Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sandrine Fleury-Souverain is active.

Publication


Featured researches published by Sandrine Fleury-Souverain.


Talanta | 2011

Analysis of anticancer drugs: a review.

Susanne Nussbaumer; Pascal Bonnabry; Jean-Luc Veuthey; Sandrine Fleury-Souverain

In the last decades, the number of patients receiving chemotherapy has considerably increased. Given the toxicity of cytotoxic agents to humans (not only for patients but also for healthcare professionals), the development of reliable analytical methods to analyse these compounds became necessary. From the discovery of new substances to patient administration, all pharmaceutical fields are concerned with the analysis of cytotoxic drugs. In this review, the use of methods to analyse cytotoxic agents in various matrices, such as pharmaceutical formulations and biological and environmental samples, is discussed. Thus, an overview of reported analytical methods for the determination of the most commonly used anticancer drugs is given.


Journal of Pharmaceutical and Biomedical Analysis | 2010

Determination of potassium, sodium, calcium and magnesium in total parenteral nutrition formulations by capillary electrophoresis with contactless conductivity detection

Susanne Nussbaumer; Sandrine Fleury-Souverain; Lucie Bouchoud; Serge Rudaz; Pascal Bonnabry; Jean-Luc Veuthey

A simple method based on capillary electrophoresis with a capacitively coupled contactless conductivity detector (CE-C(4)D) was developed for the determination of potassium, sodium, calcium and magnesium in parenteral nutrition formulations. A hydro-organic mixture, consisting of 100 mM Tris-acetate buffer at pH 4.5 and acetonitrile (80:20, v/v), was selected as the background electrolyte. The applied voltage was 30 kV, and sample injection was performed in hydrodynamic mode. All analyses were carried out in a fused silica capillary with an internal diameter of 50 microm and a total length of 64.5 cm. Under these conditions, complete separation between all cations was achieved in less than 4 min. The CE-C(4)D method was validated, and trueness values between 98.6% and 101.8% were obtained with repeatability and intermediate precision values of 0.4-1.3% and 0.8-1.8%, respectively. Therefore, this method was found to be appropriate for controlling potassium, sodium, calcium and magnesium in parenteral nutrition formulations and successfully applied in daily quality control at the Geneva University Hospitals.


Science of The Total Environment | 2016

Dynamics of active pharmaceutical ingredients loads in a Swiss university hospital wastewaters and prediction of the related environmental risk for the aquatic ecosystems.

Silwan Daouk; Nathalie Chèvre; Nathalie Vernaz; Christèle Widmer; Youssef Daali; Sandrine Fleury-Souverain

The wastewater contamination of a Swiss university hospital by active pharmaceutical ingredient (API) residues was evaluated with a three months monitoring campaign at the outlet of the main building. Flow-proportional samples were collected with an automatic refrigerated sampler and analyzed for 15 API, including antibiotics, analgesics, antiepileptic and anti-inflammatory drugs, by using a validated LC-MS/MS method. The metals Gd and Pt were also analyzed using ICP-MS. Measured concentrations were compared to the predicted ones calculated after the drug average consumption data obtained from the hospital pharmacy. The hospital contribution to the total urban load was calculated according to the consumption data obtained from city pharmacies. Lastly, the environmental hazard and risk quotients (RQ) related to the hospital fraction and the total urban consumption were calculated. Median concentrations of the 15 selected compounds were ranging from 0.04 to 675 μg/L, with a mean detection frequency of 84%. The ratio between predicted and measured environmental concentrations (PEC/MEC) has shown a good accuracy for 5 out of 15 compounds, revealing over- and under-estimations of the PEC model. Mean daily loads were ranging between 0.01 and 14.2g/d, with the exception of paracetamol (109.7 g/d). The hospital contribution to the total urban loads varied from 2.1 to 100% according to the compound. While taking into account dilution and removal efficiencies in wastewater treatment plant, only the hospital fraction of the antibiotics ciprofloxacin and sulfamethoxazole showed, respectively, a high (RQ>1) and moderate (RQ>0.1) risk for the aquatic ecosystems. Nevertheless, when considering the total urban consumption, 7 compounds showed potential deleterious effects on aquatic organisms (RQ>1): gabapentin, sulfamethoxazole, ciprofloxacin, piperacillin, ibuprofen, diclofenac and mefenamic acid. In order to reduce inputs of API residues originating from hospitals various solutions can be envisioned. With results of the present study, hospital managers can start handling this important issue.


Journal of Chromatography B | 2009

Validation and long-term evaluation of a modified on-line chiral analytical method for therapeutic drug monitoring of (R,S)-methadone in clinical samples

Nicolas Ansermot; Serge Rudaz; Marlyse Brawand-Amey; Sandrine Fleury-Souverain; Jean-Luc Veuthey; Chin B. Eap

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.


Journal of Oncology Pharmacy Practice | 2014

Determination of the external contamination and cross-contamination by cytotoxic drugs on the surfaces of vials available on the Swiss market

Sandrine Fleury-Souverain; Susanne Nussbaumer; Marc Mattiuzzo; Pascal Bonnabry

Introduction The external contamination and cross-contamination by cytotoxic drugs on the surface (outside and septum) of 133 vials from various manufacturers and available on the Swiss market were evaluated. All of the tested vials contained one of the following active ingredients: cyclophosphamide, cytarabine, doxorubicin, epirubicin, etoposide phosphate, gemcitabine, ifosfamide, irinotecan, methotrexate or vincristine. Methods and materials The validated wiping liquid chromatography-mass spectrometry method used in this study allowed for the simultaneous determination of these 10 cytotoxic drugs in less than 30 min. Results External contamination by cytotoxic drugs was detected on 63% of tested vials (outside and septum). The highest contamination level was observed on etoposide phosphate vials with 1896.66 ng of active ingredient on the outside of the vial. Approximately 20% of the contaminated vials had greater than 10 ng of cytotoxic drugs. Chemical contamination on the septum was detected on 38% of the vials. No contamination or very low levels of cytotoxic drugs, less than 1 ng per vial, were detected on the vials protected by plastic shrink-wrap. Traces of cytotoxic drugs different from the active ingredient were detected on 35% of the tested vials. Conclusion Handling cytotoxic vials with gloves and having a procedure for the decontamination of vials are of the utmost importance for reducing exposure to cytotoxic drugs. Moreover, manufacturers must improve their procedures to provide products free from any contamination.


Journal of Pharmaceutical and Biomedical Analysis | 2009

Determination of suxamethonium in a pharmaceutical formulation by capillary electrophoresis with contactless conductivity detection (CE-C4D)

Susanne Nussbaumer; Sandrine Fleury-Souverain; Serge Rudaz; Pascal Bonnabry; Jean-Luc Veuthey

A simple method based on capillary electrophoresis with a capacitively coupled contactless conductivity detector (CE-C(4)D) was developed for the determination of suxamethonium (SUX) in a pharmaceutical formulation. A hydro-organic mixture, consisting of 100mM Tris-acetate buffer at pH 4.2 and acetonitrile (90:10, v/v), was selected as background electrolyte (BGE). The applied voltage was 30kV, and the sample injection was performed in the hydrodynamic mode. All analyses were carried out in a fused silica capillary with an internal diameter of 50 microm and a total length of 64.5cm. Under these conditions, a complete separation between SUX, sodium ions and the main degradation products (choline) was achieved in less than 4min. The presence of acetonitrile in the BGE allowed a reduction of SUX adsorption on the capillary wall. The CE-C(4)D method was validated, and trueness values between 98.8% and 101.1% were obtained with repeatability and intermediate precision values of 0.7-1.3% and 1.2-1.6%, respectively. Therefore, this method was found appropriate for controlling pharmaceutical formulations containing suxamethonium and degradation products.


Annals of Occupational Hygiene | 2013

Evaluation of Decontamination Efficacy of Cleaning Solutions on Stainless Steel and Glass Surfaces Contaminated by 10 Antineoplastic Agents

Thomas Queruau Lamerie; Susanne Nussbaumer; Bertrand Décaudin; Sandrine Fleury-Souverain; Jean-François Goossens; Pascal Bonnabry; Pascal Odou

OBJECTIVES The handling of antineoplastic agents results in chronic surface contamination that must be minimized and eliminated. This study was designed to assess the potential of several chemical solutions to decontaminate two types of work surfaces that were intentionally contaminated with antineoplastic drugs. METHODS A range of solutions with variable physicochemical properties such as their hydrophilic/hydrophobic balance, oxidizing power, desorption, and solubilization were tested: ultrapure water, isopropyl alcohol, acetone, sodium hypochlorite, and surfactants such as dishwashing liquid (DWL), sodium dodecyl sulfate (SDS), Tween 40, and Span 80. These solutions were tested on 10 antineoplastic drugs: cytarabine, gemcitabine, methotrexate, etoposide phosphate, irinotecan, cyclophosphamide, ifosfamide, doxorubicin, epirubicin, and vincristine. To simulate contaminated surfaces, these molecules (200ng) were deliberately spread onto two types of work surfaces: stainless steel and glass. Recovered by wiping with a specific aqueous solvent (acetonitrile/HCOOH; 20/0.1%) and an absorbent wipe (Whatman 903®), the residual contamination was quantified using high-performance liquid chromatography (HPLC) coupled to mass spectrometry. To compare all tested cleaning solutions, a performance value of effectiveness was determined from contamination residues of the 10 drugs. RESULTS Sodium hypochlorite showed the highest overall effectiveness with 98% contamination removed. Ultrapure water, isopropyl alcohol/water, and acetone were less effective with effectiveness values of 76.8, 80.7, and 40.4%, respectively. Ultrapure water was effective on most hydrophilic molecules (97.1% for cytarabine), while on the other hand, isopropyl alcohol/water (70/30, vol/vol) was effective on the least hydrophilic ones (85.2% for doxorubicin and 87.8% for epirubicin). Acetone had little effect, whatever the type of molecule. Among products containing surfactants, DWL was found effective (91.5%), but its formulation was unknown. Formulations with single surfactant non-ionics (tween 40 and span 80) or anionic (SDS) were also tested. Finally, solutions containing 10(-2) M anionic surfactants and 20% isopropyl alcohol had the highest global effectiveness at around 90%. More precisely, their efficacy was the highest (94.8%) for the most hydrophilic compounds such as cytarabine and around 80.0% for anthracyclines. Finally, the addition of isopropyl alcohol to surfactant solutions enhanced their decontamination efficiency on the least hydrophilic molecules. Measured values from the stainless steel surface were similar to those from the glass one. CONCLUSION This study demonstrates that all decontamination agents reduce antineoplastic contamination on work surfaces, but none removes it totally. Although very effective, sodium hypochlorite cannot be used routinely on stainless steel surfaces. Solutions containing anionic surfactant such as SDS, with a high efficiency/safety ratio, proved most promising in terms of surface decontamination.


Journal of Pharmaceutical and Biomedical Analysis | 2011

Quality control of pharmaceutical formulations containing cisplatin, carboplatin, and oxaliplatin by micellar and microemulsion electrokinetic chromatography (MEKC, MEEKC)

Susanne Nussbaumer; Sandrine Fleury-Souverain; Julie Schappler; Serge Rudaz; Jean-Luc Veuthey; Pascal Bonnabry

A micellar electrokinetic chromatography (MEKC) method was developed for the determination of cisplatin, carboplatin, and oxaliplatin in pharmaceutical formulations. The background electrolyte consisted of a phosphate buffer (pH 7.0; 25 mM) with sodium dodecyl sulfate (80 mM). The applied voltage was 30 kV and the sample injection was performed in the hydrodynamic mode. All analyses were carried out in a fused silica capillary with an internal diameter of 50 μm and a total length of 64.5 cm. The detection of target compounds was performed at 200 nm. Under these conditions, a complete separation of cisplatin, carboplatin and oxaliplatin was achieved in less than 10 min. The MEKC-UV method was validated and trueness values between 99.7% and 100.8% were obtained with repeatability and intermediate precision values of 0.7-1.4% and 1.1-1.7%, respectively for the three drugs. This method was found appropriate for controlling pharmaceutical formulations containing platinum complexes and successfully applied in quality control at the Geneva University Hospitals.


European Journal of Hospital Pharmacy-Science and Practice | 2015

Evaluation of chemical contamination of surfaces during the preparation of chemotherapies in 24 hospital pharmacies

Sandrine Fleury-Souverain; Marc Mattiuzzo; Florence Mehl; Susanne Nussbaumer; Lucie Bouchoud; Ludivine Falaschi; Marianne Gex-Fabry; Serge Rudaz; Farshid Sadeghipour; Pascal Bonnabry

Purpose To evaluate the chemical contamination of surfaces by cytotoxic agents during preparation of injectable chemotherapies in hospital pharmacies. Methods 526 wipe samples collected in 24 Swiss hospital pharmacies were analysed using a validated liquid chromatography–mass spectrometry/mass spectrometry method able to quantify 10 cytotoxic agents: cytarabine, gemcitabine, cyclophosphamide, ifosfamide, methotrexate, etoposide phosphate, irinotecan, doxorubicin, epirubicin and vincristine. Information on chemotherapies produced, equipment and production processes used were collected from all the hospital pharmacies on a voluntary basis in order to investigate their association with contamination rates. Results In two pharmacies, no trace of the 10 cytotoxic agents was detected. Chemical contamination was found in the other 22 hospital pharmacies, with combined total contamination of the 10 cytotoxic agents ranging from 8 ng to more than 41 000 ng per sample. Most contaminated samples came from inside biosafety cabinets, but some came from other clean room areas and logistics rooms. Statistically significant associations were observed between contamination rates and sampling locations, the number of chemotherapies prepared per year and types of cleaning solutions used. Conclusions This study demonstrated that most of the hospital pharmacies tested had some contamination of surfaces by different cytotoxic agents. Even if highest levels of contamination were mainly detected inside biosafety cabinets, technicians were also exposed to cytotoxic agents detected in logistical and storage areas. Protective measures should therefore be maintained or even reinforced in these areas in order to limit technicians’ risks of exposure when handling cytotoxic products.


American Journal of Health-system Pharmacy | 2013

Accuracy of preparation of i.v. medication syringes for anesthesiology

Cyril Stucki; Anna-Maria Sautter; Adriana Wolff; Sandrine Fleury-Souverain; Pascal Bonnabry

PURPOSE The results of a study of the accuracy of i.v. medication preparation by anesthesiologists are presented. METHODS The accuracy of syringe preparation was assessed by analyzing the contents of 500 unused syringes collected after adult and pediatric surgery procedures. The collected syringes contained various i.v. medication formulations representative of different preparation techniques: atracurium 1, 2.5, and 5 μg/mL and fentanyl 10, 20, 25, and 50 μg/mL, which required serial dilution after withdrawal of the drugs from ampuls; thiopental 5, 25, and 50 mg/mL, prepared by diluting reconstituted powdered drug from vials; and lidocaine 10-mg/mL solution, which was withdrawn directly from the ampul into a syringe. Variances between actual and labeled drug concentrations were determined via a validated ultraviolet-visible light spectro-photometry method. RESULTS Overall, 29% of the evaluated syringes were found to contain drug concentrations outside the designated range of acceptability (±10% of the targeted concentration); 18% of preparations deviated from the declared dose by ±20%, 8% deviated by ±50%, and 4% deviated by ±100%. In one instance, the actual drug concentration was at variance with the labeled concentration by >100%. In 4% of cases (n = 20), discrepancies exceeded 100%, suggesting not just imprecision but errors in the preparation process, such as incorrect dilution calculations and selection of the wrong medication vial by the syringe preparer. CONCLUSION Analysis of different i.v. formulations of four medications prepared in syringes by anesthesiologists revealed a high rate of discrepancies between ordered and actual drug concentrations, suggesting a need for increased institutional efforts to prevent errors during the preparation process.

Collaboration


Dive into the Sandrine Fleury-Souverain's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Serge Rudaz

University of Lausanne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge