Sergio Cadoni
CTO Hospital
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Sergio Cadoni.
Endoscopy | 2013
Sergio Cadoni; Paolo Gallittu; Stefano Sanna; Viviana Fanari; Maria L. Porcedda; Matteo Erriu; Felix W. Leung
BACKGROUND AND STUDY AIM Water-aided colonoscopy includes water immersion and water exchange. Several small single-center studies have suggested that the use of water rather than air insufflation during colonoscopy reduces pain on insertion. The aim of this study was to investigate whether water-aided colonoscopy is less painful than air insufflation in a large cohort of patients. PATIENTS AND METHODS This was a two-center, randomized controlled trial. Consecutive patients who agreed to start colonoscopy without premedication were included. Sedation was administered on demand. Water-aided colonoscopy was performed using water immersion in the early phase of the study, and subsequently water exchange was used. The primary endpoint was cecal intubation with pain scores of ≤ 2 and sedation with no or ≤ 2 mg midazolam. Secondary outcomes were pain score at discharge, cecal intubation rate and time, and adenoma detection rate (ADR). RESULTS A total of 672 patients were randomized to water exchange (n = 338) or air insufflation (n = 334). The primary endpoint was achieved in more patients in the water exchange group (83.8 % vs. 62 %; P < 0.0005). On-demand sedation was also required less (11.5 % vs. 26.0 %; P < 0.0005) and mean pain score was lower (1.3 vs. 2.3; P < 0.0005) in the water exchange group. The cecal intubation rates were comparable. Water exchange had a significantly higher overall ADR (25.8 % vs. 19.1 %; P = 0.041), proximal ADR (10.1 % vs. 4.8 %; P = 0.014), and proximal < 10 mm ADR (7.7 % vs. 3.9 %; P = 0.046); proximal ADR was also higher in screening-only patients in the water exchange group (18.9 % vs. 7.4 %; P = 0.015). No detailed analysis was possible for the air insufflation vs. water immersion comparison. CONCLUSION The current results confirmed that water exchange minimized the requirement for sedation and increased the ADR.
Endoscopy | 2017
Sergio Cadoni; Přemysl Falt; Emanuele Rondonotti; Franco Radaelli; Petr Fojtík; Paolo Gallittu; Mauro Liggi; Arnaldo Amato; Silvia Paggi; Vit Smajstrla; Ondřej Urban; Matteo Erriu; Malcolm Koo; Felix W. Leung
Background and study aims Single-center studies, which were retrospective and/or involved unblinded colonoscopists, have suggested that water exchange, but not water immersion, compared with air insufflation significantly increases the adenoma detection rate (ADR), particularly in the proximal and right colon. Head-to-head comparison of the three techniques with ADR as primary outcome and blinded colonoscopists has not been reported to date. In a randomized controlled trial with blinded colonoscopists, we aimed to evaluate the impact of the three insertion techniques on ADR. Patients and methods A total of 1224 patients aged 50 - 70 years (672 males) and undergoing screening colonoscopy were randomized 1:1:1 to water exchange, water immersion, or air insufflation. Split-dose bowel preparation was adopted to optimize colon cleansing. After the cecum had been reached, a second colonoscopist who was blinded to the insertion technique performed the withdrawal. The primary outcome was overall ADR according to the three insertion techniques (water exchange, water immersion, and air insufflation). Secondary outcomes were other pertinent overall and right colon procedure-related measures. Results Baseline characteristics of the three groups were comparable. Compared with air insufflation, water exchange achieved a significantly higher overall ADR (49.3 %, 95 % confidence interval [CI] 44.3 % - 54.2 % vs. 40.4 % 95 %CI 35.6 % - 45.3 %; P = 0.03); water exchange showed comparable overall ADR vs. water immersion (43.4 %, 95 %CI 38.5 % - 48.3 %; P = 0.28). In the right colon, water exchange achieved a higher ADR than air insufflation (24.0 %, 95 %CI 20.0 % - 28.5 % vs. 16.9 %, 95 %CI 13.4 % - 20.9 %; P = 0.04) and a higher advanced ADR (6.1 %, 95 %CI 4.0 % - 9.0 % vs. 2.5 %, 95 %CI 1.2 % - 4.6 %; P = 0.03). Compared with air insufflation, the mean number of adenomas per procedure was significantly higher with water exchange (P = 0.04). Water exchange achieved the highest cleanliness scores (overall and in the right colon). These variables were comparable between water immersion and air insufflation. Conclusions The design with blinded observers strengthens the validity of the observation that water exchange, but not water immersion, can achieve significantly higher adenoma detection than air insufflation. Based on this evidence, the use of water exchange should be encouraged.Trial registered at ClinicalTrials.gov (NCT02041507).
Digestive and Liver Disease | 2016
Sergio Cadoni; Přemysl Falt; Stefano Sanna; Mariangela Argiolas; Viviana Fanari; Paolo Gallittu; Mauro Liggi; Donatella Mura; Maria L. Porcedda; Vit Smajstrla; Matteo Erriu; Felix W. Leung
BACKGROUND Single site studies in male Veterans in the U.S. reported increased detection of presumptive cancer precursors (adenomas, hyperplastic polyps) in the proximal colon (cecum-splenic flexure) by water exchange. AIMS Assess the reproducibility of the observation. METHODS Analysis of secondary outcomes collected prospectively in 3 similarly designed randomized controlled trials using water exchange, water immersion and insufflation (air or carbon dioxide). MAIN OUTCOME detection rates of adenomas and hyperplastic polyps in proximal, transverse and right colon (cecum-ascending). RESULTS 704 males (173 screening) were evaluated. In the proximal colon, WE showed increased detection of small adenomas (p=0.009) and adenomas plus hyperplastic polyps (p=0.015) (vs insufflation); increased detection of adenomas plus hyperplastic polyps of any size (p=0.045) and of small size (p=0.04) (vs water immersion). In the right colon water exchange increased detection of small adenomas (19% vs 12.1%, p=0.04) (vs insufflation); small adenomas (19% vs 12%, p=0.038), adenomas plus hyperplastic polyps of any size (25% vs 16.7%, p=0.028) and of small size (23.7% vs 14.6%, p=0.012) (vs water immersion). Water exchange significantly improved bowel cleanliness. Sedation had no impact on lesion detection. CONCLUSIONS Water exchange is a superior insertion technique for detection of adenomas and hyperplastic polyps primarily in the right colon, especially those of small size.
World Journal of Gastrointestinal Endoscopy | 2016
Sergio Cadoni; Mauro Liggi; Premysl Falt; Stefano Sanna; Mariangela Argiolas; Viviana Fanari; Paolo Gallittu; Donatella Mura; Maria L. Porcedda; Vit Smajstrla; Matteo Erriu; Felix W. Leung
AIM To determine whether observations were reproducible among investigators. METHODS From March 2013 through June 2014, 18-85-year-old diagnostic and 50-70-year-old screening patients were enrolled at each center to on-demand sedation colonoscopy with water exchange (WE), water immersion (WI) and insufflation with air or CO2 for insertion and withdrawal [air or carbon dioxide (AICD)]. Data were aggregated for analysis. PRIMARY OUTCOME Variations in real-time maximum insertion pain (0 = none, 1-2 = discomfort, 10 = worst). RESULTS One thousand and ninety-one cases analyzed: WE (n = 371); WI (n = 338); AICD (n = 382). Demographics and indications were comparable. The WE group had the lowest real-time maximum insertion pain score, mean (95%CI): WE 2.8 (2.6-3.0), WI 3.8 (3.5-4.1) and AICD 4.4 (4.1-4.7), P < 0.0005. Ninety percent of the colonoscopists were able to use water exchange to significantly decrease maximum insertion pain scores. One investigator had high insertion pain in all groups, nonetheless WE achieved the lowest real-time maximum insertion pain score. WE had the highest proportions of patients with painless unsedated colonoscopy (vs WI, P = 0.013; vs AICD, P < 0.0005); unsedated colonoscopy with only minor discomfort (vs AICD, P < 0.0005), and completion without sedation (vs AICD, P < 0.0005). CONCLUSION Aggregate data confirm superiority of WE in lowering colonoscopy real-time maximum insertion pain and need for sedation. Ninety percent of investigators were able to use water exchange to significantly decrease maximum insertion pain scores. Our results suggest that the technique deserves consideration in a broader scale.
VideoGIE | 2018
Sergio Cadoni; Sauid Ishaq
3,4 Water-aided colonoscopy (WAC) encompasses different techniques entailing infusion of water as an adjunct to, or in lieu of, gas insufflation to distend the lumen during insertion (Figs. 1A-C). The colon is not elongated; bends and flexures are smoother and easier to negotiate. Infusion of warm-to-touch water is preferred because it decreases spasms of the musculature of the bowel. However, warm water and room-temperature water are equally effective in decreasing the pain felt by patients during
United European gastroenterology journal | 2018
Sergio Cadoni; Mauro Liggi; Paolo Gallittu; Donatella Mura; Lorenzo Fuccio; Malcolm Koo; Sauid Ishaq
Background Endoscopic mucosal resection is well-established for resecting flat or sessile benign colon polyps. The novel underwater endoscopic mucosal resection eschews submucosal injection prior to endoscopic mucosal resection. Reports about underwater endoscopic mucosal resection were limited to small series of single and/or tertiary-care referral centers, with single or supervised operators. Objective The purpose of this study was to determine feasibility and efficacy of underwater resection of polyps of any morphology (underwater polypectomy, here includes underwater endoscopic mucosal resection) in routine clinical practice. Methods This study involved a comparison of colonoscopy records of two community hospitals (January 2015–December 2016) for underwater polypectomy (n = 195) and gas insufflation polypectomy (n = 186). Results Comparable demographics, procedural data, overall distribution, morphology and size of resected lesions, number of en bloc and R0 resections (any polyp morphology and size); exception: overall, underwater polypectomy pedunculated polyps were significantly larger than those in the gas insufflation polypectomy group, p = 0.030. Underwater polypectomy (median, min) resection time was significantly shorter than gas insufflation polypectomy: sessile and flat polyps 6–9 mm, 0.8 vs 2.7 (p = 0.040); 10–19 mm, 2.0 vs 3.3 (p = 0.025), respectively; pedunculated polyps 6–19 mm, 0.8 vs 3.3 (p < 0.001). Underwater polypectomy resection of pedunculated polyps 6–19 mm showed significantly less immediate bleeding: 11.1% vs 1.5%, respectively (p = 0.031). Conclusions Underwater polypectomy can be efficaciously used in routine clinical practice for the complete resection of colon polyps, with several advantages over gas insufflation polypectomy.
Gastrointestinal Endoscopy | 2018
L. Fuccio; Leonardo Frazzoni; Cesare Hassan; Marina La Marca; Valentina Paci; Veronica Smania; Nicola de Bortoli; Franco Bazzoli; Alessandro Repici; Douglas K. Rex; Sergio Cadoni
BACKGROUND AND AIMS Water-aided colonoscopy techniques, such as water immersion (WI) and water exchange (WE), have shown different results regarding adenoma detection rate (ADR). We determined the impact of WI and WE on ADR and other procedural outcomes versus gas (air, AI; CO2) insufflation colonoscopy. METHODS A systematic search of multiple databases for randomized controlled trials comparing WI and/or WE with AI and/or CO2 and reporting ADR was conducted. A network meta-analysis with mixed comparisons was performed. Primary outcome was ADR (overall, in the right side of the colon and by colonoscopy indication). RESULTS Seventeen randomized controlled trials (10,350 patients) were included. WE showed a significantly higher overall ADR versus WI (odds ratio [OR], 1.31; 95% credible interval [CrI], 1.12-1.55) versus AI (OR, 1.40; CrI, 1.22-1.62) versus CO2 (OR, 1.48; 95% CrI, 1.15-1.86). WE achieved the highest ADR also in the right side of the colon and in colorectal cancer screening cases (both significant vs AI and WI) as well as in patients taking a split-dose preparation (significant vs all the other techniques). The Boston Bowel Preparation Scale cleanliness score (vs AI and WI) was significantly higher for WE. Both WI and WE showed increased proportion of unsedated examinations and decreased real-time insertion pain, with WE being the least-painful insertion technique. Withdrawal time was comparable across techniques, but WE showed the longest insertion time (3-5 additional minutes). CONCLUSIONS WE significantly increases overall ADR, ADR in screening cases, and in the right side of the colon; it also improves colon cleanliness but requires a longer insertion time.
Gastrointestinal Endoscopy | 2018
Sergio Cadoni; Cesare Hassan; Leonardo Frazzoni; Sauid Ishaq; Felix W. Leung
BACKGROUND AND AIMS Separate randomized controlled trials (RCTs) showed water exchange (WE) colonoscopy outperformed other techniques in minimizing insertion pain and optimizing adenoma detection rate. Longer insertion time required for removal of infused water, residual air, and feces might have hampered its wider adoption. We evaluate the impact of WE compared with air or carbon dioxide insufflation (GAS) on room turnaround efficiency measured by cecal intubation, withdrawal, and total procedure times. METHODS With a systematic search in PubMed, Embase, and Cochrane Library, we identified RCTs (published before March 18, 2018) that compared WE with GAS. We focused on parameters of turnaround efficiency and patient-centered outcomes. RESULTS We analyzed 8371 subjects from 17 studies. Demographics and indications were comparable. Mean cecal intubation time (± standard deviation) was WE 12.5 ± 6.1 minutes versus GAS 11.1 ± 7.0 minutes, with a mean difference of 1.4 ± 3.4 minutes. Six studies showed significant differences in insertion time, with mean cecal intubation times of 11.6 ± 5.1 minutes for WE versus 7.7 ± 5.2 minutes for GAS, with a mean difference of 3.9 ± 1.1 minutes. Mean withdrawal time was similar. Mean total procedure time was WE 26.0 ± 9.7 versus GAS 24.2 ± 9.6, with a mean difference of 1.8 ± 6.2 minutes. All mean procedure times were significantly different. Patient-centered outcomes revealed that patients examined with WE had significantly lower real-time insertion pain score, less need for sedation, and higher willingness to repeat the procedure. CONCLUSIONS Based on parameters of procedural time, the impact of WE colonoscopy on endoscopy room turnaround yields an increase in total procedure time of about 2 minutes and is associated with significant improvement in specific patient-centered outcomes.
Journal of Gastroenterology, Pancreatology & Liver Disorders | 2017
Flaminia Cavallaro; Gian Eugenio Tontini; Rosamaria Bozzi; Nicoletta Nandi; Domenico Cattaneo; Federica Villa; Sergio Cadoni; Paolo Gallittu; Emanuele Rondonotti; Maurizio Vecchi
Small bowel evaluation has been considered for a long time technically challenging because of its length, location and tortuosity. But in 2001, with the FDA approval of capsule endoscopy started a revolution in the study of small bowel that, in the last years, has progressively and rapidly expanded [1-5]. Nevertheless, one of the main limitations to the spread of capsule endoscopy is the high cost and therefore a questionable cost-effectiveness when used in clinical practice. Lately the picture could change to the introduction in the European of a new video capsule system (OMOM CE) produced by Jinshan Science & Technology Company (Chongqing, China) [6, 7]; this device has and obtained the CE mark for marketing in Europe. Indeed, this device costs approximately half the other capsule systems. However, to date only few studies have been performed on the use in clinical practice of this new video capsule system, and none of them was carried out in the western world.
GE Portuguese Journal of Gastroenterology | 2017
Keith Siau; Sergio Cadoni
Consequently, colonoscopy is performed under conscious or deep sedation in many countries, regardless of procedure risk, with considerable increases in institutional and social health expenditures, e.g., nursing staff and space for recovery, patient burdens of escort requirement, onsite recovery time after sedation and lost time until returning to routine activities, and increased risks of sedation complications [3]. It would be more rational to improve colonoscopy techniques to avoid generating pain than be compelled to suppress it. As pain is often a result of luminal distention and loop formation, the avoidance of either factor may improve patient comfort. Infusion of water to distend the lumen during the insertion phase eliminates many undesired consequences of gas insufflation, particularly when water is infused in an airless lumen. The colon is not elongated and the sigmoid is straightened, allowing an easier passage into the descending colon; bends and flexures are smoother and easier to negotiate, making the procedure easier and less painful. Moreover, the weight effect of water appears to prevent loop formation at the sigmoid colon [2]. As such, this technique has been used successfully in cases of previously failed cecal intubation. Into this background comes the article by Azevedo et al. [4]. The study correctly distinguishes between two dif