Sandrine Lévêque-Fort
Centre national de la recherche scientifique
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Sandrine Lévêque-Fort.
Biophysical Journal | 2001
K.C. Benny Lee; Jan Siegel; S.E.D. Webb; Sandrine Lévêque-Fort; M.J. Cole; R. Jones; K. Dowling; M.J. Lever; Paul M. W. French
Conventional analyses of fluorescence lifetime measurements resolve the fluorescence decay profile in terms of discrete exponential components with distinct lifetimes. In complex, heterogeneous biological samples such as tissue, multi-exponential decay functions can appear to provide a better fit to fluorescence decay data than the assumption of a mono-exponential decay, but the assumption of multiple discrete components is essentially arbitrary and is often erroneous. Moreover, interactions, both between fluorophores and with their environment, can result in complex fluorescence decay profiles that represent a continuous distribution of lifetimes. Such continuous distributions have been reported for tryptophan, which is one of the main fluorophores in tissue. This situation is better represented by the stretched-exponential function (StrEF). In this work, we have applied, for the first time to our knowledge, the StrEF to time-domain whole-field fluorescence lifetime imaging (FLIM), yielding both excellent tissue contrast and goodness of fit using data from rat tissue. We note that for many biological samples for which there is no a priori knowledge of multiple discrete exponential fluorescence decay profiles, the StrEF is likely to provide a truer representation of the underlying fluorescence dynamics. Furthermore, fitting to a StrEF significantly decreases the required processing time, compared with a multi-exponential component fit and typically provides improved contrast and signal/noise in the resulting FLIM images. In addition, the stretched-exponential decay model can provide a direct measure of the heterogeneity of the sample, and the resulting heterogeneity map can reveal subtle tissue differences that other models fail to show.
Biophysical Journal | 2002
Klaus Suhling; Jan Siegel; David Phillips; Paul M. W. French; Sandrine Lévêque-Fort; S.E.D. Webb; Daniel M. Davis
An emerging theme in cell biology is that cell surface receptors need to be considered as part of supramolecular complexes of proteins and lipids facilitating specific receptor conformations and distinct distributions, e.g., at the immunological synapse. Thus, a new goal is to develop bioimaging that not only locates proteins in live cells but can also probe their environment. Such a technique is demonstrated here using fluorescence lifetime imaging of green fluorescent protein (GFP). We first show, by time-correlated single-photon counting, that the fluorescence decay of GFP depends on the local refractive index. This is in agreement with the Strickler Berg formula, relating the Einstein A and B coefficients for absorption and spontaneous emission in molecules. We then quantitatively image, by wide-field time-gated fluorescence lifetime imaging, the refractive index of the environment of GFP. This novel approach paves the way for imaging the biophysical environment of specific GFP-tagged proteins in live cells.
Applied Optics | 2003
Jan Siegel; Daniel S. Elson; S.E.D. Webb; K.C. Benny Lee; Alexis Vlandas; Giovanni L. Gambaruto; Sandrine Lévêque-Fort; M. John Lever; Paul J. Tadrous; Gordon Stamp; Andrew L. Wallace; Ann Sandison; Tim F. Watson; Fernando Alvarez; Paul M. W. French
We have applied fluorescence lifetime imaging (FLIM) to the autofluorescence of different kinds of biological tissue in vitro, including animal tissue sections and knee joints as well as human teeth, obtaining two-dimensional maps with functional contrast. We find that fluorescence decay profiles of biological tissue are well described by the stretched exponential function (StrEF), which can represent the complex nature of tissue. The StrEF yields a continuous distribution of fluorescence lifetimes, which can be extracted with an inverse Laplace transformation, and additional information is provided by the width of the distribution. Our experimental results from FLIM microscopy in combination with the StrEF analysis indicate that this technique is ready for clinical deployment, including portability that is through the use of a compact picosecond diode laser as the excitation source. The results obtained with our FLIM endoscope successfully demonstrated the viability of this modality, though they need further optimization. We expect a custom-designed endoscope with optimized illumination and detection efficiencies to provide significantly improved performance.
Optics Letters | 2004
Klaus Suhling; Jan Siegel; Peter M. P. Lanigan; Sandrine Lévêque-Fort; S.E.D. Webb; David Phillips; Daniel M. Davis; Paul M. W. French
We have developed a wide-field time-resolved imaging system to image quantitatively both the fluorescence lifetime and the rotational correlation time of a fluorophore. Using a polarization-resolved imager, we simultaneously image orthogonal polarization components of the fluorescence emission onto a time-gated intensified CCD. We demonstrate imaging of solvent viscosity variations through the rotational correlation time of fluorescein in a multiwell plate and apply this technique to probe the microviscosity in live cells.
