Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Scott R. Heron is active.

Publication


Featured researches published by Scott R. Heron.


Analytical Chemistry | 2010

Surface Acoustic Wave Nebulization of Peptides as a Microfluidic Interface for Mass Spectrometry

Scott R. Heron; Rab Wilson; Scott A. Shaffer; David R. Goodlett; Jonathan M. Cooper

We describe the fabrication of a surface acoustic wave (SAW) device on a LiNbO(3) piezoelectric transducer for the transfer of nonvolatile analytes to the gas phase at atmospheric pressure (a process referred to as nebulization or atomization). We subsequently show how such a device can be used in the field of mass spectrometry (MS) detection, demonstrating that SAW nebulization (SAWN) can be performed either in a discontinuous or pulsed mode, similar to that for matrix assisted laser desorption ionization (MALDI) or in a continuous mode like electrospray ionization (ESI). We present data showing the transfer of peptides to the gas phase, where ions are detected by MS. These peptide ions were subsequently fragmented by collision-induced dissociation, from which the sequence was assigned. Unlike MALDI mass spectra, which are typically contaminated with matrix ions at low m/z, the SAWN generated spectra had no such interference. In continuous mode, the SAWN plume was sampled on a microsecond time scale by a linear ion trap mass spectrometer and produced multiply charged peptide precursor ions with a charge state distribution shifted to higher m/z compared to an identical sample analyzed by ESI. The SAWN technology also provides the opportunity to re-examine a sample from a flat surface, repeatedly. The process can be performed without the need for capillaries, which can clog, reservoirs, which dilute the sample, and electrodes, which when in direct contact with sample, cause unwanted electrochemical oxidation. In both continuous and pulsed sampling modes, the quality of precursor ion scans and tandem mass spectra of peptides was consistent across the plumes lifetime.


Journal of the American Society for Mass Spectrometry | 2012

Surface Acoustic Wave Nebulization Produces Ions with Lower Internal Energy than Electrospray Ionization

Yue Huang; Sung Hwan Yoon; Scott R. Heron; Christophe Masselon; J. Scott Edgar; František Tureček; David R. Goodlett

Surface acoustic wave nebulization (SAWN) has recently been reported as a novel method to transfer non-volatile analytes directly from solution to the gas phase for mass spectrometric analysis. Here we present a comparison of the survival yield of SAWN versus electrospray ionization (ESI) produced ions. A series of substituted benzylpyridinium (BzPy) compounds were utilized to measure ion survival yield from which ion energetics were inferred. We also estimated bond dissociation energies using higher level quantum chemical calculations than previously reported for BzPy ions. Additionally, the effects on BzPy precursor ion survival of SAWN operational parameters such as inlet capillary temperature and solution flow-rate were investigated. Under all conditions tested, SAWN-generated BzPy ions displayed a higher tendency for survival and thus have lower internal energies than those formed by ESI.


Analytical Chemistry | 2012

Surface Acoustic Wave Nebulization Facilitating Lipid Mass Spectrometric Analysis

Sung Hwan Yoon; Yue Huang; J. Scott Edgar; Ying S. Ting; Scott R. Heron; Yuchieh Kao; Yanyan Li; Christophe Masselon; Robert K. Ernst; David R. Goodlett

Surface acoustic wave nebulization (SAWN) is a novel method to transfer nonvolatile analytes directly from the aqueous phase to the gas phase for mass spectrometric analysis. The lower ion energetics of SAWN and its planar nature make it appealing for analytically challenging lipid samples. This challenge is a result of their amphipathic nature, labile nature, and tendency to form aggregates, which readily precipitate clogging capillaries used for electrospray ionization (ESI). Here, we report the use of SAWN to characterize the complex glycolipid, lipid A, which serves as the membrane anchor component of lipopolysaccharide (LPS) and has a pronounced tendency to clog nano-ESI capillaries. We also show that unlike ESI SAWN is capable of ionizing labile phospholipids without fragmentation. Lastly, we compare the ease of use of SAWN to the more conventional infusion-based ESI methods and demonstrate the ability to generate higher order tandem mass spectral data of lipid A for automated structure assignment using our previously reported hierarchical tandem mass spectrometry (HiTMS) algorithm. The ease of generating SAWN-MS(n) data combined with HiTMS interpretation offers the potential for high throughput lipid A structure analysis.


Journal of Mass Spectrometry | 2016

Surface acoustic wave nebulization device with dual interdigitated transducers improves SAWN-MS performance

Yue Huang; Scott R. Heron; Alicia Clark; J. Scott Edgar; Sung Hwan Yoon; David P. A. Kilgour; František Tureček; Alberto Aliseda; David R. Goodlett

We compared mass spectrometric (MS) performance of surface acoustic wave nebulization (SAWN) generated by a single interdigitated transducer (IDT) designed to produce a progressive wave (PW) to one with a dual IDT that can in theory generate standing waves (SW). Given that devices using dual IDTs had been shown to produce fewer large size droplets on average, we hypothesized they would improve MS performance by improving the efficiency of desolvation. Indeed, the SW-SAWN chip provided an improved limit of detection of 1 femtomole of peptide placed on chip making it 100× more sensitive than the PW design. However, as measured by high-speed image recording and phase Doppler particle analyzer measurements, there was only a 26% increase in the small diameter (1-10 µm) droplets produced from the new device, precluding a conclusion that the decrease in droplet size was solely responsible for the improvement in MS signal/noise. Given that the dual IDT design produced a more instantaneous plume than the PW design, the more likely contributor to improved MS signal/noise was concluded to be a higher ion flux entering the mass spectrometer for the dual IDT designs. Notably, the dual IDT device allowed production of much higher quality protein mass spectra up to about 20 kDa, compared with the single IDT device. Copyright


Journal of Chromatography A | 2016

Screen-printed digital microfluidics combined with surface acoustic wave nebulization for hydrogen-deuterium exchange measurements.

Lucas Monkkonen; J. Scott Edgar; Daniel Winters; Scott R. Heron; C. Logan Mackay; Christophe Masselon; Adam A. Stokes; Patrick R. R. Langridge-Smith; David R. Goodlett

An inexpensive digital microfluidic (DMF) chip was fabricated by screen-printing electrodes on a sheet of polyimide. This device was manually integrated with surface acoustic wave nebulization (SAWN) MS to conduct hydrogen/deuterium exchange (HDX) of peptides. The HDX experiment was performed by DMF mixing of one aqueous droplet of angiotensin II with a second containing various concentrations of D2O. Subsequently, the degree of HDX was measured immediately by SAWN-MS. As expected for a small peptide, the isotopically resolved mass spectrum for angiotensin revealed that maximum deuterium exchange was achieved using 50% D2O. Additionally, using SAWN-MS alone, the global HDX kinetics of ubiquitin were found to be similar to published NMR data and back exchange rates for the uncooled apparatus using high inlet capillary temperatures was less than 6%.


Archive | 2014

Chapter 13:Surface Acoustic Wave Nebulization

Yue Huang; Scott R. Heron; Sung Hwan Yoon; David R. Goodlett

A surface acoustic wave (SAW) is an acoustic wave traveling along the surface of a material. In 2010 the first paper describing their use for producing ions for mass spectrometric detection was published, and the phrase “surface acoustic wave nebulization” (SAWN) coined to describe this phenomenon. Ions produced by SAWN are done so either in a continuous electrospray ionization (ESI) like mode or an intermittent manner like matrix-assisted laser desorption ionization (MALDI). In either mode nebulization occurs from a planar surface, with the opportunity to detect either positive or negative ions. Notably, SAWN mass spectra, of chemical compounds such as peptides and proteins that are chemically basic in nature, commonly exhibit a lower average charge-state distribution than ESI produces from the same solution. Importantly, given that no DC voltage is applied to the liquid sample to produce ions, the SAWN-nebulized ions can have lower internal energy than ESI- or MALDI-generated ions.


Archive | 2013

Methods and systems for mass spectrometry

David R. Goodlett; Scott R. Heron; Jonathan A. Cooper


Archive | 2010

Ions generated by surface acoustic wave device detected by mass spectrometry

David R. Goodlett; Scott R. Heron; Jon Cooper


Rapid Communications in Mass Spectrometry | 2016

Polydimethylsiloxane microchannel coupled to surface acoustic wave nebulization mass spectrometry

Gloria S. Yen; J. Scott Edgar; Sung Hwan Yoon; Yue Huang; Scott R. Heron; Daniel T. Chiu; David R. Goodlett


Archive | 2015

Surface acoustic wave nebulization

Yue Huang; Scott R. Heron; Sung Hwan Yoon; David R. Goodlett

Collaboration


Dive into the Scott R. Heron's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yue Huang

University of Washington

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J. Scott Edgar

University of Washington

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alicia Clark

University of Washington

View shared research outputs
Top Co-Authors

Avatar

Daniel T. Chiu

University of Washington

View shared research outputs
Top Co-Authors

Avatar

Gloria S. Yen

University of Washington

View shared research outputs
Top Co-Authors

Avatar

J. S. Edgar

University of Washington

View shared research outputs
Researchain Logo
Decentralizing Knowledge