Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Scott A. Smith is active.

Publication


Featured researches published by Scott A. Smith.


Mass Spectrometry Reviews | 2011

Tandem mass spectrometry strategies for phosphoproteome analysis

Amanda M. Palumbo; Scott A. Smith; Christine L. Kalcic; Marcos Dantus; Paul M. Stemmer; Gavin E. Reid

Protein phosphorylation is involved in nearly all essential biochemical pathways and the deregulation of phosphorylation events has been associated with the onset of numerous diseases. A multitude of tandem mass spectrometry (MS/MS) and multistage MS/MS (i.e., MS(n) ) strategies have been developed in recent years and have been applied toward comprehensive phosphoproteomic analysis, based on the interrogation of proteolytically derived phosphopeptides. However, the utility of each of these MS/MS and MS(n) approaches for phosphopeptide identification and characterization, including phosphorylation site localization, is critically dependant on the properties of the precursor ion (e.g., polarity and charge state), the specific ion activation method that is employed, and the underlying gas-phase ion chemistries, mechanisms and other factors that influence the gas-phase fragmentation behavior of phosphopeptide ions. This review therefore provides an overview of recent studies aimed at developing an improved understanding of these issues, and highlights the advantages and limitations of both established (e.g., CID) and newly maturing (e.g., ECD, ETD, photodissociation, etc.) yet complementary, ion activation techniques. This understanding is expected to facilitate the continued refinement of existing MS/MS strategies, and the development of novel MS/MS techniques for phosphopeptide analysis, with great promise in providing new insights into the role of protein phosphorylation on normal biological function, and in the onset and progression of disease.


Analyst | 2008

Surface effects and electrochemical cell capacitance in desorption electrospray ionization

Michael Volný; Andre Venter; Scott A. Smith; Marco Pazzi; R. Graham Cooks

Time resolved measurements show that during a desorption electrospray ionization (DESI) experiment, the current initially rises sharply, followed by an exponential decrease to a relatively steady current. When the high voltage on the spray emitter is switched off, the current drops to negative values, suggesting that the direction of current flow in the equivalent DESI circuit is reversed. These data demonstrate that the DESI source behaves as a dc capacitor and that the addition of a surface between the sprayer and the counter electrode in DESI introduces a new electrically active element into the system. The charging and discharging behavior was observed using different surfaces and it could be seen both by making current measurements on a plate at the entrance to the mass spectrometer as well as by measuring ion current in the linear ion trap within the vacuum system of the mass spectrometer. The magnitude of the steady state current obtained without analyte present on the surface is different for different surface materials, and different capacitor time constants of the equivalent RC circuits were calculated for different DESI surfaces. The PTFE surface has by far the greatest time constant and is also able to produce the highest DESI currents. Surface properties play a crucial role in charge transfer during DESI in addition to the effects of the chemical properties of the analyte. It is suggested that surface energy (wettability) is an important factor controlling droplet behavior on the surface. The experimental data are correlated with critical surface tension values of different materials. It is proposed, based on the results presented, that super-hydrophobic materials with extremely high contact angles have the potential to be excellent DESI substrates. It is also demonstrated, using the example of the neurotransmitter dopamine, that the surface charge that develops during a DESI-MS experiment can cause electrochemical oxidation of the analyte.


Journal of the American Society for Mass Spectrometry | 2009

Ion trap mass analysis at high pressure: a theoretical view.

Wei Xu; Qingyu Song; Scott A. Smith; William J. Chappell; Zheng Ouyang

The mass-selective manipulation of ions at elevated pressure, including mass analysis, ion isolation, or excitation, is of great interest for the development of mass spectrometry instrumentation, particularly for systems in which ion traps are employed as mass analyzers or storage devices. While experimental exploration of high-pressure mass analysis is limited by various difficulties, such as ion detection or electrical discharge at high-pressure, theoretical methods have been developed in this work to study ion/neutral collision effects within quadrupole ion traps and to explore their performance at pressures up to 1 Torr. Ion trapping, isolation, excitation, and resonance ejection were investigated over a wide pressure range. The theoretically calculated data were compared with available experimental data for pressures up to 50 mTorr, allowing the prediction of ion trap performance at pressures more than 10 times higher.


Journal of Mass Spectrometry | 2009

Ion trap mass analysis at high pressure: an experimental characterization

Qingyu Song; Wei Xu; Scott A. Smith; Liang Gao; William J. Chappell; R. Graham Cooks; Zheng Ouyang

In recent years, it has become increasingly interesting to understand the performance of mass spectrometers at pressures much higher than those employed with conventional operating conditions. This interest has been driven by several influences, including demand for the development of reduced-power miniature mass spectrometers, desire for improved ion transfer into and through mass spectrometers, enhanced-yield preparative mass separations, and mass filtering at the atmospheric pressure interface. In this study, an instrument was configured to allow for the performance characterization of a rectilinear ion trap (RIT) at pressures up to 50 mtorr with air used as the buffer gas. The mass analysis efficiency, mass resolution, isolation efficiency, and collision-induced dissociation (CID) efficiency were evaluated at pressures ranging from 1 to 50 mtorr. The extent of degradation of mass resolution, isolation efficiency and ion stability as functions of pressure were characterized. Also, the optimal resonance ejection conditions were obtained at various pressures. Operations at 50 mtorr demonstrated improved CID efficiency in addition to peak widths of 2 and 5 m/z units (full width at half-maximum, FWHM) for protonated caffeine (m/z 195) and Ultramark (m/z 1521) respectively.


Journal of the American Society for Mass Spectrometry | 2010

Enhanced Characterization of Singly Protonated Phosphopeptide Ions by Femtosecond Laser-induced Ionization/Dissociation Tandem Mass Spectrometry (fs-LID-MS/MS)

Scott A. Smith; Christine L. Kalcic; Kyle A. Safran; Paul M. Stemmer; Marcos Dantus; Gavin E. Reid

To develop an improved understanding of the regulatory role that post-translational modifications (PTMs) involving phosphorylation play in the maintenance of normal cellular function, tandem mass spectrometry (MS/MS) strategies coupled with ion activation techniques such as collision-induced dissociation (CID) and electron-transfer dissociation (ETD) are typically employed to identify the presence and site-specific locations of the phosphate moieties within a given phosphoprotein of interest. However, the ability of these techniques to obtain sufficient structural information for unambiguous phosphopeptide identification and characterization is highly dependent on the ion activation method employed and the properties of the precursor ion that is subjected to dissociation. Herein, we describe the application of a recently developed alternative ion activation technique for phosphopeptide analysis, termed femtosecond laser-induced ionization/dissociation (fs-LID). In contrast to CID and ETD, fs-LID is shown to be particularly suited to the analysis of singly protonated phosphopeptide ions, yielding a wide range of product ions including a, b, c, x, y, and z sequence ions, as well as ions that are potentially diagnostic of the positions of phosphorylation (e.g., ‘an+1–98’). Importantly, the lack of phosphate moiety losses or phosphate group ‘scrambling’ provides unambiguous information for sequence identification and phosphorylation site characterization. Therefore, fs-LID-MS/MS can serve as a complementary technique to established methodologies for phosphoproteomic analysis.


Analytical Chemistry | 2009

Mass selection of ions from beams using waveform isolation in radiofrequency quadrupoles.

Qingyu Song; Scott A. Smith; Liang Gao; Wei Xu; Michael Volny; Zheng Ouyang; R. Graham Cooks

A waveform isolation method is described for the mass-selective transmission of ions through quadrupole mass filters, and it is implemented on a new tandem mass analyzer instrument. The method features the application of broad-band waveforms comprising appropriate frequencies to cause mass-selective instability in ions of particular mass-to-charge (m/z) and to transmit all others. The experiment is implemented in a tandem quadrupole system in which the first mass filter is a rectilinear ion trap (RIT) operated in a continuous mass-selective mode to transmit ions of ions of one or more arbitrarily selected m/z value(s). The second analyzer was used to verify the quality of the mass selection achieved using the first analyzer via conventional quadrupole ion trap mass-selective instability scanning. A new subtype of product ion tandem mass spectrometry (MS/MS) scan, termed the summed product ion scan, is demonstrated with a mixture of biological compounds. It is used to characterize product ions arising after simultaneous isolation and collisional activation of multiple precursor species, in this case ions of the same analyte generated in different charge states. The summed product ion scan can be useful for enhancing sensitivity for the analyte of interest or for providing more comprehensive information about an analyte than is available by monitoring a single ionized form of the analyte. The analytical performance of the waveform isolation method is tested using simple drug mixtures, and its potential for increasing overall yields in preparative mass spectrometry is explored briefly. It is shown that efficiencies of ca. 70% of ion transfer to a surface for ion soft landing surface can be achieved. The upper mass range is limited by axial acceleration arising from the stretched geometry, and one solution to this problem is provided.


Rapid Communications in Mass Spectrometry | 2013

Femtosecond laser-induced ionization/dissociation tandem mass spectrometry (fsLID-MS/MS) of deprotonated phosphopeptide anions.

Scott A. Smith; Christine L. Kalcic; Li Cui; Gavin E. Reid

RATIONALE Radical-directed dissociation techniques provide structural information which is complementary to that from conventional collision-induced dissociation (CID). The analysis of phosphopeptide anions is warranted due to their relatively acidic character. As femtosecond laser-induced ionization/dissociation tandem mass spectrometry (fsLID-MS/MS) is uniquely initiated by field ionization, an investigation is warranted to determine whether fsLID may provide novel analytical utility for phosphopeptide anions. METHODS Twenty-three synthetic deprotonated phosphopeptide anions were introduced into a three-dimensional quadrupole ion trap mass spectrometer via electrospray ionization. The ion trap was interfaced with a near-IR (802 nm) ultrashort-pulsed (35 fs FWHM) ultrahigh-powered (peak power ~10(14)  W/cm(2)) laser system. Performance comparisons are made with other techniques applied to phosphopeptide anion analysis, including CID, electron detachment dissociation (EDD), negative electron transfer dissociation (NETD), activated electron photodetachment dissociation (activated-EPD), and ultraviolet photodissociation (UVPD). RESULTS FsLID-MS/MS of multiply deprotonated phosphopeptide anions provides sequence information via phosphorylation-intact a/x ions in addition to other sequence ions, satellite ions, and side-chain losses. Novel fragmentation processes include selective c-ion formation N-terminal to Ser/Thr and a phosphorylation-specific correlation between xn -98 ion abundances and phosphorylation at the n(th) residue. Sequencing-quality data required about 30 s of signal averaging. fsLID-MS/MS of singly deprotonated phosphopeptides did not yield product anions with stable trajectories, despite significant depletion of the precursor. CONCLUSIONS Multiply deprotonated phosphopeptide anions were sequenced via negative-mode fsLID-MS/MS, with phosphosite localization facilitated by a/x ion series in addition to diagnostic x(n)-98 ions. fsLID-MS/MS is qualitatively competitive with other techniques. Further efficiency enhancements (e.g., implementation on a linear trap or/and higher pulse frequencies) may permit sequence analyses on chromatographic timescales.


Analytical and Bioanalytical Chemistry | 2018

Metabolism of a sea lamprey pesticide by fish liver enzymes part B: method development and application in quantification of TFM metabolites formed in vivo

Ugo Bussy; Yu Wen Chung-Davidson; Tyler J. Buchinger; Ke Li; Scott A. Smith; A. Daniel Jones; Weiming Li

The sea lamprey (Petromyzon marinus) is a destructive invasive species in the Great Lakes. Since the 1960s, tons of the lampricide 3-trifluoromethyl-4-nitrophenol (TFM) has been applied to selected tributaries each year to eliminate or reduce sea lamprey larval populations. Therefore, the environmental impact of TFM needs to be evaluated. However, the metabolism of TFM and its mechanism of selective toxicity in sea lamprey is not yet fully understood. Based upon our previous report on the identification, synthesis, and characterization of TFM metabolites observed in liver incubates from sea lamprey and non-target fishes, we now provide a robust assay for quantifying TFM and its metabolites in fish liver tissue. This method is important for assessing bioaccumulation of TFM in the ecosystems. The compounds purified in our previous report were used to develop and validate a quantitative ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) assay for TFM and TFM metabolites formed in vivo. Several sample preparation techniques were compared, and a protein precipitation method was selected. The unavailability of stable isotopic internal standards was overcome by using a matrix matching method. After a thorough validation, this method was applied to determine the concentrations of TFM and its metabolites in fish liver tissues from animals exposed to TFM, and in the comparison between dead animals and survivors. Seven of eight expected metabolites were observed, some for the first time in vivo. Our results indicate that in vivo nitroreduction, glucuronidation, sulfation, and glutathione conjugation are involved in TFM metabolism in sea lamprey.


Analytical and Bioanalytical Chemistry | 2018

Metabolism of a sea lamprey pesticide by fish liver enzymes part A: identification and synthesis of TFM metabolites

Ugo Bussy; Yu Wen Chung-Davidson; Tyler J. Buchinger; Ke Li; Scott A. Smith; A. Daniel Jones; Weiming Li

The sea lamprey (Petromyzon marinus) is a destructive invasive species in the Great Lakes that contributed to the collapse of native fish populations in the mid-1900s. 3-Trifluoromethyl-4-nitrophenol (TFM) is a selective pesticide that has been applied to sea lamprey infested tributaries of the Great Lakes to kill larvae since the 1960s and has reduced the populations by as much as 90%. However, the metabolism of TFM by sea lamprey and non-target species is not fully illuminated. Elucidation of TFM metabolism is critical for understanding its mode of action and possible environmental impact. Here, we describe the screening, identification, synthesis and structural characterization of TFM metabolites in livers from sea lamprey and three non-target species that differ in their ability to survive TFM exposure. We identified glucuronidation, sulfation, N-acetylation, glutathione conjugation, and aromatic nitro group reduction as potential detoxification mechanisms. Seven metabolites were synthesized for use as markers of TFM metabolism in fish. Quantitative 1H NMR was used to assay synthesized metabolite stock solutions that were then used as standard material to develop a quantitative LC-MS/MS method for TFM metabolites.


Analyst | 2009

Circular arrays of polymer-based miniature rectilinear ion traps

Miriam Fico; Jeffrey D. Maas; Scott A. Smith; Anthony B. Costa; Zheng Ouyang; William J. Chappell; R. Graham Cooks

Collaboration


Dive into the Scott A. Smith's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

A. Daniel Jones

Michigan State University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Wei Xu

Beijing Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alan Higbee

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge