Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sarah A. Rodriguez is active.

Publication


Featured researches published by Sarah A. Rodriguez.


Gastrointestinal Endoscopy | 2008

Endoscopic mucosal resection and endoscopic submucosal dissection

Sergey V. Kantsevoy; Douglas G. Adler; Jason D. Conway; David L. Diehl; Francis A. Farraye; Richard S. Kwon; Petar Mamula; Sarah A. Rodriguez; Raj J. Shah; Louis M. Wong Kee Song; William M. Tierney

The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methods are used, with a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the ‘‘related articles’’ feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases data from randomized controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. For this review the MEDLINE database was searched through September 2007 by using the key words ‘‘endoscopic lesion removal,’’ ‘‘endoscopic mucosal resection,’’ ‘‘EMR,’’ ‘‘endoscopic submucosal dissection,’’ and ‘‘ESD.’’ Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Gastrointestinal Endoscopy | 2013

Wireless capsule endoscopy

Amy Wang; Subhas Banerjee; Bradley A. Barth; Yasser M. Bhat; Shailendra S. Chauhan; Klaus T. Gottlieb; Vani J. Konda; John T. Maple; Faris Murad; Patrick R. Pfau; Douglas K. Pleskow; Uzma D. Siddiqui; Jeffrey L. Tokar; Sarah A. Rodriguez

Over the last decade, WCE has established itself as a valuable test for imaging the small intestine. It is a safe and relatively easy procedure to perform that can provide valuable information in the diagnosis of small-bowel conditions. Its applications still remain limited within the esophagus and colon. Future developments may include improving visualization within the esophagus and developing technologies that may allow manipulation of the capsule within the GI tract and biopsy capabilities.


Gastrointestinal Endoscopy | 2009

Endoscopic hemostatic devices

Jason D. Conway; Douglas G. Adler; David L. Diehl; Francis A. Farraye; Sergey V. Kantsevoy; Vivek Kaul; Sripathi R. Kethu; Richard S. Kwon; Petar Mamula; Sarah A. Rodriguez; William M. Tierney

The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (US Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the ‘‘related articles’’ feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but, in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through September 2008 for articles related to endoscopic hemostatic devices by using the keywords ‘‘multipolar electrocautery,’’ ‘‘bipolar electrocautery,’’ ‘‘heater probe,’’ ‘‘hemostatic grasper,’’ ‘‘argon plasma coagulator,’’ ‘‘injection needle,’’ ‘‘endoloop,’’ ‘‘clip,’’ paired with ‘‘complication,’’ ‘‘perforation,’’ ‘‘peptic ulcer disease,’’ ‘‘gastric antral vascular ectasia,’’ ‘‘Dieulafoy lesion,’’ ‘‘Mallory-Weiss tear,’’ ‘‘radiation induced angioectasias,’’ ‘‘diverticular bleeding,’’ ‘‘angiodysplasia,’’ and ‘‘postpolypectomy bleeding.’’ Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requir-


Gastrointestinal Endoscopy | 2013

Tissue adhesives: cyanoacrylate glue and fibrin sealant

Yasser M. Bhat; Subhas Banerjee; Bradley A. Barth; Shailendra S. Chauhan; Klaus T. Gottlieb; Vani J. Konda; John T. Maple; Faris Murad; Patrick R. Pfau; Douglas K. Pleskow; Uzma D. Siddiqui; Jeffrey L. Tokar; Amy Wang; Sarah A. Rodriguez

The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported adverse events of a given technology. Both are supplemented by accessing the “related articles” feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the Committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through August 2012 for relevant articles by using the key words cyanoacrylate, cyanoacrylate glue, cyanoacrylate and gastroenterology, cyanoacrylate and endoscopy, fibrin glue, fibrin sealant, tissue glue and endoscopy. Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Gastrointestinal Endoscopy | 2009

Confocal laser endomicroscopy

Sergey V. Kantsevoy; Douglas G. Adler; Jason D. Conway; David L. Diehl; Francis A. Farraye; Vivek Kaul; Sripathi R. Kethu; Richard S. Kwon; Petar Mamula; Sarah A. Rodriguez; William M. Tierney

©2014 Blue Cross and Blue Shield of Louisiana An independent licensee of the Blue Cross and Blue Shield Association No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise, without permission from Blue Cross and Blue Shield of Louisiana. Page 1 of 11 Applies to all products administered or underwritten by Blue Cross and Blue Shield of Louisiana and its subsidiary, HMO Louisiana, Inc.(collectively referred to as the “Company”), unless otherwise provided in the applicable contract. Medical technology is constantly evolving, and we reserve the right to review and update Medical Policy periodically.


Gastrointestinal Endoscopy | 2009

Overtube use in gastrointestinal endoscopy.

William M. Tierney; Douglas G. Adler; Jason D. Conway; David L. Diehl; Francis A. Farraye; Sergey V. Kantsevoy; Vivek Kaul; Sripathi R. Kethu; Richard S. Kwon; Petar Mamula; Marcos Pedrosa; Sarah A. Rodriguez

The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent clinical studies on the topic, and a MAUDE (Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the ‘‘related articles’’ feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but, in many cases, data from randomized controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the governing board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through March 2009 for articles related to overtube use in GI endoscopy by using the keywords overtube, intubation, enteral access, enteroscopy, and foreign bodies, paired with endoscopy, gastrointestinal. Practitioners should continue to monitor the medical literature for subsequent data about the efficacy, safety, and socioeconomic aspects of these technologies. Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Gastrointestinal Endoscopy | 2012

Equipment for pediatric endoscopy.

Bradley A. Barth; Subhas Banerjee; Yasser M. Bhat; David J. Desilets; Klaus T. Gottlieb; John T. Maple; Patrick R. Pfau; Douglas K. Pleskow; Uzma D. Siddiqui; Jeffrey L. Tokar; Amy Wang; Louis M. Wong Kee Song; Sarah A. Rodriguez

d f o 2 u t b f p t The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidencebased methodology is used by performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the “related articles” feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the governing board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through June 2011 for articles related to endoscopy in pediatric patients by using the key words pediatric, children, infants, endoscopy, colonoscopy, gastrointestinal bleeding, single balloon enteroscopy, double balloon enteroscopy, capsule endoscopy, biopsy, esophageal strictures, dilation, endoscopic ultrasound, and ERCP. Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Molecular Cancer Research | 2014

Targeting Inhibitors of the Tumor Suppressor PP2A for the Treatment of Pancreatic Cancer

Amy S. Farrell; Brittany Allen-Petersen; Colin J. Daniel; Xiaoyan Wang; Zhiping Wang; Sarah A. Rodriguez; Soren Impey; Jessica Oddo; Michael P. Vitek; Charles D. Lopez; Dale J. Christensen; Brett C. Sheppard; Rosalie C. Sears

Pancreatic cancer is a deadly disease that is usually diagnosed in the advanced stages when few effective therapies are available. Given the aggressive clinical course of this disease and lack of good treatment options, the development of new therapeutic agents for the treatment of pancreatic cancer is of the upmost importance. Several pathways that have shown to contribute to pancreatic cancer progression are negatively regulated by the tumor suppressor protein phosphatase 2A (PP2A). Here, the endogenous inhibitors of PP2A, SET (also known as I2PP2A) and cancerous inhibitor of PP2A (CIP2A), were shown to be overexpressed in human pancreatic cancer, contributing to decreased PP2A activity and overexpression and stabilization of the oncoprotein c-Myc, a key PP2A target. Knockdown of SET or CIP2A increases PP2A activity, increases c-Myc degradation, and decreases the tumorigenic potential of pancreatic cancer cell lines both in vitro and in vivo. Moreover, treatment with a novel SET inhibitor, OP449, pharmacologically recapitulates the phenotypes and significantly reduces proliferation and tumorigenic potential of several pancreatic cancer cell lines, with an accompanying attenuation of cell growth and survival signaling. Furthermore, primary cells from patients with pancreatic cancer were sensitive to OP449 treatment, indicating that PP2A-regulated pathways are highly relevant to this deadly disease. Implications: The PP2A inhibitors SET and CIP2A are overexpressed in human pancreatic cancer and are important for pancreatic cancer cell growth and transformation; thus, antagonizing SET and/or CIP2A may be an innovative approach for the treatment of human pancreatic cancer. Mol Cancer Res; 12(6); 924–39. ©2014 AACR.


Current Opinion in Gastroenterology | 2007

Endoscopic diagnosis of gastrointestinal stromal cell tumors.

Sarah A. Rodriguez; Douglas O. Faigel

Purpose of review To outline the recommended course of action when a subepithelial lesion is encountered during upper endoscopy. It will focus on the endoscopic and endosonographic features common to gastrointestinal stromal tumors, and the optimal tests performed to confirm the diagnosis of a gastrointestinal stromal tumor. Recent findings The major recent finding of a mutation in the protooncogene c-kit which is unique to gastrointestinal stromal tumors has led to their reclassification as separate from other spindle cell tumors. Endoscopic ultrasound is a key component of the evaluation of submucosal lesions of the gastrointestinal tract, allowing determination of the wall layer of origin of the lesion and diagnostic sampling. Endosonographic features of gastrointestinal stromal tumors associated with high-risk lesions include size larger than 4–5 cm, irregular or invasive border, cystic spaces and malignant appearing lymph nodes. Endoscopic ultrasound-guided fine needle aspiration is generally adequate for tissue acquisition. Immunohistochemical analysis is performed on the tissue to differentiate gastrointestinal stromal tumors from other spindle cell neoplasms. Summary The clinical behavior of gastrointestinal stromal tumors is variable. Accurate preoperative endoscopic characterization of the lesion with fine needle aspiration is critical for treatment decisions and for an assessment of prognosis.


Gastrointestinal Endoscopy | 2013

Methods of luminal distention for colonoscopy

John T. Maple; Subhas Banerjee; Bradley A. Barth; Yasser M. Bhat; David J. Desilets; Klaus T. Gottlieb; Patrick R. Pfau; Douglas K. Pleskow; Uzma D. Siddiqui; Jeffrey L. Tokar; Amy Wang; Louis M. Wong Kee Song; Sarah A. Rodriguez

w e r i n t a d The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidencebased methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported adverse events of a given technology. Both are supplemented by accessing the “related articles” feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the Committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through February 2012 for relevant articles by using the key words “colonoscopy,” “insufflation,” “air,” “carbon dioxide,” and “water.” Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.

Collaboration


Dive into the Sarah A. Rodriguez's collaboration.

Top Co-Authors

Avatar

Amy Wang

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bradley A. Barth

University of Texas Southwestern Medical Center

View shared research outputs
Top Co-Authors

Avatar

Patrick R. Pfau

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Douglas K. Pleskow

Beth Israel Deaconess Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

John T. Maple

University of Oklahoma Health Sciences Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge