Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Shane J. Foley is active.

Publication


Featured researches published by Shane J. Foley.


British Journal of Radiology | 2012

Establishment of CT diagnostic reference levels in Ireland

Shane J. Foley; Mark F. McEntee; Louise Rainford

OBJECTIVE To propose Irish CT diagnostic reference levels (DRLs) by collecting radiation doses for the most commonly performed CT examinations. METHODS A pilot study investigated the most frequent CT examinations. 40 CT sites were then asked to complete a survey booklet to allow the recording of CT parameters for each of 9 CT examinations during a 12-week period. Dose data [CT volume index (CTDI(vol)) and dose-length product (DLP)] on a minimum of 10 average-sized patients in each category were recorded to calculate a mean site CTDI(vol) and DLP value. The rounded 75th percentile was used to calculate a DRL for each site and the country by compiling all results. RESULTS are compared with international DRL data. Results Data were collected for 3305 patients. 30 sites responded with data for 34 scanners, representing 54% of the national total. All equipment had multislice capability (2-128 slices). DRLs are proposed using CTDI(vol) (mGy) and DLP (mGy cm) for CT head (66/58 and 940, respectively), sinuses (16 and 210, respectively), cervical spine (19 and 420, respectively), thorax (9/11 and 390, respectively), high resolution CT (7 and 280, respectively), CT pulmonary angiography (13 and 430, respectively), multiphase abdomen (13 and 1120, respectively), routine abdomen/pelvis (12 and 600, respectively) and trunk examinations (10/12 and 850, respectively). These values are lower than current DRLs and comparable to other international studies. Wide variations in mean doses are noted across sites. CONCLUSIONS Baseline figures for Irish CT DRLs are provided on the most frequently performed CT examinations. The variations in dose between CT departments as well as between identical scanners suggest a large potential for optimisation of examinations.


British Journal of Radiology | 2015

A review of cross-sectional imaging, ultrasound and nuclear medicine utilization patterns in paediatric patients in Ireland, 2003–12

Michelle O'Connor; John Ryan; Shane J. Foley

OBJECTIVE Recent trends in paediatric imaging have been examined in Australia and the USA. Such literature in Europe is sparse, incomprehensive and outdated. This research investigated (1) population-based trends in the use of advanced medical imaging in children in Ireland from 2003 to 2012; (2) its use across age and gender; and (3) the most commonly performed examinations within each modality. METHODS A retrospective cohort analysis study was carried out within Irish paediatric hospitals. All CT, MRI, ultrasound and nuclear medicine (NM) annual examination data from 2003 to 2012 was obtained from radiology information systems. RESULTS 224,173 imaging procedures were carried out on 84,511 patients, 68% of which were ultrasound, 15% were MRI, 11% were CT and 6% were NM. Between 2003 and 2012, MRI (+280%) and CT (+80%) saw the largest increases in use, followed by ultrasound (+67%) and NM (+10%). Almost half of the study population were less than 3 years old. CT imaging was more frequent than MR in 2005. By 2012, MR rates were twice that of CT. CT imaging rates were the lowest in the youngest age categories. CONCLUSION Advanced imaging use, particularly MRI, has risen substantially over the past 10 years. The utilization of non-ionizing modalities increased between 2003 and 2012, especially in brain, spinal and abdominal imaging. MR is now used at twice the frequency of CT. ADVANCES IN KNOWLEDGE Longitudinal advanced imaging utilization trends, including CT trends, have been established in the Irish paediatric population.


American Journal of Roentgenology | 2011

Breast Surface Radiation Dose During Coronary CT Angiography: Reduction by Breast Displacement and Lead Shielding

Shane J. Foley; Mark F. McEntee; Stephan Achenbach; Patrick C. Brennan; Louise S. Rainford; Jonathan D. Dodd

OBJECTIVE The purpose of this study was to prospectively evaluate the effect of cranial breast displacement and lead shielding on in vivo breast surface radiation dose in women undergoing coronary CT angiography. SUBJECTS AND METHODS Fifty-four women (mean age, 59.2 ± 9.8 years) prospectively underwent coronary 64-MDCT angiography for evaluation of chest pain. The patients were randomly assigned to a control group (n = 16), breast displacement group (n = 22), or breast displacement plus lead shielding group (n = 16). Thermoluminescent dosimeters (TLDs) were placed superficially on each breast quadrant and the areolar region of both breasts. Breast surface radiation doses, the degree of breast displacement, and coronary image quality were compared between groups. A phantom dose study was conducted to compare breast doses with z-axis positioning on the chest wall. RESULTS A total of 1620 TLD dose measurements were recorded. Compared with control values, the mean breast surface dose was reduced 23% in the breast displacement group (24.3 vs 18.6 mGy, p = 0.015) and 36% in the displacement plus lead shielding group (24.3 vs 15.6 mGy, p = 0.0001). Surface dose reductions were greatest in the upper outer (displacement alone, 66%; displacement plus shielding, 63%), upper inner (65%, 58%), and areolar quadrants (44%, 53%). The smallest surface dose reductions were recorded for A-cup breasts: 7% for the displacement group and 3% for the displacement plus lead group (p = 0.741). Larger reductions in surface dose were recorded for B-cup (25% and 56%, p = 0.273), C-cup (38% and 60%, p = 0.001), and D-cup (31% and 25%, p = 0.095) sizes. Most of the patients (79%) had either good (< 50% of breast above scan range) or excellent (< 75% of breast above the scan range) breast displacement. No significant difference in coronary image quality was detected between groups. The phantom dose study showed that surface TLD measurements were underestimates of absorbed tissue dose by a mean of 9% and that a strong negative correlation exists between the amount of cranial displacement and breast dose. CONCLUSION Use of breast displacement during coronary CTA substantially reduces the radiation dose to the breast surface.


Radiation Protection Dosimetry | 2014

THE ESTABLISHMENT OF COMPUTED TOMOGRAPHY DIAGNOSTIC REFERENCE LEVELS IN PORTUGAL

Joana Santos; Shane J. Foley; Graciano Paulo; Mark F. McEntee; Louise Rainford

The aims of this study were to investigate the frequency of Portuguese computed tomography (CT) examinations, identify protocol application and establish diagnostic reference levels (DRLs). CT departments (n=211) were surveyed nationally (June 2011-January 2012) and CT protocol information and dose data were collected, as were retrospective age-categorised paediatric CT data from three national paediatric centres. The proposed national CT DRLs (CTDIvol) for adults were 75, 18, 14, 18, 17, 36, 22, 27 and 16 mGy for head, neck, chest, abdomen, pelvis, cervical, dorsal, lumbar and joints, respectively. The levels for paediatric head and chest examinations were as follows: 48 and 2 mGy (newborns), 50 and 6 mGy (5 y olds), 70 and 6 mGy (10 y olds) and 72 and 7 mGy (15 y olds). A limited number of current paediatric protocols aligned to recommended international age categorisations. Portuguese DRLs were generally higher than European recommendations, suggesting potential for optimisation. The need for greater standardisation of age-categorised paediatric protocols was identified.


Radiation Protection Dosimetry | 2013

An evaluation of in-plane shields during thoracic CT

Shane J. Foley; Mark F. McEntee; Louise Rainford

The object of this study was to compare organ dose and image quality effects of using bismuth and barium vinyl in-plane shields with standard and low tube current thoracic CT protocols. A RANDO phantom was scanned using a 64-slice CT scanner and three different thoracic protocols. Thermoluminescent dosemeters were positioned in six locations to record surface and absorbed breast and lung doses. Image quality was assessed quantitatively using region of interest measurements. Scanning was repeated using bismuth and barium vinyl in-plane shields to cover the breasts and the results were compared with standard and reduced dose protocols. Dose reductions were most evident in the breast, skin and anterior lung when shielding was used, with mean reductions of 34, 33 and 10 % for bismuth and 23, 18 and 11 % for barium, respectively. Bismuth was associated with significant increases in both noise and CT attenuation values for all the three protocols, especially anteriorly and centrally. Barium shielding had a reduced impact on image quality. Reducing the overall tube current reduced doses in all the locations by 20-27 % with similar increases in noise as shielding, without impacting on attenuation values. Reducing the overall tube current best optimises dose with minimal image quality impact. In-plane shields increase noise and attenuation values, while reducing anterior organ doses primarily. Shielding remains a useful optimisation tool in CT and barium is an effective alternative to bismuth especially when image quality is of concern.


Radiation Protection Dosimetry | 2015

Establishment of diagnostic reference levels for CT trunk examinations in the Western region of Saudi Arabia

Abdulaziz A. Qurashi; Louise Rainford; Shane J. Foley

Diagnostic reference levels (DRLs) are an important optimisation tool, which aid in identifying abnormally high dose levels. These are currently not available in Saudi Arabia, and this research aims to remedy this. CT dose data (DLP and CTDIvol) were collected for a minimum number of 10 adult patients of average size (60-80 kg) presenting for a range of CT examinations from public hospitals in the western region of Saudi Arabia. These include routine chest, high-resolution chest (HRCT), pulmonary angiography (CTPA), abdomen and pelvis (AP) and the combined chest, abdomen and pelvis (CAP) CT examinations. Mean values for each site were calculated, and the 75th percentile of DLP and CTDIvol was used as a basis for DRLs. Data for 550 patients were collected from 14 hospitals over a 7-month period. The rounded third-quartile CTDIvol and DLP were 18 mGy and 630 mGy cm(-1) for chest CT, 20 mGy and 600mGy cm(-1) for HRCT, 18 mGy and 480 mGy cm(-1) for CTPA, 15 mGy and 800 mGy cm(-1) for AP, and 16 mGy and 1040 mGy cm(-1) for CAP, respectively. Regional DRLs have been proposed from this study. Dose variations across CT departments have identified an urgent need for optimisation to improve distribution of observed doses for CT examinations.


Pediatric Radiology | 2015

The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography

Joana Santos; Shane J. Foley; Graciano Paulo; Mark F. McEntee; Louise Rainford

BackgroundThe volume of CT examinations has increased with resultant increases in collective dose values over the last decade.ObjectiveTo analyze the impact of the tube current and voltage modulation for dose values and image quality of pediatric head CT examinations.Materials and methodsHead CT examinations were performed on anthropomorphic phantoms and four pediatric age categories before and after the introduction of dedicated pediatric curves for tube voltage and current modulation. Local diagnostic reference levels were calculated. Visual grading characteristic image quality evaluation was performed by four pediatric neuroradiologists and image noise comparisons were performed.ResultsPediatric-specific modulation curves demonstrated a 49% decrease in mean radiation dose for phantom examinations. The local diagnostic reference levels (CTDIvol) for clinical examinations decreased by 52%, 41%, 46% and 40% for newborn, 5-, 10- and 15-year-old patients, respectively. Visual grading characteristic image quality was maintained for the majority of age categorizations (area under the curve = 0.5) and image noise measurements did not change (P = 0.693).ConclusionPediatric-specific dose modulation curves resulted in an overall mean dose reduction of 45% with no significant differences in subjective or objective image quality findings.


British Journal of Radiology | 2015

Best single-slice location to measure visceral adipose tissue on paediatric CT scans and the relationship between anthropometric measurements, gender and VAT volume in children.

Michelle O'Connor; John Ryan; Shane J. Foley

OBJECTIVE Visceral adipose tissue (VAT) is a significant risk factor for obesity-related metabolic diseases. This study investigates (1) the best single CT slice location for predicting total abdominal VAT volume in paediatrics and (2) the relationship between waist circumference (WC), sagittal diameter (SD), gender and VAT volume. METHODS A random sample of 130 paediatric abdomen CT scans, stratified according to age and gender, was collected. Three readers measured VAT area at each intervertebral level between T12 and S1 using ImageJ analysis (National Institute of Health, Bethesda, MD) software by thresholding -190 to -30 HU and manually segmenting VAT. Single-slice VAT measurements were correlated with total VAT volume to identify the most representative slice. WC and SD were measured at L3-L4 and L4-L5 slices, respectively. Regression analysis was used to evaluate WC, SD and gender as VAT volume predictors. RESULTS Interviewer and intraviewer reliability were excellent (intraclass correlation coefficient = 0.99). Although VAT measured at multiple slices correlated strongly with abdominal VAT, only one slice in females at L2-L3 and two slices in males at L1-L2 and L5-S1 were strongly correlated across all age groups. Linear regression analysis showed that WC was strongly correlated with VAT volume (beta = 0.970, p < 0.001). CONCLUSION Single-slice VAT measurements are highly reproducible. Measurements performed at L2-L3 in females and L1-L2 or L5-S1 in males were most representative of VAT. WC is indicative of VAT. ADVANCES IN KNOWLEDGE VAT should be measured at L2-L3 in female children and at either L1-L2 or L5-S1 in males. WC is a strong indicator of VAT in children.


EJNMMI research | 2017

Carotid atherosclerotic plaques standardised uptake values: software challenges and reproducibility

Nicola Giannotti; Martin O’Connell; Shane J. Foley; Peter J. Kelly; Jonathan P. McNulty

AbstractBackgroundPositron emission tomography–computed tomography (PET-CT) carotid standardised uptake values (SUV) of 18F-fluorodeoxyglucose (18FDG) have been proposed as an inflammatory biomarker for determining cerebrovascular diseases such as stroke. Consideration of varying methodological approaches and software packages is critical to the calculation of accurate SUVs in cross-sectional and longitudinal patient studies. The aim of this study was to investigate whether or not carotid atherosclerotic plaque SUVs are consistent and reproducible between software packages. 18FDG-PET SUVs of carotids were taken in 101 patients using two different software packages. Quality assurance checks were performed to standardise techniques before commencing the analysis where data from five to seven anatomical sites were measured. A total of ten regions of interest were drawn on each site analysed. Statistical analyses were then performed to compare SUV measurements from the two software packages and to explore reproducibility of measurements. Lastly, the time taken to complete each analysis was measured and compared.ResultsStatistically significant differences in SUV measurements, between the two software packages, ranging from 9 to 21.8% were found depending on ROI location. In 79% (n = 23) of the ROI locations, the differences between the SUV measurements from each software package were found to be statistically significant. The time taken to perform the analyses and export data from the software packages also varied considerably.ConclusionsThis study highlights the importance of standardising all aspects of methodological approaches to ensure accuracy and reproducibility. Physicians must be aware that when a PET-CT data set is analysed, subsequent follow-ups must be verified, if possible, with the same software package or cross-calibration between packages should be performed.


Radiation Protection Dosimetry | 2014

Paediatric CT optimisation utilising Catphan® 600 and age-specific anthropomorphic phantoms

Joana Santos; Maria do Carmo Batista; Shane J. Foley; Graciano Paulo; Mark F. McEntee; Louise Rainford

The purpose of the study is to perform phantom-based optimisation of paediatric computed tomography (CT) protocols and quantify the impact upon radiation dose and image noise levels. The study involved three Portuguese paediatric centres. Currently employed scanning protocols for head and chest examinations and combinations of exposure parameters were applied to a Catphan(®)600 phantom to review the CT dose impact. Contrast-noise ratio (CNR) was quantified using Radia Diagnostic(®) tool. Imaging parameters, returning similar CNRs (<1) and dose savings were applied to three paediatric anthropomorphic phantoms. OsiriX software based on standard deviation pixel values facilitated image noise analysis. Currently employed protocols and age categorisation varied between centres. Manipulation of exposure parameters facilitated mean dose reductions of 33 and 28 % for paediatric head and chest CT examinations, respectively. The majority of the optimised CT examinations resulted in image noise similar to currently employed protocols. Dose reductions of up to 33 % were achieved with image quality maintained.

Collaboration


Dive into the Shane J. Foley's collaboration.

Top Co-Authors

Avatar

Louise Rainford

University College Dublin

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Graciano Paulo

Polytechnic Institute of Coimbra

View shared research outputs
Top Co-Authors

Avatar

Joana Santos

Polytechnic Institute of Coimbra

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Helen Fenlon

Mater Misericordiae University Hospital

View shared research outputs
Top Co-Authors

Avatar

Helen M. Fenlon

University College Dublin

View shared research outputs
Top Co-Authors

Avatar

L Honeyfield

University College Hospital

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge