Sarfaraz Ahmed Mahesar
University of Sindh
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Sarfaraz Ahmed Mahesar.
Talanta | 2009
Syed Tufail Hussain Sherazi; M. Y. Talpur; Sarfaraz Ahmed Mahesar; Aftab A. Kandhro; Sarfraz Arain
The prospect of using single bounce attenuated total reflectance (SB-ATR)-Fourier transform infrared (FTIR) spectroscopy as a rapid quantitative tool to determine the main fatty acid groups present in different edible oils was investigated. Partial least squares (PLS) calibrations were developed using SB-ATR-FTIR spectra which were associated with fatty acid groups (saturated, trans, mono- and polyunsaturated) using quantitative data obtained by gas chromatography (GC). Good calibrations were obtained for all main four fat groups (saturated, mono, trans and polyunsaturated) with excellent precision. The coefficient of determination (R(2)), root mean square error of prediction (RMSEP) and bias for validation set were obtained as 0.999, 2.43 and 0.998 for saturated; 0.999, 1.850 and 0.003 for mono; 0.999, 0.625 and -0.001 for trans while for poly the values were 0.999, 1.170 and 0.003, respectively. The results of 13 validation samples for total saturated, mono, trans and polyunsaturated fats by FI-IR were found in the range of 8.16-55.16, 37.62-74.75, 0.20-18.16 and 1.36-62.35%, respectively. The present study shows that it may well be possible to expand the utility of SB-ATR-FTIR spectroscopy not only to provide isolated trans data, but also serve as a simple, rapid and quantitative means of categorizing the main groups present in the edible oils. The information obtained would be useful for meeting the new lipid nutritional labeling requirements.
Food Chemistry | 2008
Aftab A. Kandhro; Syed Tufail Hussain Sherazi; Sarfaraz Ahmed Mahesar; Muhammad Iqbal Bhanger; M. Younis Talpur; Abdul Rauf
Ten margarine brands of Pakistan were analyzed for their fatty acid composition with emphasis on trans fatty acids (TFA) using GC-MS. Saturated, cis-monounsaturated and polyunsaturated fatty acids were present at 24.2-58.1, 5.7-35.4 and 3.8-37.4% of total fatty acids, respectively. Among the saturated fatty acids, palmitic acid (16.9-33.8%) was dominant in all analyzed margarine brands and its higher amount indicates that palm oil was a major contributor in the margarine manufacturing. Among samples tested only one contained a low level of TFA (2.2%) while the rest contained very high amounts of TFA (11.5-34.8%) which clearly shows that hydrogenated oils were used in the formulation of margarines. Fatty acid profiles demonstrated that all samples belong to the hard margarine category containing high amounts of trans and saturated fatty acids which is an alarming issue for the health of consumers.
Talanta | 2008
Sarfaraz Ahmed Mahesar; Syed Tufail Hussain Sherazi; Kamran Abro; Aftab A. Kandhro; Muhammad Iqbal Bhanger; F.R. van de Voort; Jacqueline Sedman
A rapid method has been developed to extract and quantitatively measure the total oil content in poultry feeds using a domestic microwave oven. The optimized extraction procedure involves the replicate (6x) extraction of 5 g of ground feed with 12 ml of hexane for 20 s in a 900 W oven. Each replicate involves the collection of the resulting miscella and its replacement with fresh solvent for re-extraction. The collected extracts were centrifuged and transferred to a vial. The solvent was evaporated to a constant weight and the residual lipid weighed. In comparison to conventional Soxhlet extraction method, lipid contents obtained using the optimized microwave procedure was not significantly different. However, FTIR analysis indicated that the microwave procedure was superior in minimizing the formation of free fatty acids (FFA) relative to the Soxhlet procedure if the temperature of the sample was kept within the range of 45-50 degrees C. This simple, sequential extraction procedure is rapid, highly efficient and provides a simple mean of quantitating the lipid content of poultry feed in less than 40 min without the need for specialized microwave oven.
Food and Chemical Toxicology | 2010
Sarfaraz Ahmed Mahesar; Syed Tufail Hussain Sherazi; Abdul Niaz; Muhammad Iqbal Bhanger; Siraj uddin; Abdul Rauf
In the present work four metals (Zn, Cd, Pb and Cu) were determined simultaneously in 28 commercial broiler poultry feeds by differential pulse anodic stripping voltammetry (DPASV) using hanging mercury drop electrode (HMDE). The digestion of poultry feeds was carried out with concentrated nitric acid and hydrogen peroxide (2:1) with the help of microwave heating. Acetate buffer of pH 5 was used as a supporting electrolyte. The limit of detection for Zn, Cd, Pb and Cu was 0.69, 0.35, 0.68 and 0.24 microg/kg, respectively. The amount of Zn, Cd, Pb and Cu in the analyzed poultry feeds was ranged between 54.3-482.2, 3.8-33.6, 23.2-32.6 and 12.3-65.8 mg/kg, respectively. In most of analyzed poultry feed samples, the amount of Cd and Pb was found to be greater than the maximum tolerable level (MTL) which could be harmful for the poultry.
Talanta | 2010
M. Younis Talpur; Syed Tufail Hussain Sherazi; Sarfaraz Ahmed Mahesar; Aijaz A. Bhutto
The aim of present study was to develop a simple method on UV spectrometer for the determination of peroxide value (PV) of the frying oil. The basis of the PV determination was the stoichiometric reaction of triphenylphosphine (TPP) with the hydroperoxides present in frying oil to produce triphenylphosphine oxide (TPPO), which exhibits a readily measurable absorption band at 240 nm by ultraviolet region. The PV ranged between 0.15 and 11.66 meq. of active oxygen per kilogram of oil as the canola oil was heated from 0 to 12h in the fryer at 180 degrees C. The proposed method was correlated with official AOCS titration method and best correlation coefficient (R(2)=0.99525) was achieved, proving that there is no significant difference in the results. Therefore, developed method could serve as an alternative to the titration method, for the determination of PV in frying oils.
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2015
Muhammad Ali Mallah; Syed Tufail Hussain Sherazi; Muhammad Iqbal Bhanger; Sarfaraz Ahmed Mahesar; Muhammad Ashraf Bajeer
A transmission FTIR spectroscopic method was developed for direct, inexpensive and fast quantification of paracetamol content in solid pharmaceutical formulations. In this method paracetamol content is directly analyzed without solvent extraction. KBr pellets were formulated for the acquisition of FTIR spectra in transmission mode. Two chemometric models: simple Beers law and partial least squares employed over the spectral region of 1800-1000 cm(-1) for quantification of paracetamol content had a regression coefficient of (R(2)) of 0.999. The limits of detection and quantification using FTIR spectroscopy were 0.005 mg g(-(1) and 0.018 mg g(-1), respectively. Study for interference was also done to check effect of the excipients. There was no significant interference from the sample matrix. The results obviously showed the sensitivity of transmission FTIR spectroscopic method for pharmaceutical analysis. This method is green in the sense that it does not require large volumes of hazardous solvents or long run times and avoids prior sample preparation.
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2013
Abdul Rauf Khaskheli; Sirajuddin; Syed Tufail Hussain Sherazi; Sarfaraz Ahmed Mahesar; Aftab A. Kandhro; Nazar Hussain Kalwar; Muhammad Ali Mallah
A rapid, reliable and cost effective analytical procedure for the estimation of ibuprofen in pharmaceutical formulations and human urine samples was developed using transmission Fourier Transform Infrared (FT-IR) spectroscopy. For the determination of ibuprofen, a KBr window with 500 μm spacer was used to acquire the FT-IR spectra of standards, pharmaceuticals as well as urine samples. Partial least square (PLS) calibration model was developed based on region from 1807 to 1,461 cm(-1) using ibuprofen standards ranging from 10 to 100 μg ml(-1). The developed model was evaluated by cross-validation to determine standard error of the models such as root mean square error of calibration (RMSEC), root mean square error of cross validation (RMSECV) and root mean square error of prediction (RMSEP). The coefficient of determination (R(2)) achieved was 0.998 with minimum errors in RMSEC, RMSECV and RMSEP with the value of 1.89%, 1.63% and 4.07%, respectively. The method was successfully applied to urine and pharmaceutical samples and obtained good recovery (98-102%).
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2013
Aftab A. Kandhro; Abdul Hafeez Laghari; Sarfaraz Ahmed Mahesar; Rubina Saleem; Aisha Nelofar; Salman Tariq Khan; Syed Tufail Hussain Sherazi
A quick and reliable analytical method for the quantitative assessment of cefixime in orally administered pharmaceutical formulations is developed by using diamond cell attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy as an easy procedure for quality control laboratories. The standards for calibration were prepared in aqueous medium ranging from 350 to 6000mg/kg. The calibration model was developed based on partial least square (PLS) using finger print region of FT-IR spectrum in the range from 1485 to 887cm(-1). Excellent coefficient of determination (R(2)) was achieved as high as 0.99976 with root mean square error of 44.8 for calibration. The application of diamond cell (smart accessory) ATR FT-IR proves a reliable determination of cefixime in pharmaceutical formulations to assess the quality of the final product.
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy | 2015
M. Younis Talpur; S. Sara Hassan; Syed Tufail Hussain Sherazi; Sarfaraz Ahmed Mahesar; Huseyin Kara; Aftab A. Kandhro; Sirajuddin
Transmission Fourier transform infrared (FTIR) spectroscopic method using 100 μm KCl cell was applied for the determination of total polar compounds (TPC), carbonyl value (CV), conjugated diene (CD) and conjugated triene (CT) in canola oil (CLO) during potato chips frying at 180 °C. The calibration models were developed for TPC, CV, CD and CT using partial least square (PLS) chemometric technique. Excellent regression coefficients (R(2)) and root mean square error of prediction values for TPC, CV, CD and CT were found to be 0.999, 0.992, 0.998 and 0.999 and 0.809, 0.690, 1.26 and 0.735, respectively. The developed calibration models were applied on samples of canola oil drawn during potato chips frying process. A linear relationship was obtained between CD and TPC with a good correlation of coefficient (R(2)=0.9816). Results of the study clearly indicated that transmission FTIR-PLS method could be used for quick and precise evaluation of oxidative changes during the frying process without using any organic solvent.
Spectroscopy | 2014
Sarfaraz Ahmed Mahesar; Aftab A. Kandhro; Abdul Rauf Khaskheli; M. Y. Talpur; Syed Tufail Hussain Sherazi
Free fatty acids (FFA) in Nigella sativa (N. sativa) commercial and seed oil were determined using single-bounce attenuated total reflectance (SB-ATR) Fourier transform infrared (FTIR) spectroscopy. Gravimetrical mixing was done by adding 0.1–40% oleic acids in neutralized N. sativa oil containing 0.1% FFA. FTIR spectroscopy technique and partial least square (PLS) calibration were used to detect the absorption region of carbonyl (C=O) which is in the range of 1690–1727 cm−1. The results of PLS calibration model and root mean square error of calibration (RMSEC) are 0.999 and 0.449, respectively. Comparing the FFA obtained in N. sativa oil by using FTIR with the FFA obtained using AOCS titrimetric method shows a positive correlation and confirms that the described method is a useful procedure.