Review of Scientific Instruments | 2002
S.E.D. Webb; Y. Gu; Sandrine Lévêque-Fort; Jan Siegel; M.J. Cole; K. Dowling; Richard Jones; P. M. W. French; M. A. A. Neil; R. Juškaitis; L. O. D. Sucharov; Tony Wilson; M. J. Lever
This article describes a wide-field time-domain fluorescence lifetime imaging (FLIM) microscope with optical sectioning. The FLIM system utilizes a wide-field time-gated optical image intensifier, with a minimum gate width of 85 ps, to achieve high temporal resolution of fluorescence decays induced by ultrashort laser pulses. Different configurations, using excitation pulses of picojoule energy at 80 MHz repetition rate and of nanojoule energy at 10 kHz, are compared. The instrument has a temporal dynamic range spanning from 100 ps to tens of μs and is shown to have a temporal discrimination better than 10 ps. When applied to laser dye samples, it has produced FLIM maps demonstrating sensitivity to variations in both chemical species and local environment, e.g., viscosity. Wide-field optical sectioning is achieved using the technique of structured illumination, which is applied to remove out-of-focus light that can result in lifetime artifacts. The sectioning strength, which may be adjusted by choosing an appropriate spatial modulation frequency, is characterized and shown to be comparable to that of a confocal microscope. Practical considerations concerned with improving the quality of sectioned fluorescence lifetime maps, including using a large bit depth camera, are discussed.
Review of Scientific Instruments | 2003
Jan Siegel; Klaus Suhling; Sandrine Lévêque-Fort; S.E.D. Webb; Daniel M. Davis; David Phillips; Y. Sabharwal; P. M. W. French
Polarization-resolved fluorescence lifetime imaging (FLIM) can provide information about the rotational diffusion of a fluorophore. We have developed a wide-field time-resolved fluorescence anisotropy imaging (TR-FAIM) system to quantitatively image both the fluorescence lifetime and the rotational correlation time of a fluorophore. Upon excitation with linearly polarized light, we simultaneously image the parallel and perpendicular polarization components of the fluorescence emission employing a polarization-resolved imager in front of a time-gated intensified CCD. We demonstrate this technique by imaging the rotational correlation time of fluorescein in solutions of varying viscosity in a multiwell plate and in live cells. Introduction
Optics Letters | 2001
Jan Siegel; Daniel S. Elson; Sed Webb; D. Parsons-Karavassilis; Sandrine Lévêque-Fort; M.J. Cole; M. J. Lever; P. M. W. French; M. A. A. Neil; R. Juškaitis; L. O. D. Sucharov; Tony Wilson
We report a novel whole-field three-dimensional fluorescence lifetime imaging microscope that incoporates multispectral imaging to provide five-dimensional (5-D) fluorescence microscopy. This instrument, which can acquire a 5-D data set in less than a minute, is based on potentially compact and inexpensive diode-pumped solid-state laser technology. We demonstrate that spectral discrimination as well as optical sectioning minimize artifacts in lifetime determination and illustrate how spectral discrimination improves the lifetime contrast of biological tissue.
Optics Letters | 2002
D. S. Elson; Jan Siegel; S.E.D. Webb; Sandrine Lévêque-Fort; M. J. Lever; P. M. W. French; K. Lauritsen; M. Wahl; R. Erdmann
We report a wide-field fluorescence lifetime imaging (FLIM) system that uses a blue picosecond pulsed diode laser as the excitation source. This represents a significant miniaturization and simplification compared with other time-domain FLIM instruments that should accelerate the development of clinical and real-world applications of FLIM. We have demonstrated this instrument in two configurations: a macroimaging setup applied to multiwell plate assays of chemically and biologically interesting fluorophores and a microscope system that has been applied to imaging of tissue sections. The importance of the adjustable repetition rate of this laser source is discussed with respect to noise reduction and precision in the lifetime determination, illustrating a further significant advantage over conventional mode-locked solid-state lasers.
Applied Optics | 2001
Sandrine Lévêque-Fort
An original acousto-optic method is described that allows one to reveal optical contrasts through biological tissues that are several centimeters thick with a millimeter-sized resolution. This technique is based on the interaction of scattered laser light with a focused ultrasonic field. The modulation depth of the optical speckle is related to local optical properties of the sample. Our parallel-processing approach to the demodulation of the speckle improves the observed degree of modulation by 2 orders of magnitude and quickly yields a good statistical value. Optically absorbing objects were imaged inside 35-mm-thick biological tissues.
The EMBO Journal | 2015
Marie‐Thérèse El‐Daher; Emilie Hangen; Julie Bruyère; Ghislaine Poizat; Ismael Al-Ramahi; Raúl Pardo; Nicolas Bourg; Sylvie Souquere; Céline Mayet; Gérard Pierron; Sandrine Lévêque-Fort; Juan Botas; Sandrine Humbert; Frédéric Saudou
Cleavage of mutant huntingtin (HTT) is an essential process in Huntingtons disease (HD), an inherited neurodegenerative disorder. Cleavage generates N‐ter fragments that contain the polyQ stretch and whose nuclear toxicity is well established. However, the functional defects induced by cleavage of full‐length HTT remain elusive. Moreover, the contribution of non‐polyQ C‐terminal fragments is unknown. Using time‐ and site‐specific control of full‐length HTT proteolysis, we show that specific cleavages are required to disrupt intramolecular interactions within HTT and to cause toxicity in cells and flies. Surprisingly, in addition to the canonical pathogenic N‐ter fragments, the C‐ter fragments generated, that do not contain the polyQ stretch, induced toxicity via dilation of the endoplasmic reticulum (ER) and increased ER stress. C‐ter HTT bound to dynamin 1 and subsequently impaired its activity at ER membranes. Our findings support a role for HTT on dynamin 1 function and ER homoeostasis. Proteolysis‐induced alteration of this function may be relevant to disease.