Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Satish C. Muluk is active.

Publication


Featured researches published by Satish C. Muluk.


Biomedical Engineering Online | 2005

Fluid-structure interaction in abdominal aortic aneurysms: effects of asymmetry and wall thickness

Christine M. Scotti; Alexander D. Shkolnik; Satish C. Muluk; Ender A. Finol

BackgroundAbdominal aortic aneurysm (AAA) is a prevalent disease which is of significant concern because of the morbidity associated with the continuing expansion of the abdominal aorta and its ultimate rupture. The transient interaction between blood flow and the wall contributes to wall stress which, if it exceeds the failure strength of the dilated arterial wall, will lead to aneurysm rupture. Utilizing a computational approach, the biomechanical environment of virtual AAAs can be evaluated to study the affects of asymmetry and wall thickness on this stress, two parameters that contribute to increased risk of aneurysm rupture.MethodsTen virtual aneurysm models were created with five different asymmetry parameters ranging from β = 0.2 to 1.0 and either a uniform or variable wall thickness to study the flow and wall dynamics by means of fully coupled fluid-structure interaction (FSI) analyses. The AAA wall was designed to have a (i) uniform 1.5 mm thickness or (ii) variable thickness ranging from 0.5 – 1.5 mm extruded normally from the boundary surface of the lumen. These models were meshed with linear hexahedral elements, imported into a commercial finite element code and analyzed under transient flow conditions. The method proposed was then compared with traditional computational solid stress techniques on the basis of peak wall stress predictions and cost of computational effort.ResultsThe results provide quantitative predictions of flow patterns and wall mechanics as well as the effects of aneurysm asymmetry and wall thickness heterogeneity on the estimation of peak wall stress. These parameters affect the magnitude and distribution of Von Mises stresses; varying wall thickness increases the maximum Von Mises stress by 4 times its uniform thickness counterpart. A pre-peak systole retrograde flow was observed in the AAA sac for all models, which is due to the elastic energy stored in the compliant arterial wall and the expansion force of the artery during systole.ConclusionBoth wall thickness and geometry asymmetry affect the stress exhibited by a virtual AAA. Our results suggest that an asymmetric AAA with regional variations in wall thickness would be exposed to higher mechanical stresses and an increased risk of rupture than a more fusiform AAA with uniform wall thickness. Therefore, it is important to accurately reproduce vessel geometry and wall thickness in computational predictions of AAA biomechanics.


Journal of Vascular Surgery | 2003

Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair

Kathleen G. Raman; Nita Missig-Carroll; Tracey Richardson; Satish C. Muluk; Michel S. Makaroun

OBJECTIVE The purpose of this study is to compare both computed tomographic scan (CT) and color flow duplex ultrasound scanning (CDU) as surveillance modalities for clinically significant endoleaks and to evaluate concordance in abdominal aortic aneurysm (AAA) diameter measurements in patients after endovascular aneurysm repair (EVAR) in a busy hospital vascular laboratory. METHODS We conducted a retrospective review of all patients who underwent endovascular repair of abdominal aortic aneurysms between February 1996 and November 2002 and had same-day CT and CDU studies. Ninety-seven patients enrolled in phase II clinical studies of Ancure devices had long-term follow-up with both modalities. The other patients underwent simultaneous studies, usually only at the 1-month postoperative visit. Peripheral vascular studies were performed by two certified vascular technicians; all CT scans were reviewed by one vascular surgeon. CT was used as the standard against which the sensitivity, specificity, negative predictive value, and positive predictive value of CDU in endoleak detection was determined. Statistics were performed by using the paired t test; a P value <.05 was considered significant. Kappa statistic was used to assess the correlation between CDU and CT in identifying endoleaks. The correlation between CT and CDU in AAA size measurements as well as in serial size measurements was also determined. RESULTS Four hundred ninety-five same-day CT and CDU examinations were reviewed in 281 patients. Patients had an average follow-up of 34.6 months (range, 1 to 72 months). Thirty-five leaks were identified among the patients studied (12.4% overall). In comparison with CT, diagnosis of endoleak with ultrasound scanning was associated with a sensitivity of 42.9%, specificity of 96.0%, positive predictive value of 53.9%, and negative predictive value of 93.9%. The correlation between the two modalities was modest (kappa statistic 0.427). The minor axis transverse diameter as measured by ultrasound and CT scans (4.81 +/- 1.1 cm on CT and 4.55 +/- 1.1 cm on ultrasound) correlated closely (r =.93, P <.001.) Seventy percent of paired studies differed by < or =5 mm. Changes in aneurysm size throughout follow-up were -.29 +/-.71 cm on CT scan -.34 +/-.57 cm on duplex ultrasound scan. The correlation coefficient was.65 (P <.001). There was no significant difference in the change as measured by either modality on the paired t test. CONCLUSIONS Although CDU demonstrates a high degree of correlation with CT scan in determining aneurysm size change over time, it has a low sensitivity and positive predictive value in endoleak detection. In the hospital vascular laboratory at a large tertiary care center, CDU cannot effectively replace CT scan in surveillance after EVAR.


Journal of Vascular Surgery | 2003

Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair

Ellen D. Dillavou; Satish C. Muluk; Robert Y. Rhee; Edith Tzeng; Jonathan D. Woody; NavYash Gupta; Michel S. Makaroun

OBJECTIVES Poor outcomes have been reported with endovascular aneurysm repair (EVAR) in patients with hostile neck anatomy. Unsupported endografts with active fixation may offer certain advantages in this situation. We compared EVAR results using the Ancure (Guidant) endograft in patients with and without hostile neck anatomy. METHODS Records of EVAR patients from October 1999 to July 2002 at a tertiary care hospital were retrospectively reviewed from a division database. Patients with elective open abdominal aortic aneurysm (AAA) repair during the same period were reviewed to determine those unsuitable for EVAR. Hostile neck anatomy, assessed by computer tomography (CT) scans and angiograms, was defined as one or more of the following: (1) neck length </=10 mm, (2) focal bulge in the neck >3 mm, (3) >2-mm reverse taper within 1 cm below the renal arteries, (4) neck thrombus > or =50% of circumference, and (5) angulation > or =60 degrees within 3 cm below renals. RESULTS Three hundred and twenty-two patients underwent EVAR with an average follow-up of 18 months. Patients in Phase II trials (n = 41), repaired with other graft types (n = 48), or without complete anatomic records (n = 27) were excluded. Demographics and co-morbidities were similar in the 115 good-neck (GN) and 91 bad-neck (BN) patients except for age (mean, 72.9 years GN vs 75.7 BN; P = 0.13), gender (11% female GN vs 22% BN; P =.04); neck length (mean, 21.8 mm GN vs 14.4 mm BN: P <.001), and angulation (mean, 22 degrees GN vs 40 degrees BN; (P <.001). Perioperative mortality (0 GN vs 1.1% BN), late mortality (5.2% GN vs 4.4% BN), all endoleaks (19.1% GN vs 17.6% BN), proximal endoleaks (0.8% GN vs 2.1% BN), and graft migration (0 for both groups) did not reach statistical significance. Neck anatomy precluded EVAR in 106 of 165 (64%) patients with open AAA. CONCLUSIONS Unsupported endografts with active fixation can yield excellent results in treating many medically compromised patients with hostile neck anatomy. Nonetheless, an unsuitable neck remains the most frequent cause for open abdominal AAA.


Journal of Vascular Surgery | 1999

Thrombin injection versus compression of femoral artery pseudoaneurysms

Bradley S. Taylor; Robert Y. Rhee; Satish C. Muluk; Jeffrey Trachtenberg; Doreen Walters; David L. Steed; Michel S. Makaroun

OBJECTIVE The compression of femoral artery pseudoaneurysms is a time consuming, painful, and sometimes unsuccessful procedure. Thrombin injection has been advocated as a superior alternative. In this study, we compare our experiences with both techniques. METHODS All the records of femoral artery false aneurysms that were treated in the vascular laboratory from January 1996 to April 1999 were retrospectively reviewed. Treatment with ultrasound scan-guided compression was compared with treatment with dilute thrombin injection (100 U/mL). RESULTS Both groups had similar demographics and aneurysm sizes (P >.2). Of the pseudoaneursyms, 88% were caused by cardiac catheterization and the others were the results of femoral artery access for cardiac surgery (6%), arteriography (5%), and renal dialysis (1%). Compression was successful in 25 of 40 patients (63%). Nine persistent aneurysms necessitated operation, and six were treated successfully with thrombin injection. Primary thrombin injection successfully obliterated 21 pseudoaneurysms in 23 patients. Overall, 27 of 29 pseudoaneurysms were treated successfully with thrombin injection (93%). Thrombosis occurred within seconds of the thrombin injection and required, on average, 300 units of thrombin (100 to 600 units). The patients who underwent successful compression required an average of 37 minutes of compression (range, 5 to 70 minutes) and required analgesia on several occasions. No patients in the thrombin group required analgesia or sedation. Neither group had complications. A cost analysis shows that thrombin treatment results in considerable savings in vascular laboratory resource use but not in overall hospital expenditures. CONCLUSION Ultrasound scan-guided thrombin injection is a safe, fast, and painless procedure that completely obliterates femoral artery pseudoaneurysms. The shift from compressive therapy to thrombin injection reduces vascular laboratory use and is less expensive, although it does not significantly impact hospital costs.


Computer Methods in Biomechanics and Biomedical Engineering | 2008

Wall stress and flow dynamics in abdominal aortic aneurysms: finite element analysis vs. fluid–structure interaction

Christine M. Scotti; Jorge Jimenez; Satish C. Muluk; Ender A. Finol

Abdominal aortic aneurysm (AAA) rupture is the clinical manifestation of an induced force exceeding the resistance provided by the strength of the arterial wall. This force is most frequently assumed to be the product of a uniform luminal pressure acting along the diseased wall. However fluid dynamics is a known contributor to the pathogenesis of AAAs, and the dynamic interaction of blood flow and the arterial wall represents the in vivo environment at the macro-scale. The primary objective of this investigation is to assess the significance of assuming an arbitrary estimated peak fluid pressure inside the aneurysm sac for the evaluation of AAA wall mechanics, as compared with the non-uniform pressure resulting from a coupled fluid–structure interaction (FSI) analysis. In addition, a finite element approach is utilised to estimate the effects of asymmetry and wall thickness on the wall stress and fluid dynamics of ten idealised AAA models and one non-aneurysmal control. Five degrees of asymmetry with uniform and variable wall thickness are used. Each was modelled under a static pressure-deformation analysis, as well as a transient FSI. The results show that the inclusion of fluid flow yields a maximum AAA wall stress up to 20% higher compared to that obtained with a static wall stress analysis with an assumed peak luminal pressure of 117 mmHg. The variable wall models have a maximum wall stress nearly four times that of a uniform wall thickness, and also increasing with asymmetry in both instances. The inclusion of an axial stretch and external pressure to the computational domain decreases the wall stress by 17%.


Journal of Vascular Surgery | 1999

Progression of asymptomatic carotid stenosis: A natural history study in 1004 patients ☆ ☆☆

Satish C. Muluk; Visala S. Muluk; Hiroatsu Sugimoto; Robert Y. Rhee; Jeffrey Trachtenberg; David L. Steed; Frederic Jarrett; Marshall W. Webster; Michel S. Makaroun

PURPOSE The purpose of this study was to delineate the natural history of the progression of asymptomatic carotid stenosis. METHODS In a 10-year period, 1701 carotid arteries in 1004 patients who were asymptomatic were studied with serial duplex scans (mean follow-up period, 28 months; mean number of scans, 2.9/patient). At each visit, stenoses of the internal carotid artery (ICA) and the external carotid artery (ECA) were categorized as none (0 to 14%), mild (15% to 49%), moderate (50% to 79%), severe (80% to 99%), preocclusive, or occluded. Progression was defined as an increase in ICA stenosis to >/=50% for carotid arteries with a baseline of <50% or as an increase to a higher category of stenosis if the baseline stenosis was >/=50%. The Cox proportional hazards model was used for data analysis. RESULTS The risk of progression of ICA stenosis increased steadily with time (annualized risk of progression, 9.3%). With multivariate modeling, the four most important variables that affected the progression (P <.02) were baseline ipsilateral ICA stenosis >/=50% (relative risk [RR], 3.34), baseline ipsilateral ECA stenosis >/=50% (RR, 1.51), baseline contralateral ICA stenosis >/=50% (RR, 1.41), and systolic pressure more than 160 mm Hg (RR, 1. 37). Ipsilateral neurologic ischemic events (stroke/transient ischemic attack) occurred in association with 14.0% of the carotid arteries that were studied. The progression of ICA stenosis correlated with these events (P <.001), but baseline ICA stenosis was not a significant predictor. CONCLUSION In contrast to recently published studies, we found that the risk of progression of carotid stenosis is substantial and increases steadily with time. Baseline ICA stenosis was the most important predictor of the progression, but baseline ECA stenosis also was identified as an important independent predictor. Contralateral ICA stenosis and systolic hypertension were additional significant predictors. We found further that the progression of ICA stenosis correlated with ischemic neurologic events but not baseline stenosis. The data provide justification for the use of serial duplex scans to follow carotid stenosis and suggest that different follow-up intervals may be appropriate for different patient subgroups.


Journal of Biomechanical Engineering-transactions of The Asme | 2009

Three-Dimensional Geometrical Characterization of Abdominal Aortic Aneurysms: Image-Based Wall Thickness Distribution

Giampaolo Martufi; Elena S. Di Martino; Cristina H. Amon; Satish C. Muluk; Ender A. Finol

The clinical assessment of abdominal aortic aneurysm (AAA) rupture risk is based on the quantification of AAA size by measuring its maximum diameter from computed tomography (CT) images and estimating the expansion rate of the aneurysm sac over time. Recent findings have shown that geometrical shape and size, as well as local wall thickness may be related to this risk; thus, reliable noninvasive image-based methods to evaluate AAA geometry have a potential to become valuable clinical tools. Utilizing existing CT data, the three-dimensional geometry of nine unruptured human AAAs was reconstructed and characterized quantitatively. We propose and evaluate a series of 1D size, 2D shape, 3D size, 3D shape, and second-order curvature-based indices to quantify AAA geometry, as well as the geometry of a size-matched idealized fusiform aneurysm and a patient-specific normal abdominal aorta used as controls. The wall thickness estimation algorithm, validated in our previous work, is tested against discrete point measurements taken from a cadaver tissue model, yielding an average relative difference in AAA wall thickness of 7.8%. It is unlikely that any one of the proposed geometrical indices alone would be a reliable index of rupture risk or a threshold for elective repair. Rather, the complete geometry and a positive correlation of a set of indices should be considered to assess the potential for rupture. With this quantitative parameter assessment, future research can be directed toward statistical analyses correlating the numerical values of these parameters with the risk of aneurysm rupture or intervention (surgical or endovascular). While this work does not provide direct insight into the possible clinical use of the geometric parameters, we believe it provides the foundation necessary for future efforts in that direction.


Journal of Vascular Surgery | 1996

Diagnosis and treatment of thoracic aortic intramural hematoma

Satish C. Muluk; John A. Kaufman; David F. Torchiana; Jonathan P. Gertler; Richard P. Cambria

PURPOSE This report reviews our recent experience with nine patients who had intramural hematoma of the thoracic aorta. METHODS This was a retrospective study of all patients who had intramural hematoma at our institution from 1989 to 1994. Patients who had identifiable intimal flap, tear, or penetrating aortic ulcer were excluded from the study. RESULTS Among these nine elderly patients (mean age, 76 years), the most common presentation was chest or back pain. Intramural hematoma was diagnosed by a variety of high-resolution imaging techniques. The descending thoracic aorta alone was involved in seven patients, whereas the ascending aorta was affected in the other two patients. One patient had evidence of an aneurysm (5.0 cm diameter) in the region of the hematoma. All patients were initially managed nonsurgically with blood pressure control. Both patients who had ascending aortic involvement had progression of aortic hematoma, which resulted in death in one case and in successful surgery in the other. Six of the seven patients who had descending aortic involvement alone were successfully managed without aortic surgery. The patient who had intramural hematoma and associated aortic aneurysm, however, had severe, recurrent pain and underwent successful aortic replacement. Another patient had recurrent pain associated with hypertension, but was successfully managed nonsurgically with antihypertensive therapy. All eight survivors are doing well at a median follow-up of 19 months. CONCLUSIONS Intramural hematoma appears to be a distinct entity, although overlap with aortic dissection or penetrating aortic ulcer exists. Aggressive control of blood pressure with intensive care unit monitoring has been our initial management. Patients who have involvement of the descending thoracic aorta alone can frequently be managed without surgery in the absence of coexisting aneurysmal dilatation or disease progression. Our experience suggests that a more aggressive approach with early surgery is warranted in patients who have ascending aortic involvement or those who have coexisting aneurysm and intramural hematoma.


Journal of Vascular Surgery | 1997

Utility of clinical pathway and prospective case management to achieve cost and hospital stay reduction for aortic aneurysm surgery at a tertiary care hospital

Satish C. Muluk; Lisa Painter; Saba Sile; Robert Y. Rhee; Michel S. Makaroun; David L. Steed; Marshall W. Webster

PURPOSE We reviewed our experience with a clinical pathway instituted in December 1993 for all nonurgent abdominal aortic aneurysm (AAA) surgery. METHODS We analyzed a reference group of 49 consecutive pre-pathway AAA patients (group I) and the 44 patients enrolled in the first year of the pathway (group II). On the basis of the interim review of data collected during the first year, pathway modifications were made, and 34 patients enrolled after these modifications (group III) were also analyzed. RESULTS Comparison of groups I and II showed that institution of the pathway resulted in a marginally significant reduction in mean charges of 14.7% (p = 0.09), and a slight fall in mean length of stay (LOS) (13.8 vs 13.1 days, NS) and mortality rate (4.1% vs 2.3%, NS). For group II, a significant correlate (p < 0.05) of increased charges was fluid overload as diagnosed by chest radiograph. This recognition led to active efforts to reduce perioperative fluid administration. Comparison of groups II and III revealed that the practice modifications led to marked reduction in the incidence of fluid overload (73% vs 24%; p < 0.01), mean charges (30.4% reduction; p < 0.05), mean LOS (13.1 vs 10.2 days; p < 0.05), and median LOS (11 vs 8 days). Multiple regression analysis of all pathway patients showed that preoperative renal insufficiency is a significant predictor of both increased LOS (p < 0.01) and charges (p < 0.01), but that age, sex, and coronary disease were not predictive. Of the postoperative parameters analyzed, important correlates of increased charges were acute renal failure (p < 0.01) and fluid overload (p < 0.01). CONCLUSIONS Institution of a clinical pathway for AAA repair resulted in significant charge reduction and a slight reduction in stay. Practice modifications based on interim data analysis yielded further significant reductions in charges and LOS, with overall per-patient charge savings (group I vs III) of 40.6% (p < 0.05) and overall LOS reduction of 3.5 days (p < 0.05). The reduction in actual charges was seen despite an overall increase in the hospital rate structure. Comparing groups I, II, and III, we found no indication of increasing mortality rate. Ongoing analysis has identified correlates of increased charges, potentially permitting identification of high-cost subgroups and more focused cost-control efforts. Rather than restricting management, clinical pathways with periodic data analysis may improve quality of care.


Journal of Vascular Surgery | 1994

Presentation and patterns of aortic aneurysms in young patients

Satish C. Muluk; Jonathan P. Gertler; David C. Brewster; Richard P. Cambria; Glenn M. LaMuraglia; Ashby C. Moncure; R. Clement Darling; William M. Abbott

PURPOSE Although aortic aneurysm (AA) is primarily a disease of older age groups, younger (< 51 years) patients infrequently are admitted requiring AA surgery. We sought to compare the characteristics of these patients with those of a randomly selected group of older patients with AA. METHODS We identified 26 patients with AA (group I) under age 51 (mean age 44.8) treated surgically between 1977 and 1993, after excluding patients with acute aortic dissection, traumatic pseudoaneurysms, and ascending or arch aneurysms, and compared them with 75 randomly selected patients with AA between the ages of 65 and 75 (mean age 70.3) who were surgically treated during the same time period (group II). RESULTS Prevalence of hypertension, diabetes, coexisting heart, kidney, or occlusive peripheral vascular disease was similar between the two groups, and familial aneurysm rates and sex distribution did not differ significantly. More patients in group I had symptoms at the time of presentation (46% vs 6.7%, p < 0.001), and they also had larger AAs (6.9 cm vs 6.0 cm, p = 0.01). Definable causes of aneurysmal disease, such as Takayasus, Cogans, and Marfan syndromes, were more common among the young patients (23% vs 0%, p = 0.01), but most (77%) young patients did not have an identifiable syndrome associated with their aneurysm disease. Group I had a marked shift toward proximal aneurysms, defined as involvement of juxtarenal, suprarenal, or thoracoabdominal aorta (46% vs 18% in group II, p < 0.01). This difference persisted even when aneurysms associated with the above syndromes were excluded from consideration (p = 0.02). Cigarette smoking was much more common among the young patients (83% vs 51% in group II, p < 0.01). Smoking in group II was associated with more extensive aneurysm disease (p = 0.04). CONCLUSIONS Aneurysmal disease presenting in the young adult is more likely to be symptomatic and associated with more proximal aortic involvement than aneurysmal disease in older patients. Smoking appears to play an important role in the pathogenesis of aneurysmal disease in the young patient and was associated in our study with more proximal aneurysms among older patients. A subgroup of patients at risk for early and aggressive aneurysm disease is suggested by these data.

Collaboration


Dive into the Satish C. Muluk's collaboration.

Top Co-Authors

Avatar

Ender A. Finol

Carnegie Mellon University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Joseph L. Grisafi

Allegheny General Hospital

View shared research outputs
Top Co-Authors

Avatar

Judy Shum

Carnegie Mellon University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Robert Y. Rhee

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar

David L. Steed

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rodeen Rahbar

Allegheny General Hospital

View shared research outputs
Researchain Logo
Decentralizing Knowledge