value, 93.1%; negative predictive value 50.8%; accuracy, 72.1%; positive likelihood ratio, 2.5; and negative likelihood ratio, 0.23). CONCLUSION. Acoustic radiation force impulse imaging could be used for the evaluation of the renal elasticity changes that are due to secondary structural and functional changes in diabetic nephropathy.


Journal of Ultrasound in Medicine | 2014

Use of Acoustic Radiation Force Impulse Elastography to Diagnose Acute Pancreatitis at Hospital Admission Comparison With Sonography and Computed Tomography

Cemil Göya; Cihad Hamidi; Salih Hattapoğlu; Mehmet Güli Çetinçakmak; Memik Teke; Mehmet Serdar Degirmenci; Muhsin Kaya; Aslan Bilici

To compare the diagnostic success rate of acoustic radiation force impulse (ARFI) elastography with those of sonography and computed tomography (CT) for acute pancreatitis at hospital admission.


Balkan Medical Journal | 2015

The Role of Apparent Diffusion Coefficient Quantification in Differentiating Benign and Malignant Renal Masses by 3 Tesla Magnetic Resonance Imaging.

Cemil Göya; Cihad Hamidi; Yaşar Bozkurt; Alpaslan Yavuz; Suzan Kuday; Hatice Gümüş; Gül Türkcü; Salih Hattapoğlu; Aslan Bilici

BACKGROUND Diffusion-weighted magnetic resonance imaging (DWI) is a widely-accepted diagnostic modality whose efficacy has been investigated by numerous past studies in the differentiation of malignant lesions from benign entities. AIMS The aim of this study was to evaluate the efficiency of diffusion-weighted magnetic resonance imaging in the characterization of renal lesions. STUDY DESIGN Diagnostic accuracy study. METHODS A total of 137 patients with renal lesions were included in this study. The median apparent diffusion coefficient (ADC) values as well as the b 800 and b 1600 signal intensities of normal kidneys, solid components of mixed renal masses, and total cystic lesions were evaluated. RESULTS There were significant differences between the ADC values of lesions and normal renal parenchyma, and between the ADC values of benign and malignant renal lesions on DWIs at b values of 800 and 1600 s/mm(2) (p<0.001 and p<0.001, respectively). There were significant differences between the ADC values of Bosniak Category 1 and 2 cysts and the ADC values of Bosniak Category 1 and 3 cysts on DWIs at b values of 800 s/mm(2) (p<0.001) and 1600 s/mm(2) (p<0.001). A cutoff value of 1.902 × 10(-3) mm(2)/s for the ADC with a b value of 800 s/mm(2) provided 88% sensitivity and 96% specificity for differentiation between benign and malignant renal lesions. A cutoff value of 1.623 × 10(-3) mm(2)/s for the ADC with a b value of 1600 s/mm(2) provided 79% sensitivity and 96% specificity (p<0.001) for the differentiation between benign and malignant renal lesions. CONCLUSION Accurate assessment of renal masses is important for determining the necessity for surgical intervention. DWI provides additional value by differentiating benign from malignant renal tumors and can be added to routine kidney MRI protocols.


Journal of Ultrasound in Medicine | 2015

Combination of Virtual Touch Tissue Imaging and Virtual Touch Tissue Quantification for Differential Diagnosis of Breast Lesions

Memik Teke; Cemil Göya; Fatma Teke; Ömer Uslukaya; Cihad Hamidi; Mehmet Güli Çetinçakmak; Salih Hattapoğlu; Bircan Alan; Guven Tekbas

Breast cancer is the second leading cause of death from cancer in women, and early detection is the key to successful treatment. Unfortunately, even with technological advances, the specificity of imaging modalities is still low. Therefore, we evaluated the value of a newly developed noninvasive technique, acoustic radiation force impulse imaging, for differentiating benign versus malignant breast lesions.


Surgical and Radiologic Anatomy | 2013

Display with 64-detector MDCT angiography of cerebral vascular variations

Cihad Hamidi; Yaşar Bükte; Salih Hattapoğlu; Faysal Ekici; Guven Tekbas; Hakan Önder; Hatice Gümüş; Aslan Bilici

PurposeThe aim of this study was to assess the cerebral variations and observe their frequency in the patients who have undergone angiographies with the state of the art 64-slice multidetector computed tomography (MDCT) angiography technique due to various reasons.Methods500 patients (253 women, 247 men) who had CT scan in the period of April 2008 to March 2010 at Dicle University Medicine Faculty Hospital Radiology Unit were surveyed in this study. Patients who had CT scan with brain CT angio protocol were evaluated using multiplanar, maximum intensity projection (MIP) and volume rendering (VR) images in work station.Results773 variations were totally detected among 500 patients. Variations were categorized as Willis polygon, fenestration and other variations. Frequent variations were detected at Willis polygon and posterior communicating artery (PCOA) hypoplasia was detected as the prevalent variation.ConclusionsIn the present study, we have demonstrated that cerebral vascular variations are frequent and that these variations can be detected in a non-invasive manner using the MDCT angiography. The results obtained from our study may serve as preoperative guidelines for the units performing surgical procedures.


Korean Journal of Radiology | 2016

Assessment of Placental Stiffness Using Acoustic Radiation Force Impulse Elastography in Pregnant Women with Fetal Anomalies

Bircan Alan; Cemil Göya; Senem Yaman Tunç; Memik Teke; Salih Hattapoğlu

Objective We aimed to evaluate placental stiffness measured by acoustic radiation force impulse (ARFI) elastography in pregnant women in the second trimester with a normal fetus versus those with structural anomalies and non-structural findings. Materials and Methods Forty pregnant women carrying a fetus with structural anomalies diagnosed sonographically at 18–28 weeks of gestation comprised the study group. The control group consisted of 34 healthy pregnant women with a sonographically normal fetus at a similar gestational age. Placental shear wave velocity (SWV) was measured by ARFI elastography and compared between the two groups. Structural anomalies and non-structural findings were scored based on sonographic markers. Placental stiffness measurements were compared among fetus anomaly categories. Doppler parameters of umbilical and uterine arteries were compared with placental SWV measurements. Results All placental SWV measurements, including minimum SWV, maximum SWV, and mean SWV were significantly higher in the study group than the control group ([0.86 ± 0.2, 0.74 ± 0.1; p < 0.001], [1.89 ± 0.7, 1.59 ± 0.5; p = 0.04], and [1.26 ± 0.4, 1.09 ± 0.2; p = 0.01]), respectively. Conclusion Placental stiffness evaluated by ARFI elastography during the second trimester in pregnant women with fetuses with congenital structural anomalies is higher than that of pregnant women with normal fetuses.


Ultrasonic Imaging | 2015

The Role of Acoustic Radiation Force Impulse Elastography in the Differentiation of Infectious and Neoplastic Liver Lesions.

Cemil Göya; Cihad Hamidi; Alpaslan Yavuz; Salih Hattapoğlu; Ömer Uslukaya; Mehmet Güli Çetinçakmak; Memik Teke; Zuhat Urakci

We aimed to evaluate the effectiveness of acoustic radiation force impulse (ARFI) elastography in differentiating between hepatic lesions. The prospective study included 117 patients with liver masses. Shear wave velocity (SWV) values for lesions were determined by ARFI imaging and compared statistically. The difference between SWV values for benign and malignant hepatic masses was significant (p < 0.01). The threshold SWV value for malignant hepatic lesions was established at 2.52 m/s, and the sensitivity and specificity of this cut-off value were 97% and 66%, respectively. We concluded that ARFI elastography provides supplementary data that aid in the differential diagnosis of liver masses.


Radiologia Medica | 2015

Imaging features of cerebral and spinal cystic echinococcosis

Memik Teke; Cüneyt Göçmez; Cihad Hamidi; Ercan Gündüz; Cemil Göya; Mehmet Güli Çetinçakmak; Salih Hattapoğlu; Mehmet Sedat Durmaz

PurposeThe main objective of this study was to describe the characteristic imaging features of cerebral and spinal hydatid disease (HD) in magnetic resonance imaging (MRI) and computed tomography (CT) in order to provide more effective differential diagnoses in endemic regions. We also aimed to use MRI and CT to evaluate whether the World Health Organization’s (WHO) new classification of hepatic cystic echinococcosis (CE) could be used in the classification of cerebral HD.Materials and methodsWe retrospectively reviewed the CT and MR images of 30 patients who were diagnosed with cerebral and spinal HD between 1990 and 2014. The imaging findings were noted. All hydatid cysts were classified according to the WHO classification of hepatic CE, consisting of six types.ResultsThe study group consisted of 49 CEs in 27 patients with cerebral HD and 12 CEs in three patients with spinal HD. Of the cysts, 14 were type CL (cystic lesion), 29 were type CE1, 11 were type CE2 and seven were type CE3. In other words, 54 cysts were in the active group and seven were in the transition group. Most of the cysts were type CL and CE1.ConclusionsEven though characteristic imaging features could be used in the differential diagnosis of HD, sometimes the differentiation of HD from other cystic lesions may be difficult. The use of WHO classification will provide standardisation of uniform treatment modality, as the treatment of HD, according to the stage of the disease, may be surgical or medical.


Journal of Ultrasound in Medicine | 2014

Sonographic Findings of Hepatobiliary Fascioliasis Accompanied by Extrahepatic Expansion and Ectopic Lesions

Memik Teke; Hakan Önder; Mutalip Çiçek; Cihad Hamidi; Cemil Göya; Mehmet Güli Çetinçakmak; Salih Hattapoğlu; Burak Veli Ülger

The aim of the study was to describe the sonographic findings of hepatobiliary fascioliasis with extrahepatic expansion and ectopic lesions.

Collaboration


Dive into the Salih Hattapoğlu's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alpaslan Yavuz

Yüzüncü Yıl University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge