Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sam Aerts is active.

Publication


Featured researches published by Sam Aerts.


Bioelectromagnetics | 2013

Exposure assessment of mobile phone base station radiation in an outdoor environment using sequential surrogate modeling.

Sam Aerts; Dirk Deschrijver; Wout Joseph; Leen Verloock; Francis Goeminne; Luc Martens; Tom Dhaene

Human exposure to background radiofrequency electromagnetic fields (RF-EMF) has been increasing with the introduction of new technologies. There is a definite need for the quantification of RF-EMF exposure but a robust exposure assessment is not yet possible, mainly due to the lack of a fast and efficient measurement procedure. In this article, a new procedure is proposed for accurately mapping the exposure to base station radiation in an outdoor environment based on surrogate modeling and sequential design, an entirely new approach in the domain of dosimetry for human RF exposure. We tested our procedure in an urban area of about 0.04 km(2) for Global System for Mobile Communications (GSM) technology at 900 MHz (GSM900) using a personal exposimeter. Fifty measurement locations were sufficient to obtain a coarse street exposure map, locating regions of high and low exposure; 70 measurement locations were sufficient to characterize the electric field distribution in the area and build an accurate predictive interpolation model. Hence, accurate GSM900 downlink outdoor exposure maps (for use in, e.g., governmental risk communication and epidemiological studies) are developed by combining the proven efficiency of sequential design with the speed of exposimeter measurements and their ease of handling.


Environmental Research | 2013

Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling.

Sam Aerts; Dirk Deschrijver; Leen Verloock; Tom Dhaene; Luc Martens; Wout Joseph

In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information-inside hotspots or in search of them-based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km2. In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96.


Bioelectromagnetics | 2015

A novel method to assess human population exposure induced by a wireless cellular network

Nadège Varsier; David Plets; Yoann Corre; Günter Vermeeren; Wout Joseph; Sam Aerts; Luc Martens; Joe Wiart

This paper presents a new metric to evaluate electromagnetic exposure induced by wireless cellular networks. This metric takes into account the exposure induced by base station antennas as well as exposure induced by wireless devices to evaluate average global exposure of the population in a specific geographical area. The paper first explains the concept and gives the formulation of the Exposure Index (EI). Then, the EI computation is illustrated through simple phone call scenarios (indoor office, in train) and a complete macro urban data long-term evolution scenario showing how, based on simulations, radio-planning predictions, realistic population statistics, user traffic data, and specific absorption rate calculations can be combined to assess the index. Bioelectromagnetics. 36:451-463, 2015.


Health Physics | 2015

On-body calibration and measurements using a personal, distributed exposimeter for wireless fidelity.

Arno Thielens; Sam Agneessens; Hans De Clercq; Jeroen Lecoutere; Leen Verloock; Emmeric Tanghe; Sam Aerts; Robert Puers; Hendrik Rogier; Luc Martens; Wout Joseph

AbstractThis paper describes the design, calibration, and measurements with a personal, distributed exposimeter (PDE) for the on-body detection of radio frequency (RF) electromagnetic fields due to Wireless Fidelity (WiFi) networks. Numerical simulations show that using a combination of two RF nodes placed on the front and back of the body reduces the 50% prediction interval (PI50) on the incident free-space electric-field strength . Median reductions of 10 dB and 9.1 dB are obtained compared to the PI50 of a single antenna placed on the body using a weighted arithmetic and geometric average, respectively. Therefore, a simple PDE topology based on two nodes, which are deployed on opposite sides of the human torso, is applied for calibration and measurements. The PDE is constructed using flexible, dual-polarized textile antennas and wearable electronics, which communicate wirelessly with a Universal Serial Bus (USB) connected receiver and can be unobtrusively integrated into a garment. The calibration of the PDE in an anechoic chamber proves that the PI50 of the measured is reduced to 3.2 dB. To demonstrate the real-life usability of the wireless device, a subject was equipped with the PDE during a walk in the city of Ghent, Belgium. Using a sample frequency of 2 Hz, an average incident power density of 59 nW m−2 was registered in the WiFi frequency band during this walk.


BioMed Research International | 2015

Joint Minimization of Uplink and Downlink Whole-Body Exposure Dose in Indoor Wireless Networks

David Plets; Wout Joseph; Kris Vanhecke; Günter Vermeeren; Joe Wiart; Sam Aerts; Nadège Varsier; Luc Martens

The total whole-body exposure dose in indoor wireless networks is minimized. For the first time, indoor wireless networks are designed and simulated for a minimal exposure dose, where both uplink and downlink are considered. The impact of the minimization is numerically assessed for four scenarios: two WiFi configurations with different throughputs, a Universal Mobile Telecommunications System (UMTS) configuration for phone call traffic, and a Long-Term Evolution (LTE) configuration with a high data rate. Also, the influence of the uplink usage on the total absorbed dose is characterized. Downlink dose reductions of at least 75% are observed when adding more base stations with a lower transmit power. Total dose reductions decrease with increasing uplink usage for WiFi due to the lack of uplink power control but are maintained for LTE and UMTS. Uplink doses become dominant over downlink doses for usages of only a few seconds for WiFi. For UMTS and LTE, an almost continuous uplink usage is required to have a significant effect on the total dose, thanks to the power control mechanism.


Bioelectromagnetics | 2016

Drone based measurement system for radiofrequency exposure assessment.

Wout Joseph; Sam Aerts; Matthias Vandenbossche; Arno Thielens; Luc Martens

For the first time, a method to assess radiofrequency (RF) electromagnetic field (EMF) exposure of the general public in real environments with a true free-space antenna system is presented. Using lightweight electronics and multiple antennas placed on a drone, it is possible to perform exposure measurements. This technique will enable researchers to measure three-dimensional RF-EMF exposure patterns accurately in the future and at locations currently difficult to access. A measurement procedure and appropriate measurement settings have been developed. As an application, outdoor measurements are performed as a function of height up to 60 m for Global System for Mobile Communications (GSM) 900 MHz base station exposure. Bioelectromagnetics. 37:195-199, 2016.


International Journal of Environmental Research and Public Health | 2015

Impact of a small cell on the RF-EMF exposure in a train.

Sam Aerts; David Plets; Arno Thielens; Luc Martens; Wout Joseph

The deployment of a miniature mobile-phone base station or small cell in a train car significantly improves the coverage and the capacity of a mobile network service on the train. However, the impact of the small cell on the passengers’ exposure to radio-frequency electromagnetic fields (RF-EMF) is unknown. In this study, we assessed experimentally the RF-EMF exposure of a mobile-phone user who is either connected to the outdoor macrocell network or to an in-train small cell, while traveling on the train, by means of the absorbed-dose concept, which combines the base station downlink exposure with the mobile-phone uplink exposure. For Global System for Mobile Communications (GSM) technology at 1800 MHz, we found that by connecting to a small cell, the brain exposure of the user could realistically be reduced by a factor 35 and the whole-body exposure by a factor 11.


Radiation Protection Dosimetry | 2014

Assessment and comparison of total RF-EMF exposure in femtocell and macrocell base station scenarios.

Sam Aerts; David Plets; Leen Verloock; Luc Martens; Wout Joseph

The indoor coverage of a mobile service can be drastically improved by deployment of an indoor femtocell base station (FBS). However, the impact of its proximity on the total exposure of the human body to radio-frequency (RF) electromagnetic fields (EMFs) is unknown. Using a framework designed for the combination of near-field and far-field exposure, the authors assessed and compared the RF-EMF exposure of a mobile-phone (MP) user that is either connected to an FBS or a conventional macrocell base station while in an office environment. It is found that, in average macrocell coverage and MP use-time conditions and for Universal Mobile Telecommunications System technology, the total exposure can be reduced by a factor of 20-40 by using an FBS, mostly due to the significant decrease in the output power of the MP. In general, the framework presented in this study can be used for any exposure scenario, featuring any number of technologies, base stations and/or access points, users and duration.


Radiation Protection Dosimetry | 2014

Prediction and comparison of downlink electric-field and uplink localised SAR values for realistic indoor wireless planning

David Plets; Wout Joseph; Sam Aerts; Kris Vanhecke; Günter Vermeeren; Luc Martens

In this paper, for the first time a heuristic network calculator for both whole-body exposure due to indoor base station antennas or access points (downlink exposure) and localised exposure due to the mobile device (uplink exposure) in indoor wireless networks is presented. As an application, three phone call scenarios are investigated (Universal Mobile Telecommunications System (UMTS) macrocell, UMTS femtocell and WiFi voice-over-IP) and compared with respect to the electric-field strength and localised specific absorption rate (SAR) distribution. Prediction models are created and successfully validated with an accuracy of 3 dB. The benefits of the UMTS power control mechanisms are demonstrated. However, dependent on the macrocell connection quality and on the users average phone call connection time, also the macrocell solution might be preferential from an exposure point of view for the considered scenario.


Environmental Research | 2017

Measurements of intermediate-frequency electric and magnetic fields in households

Sam Aerts; Carolina Calderon; Blaž Valič; Myron Maslanyj; Darren Addison; Terry Mee; Cristian Goiceanu; Leen Verloock; Matthias Van den Bossche; Peter Gajšek; Roel Vermeulen; Martin Röösli; Elisabeth Cardis; Luc Martens; Wout Joseph

&NA; Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely‐low‐frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate‐frequency (IF) range (300 Hz to 1 MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real‐life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20 cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6 kHz and 300 kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50 Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20 cm were 41.5 V/m and 2.7 A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non‐Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20 cm and beyond (maximum exposure quotients EQE 1.0 and EQH 0.13). HighlightsSurvey of residential electric and magnetic fields at intermediate frequencies (IF).IF‐EF and ‐MF emitted by 280 household appliances were characterised.Strongest emitters were induction cookers, CFLs, LCD‐TVs, and microwave ovens.No emissions exceeded ICNIRP limits (highest exposure quotient was 1.00).

Collaboration


Dive into the Sam Aerts's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dirk Deschrijver

Research Foundation - Flanders

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge