Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Satish K. Garg is active.

Publication


Featured researches published by Satish K. Garg.


The New England Journal of Medicine | 2013

Threshold-Based Insulin-Pump Interruption for Reduction of Hypoglycemia

Richard M. Bergenstal; David C. Klonoff; Satish K. Garg; Bruce W. Bode; Melissa Meredith; Robert Slover; Andrew J. Ahmann; John B. Welsh; Scott Lee; Francine R. Kaufman

BACKGROUND The threshold-suspend feature of sensor-augmented insulin pumps is designed to minimize the risk of hypoglycemia by interrupting insulin delivery at a preset sensor glucose value. We evaluated sensor-augmented insulin-pump therapy with and without the threshold-suspend feature in patients with nocturnal hypoglycemia. METHODS We randomly assigned patients with type 1 diabetes and documented nocturnal hypoglycemia to receive sensor-augmented insulin-pump therapy with or without the threshold-suspend feature for 3 months. The primary safety outcome was the change in the glycated hemoglobin level. The primary efficacy outcome was the area under the curve (AUC) for nocturnal hypoglycemic events. Two-hour threshold-suspend events were analyzed with respect to subsequent sensor glucose values. RESULTS A total of 247 patients were randomly assigned to receive sensor-augmented insulin-pump therapy with the threshold-suspend feature (threshold-suspend group, 121 patients) or standard sensor-augmented insulin-pump therapy (control group, 126 patients). The changes in glycated hemoglobin values were similar in the two groups. The mean AUC for nocturnal hypoglycemic events was 37.5% lower in the threshold-suspend group than in the control group (980 ± 1200 mg per deciliter [54.4 ± 66.6 mmol per liter] × minutes vs. 1568 ± 1995 mg per deciliter [87.0 ± 110.7 mmol per liter] × minutes, P<0.001). Nocturnal hypoglycemic events occurred 31.8% less frequently in the threshold-suspend group than in the control group (1.5 ± 1.0 vs. 2.2 ± 1.3 per patient-week, P<0.001). The percentages of nocturnal sensor glucose values of less than 50 mg per deciliter (2.8 mmol per liter), 50 to less than 60 mg per deciliter (3.3 mmol per liter), and 60 to less than 70 mg per deciliter (3.9 mmol per liter) were significantly reduced in the threshold-suspend group (P<0.001 for each range). After 1438 instances at night in which the pump was stopped for 2 hours, the mean sensor glucose value was 92.6 ± 40.7 mg per deciliter (5.1 ± 2.3 mmol per liter). Four patients (all in the control group) had a severe hypoglycemic event; no patients had diabetic ketoacidosis. CONCLUSIONS This study showed that over a 3-month period the use of sensor-augmented insulin-pump therapy with the threshold-suspend feature reduced nocturnal hypoglycemia, without increasing glycated hemoglobin values. (Funded by Medtronic MiniMed; ASPIRE ClinicalTrials.gov number, NCT01497938.).


The Lancet | 2012

Insulin degludec, an ultra-longacting basal insulin, versus insulin glargine in basal-bolus treatment with mealtime insulin aspart in type 1 diabetes (BEGIN Basal-Bolus Type 1): a phase 3, randomised, open-label, treat-to-target non-inferiority trial

Simon Heller; John B. Buse; Miles Fisher; Satish K. Garg; Michel Marre; Ludwig Merker; Eric Renard; David Russell-Jones; Areti Philotheou; Ann Marie Ocampo Francisco; Huiling Pei; Bruce W. Bode

BACKGROUND Intensive basal-bolus insulin therapy has been shown to improve glycaemic control and reduce the risk of long-term complications that are associated with type 1 diabetes mellitus. Insulin degludec is a new, ultra-longacting basal insulin. We therefore compared the efficacy and safety of insulin degludec and insulin glargine, both administered once daily with mealtime insulin aspart, in basal-bolus therapy for type 1 diabetes. METHODS In an open-label, treat-to-target, non-inferiority trial, undertaken at 79 sites (hospitals and centres) in six countries, adults (aged ≥18 years) with type 1 diabetes (glycated haemoglobin [HbA(1c)] ≤10% [86 mmol/mol]), who had been treated with basal-bolus insulin for at least 1 year, were randomly assigned in a 3:1 ratio, with a computer-generated blocked allocation sequence, to insulin degludec or insulin glargine without stratification by use of a central interactive response system. The primary outcome was non-inferiority of degludec to glargine, assessed as a reduction in HbA(1c) after 52 weeks, with the intention-to-treat analysis. This trial is registered with ClinicalTrials.gov, number NCT00982228. FINDINGS Of 629 participants, 472 were randomly assigned to insulin degludec and 157 to insulin glargine; all were analysed in their respective treatment groups. At 1 year, HbA(1c) had fallen by 0·40% points (SE 0·03) and 0·39% points (0·07), respectively, with insulin degludec and insulin glargine (estimated treatment difference -0·01% points [95% CI -0·14 to 0·11]; p<0·0001 for non-inferiority testing) and 188 (40%) and 67 (43%) participants achieved a target HbA(1c) of less than 7% (<53 mmol/mol). Rates of overall confirmed hypoglycaemia (plasma glucose <3·1 mmol/L or severe) were similar in the insulin degludec and insulin glargine groups (42·54 vs 40·18 episodes per patient-year of exposure; estimated rate ratio [degludec to glargine] 1·07 [0·89 to 1·28]; p=0·48). The rate of nocturnal confirmed hypoglycaemia was 25% lower with degludec than with glargine (4·41 vs 5·86 episodes per patient-year of exposure; 0·75 [0·59 to 0·96]; p=0·021). Overall serious adverse event rates (14 vs 16 events per 100 patient-years of exposure) were similar for the insulin degludec and insulin glargine groups. INTERPRETATION Insulin degludec might be a useful basal insulin for patients with type 1 diabetes because it provides effective glycaemic control while lowering the risk of nocturnal hypoglycaemia, which is a major limitation of insulin therapy. FUNDING Novo Nordisk.


Biosensors and Bioelectronics | 2001

Clinical evaluation of the GlucoWatch® biographer: a continual, non-invasive glucose monitor for patients with diabetes ☆

Michael J. Tierney; Janet Tamada; Russell O. Potts; L. Jovanovic; Satish K. Garg

A device providing frequent, automatic, and non-invasive glucose measurements for persons with diabetes has been developed: the GlucoWatch biographer. This device extracts glucose through intact skin via reverse iontophoresis where it is detected by an amperometric biosensor. The biographer can provide glucose readings every 20 min for 12 h. The performance of this device was evaluated in two large clinical studies in a controlled clinical environment (n=231), and the home environment (n=124). Accuracy of the biographer was evaluated by comparing the automatic biographer readings to serial finger-stick blood glucose (BG) measurements. Biographer performance was comparable in both environments. Mean difference between biographer and finger-stick measurements was -0.01 and 0.26 mmol l(-1) for the clinical and home environments, respectively. The mean absolute value of the relative difference was 1.06 and 1.18 mmol l(-1) for the same studies. Correlation coefficient (r) between biographer and finger-stick measurements was 0.85 and 0.80 for the two studies. In both studies, over 94% of the biographer readings were in the clinically acceptable A+B region of the Clarke Error Grid. A slight positive bias is observed for the biographer readings at low BG levels. Biographer accuracy is relatively constant over all rates of BG changes, except when BG decreases more than 10 mmol l(-1) h(-1), which occurred for only 0.2% of points in the home environment study. Biographer precision, as measured by CV%, is approx. 10%. Skin irritation, characterized by erythema and edema, was either non-existent or mild in >90% of subjects and resolved in virtually all subjects without treatment in several days.


Diabetes Care | 2006

Relationship of Fasting and Hourly Blood Glucose Levels to HbA1c Values: Safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor

Satish K. Garg; Lois Jovanovic

OBJECTIVE—In this study, we evaluated the safety and efficacy of 7-day transcutaneous, real-time, continuous glucose monitoring (CGM) in subjects with insulin-requiring diabetes. RESEARCH DESIGN AND METHODS—Eighty-six subjects were enrolled at five U.S. centers. Subjects wore a sensor inserted under the skin of the abdomen for 7 days during each of three consecutive periods. Data were blinded during period 1 and unblinded during periods 2 and 3. RESULTS—Of the 6,811 matched self-monitoring of blood glucose to sensor values prospectively analyzed, 97.2% fell in the Clarke error grid zones A and B, and median absolute relative difference was 11.4%. After unblinding, subjects reduced time spent at <55 mg/dl by 0.3 h/day, reduced time spent at >240 mg/dl by 1.5 h/day, and increased time in the target zone (81–140 mg/dl) by 1.4 h/day (P < 0.05 for all three comparisons). Improvements were seen in both types 1 and 2 diabetes and with use of both multiple daily injections and continuous subcutaneous insulin infusion. Modal day graphs were generated in six groups of subjects based on HbA1c (A1C) (≤6, 6–7, 7–8, 8–9, 9–10, and >10%). Mean glucose levels from midnight to 7:00 a.m. (fasting and dawn phenomenon periods) were only normal for subjects with A1C ≤6%. All other groups were hyperglycemic during this and all periods. Reductions in overall mean glucose were achieved for the four highest A1C groupings with unblinded device use. CONCLUSIONS—This is the first report of a real-time, transcutaneous glucose sensor that functioned for 7 days. The use of CGM in the unblinded phase resulted in improvements in target-range glycemia across all A1C values.


BMJ | 1999

Genetic determination of islet cell autoimmunity in monozygotic twin, dizygotic twin, and non-twin siblings of patients with type 1 diabetes: prospective twin study

Maria J. Redondo; Marian Rewers; Liping Yu; Satish K. Garg; Colleen Pilcher; Robert Elliott; George S. Eisenbarth

Abstract Objective: To test the hypothesis that non-diabetic dizygotic and monozygotic twin siblings of patients with type 1 diabeteshave a similar high prevalence of islet cell autoantibodies, thus suggesting that islet cell autoimmunity is mainly environmentally determined. Design: Prospective twin study. Setting: Two specialist centres for diabetes in the United States. Participants: Non-diabetic monozygotic twin (n=53), dizygotic twin (n=30), and non-twin (n=149) siblings of patients with type 1 diabetes; 101 controls. Main outcome measures: Analysis of progression to diabetes and expression of anti-islet autoantibodies. Results: Monozygotic twin siblings had a higher risk of progression to diabetes (12/53) than dizygotic twin siblings (0/30; P<0.005). At the last follow up 22 (41.5%) monozygotic twin siblings expressed autoantibodies compared with 6 (20%) dizygotic twin siblings (P<0.05), 16 (10.7%) non-twin siblings (P<0.0001), and 6 (5.9%) controls (P<0.0001). Monozygotic twin siblings expressed multiple (≤2) antibodies more often than dizygotic twin siblings (10/38 v 1/23; P<0.05). By life table analysis the probability of developing positive autoantibodies was higher among the monozygotic twin siblings bearing the diabetes associated HLA DQ8/DQ2 genotype than in those without this genotype (64.2% (95% confidence interval 32.5% to 96%) v 23.5% (7% to 40%) at 10 years of discordance; P<0.05). Conclusion: Monozygotic and dizygotic twins differ in progression to diabetes and expression of islet cell autoantibodies. Dizygotic twin siblings are similar to non-twin siblings. These two observations suggest that genetic factors play an important part in determination of islet cell autoimmunity, thus rejecting the hypothesis. In addition, there is a high penetrance of islet cell autoimmunity in DQ8/DQ2 monozygotic twin siblings.


Diabetes Technology & Therapeutics | 2013

Recommendations for Standardizing Glucose Reporting and Analysis to Optimize Clinical Decision Making in Diabetes: The Ambulatory Glucose Profile (AGP)

Richard M. Bergenstal; Andrew J. Ahmann; Timothy L. Bailey; Roy W. Beck; Joan Bissen; Bruce Buckingham; Larry C. Deeb; Robert H. Dolin; Satish K. Garg; Robin Goland; Irl B. Hirsch; David C. Klonoff; Davida F. Kruger; Glenn Matfin; Roger S. Mazze; Beth A. Olson; Christopher G. Parkin; Anne L. Peters; Margaret A. Powers; Henry Rodriguez; Phil Southerland; Ellie S. Strock; William V. Tamborlane; David M. Wesley

Abstract Underutilization of glucose data and lack of easy and standardized glucose data collection, analysis, visualization, and guided clinical decision making are key contributors to poor glycemic control among individuals with type 1 diabetes. An expert panel of diabetes specialists, facilitated by the International Diabetes Center and sponsored by the Helmsley Charitable Trust, met in 2012 to discuss recommendations for standardization of analysis and presentation of glucose monitoring data, with the initial focus on data derived from CGM systems. The panel members were introduced to a universal software report, the Ambulatory Glucose Profile (AGP), and asked to provide feedback on its content and functionality, both as a research tool and in clinical settings. This paper provides a summary of the topics and issues discussed during the meeting and presents recommendations from the expert panel regarding the need to standardize glucose profile summary metrics and the value of a uniform glucose report to aid clinicians, researchers, and patients.


JAMA | 2016

Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes.

Richard M. Bergenstal; Satish K. Garg; Stuart A. Weinzimer; Bruce Buckingham; Bruce W. Bode; William V. Tamborlane; Francine R. Kaufman

Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes Closed-loopartificialpancreastechnologyusesacontrolalgorithm to automatically adjust insulin delivery based on subcutaneous sensor data to improve diabetes management. Currently available systems stop insulin in response to existing1 or predicted2 low sensor glucose values, whereas hybrid closed-loop systems combine user-delivered premeal boluses with automatic interprandial insulin delivery.3 This study investigated the safety of a hybrid closed-loop system in patients with type 1 diabetes.


The Journal of Pediatrics | 2003

Reduced hypoglycemic episodes and improved glycemic control in children with type 1 diabetes using insulin glargine and neutral protamine hagedorn insulin

H.Peter Chase; Brenner Dixon; Jerusha Pearson; Rosanna Fiallo-Scharer; Philippe Walravens; Georgeanna Klingensmith; Marian Rewers; Satish K. Garg

OBJECTIVE The purpose of this study was to evaluate the use of a new long-acting basal insulin, insulin glargine (IG), in children with type 1 diabetes. Study design Data from 114 subjects, age 2 to 18 years (mean, 12.2 years; 54 boys, 60 girls), were collected for 9 months before and 9 months after IG treatment. During IG therapy, all subjects received morning neutral protamine Hagedorn insulin (given with insulin lispro; Humalog) to provide daytime insulin coverage. The numbers of nonsevere and severe hypoglycemic events, hemoglobin A1c values, body weight, and daily insulin dose were recorded at each clinic visit. RESULTS The mean (+/-1 SEM) frequency of nonsevere hypoglycemic events per week decreased from 2.0+/-0.1 to 1.3+/-0.1 (P<.001). Severe hypoglycemic episodes were reduced from a total of 22 in the 9 months before IG to nine in the 9 months after IG. Severe nocturnal events were similarly reduced from 14 to four episodes. The mean (+/-1 SEM) hemoglobin A1c levels were 9.6+/-0.1% (baseline), 9.4+/-0.1% at 3 months (P=.18), 9.3+/-0.1% at 6 months (P=.03), and 9.3+/-0.1% at 9 months (P=.01). CONCLUSION Insulin glargine therapy can reduce hypoglycemic episodes in children and adolescents with suboptimal glucose control without jeopardizing glycemic control.


Diabetic Medicine | 2002

Post-prandial glucose excursions following four methods of bolus insulin administration in subjects with Type 1 diabetes

H.P. Chase; T. Mackenzie; M. M. Hansen; Satish K. Garg

Aims To determine if one method of short‐acting insulin bolus administration is superior to other methods in managing a meal high in carbohydrates, calories and fat.


Diabetes Technology & Therapeutics | 2012

Reduction in Duration of Hypoglycemia by Automatic Suspension of Insulin Delivery: The In-Clinic ASPIRE Study

Satish K. Garg; Ronald L. Brazg; Timothy S. Bailey; Bruce Buckingham; Robert H. Slover; David C. Klonoff; John H. Shin; John B. Welsh; Francine R. Kaufman

BACKGROUND The efficacy of automatic suspension of insulin delivery in induced hypoglycemia among subjects with type 1 diabetes was evaluated. SUBJECTS AND METHODS In this randomized crossover study, subjects used a sensor-augmented insulin pump system with a low glucose suspend (LGS) feature that automatically stops insulin delivery for 2 h following a sensor glucose (SG) value ≤70 mg/dL. Subjects fasted overnight and exercised until their plasma glucose (measured with the YSI 2300 STAT Plus™ glucose and lactate analyzer [YSI Life Sciences, Yellow Springs, OH]) value reached ≤85 mg/dL on different occasions separated by washout periods lasting 3-10 days. Exercise sessions were done with the LGS feature turned on (LGS-On) or with continued insulin delivery regardless of SG value (LGS-Off). The order of LGS-On and LGS-Off sessions was randomly assigned. YSI glucose data were used to compare the duration and severity of hypoglycemia from successful LGS-On and LGS-Off sessions and to estimate the risk of rebound hyperglycemia after pump suspension. RESULTS Fifty subjects attempted 134 sessions, 98 of which were successful. The mean±SD hypoglycemia duration was less during LGS-On than during LGS-Off sessions (138.5±76.68 vs. 170.7±75.91 min, P=0.006). During LGS-On compared with LGS-Off sessions, mean nadir YSI glucose was higher (59.5±5.72 vs. 57.6±5.69 mg/dL, P=0.015), as was mean end-observation YSI glucose (91.4±41.84 vs. 66.2±13.48 mg/dL, P<0.001). Most (53.2%) end-observation YSI glucose values in LGS-On sessions were in the 70-180 mg/dL range, and none was >250 mg/dL. CONCLUSIONS Automatic suspension of insulin delivery significantly reduced the duration and severity of induced hypoglycemia without causing rebound hyperglycemia.

Collaboration


Dive into the Satish K. Garg's collaboration.

Top Co-Authors

Avatar

H. Peter Chase

University of Colorado Denver

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Irl B. Hirsch

University of Washington Medical Center

View shared research outputs
Top Co-Authors

Avatar

Marian Rewers

University of Colorado Denver

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

John B. Buse

University of North Carolina at Chapel Hill

View shared research outputs
Top Co-Authors

Avatar

Anne L. Peters

University of Southern California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge