Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Seoho Lee is active.

Publication


Featured researches published by Seoho Lee.


Analytica Chimica Acta | 2013

Label-free electrochemical monitoring of vasopressin in aptamer-based microfluidic biosensors

Peng He; Vlad Oncescu; Seoho Lee; Inhee Choi; David Erickson

Vasopressin is an indicating biomarker for blood pressure in the human body and low vasopressin levels can be indicative of late-phase hemorrhagic shock or other traumatic injuries. In this paper we have developed an aptamer-based label-free microfluidic biosensor for the electrochemical detection of vasopressin. The detection area consists of aptamers immobilized on carbon nanotubes which specifically capture the vasopressin molecules in solution resulting in changes in conductivity across the sensor. We report a limit of detection of 43 pM in standard solutions and demonstrate high detection specificity toward vasopressin when different interferents are present. The miniaturized microfluidic biosensor offers continuous monitoring of different vasopressin levels with good potential for portability. Ultimately such a system could serve as a point-of-care diagnostics tool for patients with excessive bleeding when standard medical infrastructure is not available.


Scientific Reports | 2016

NutriPhone: a mobile platform for low-cost point-of-care quantification of vitamin B12 concentrations.

Seoho Lee; Dakota O’Dell; Jess Hohenstein; Susannah Colt; Saurabh Mehta; David Erickson

Vitamin B12 is necessary for formation of red blood cells, DNA synthesis, neural myelination, brain development, and growth. Vitamin B12 deficiency is often asymptomatic early in its course; however, once it manifests, particularly with neurological symptoms, reversal by dietary changes or supplementation becomes less effective. Access to easy, low cost, and personalized nutritional diagnostics could enable individuals to better understand their own deficiencies as well as track the effects of dietary changes. In this work, we present the NutriPhone, a mobile platform for the analysis of blood vitamin B12 levels in 15 minutes. The NutriPhone technology comprises of a smartphone accessory, an app, and a competitive-type lateral flow test strip that quantifies vitamin B12 levels. To achieve the detection of sub-nmol/L physiological levels of vitamin B12, our assay incorporates an innovative “spacer pad” for increasing the duration of the key competitive binding reaction and uses silver amplification of the initial signal. We demonstrate the efficacy of our NutriPhone system by quantifying physiologically relevant levels of vitamin B12 and performing human trials where it was used to accurately evaluate blood vitamin B12 status of 12 participants from just a drop (~40 μl) of finger prick blood.


Analytical Chemistry | 2016

Two-Color Lateral Flow Assay for Multiplex Detection of Causative Agents Behind Acute Febrile Illnesses

Seoho Lee; Saurabh Mehta; David Erickson

Acute undifferentiated febrile illnesses (AFIs) represent a significant health burden worldwide. AFIs can be caused by infection with a number of different pathogens including dengue (DENV) and Chikungunya viruses (CHIKV), and their differential diagnosis is critical to the proper patient management. While rapid diagnostic tests (RDTs) for the detection of IgG/IgM against a single pathogen have played a significant role in enabling the rapid diagnosis in the point-of-care settings, the state-of-the-art assay scheme is incompatible with the multiplex detection of IgG/IgM to more than one pathogen. In this paper, we present a novel assay scheme that uses two-color latex labels for rapid multiplex detection of IgG/IgM. Adapting this assay scheme, we show that 4-plex detection of the IgG/IgM antibodies to DENV and CHIKV is possible in 10 min by using it to correctly identify 12 different diagnostic scenarios. We also show that blue, mixed, and red colorimetric signals corresponding to IgG, IgG/IgM, and IgM positive cases, respectively, can be associated with distinct ranges of hue intensities, which could be exploited by analyzer systems in the future for making accurate, automated diagnosis. This represents the first steps toward the development of a single RDT-based system for the differential diagnosis of numerous AFIs of interest.


Biosensors and Bioelectronics | 2018

ironPhone: Mobile device-coupled point-of-care diagnostics for assessment of iron status by quantification of serum ferritin

Balaji Srinivasan; Dakota O’Dell; Julia L. Finkelstein; Seoho Lee; David Erickson; Saurabh Mehta

Iron deficiency (ID) is an urgent public health problem that has devastating effects on maternal and child health. However, due to poor access and affordability, screening and diagnosis for ID is often limited to proxy hemoglobin measurements alone. Here, we report the development and validation of ironPhone, a mobile-device coupled portable diagnostics for quantification of serum ferritin concentrations, an iron status biomarker, within a few minutes, from a drop of fingerprick blood. The ironPhone diagnostic platform comprises of a smartphone accessory, an app, and a disposable lateral flow immunoassay test strip to quantify serum ferritin. For initial validation in the lab, we optimized and evaluated the performance of ironPhone with known ferritin concentrations in spiked buffer and serum samples. Following lab validation, we performed a human validation by collecting fingerprick whole blood samples from 20 participants to assess iron status using ironPhone and compared the results with the laboratory standard IMMULITE 2000 analyzer. Findings from the ironPhone for the buffer and spiked serum samples provided a calibration curve with R2 values of 0.97 (n=27) and 0.93 (n=12), respectively. On comparison with the laboratory standard IMMULITE analyzer in whole blood samples, a correlation of 0.92 (P<0.0001) was observed with a sensitivity of over 90% for predicting ID (ferritin<15.0µg/L) via the ironPhone, demonstrating its promise for iron status assessment at the point-of-care.


Current Opinion in Biotechnology | 2017

Precision nutrition — review of methods for point-of-care assessment of nutritional status

Balaji Srinivasan; Seoho Lee; David Erickson; Saurabh Mehta

Precision nutrition encompasses prevention and treatment strategies for optimizing health that consider individual variability in diet, lifestyle, environment and genes by accurately determining an individuals nutritional status. This is particularly important as malnutrition now affects a third of the global population, with most of those affected or their care providers having limited means of determining their nutritional status. Similarly, program implementers often have no way of determining the impact or success of their interventions, thus hindering their scale-up. Exciting new developments in the area of point-of-care diagnostics promise to provide improved access to nutritional status assessment, as a first step towards enabling precision nutrition and tailored interventions at both the individual and community levels. In this review, we focus on the current advances in developing portable diagnostics for assessment of nutritional status at point-of-care, along with the numerous design challenges in this process and potential solutions.


PLOS ONE | 2015

Lab-on-a-bird: biophysical monitoring of flying birds.

Abdurrahman Gumus; Seoho Lee; Syed Saad Ahsan; Kolbeinn Karlsson; Richard M. Gabrielson; Christopher G. Guglielmo; David W. Winkler; David Erickson

The metabolism of birds is finely tuned to their activities and environments, and thus research on avian systems can play an important role in understanding organismal responses to environmental changes. At present, however, the physiological monitoring of bird metabolism is limited by the inability to take real-time measurements of key metabolites during flight. In this study, we present an implantable biosensor system that can be used for continuous monitoring of uric acid levels of birds during various activities including flight. The system consists of a needle-type enzymatic biosensor for the amperometric detection of uric acid in interstitial fluids. A lightweight two-electrode potentiostat system drives the biosensor, reads the corresponding output current and wirelessly transfers the data or records to flash memory. We show how the device can be used to monitor, in real time, the effects of short-term flight and rest cycles on the uric acid levels of pigeons. In addition, we demonstrate that our device has the ability to measure uric acid level increase in homing pigeons while they fly freely. Successful application of the sensor in migratory birds could open up a new way of studying birds in flight which would lead to a better understanding of the ecology and biology of avian movements.


Food and Nutrition Bulletin | 2017

Rainer Gross Award Lecture 2016

Saurabh Mehta; Susannah Colt; Seoho Lee; David Erickson

The need for improving methods of nutritional assessment and delivering primary health care globally cannot be overemphasized. While advances in medical technology typically create more disparities because of access being limited to resource-rich settings, a transition of health care to a mobile platform is increasingly leveling the field. Technological advances offer opportunities to scale laboratory procedures down to mobile devices, such as smartphones and tablets. Globalization also provides the required infrastructure and network capacity to support the use of mobile health devices in developing settings where nutritional deficiencies are most prevalent. Here, we discuss some of the applications and advantages provided by expanding markets of biomarker measurement coupled with primary health care and public health systems and how this is enhancing access and delivery of health services with significant global impact.


Proceedings of SPIE | 2016

NutriPhone: vitamin B12 testing on your smartphone(Conference Presentation)

Seoho Lee; Dakota O'Dell; Jessica Hohenstein; Susannah Colt; Saurabh Mehta; David Erickson

Vitamin B12 deficiency is the leading cause of cognitive decline in the elderly and is associated with increased risks of several acute and chronic conditions including anemia. The deficiency is prevalent among the world population, most of whom are unaware of their condition due to the lack of a simple diagnostics system. Recent advancements in the smartphone-enabled mobile health can help address this problem by making the deficiency tests more accessible. Previously, our group has demonstrated the NutriPhone, a smartphone platform for the accurate quantification of vitamin D levels. The NutriPhone technology comprises of a disposable test strip that performs a colorimetric reaction upon collecting a sample, a reusable accessory that interfaces with the smartphone camera, and a smartphone app that stores the algorithm for analyzing the test-strip reaction. In this work, we show that the NutriPhone can be expanded to measure vitamin B12 concentrations by developing a lateral flow assay for B12 that is compatible with our NutriPhone system. Our novel vitamin B12 assay incorporates blood sample processing and key reagent storage on-chip, which advances it into a sample-in-answer-out format that is suitable for point-of-care diagnostic applications. In order to enable the detection of pM levels of vitamin B12 levels, silver amplification of the initial signal is used within the total assay time of less than 15 minutes. We demonstrate the effectiveness of our NutriPhone system by deploying it in a resource-limited clinical setting in India where it is used to test tens of participants for vitamin B12 deficiency.


Proceedings of SPIE | 2016

StressPhone: smartphone based platform for measurement of cortisol for stress detection(Conference Presentation)

Aadhar Jain; Elizabeth Rey; Seoho Lee; Dakota O'Dell; David Erickson

Anxiety disorders are estimated to be the most common mental illness in US affecting around 40 million people and related job stress is estimated to cost US industry up to


PLOS ONE | 2014

Autonomous device for application in late-phase hemorrhagic shock prevention.

Vlad Oncescu; Seoho Lee; Abdurrahman Gumus; Kolbeinn Karlsson; David Erickson

300 billion due to lower productivity and absenteeism. A personal diagnostic device which could help identify stressed individuals would therefore be a huge boost for workforce productivity. We are therefore developing a point of care diagnostic device that can be integrated with smartphones or tablets for the measurement of cortisol - a stress related salivary biomarker, which is known to be strongly involved in bodys fight-or-flight response to a stressor (physical or mental). The device is based around a competitive lateral flow assay whose results can then be read and quantified through an accessory compatible with the smartphone. In this presentation, we report the development and results of such an assay and the integrated device. We then present the results of a study relating the diurnal patterns of cortisol levels and the alertness of an individual based on the circadian rhythm and sleep patterns of the individual. We hope to use the insight provided by combining the information provided by levels of stress related to chemical biomarkers of the individual with the physical biomarkers to lead to a better informed and optimized activity schedule for maximized work output.

Collaboration


Dive into the Seoho Lee's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge