Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sang O Park is active.

Publication


Featured researches published by Sang O Park.


Resuscitation | 2012

A different rescuer changing strategy between 30:2 cardiopulmonary resuscitation and hands-only cardiopulmonary resuscitation that considers rescuer factors: A randomised cross-over simulation study with a time-dependent analysis

Dae Young Hong; Sang O Park; Kyeong Ryong Lee; Kwang Je Baek; Dong Hyuk Shin

AIM To compare the time-dependent changes in the quality of chest compressions in 30:2 cardiopulmonary resuscitation (CPR) and hands-only cardiopulmonary resuscitation (HO-CPR) and to evaluate how individual rescuer factors affect the quality of chest compressions over time for both CPR techniques. METHODS Total 1028 adult hospital and university workers participated in CPR training programs including sessions of 30:2 CPR and HO-CPR. Tests of both CPR methods were performed in a random order using a manikin with Skill-Reporter™. Data were collected from 863 subjects. The time-dependent changes in chest compressions quality and the effects of individual rescuer factors (age, gender, body mass index (BMI), prior CPR training and experience) were analysed using the general linear model for a repeated-measures procedure. RESULTS In HO-CPR, the mean proportion of correct compressions depth (MPCD) decreased significantly throughout the time sectors following 20-40s (74.4-50.4% in 100-120 s) compared to 30:2 CPR (83.4-76.3% in 100-120 s) (p<0.0001). A significant decline of MPCD (MPCD<70%) was initially observed at 40-60s in HO-CPR, however, this pattern was not observed in 30:2 CPR. Individual rescuer factors minimally affected the time-dependent change in MPCD during 30:2 CPR. For HO-CPR, all rescuer factors except for male or obese/overweight (BMI≥25) were associated with a significant declines of MPCD, and these decline were usually observed from 40 to 60s. CONCLUSION Switching rescuers at an interval of 2-min is reasonable for 30:2 CPR. However, for HO-CPR switching rescuers every 1-min may be preferable except when rescuers are male or obese/overweight (BMI≥25).


Journal of Burn Care & Research | 2013

Plasma neutrophil gelatinase-associated lipocalin as early biomarker for acute kidney injury in burn patients.

Dae Young Hong; Jong Ho Lee; Sang O Park; Kwang Je Baek; Kyeong Ryong Lee

This study evaluated whether measurements of plasma neutrophil gelatinase-associated lipocalin (NGAL) can predict acute kidney injury (AKI) in adult burn patients, and assessed the use of this biomarker in risk stratification. We performed a prospective observational study of consecutive patients with major burns admitted to the burn center within 12 hours of injury. Samples for plasma NGAL assay were obtained three times (at admission, day 3, and day 7). The main outcome measures were occurrence of AKI based on Risk-Injury-Failure classification and mortality. A total 45 patients with burns injury were enrolled. There was a high prevalence (11 of 45, 24.4%) of AKI in burn patients. All patients with AKI developed AKI after hospital day 8. Multivariate logistic regression analysis demonstrated that burn size and abbreviated burn severity index were independent risk factors of AKI. Patients who developed AKI had significantly higher admission plasma NGAL levels, hospital day 3 NGAL levels, and hospital day 7 NGAL levels. Especially, hospital day 7 NGAL levels strongly correlated with AKI. For concentration in plasma NGAL at hospital day 7, the area under the receiver operating characteristic curve was 0.903, sensitivity was 87%, and specificity was 91% for a cutoff value of 125 ng/ml. The mean plasma NGAL at hospital day 7 of patients who died was significantly higher than that of patients who did not (485 ng/ml vs 111 ng/ml, P = .001). Plasma NGAL levels are early predictive biomarkers for AKI and its clinical outcomes after burn injury.


Resuscitation | 2016

Video laryngoscopy vs. direct laryngoscopy: Which should be chosen for endotracheal intubation during cardiopulmonary resuscitation? A prospective randomized controlled study of experienced intubators ☆

Jong Won Kim; Sang O Park; Kyeong Ryong Lee; Dae Young Hong; Kwang Je Baek; Young Hwan Lee; Jeong Hun Lee; Pil Cho Choi

AIM This study compared endotracheal intubation (ETI) performance during cardiopulmonary resuscitation (CPR) between direct laryngoscopy (DL) and video laryngoscopy (VL) (GlideScope(®)) by experienced intubators (>50 successful ETIs). METHODS This was a prospective randomized controlled study conducted in an emergency department between 2011 and 2013. Intubators who used DL or VL were randomly allocated to ETI during CPR. Data were collected from recorded video clips and rhythm sheets. The success, speed, complications, and chest compressions interruption were compared between the two devices. RESULTS Total 140 ETIs by experienced intubators using DL (n=69) and VL (n=71) were analysed. There were no significant differences between DL and VL in the ETI success rate (92.8% vs. 95.8%; p=0.490), first-attempt success rate (87.0% vs. 94.4%; p=0.204), and median time to complete ETI (51 [36-67] vs. 42 [34-62]s; p=0.143). In both groups, oesophageal intubation and dental injuries seldom occurred. However, longer chest compressions interruption occurred using DL (4.0 [1.0-11.0]s) compared with VL (0.0 [0.0-1.0]s) and frequent serious no-flow (interruption>10s) occurred with DL (18/69 [26.1%]) compared with VL (0/71) (p<0.001). For highly experienced intubators (>80 successful ETIs), frequent serious no-flow occurred in DL (14/55 [25.5%] vs. 0/57 in VL). CONCLUSIONS The ETI success, speed and complications during CPR did not differ significantly between the two devices for experienced intubators. However, the VL was superior in terms of completion of ETI without chest compression interruptions. TRIAL REGISTRATION Clinical Research Information Service (CRIS) in South Korea KCT0000849.


Journal of The Korean Surgical Society | 2015

Effects of combination therapy of docetaxel with selenium on the human breast cancer cell lines MDA-MB-231 and MCF-7

Sang O Park; Young Bum Yoo; Yong Hun Kim; Kwang Je Baek; Jung Hyun Yang; Pil Cho Choi; Jeong Hun Lee; Kyeong Ryong Lee; Kyoung Sik Park

Purpose The anticancer property and cytoprotective role of selenium in chemotherapy have been reported. However, the combination effects of selenium on chemotherapy for advanced breast cancer have not yet been clearly defined. The purpose of this study was to investigate the combined effects of selenium on chemotherapy using docetaxel on breast cancer cell lines. Methods Under adherent culture conditions, two breast cancer cell lines, MDA-MB-231 and MCF-7, were treated with docetaxel at 500pM and selenium at 100nM, 1µM, or 10µM. Changes in cell growth, cell cycle duration, and degree of apoptosis after 72 hours in each treated group were evaluated. Results In the MDA-MB-231 cells, the combination therapy group (docetaxel at 500pM plus selenium at 10µM) showed a significantly decreased percentage of cell growth (15% vs. 28%; P = 0.004), a significantly increased percentage of late apoptosis (63% vs. 26%; P = 0.001), and an increased cell cycle arrest in the G2/M phase (P = 0.001) compared with the solitary docetaxel therapy group. Isobologram analysis demonstrated the synergistic effect of the combination therapy in the MDA-MB-231 cells. However, in the MCF-7 cells, no significant differences in the percentage of cell growth apoptosis, the percentage of apoptosis, and the pattern of cell cycle arrest were noted between the combination therapy groups and the solitary docetaxel therapy group. Conclusion Our in vitro study indicated that the combination of selenium with docetaxel inhibits cell proliferation through apoptosis and cell arrest in the G2/M phase in MDA-MB-231 breast cancer cells.


The Journal of Advanced Prosthodontics | 2014

Comparable efficacy of silk fibroin with the collagen membranes for guided bone regeneration in rat calvarial defects

Jwa-Young Kim; B.E. Yang; Jin-Hee Ahn; Sang O Park; Hye-Won Shim

PURPOSE Silk fibroin (SF) is a new degradable barrier membrane for guided bone regeneration (GBR) that can reduce the risk of pathogen transmission and the high costs associated with the use of collagen membranes. This study compared the efficacy of SF membranes on GBR with collagen membranes (Bio-Gide®) using a rat calvarial defect model. MATERIALS AND METHODS Thirty-six male Sprague Dawley rats with two 5 mm-sized circular defects in the calvarial bone were prepared (n=72). The study groups were divided into a control group (no membrane) and two experimental groups (SF membrane and Bio-Gide®). Each group of 24 samples was subdivided at 2, 4, and 8 weeks after implantation. New bone formation was evaluated using microcomputerized tomography and histological examination. RESULTS Bone regeneration was observed in the SF and Bio-Gide®-treated groups to a greater extent than in the control group (mean volume of new bone was 5.49 ± 1.48 mm3 at 8 weeks). There were different patterns of bone regeneration between the SF membrane and the Bio-Gide® samples. However, the absolute volume of new bone in the SF membrane-treated group was not significantly different from that in the collagen membrane-treated group at 8 weeks (8.75 ± 0.80 vs. 8.47 ± 0.75 mm3, respectively, P=.592). CONCLUSION SF membranes successfully enhanced comparable volumes of bone regeneration in calvarial bone defects compared with collagen membranes. Considering the lower cost and lesser risk of infectious transmission from animal tissue, SF membranes are a viable alternative to collagen membranes for GBR.


Resuscitation | 2016

The prognostic value of the grey-to-white matter ratio in cardiac arrest patients treated with extracorporeal membrane oxygenation

Young Hwan Lee; Young Taeck Oh; Hee Cheol Ahn; Hyoung Soo Kim; Sang Jin Han; Jae Jun Lee; Tae Hun Lee; Jeong Yeol Seo; Dong Hyuk Shin; Sang Ook Ha; Sang O Park

AIM The grey-to-white matter ratio (GWR) is a reliable predictor of the neurological outcome of out-of-hospital cardiac arrest (OHCA). However, the reliability in patients receiving extracorporeal membrane oxygenation-assisted cardiopulmonary resuscitation (ECPR) remains unknown. We evaluated the utility of the GWR in predicting neurological outcomes in ECPR-treated patients. METHODS This single-centre retrospective study was conducted from July 2009 to January 2014. Patients who received ECPR for OHCA were classified into two groups: Cerebral performance category(CPC) 1-2 was defined as good, CPC 3-5 as poor outcome. Four GWR (GWR-AV[average], GWR-CO[cortex], GWR-BG[basal ganglia], and GWR-SI [simplified])were evaluated and compared between the groups. RESULTS Of 38 patients who received ECPR for OHCA, 30 patients were enrolled. Five (16.7%) had a good outcome and 25(83.3%) a poor outcome. All GWR were significantly higher in the good outcome group than in the poor outcome group. ROC curve analysis produced the following areas under the curve: GWR-AV=0.920 (95% CI 0.761 to 0.987), GWR-BG=0.872 (95%CI 0.699 to 0.965), GWR-CO=0.952 (95% CI 0.806 to 0.997), and GWR-SI=0.848(95% CI 0.670 to 0.962). The cut-off value with 100% specificity for the prediction of the poor outcome was 1.23 for GWR-AV (sensitivity: 76%), 1.24 for GWR-BG (sensitivity: 88.0%), 1.22 for GWR-CO (sensitivity: 64%), and 1.21 for GWR-SI (sensitivity: 76%). CONCLUSIONS In ECPR, GWR of patients with poor outcome was significantly lower than that of patients with good outcome.


Resuscitation | 2016

Plasma neutrophil gelatinase-associated lipocalin as an early predicting biomarker of acute kidney injury and clinical outcomes after recovery of spontaneous circulation in out-of-hospital cardiac arrest patients☆

Sang O Park; Ji Yun Ahn; Young Hwan Lee; Yu Jung Kim; Yong Hun Min; Hee Cheol Ahn; You Dong Sohn; Seung-Min Park; Young Taeck Oh; Dong Hyuk Shin

AIMS To determine whether the level of plasma neutrophil gelatinase-associated lipocalin (NGAL) can predict acute kidney injury (AKI) and clinical outcomes after recovery of spontaneous circulation (ROSC) in patients with out-of-hospital cardiac arrest (OHCA). METHODS We conducted a prospective observational study of consecutive admitted patients with ROSC after OHCA between January 2013 and March 2015. Plasma was collected within 4h of ROSC to determine the level of NGAL. Outcome variables were AKI, 30-day survival, and good neurological outcome (GNO). We evaluated the association between NGAL and outcomes. RESULTS Fifty-four patients were included. AKI occurred in 26 (48.0%); 15 (27.7%) survived over 30 days and 8 had GNO (14.8%). NGAL was significantly lower in the group with non-AKI, 30-day survival, and GNO. To predict AKI, 30-day survival, and GNO, the area under the receiver operating characteristic curve for NGAL was 0.810, 0.728, and 0.875, respectively. In a logistic regression model, NGAL >189 ngml(-1) was strongly associated with AKI (odds ratio [OR] 7.01, 95% confidence interval [CI]: 1.89-26.01) in a multivariate model. A lower level of NGAL was strongly associated with 30-day survival (OR 6.12, 95% CI: 1.64-23.42 at NGAL <153.5 ngml(-1)) and GNO (OR 19.83, 95% CI: 2.21-178.32 at NGAL <129.5 ngml(-1)) in a univariate model, but was not significantly associated with outcomes in a multivariate model. CONCLUSIONS Plasma NGAL is a strong predictor of AKI in patients exhibiting OHCA at ICU admission. Lower levels of NGAL are associated with greater chance of 30-day survival and GNO.


European Journal of Emergency Medicine | 2013

Tracheal intubation during chest compressions performed by qualified emergency physicians unfamiliar with the Pentax-airwayscope

Donghyuk Shin; Sang Kuk Han; Pil Cho Choi; Min Seob Sim; Jeong Hun Lee; Sang O Park

Objective Experienced emergency physicians were recruited and a randomized crossover trial was conducted to compare the performance of the Pentax-Airwayscope (AWS) video-laryngoscope with the Macintosh laryngoscope (McL) for tracheal intubation during continuous chest compressions under three different scenarios: (1) normal airway, (2) limited neck mobility, and (3) tongue edema. Methods Thirty-six experienced emergency physicians performed intubations on a manikin in each of three scenarios. The sequences of scenarios and intubating devices were randomized. Time to complete intubation (primary end point), time to visualization of the vocal cords, the overall success rate, percentage of glottic opening, dental compression, and ease of intubation were determined. Results The times (median [interquartile range]) to complete tracheal intubation were significantly shorter with the AWS than the McL in all three scenarios (11.6 [8.0-14.7] vs. 15.1 [12.8-17.9] s, 13.5 [10.5-20.9] vs. 17.0 [14.1-19.9] s, and 13.6 [11.1-20.9] vs. 15.1 [18.6-37.5] s, respectively). The overall success rates were higher with the AWS than the McL in the difficult intubation scenario (77.8 vs. 100%). The AWS was also more effective than the McL with respect to the percentage of glottic opening, dental compression, and ease of intubation in all three scenarios. Conclusion Although participants were experienced emergency physicians familiar with the McL and unfamiliar with the AWS, the AWS proved to be a better tool than the McL to perform tracheal intubation during continuous chest compressions on a manikin. The AWS should be considered as an initial intubating tool to perform tracheal intubation during continuous chest compressions rather than the McL.


Emergency Medicine Journal | 2013

Efficacy of the Disposcope endoscope, a new video laryngoscope, for endotracheal intubation in patients with cervical spine immobilisation by semirigid neck collar: comparison with the Macintosh laryngoscope using a simulation study on a manikin

Sang O Park; Dong Hyuk Shin; Kyeong Ryong Lee; Dae Young Hong; Eun Jung Kim; Kwang Je Baek

Objective To evaluate whether endotracheal intubation in patients with cervical spine immobilisation by a semirigid neck collar is easier using the Disposcope endoscope (DE), a new video laryngoscope, than with the Macintosh laryngoscope (ML). Methods Sixty-eight medical interns who participated in a training programme for endotracheal intubation using the DE and ML were recruited to the randomised crossover trial 1 week after completing the training programme. In the trial, they used both the DE and the ML to perform intubation on a manikin wearing a semirigid neck collar. The time required to view the vocal cords and to complete intubation, successful endotracheal intubation, modified Cormack–Lehane classification (CL grade) and dental injury were recorded and analysed. Results The mean (SD) time to view the vocal cords was significantly shorter with the DE than with the ML (10.0 (7.0) vs 20.8 (18.9) s; p<0.0001). There were higher rates of CL grades 1 and 2a (69.1% and 22.1%) using the DE than with the ML (10.3% and 14.7%). All 68 participants had a higher rate of successful endotracheal intubation using the DE than using the ML (68 (100%) vs 47 (69.1%); p<0.0001). It took less time to complete endotracheal intubation with the DE than with the ML (p<0.0001). Conclusions In patients with cervical spine immobilisation by a semirigid neck collar, the DE may be a more effective device for endotracheal intubation than the ML.


BMJ Open | 2016

Efficacy of various types of laryngoscope (direct, Pentax Airway Scope and GlideScope) for endotracheal intubation in various cervical immobilisation scenarios: a randomised cross-over simulation study

Jong Won Kim; Kyeong Ryong Lee; Dae Young Hong; Kwang Je Baek; Young Hwan Lee; Sang O Park

Objective To compare the efficacy of direct laryngoscopy (DL), Pentax Airway Scope (PAWS) and GlideScope video laryngoscope (GVL) systems for endotracheal intubation (ETI) in various cervical immobilisation scenarios: manual in-line stabilisation (MILS), Philadelphia neck collar (PNC) (moderate limit of mouth opening) and Stifneck collar (SNC) (severe limit of mouth opening). Design Randomised cross-over simulation study. Setting and Participants 35 physicians who had >30 successful ETI experiences at a tertiary hospital in Seoul, Korea. Primary and secondary outcome measures Participants performed ETI using PAWS, GVL and DL randomly in simulated MILS, PNC and SNC scenarios in our simulation centre. The end points were successful ETI and the time to complete ETI. In addition, modified Cormack-Lehane (CL) classification and pressure to teeth were recorded. Results In MILS, there were no significant differences in the rate of success of ETI between the three devices: 33/35(94.3%) for DL vs 32/35(91.4%) for GVL vs 35/35(100.0%) for PAWS; p=0.230). PAWS achieved successful ETI more quickly (19.8 s) than DL (29.6 s) and GVL (35.4 s). For the PNC scenario, a higher rate of successful ETI was achieved with GVL 33/35 (94.3%) than PAWS 29/35 (82.9%) or DL 25/35 (71.4%) (p=0.040). For the SNC scenario, a higher rate of successful ETI was achieved with GVL 28/35(80.0%) than with DL 14/35(40.0%) and PAWS 7/35(20.0%) (p<0.001). For the PNC and SNC scenarios, GVL provided a relatively good view of the glottis, but a frequent pressure to teeth occurred. Conclusions All three devices are suitable for ETI in MILS. DL is not suitable in both neck collar scenarios. PAWS showed faster intubations in MILS, but was not suitable in the SNC scenario. GVL is most suitable in all cervical immobilisation scenarios, but may cause pressure to teeth more frequently.

Collaboration


Dive into the Sang O Park's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

JongWon Kim

Gwangju Institute of Science and Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge