Shota Fukuda
Cleveland Clinic
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Shota Fukuda.
Circulation | 2005
Shota Fukuda; Jong-Min Song; A. Marc Gillinov; Patrick M. McCarthy; Masao Daimon; Vorachai Kongsaerepong; James D. Thomas; Takahiro Shiota
Background—Tricuspid valve (TV) annuloplasty is recommended for functional tricuspid regurgitation (TR), which is caused by TV annulus dilatation and tethering of the leaflets. However, the impact of TV deformations on the outcome of TV annuloplasty remains unknown. The goal of this study was to investigate the relationship between preoperative TV deformation and residual TR after TV annuloplasty. Methods and Results—Two hundred sixteen patients with functional TR had 2D echocardiography before and after TV annuloplasty. Right ventricular fractional area change and left ventricular ejection fraction were determined with the apical views. Minimal TV annulus diameter was determined by frame-by-frame analysis. The distance of TV tethering was measured from the annulus plane to the coaptation point and tethering area by tracing the leaflets from the annulus plane. TR severity was determined by the ratio of the maximal jet area to the corresponding right atrial area. The severity of residual TR was associated with age, right and left ventricular dysfunction, tethering distance and area, and severity of preoperative TR (all P<0.05). TV annular dimension was not associated with outcome of TV annuloplasty. Multivariate analysis revealed that age, tethering distance, and severity of preoperative TR (all P<0.001) were independent parameters predicting residual TR. The sensitivity and specificity in predicting residual TR after surgery were 86% and 80% for tethering distances >0.76 cm and 82% and 84% for tethering areas >1.63 cm2, respectively. Conclusions—Severe TV tethering predicted residual TR after TV annuloplasty, whereas preoperative TV annular dimension was not associated with outcome of TV annuloplasty.
Circulation | 2006
Shota Fukuda; Giuseppe Saracino; Yoshiki Matsumura; Masao Daimon; Hung Tran; Neil L. Greenberg; Takeshi Hozumi; Junichi Yoshikawa; James D. Thomas; Takahiro Shiota
Background— Most rings currently used for tricuspid valve annuloplasty are formed in a single plane, whereas the actual tricuspid annulus (TA) may have a nonplanar or 3-dimensional (3D) structure. The purpose of this study was therefore to investigate the 3D geometry of the TA in healthy subjects and in patients with functional tricuspid regurgitation (TR). Methods and Results— This study consisted of 15 healthy subjects and 16 patients with functional TR who had real-time 3D echocardiography. With our customized software, 8 points along the TA were determined with the rotated plane around the axis at 45°intervals. The TA was traced during a cardiac cycle. The distance between diagonals connecting 2 points was measured. The height was defined as the distance from the plane determined by least-squares regression analysis at all 8 points. Both the maximum (7.5±2.1 versus 5.6±1.0 cm2/m2) and minimum (5.7±1.3 versus 3.9±0.8 cm2/m2) TA areas in patients with TR were larger than those in healthy subjects (both P<0.01). Healthy subjects had a nonplanar-shaped TA with homogeneous contraction. The posteroseptal portion was the lowest toward the apex from the right atrium, and the anteroseptal portion was the highest. In patients with functional TR, the TA was dilated in the septal to lateral direction, resulting in a more circular shape than in healthy subjects. A similar 3D pattern was observed in patients with TR, but it was more planar than that in healthy subjects. Conclusions— Real-time 3D echocardiography showed a complicated 3D structure of the TA, which appeared to be different from the “saddle-shaped” mitral annulus, suggesting an annuloplasty for TR different from that for mitral regurgitation.
Jacc-cardiovascular Imaging | 2013
Kenichiro Otsuka; Shota Fukuda; Atsushi Tanaka; Koki Nakanishi; Haruyuki Taguchi; Junichi Yoshikawa; Kenei Shimada; Minoru Yoshiyama
OBJECTIVES The aim of this study was to determine the predictive value of the napkin-ring sign on coronary computed tomography angiography (CTA) for future acute coronary syndrome (ACS) events in patients with coronary artery disease. BACKGROUND Recent studies have reported a close association between the napkin-ring sign on coronary CTA and thin-cap fibroatheroma. METHODS The subjects of this prospective study were 895 consecutive patients who underwent coronary CTA examination and were followed for >1 year. The primary endpoint was an ACS event (cardiac death, nonfatal myocardial infarction, or unstable angina pectoris). The coronary CTA analysis included the presence of obstructive plaque, positive remodeling (PR), low-attenuation plaque (LAP), and the napkin-ring sign. The napkin-ring sign was defined by the following criteria: 1) the presence of a ring of high attenuation around certain coronary artery plaques; and 2) attenuation of the ring presenting higher than those of the adjacent plaque and no >130 Hounsfield units. RESULTS Of the 12,727 segments, 1,174 plaques were observed, including plaques with PR in 130 segments (1.0%), LAP in 107 segments (0.8%), and napkin-ring signs in 45 segments (0.4%). Thirty-six of the 45 plaques with napkin-ring signs (80%) overlapped with those showing either PR or LAP. During the follow-up period (2.3 ± 0.8 years), 24 patients (2.6%) experienced ACS events, and plaques developed in 41% with a napkin-ring sign. Segment-based Cox proportional hazards models analysis showed that PR (p < 0.001), LAP (p = 0.007), and the napkin-ring sign (p < 0.0001) were independent predictive factors for future ACS events. Kaplan-Meier analysis demonstrated that plaques with napkin-ring signs showed a higher risk of ACS events compared with those without a napkin-ring sign. CONCLUSIONS The present study demonstrated for the first time that the napkin-ring sign demonstrated on coronary CTA was strongly associated with future ACS events, independent of other high-risk coronary CTA features. Detection of the napkin-ring sign could help identify coronary artery disease patients at high risk of future ACS events.
Circulation | 2006
Shota Fukuda; A. Marc Gillinov; Patrick M. McCarthy; William J. Stewart; Jong Min Song; Takashi Kihara; Masao Daimon; Mi Seong Shin; James D. Thomas; Takahiro Shiota
Background— The durability of tricuspid valve (TV) repair by annuloplasty is limited. Identification of mechanisms of recurrent or residual tricuspid regurgitation (TR) after annuloplasty is necessary to improve results of TV repair. The purpose of this study was to investigate echocardiographic determinants of mid-term outcome after TV annuloplasty. Methods and Results— This study consisted of 39 patients with functional TR who had echocardiography preoperatively, early postoperatively (5±2 days), and >1 year (20±6 months) after TV annuloplasty. Detailed echocardiographic measurements were performed, including TR severity, TV annular dimension, TV leaflet displacement, left ventricular (LV) function, and right ventricular (RV) function and pressures. Preoperative leaflet tethering height and area predicted early and mid-term outcome of annuloplasty. Early postoperative LV ejection fraction and TR severity influenced degree of TR >1 year after surgery. In addition, increased RV pressure was related to worse TR during late follow-up. Conclusions— Although TV tethering is an important determinant of recurrent or residual TR, LV and RV function and pressures impact repair durability. These factors identify patients at risk for repair failure; such individuals require development of additional surgical strategies to improve results of tricuspid valve repair and close surveillance after surgery.
Circulation | 2006
Masao Daimon; Shota Fukuda; David H. Adams; Patrick M. McCarthy; A. Marc Gillinov; Alain Carpentier; Farzan Filsoufi; Vivian M. Abascal; Vera H. Rigolin; Sacha P. Salzberg; Anna L. Huskin; Michelle Langenfeld; Takahiro Shiota
Background— Ischemic mitral regurgitation (IMR) is associated with asymmetric changes in annular and ventricular geometry. Surgical repair with standard symmetric annuloplasty rings results in a high incidence of residual or recurrent mitral regurgitation (MR). The Carpentier-McCarthy-Adams (CMA) IMR ETlogix annuloplasty ring is the first remodeling ring specifically designed to treat asymmetric leaflet tethering and annular dilatation. We used quantitative 2-dimensional echo to examine early results of mitral valve (MV) repair with the CMA IMR ETlogix annuloplasty ring in patients with IMR. Methods and Results— Fifty-nine patients (aged 68±12 years) with grade ≥2+ IMR (graded on a scale of 0 to 4+) underwent MV repair with the CMA IMR ETlogix annuloplasty ring. We assessed the mitral annular diameter (MAD), tethering area (TA), and tenting height (TH) of the MV in 4-chamber, 2-chamber, and long axis views at mid-systole before and 3 to 10 days after surgery. After surgery, 57 of 59 (97%) patients had grade 0 or 1+ MR, whereas 2 patients had 2+ MR. MV repair with the CMA IMR ETlogix ring significantly reduced MAD, TA, and TH (P<0.001, for all 3 echo views), particularly in the long axis and 4-chamber views. Conclusion— Surgical repair of IMR with the novel asymmetric CMA IMR ETlogix annuloplasty ring provided excellent early results with effective reduction of MR, MAD, and leaflet tethering. This novel etiology-specific strategy may result in improved outcomes in IMR patients.
American Heart Journal | 2008
Yoshiki Matsumura; Shota Fukuda; Hung Tran; Neil L. Greenberg; Nozomi Wada; Manatomo Toyono; James D. Thomas; Takahiro Shiota
BACKGROUND The geometry of the proximal isovelocity surface area (PISA) of functional mitral regurgitation (MR), which is conventionally assumed to be a hemisphere, remains to be clarified. We investigated the 3-dimensional (3D) geometry of PISA of functional MR as opposed to that of MR due to mitral valve prolapse (MVP) by real-time 3D echocardiography with color Doppler capability. METHODS Twenty-seven patients with functional MR and 27 patients with MVP were examined. The horizontal PISA length in the commissure-commissure plane and each PISA radius in 3 anteroposterior planes (medial, central, and lateral) were measured by real-time 3D echocardiography with 3D software. The effective regurgitant orifice (ERO) area was calculated with the maximum PISA radius and compared to that by 2D quantitative Doppler method. RESULTS En-face 3D color Doppler images showed an elongated and slightly curved PISA geometry along the leaflet coaptation in functional MR, whereas the geometry was rounder in MVP. The PISA horizontal length in functional MR was longer than that in MVP (2.3 +/- 0.4 vs 1.2 +/- 0.2 cm, P < .001). The PISA method with the maximum radius underestimated the ERO area by 2D quantitative Doppler method (by 24%) in functional MR, but not in MVP. CONCLUSIONS The geometry of PISA in functional MR was elongated, distinctly different from the more focal pathology of MVP, leading to underestimation of the ERO area by PISA method.
European heart journal. Acute cardiovascular care | 2016
Tsuyoshi Nishiguchi; Atsushi Tanaka; Yuichi Ozaki; Akira Taruya; Shota Fukuda; Haruyuki Taguchi; Tetsuya Iwaguro; Satoshi Ueno; Yasushi Okumoto; Takashi Akasaka
Aims: Spontaneous coronary artery dissection (SCAD) found typically in young females without classical coronary risk factors is thought to be a very rare cause of acute coronary syndrome (ACS). The prevalence of SCAD in ACS subjects has been unclear, probably due to the nature of coronary angiography. The aim of this study was to use optical coherence tomography (OCT) to investigate the prevalence of SCAD in ACS. Methods and results: This study consisted of 326 patients with ACS (with or without ST-segment elevation) who underwent OCT to explore the entire culprit artery. According to OCT findings, patients were divided into a SCAD, a plaque rupture (PR), and a non-SCAD/non-PR group. OCT revealed 13 (4.0%) SCADs and 160 (49.1%) plaque ruptures in ACS subjects. The percentage of females versus males was greater in the SCAD group (SCAD: 53.8% vs. PR: 20.0% vs. non-SCAD/non-PR: 23.5%, p=0.02) while no difference was observed in age (SCAD: 67.3±13.3 vs. PR: 66.5±11.1 vs. non-SCAD/non-PR: 67.0±10.5, p=0.90). The prevalence of dyslipidemia (SCAD: 30.8% vs. PR: 63.8% vs. non-SCAD/non-PR: 67.5%, p=0.03) and current smoking (SCAD: 7.7% vs. PR: 57.9% vs. non-SCAD/non-PR: 59.7%, p<0.01) were significantly lower in the SCAD group. Conclusions: SCAD is not a rare cause for ACS, especially in females without classical coronary risk factors.
Journal of the American College of Cardiology | 2011
Atsushi Tanaka; Kenei Shimada; Guillermo J. Tearney; Hironori Kitabata; Haruyuki Taguchi; Shota Fukuda; Manabu Kashiwagi; Takashi Kubo; Shigeho Takarada; Kumiko Hirata; Masato Mizukoshi; Junichi Yoshikawa; Brett E. Bouma; Takashi Akasaka
OBJECTIVES The aim of this study was to investigate the conformational change of arterial structure in the vasospastic lesion with optical coherence tomography. BACKGROUND Coronary artery spasm plays an important role in the pathogenesis of ischemic heart diseases. The conformational change of each arterial layer during vasospasm has not been studied in detail. METHODS We assessed 19 coronary arteries (10 spasm and 9 nonspasm lesions) with optical coherence tomography during the provocation test for coronary spasm. An intimal bump was defined as 1 or more intimal projections into the lumen that disappeared after the administration of nitroglycerine (NTG). Intimal gathering was defined as a folding/gathering of the intima, resulting in multiple kinks in the luminal contour that resolved after the administration of NTG. RESULTS The spasm lesion more frequently showed an intimal bump at baseline and intimal gathering during spasm compared with the nonspasm lesion (spasm 80% vs. nonspasm 0%, p < 0.01, spasm 100% vs. nonspasm 0%, p < 0.01, respectively). The spasm lesion demonstrated a thicker maximum media thickness (spasm 0.24 ± 0.04 mm vs. nonspasm 0.12 ± 0.03 mm, p < 0.01) at baseline, whereas no differences were observed after the administration of NTG (spasm 0.13 ± 0.03 mm vs. nonspasm 0.13 ± 0.02 mm, p = 0.65). CONCLUSIONS Our results suggest that medial contraction occurs even in an asymptomatic state and facilitates the formation of an intimal bump in patients with vasospastic angina. Luminal narrowing during spasm is associated with intimal gathering without alteration of intimal area.
Echocardiography-a Journal of Cardiovascular Ultrasound and Allied Techniques | 2008
Masao Daimon; Giuseppe Saracino; A. Marc Gillinov; Yasushi Koyama; Shota Fukuda; Jun Kwan; Jong Min Song; Vorachai Kongsaerepong; James D. Thomas; Takahiro Shiota
Objective: Most studies of the pathogenesis of functional mitral regurgitation (MR) have focused on alterations in ventricular function and geometry. We used a novel 3D echocardiographic method to assess abnormalities in mitral annular (MA) geometry and motion in patients with ischemic MR (IMR) and compared these data to those obtained from normal subjects and from patients with MR caused by dilated cardiomyopathy (DMR). Methods: Real time 3D echo was performed in 12 normal subjects, 25 with IMR, and 14 with DMR. Eight points along the saddle‐shaped MA were identified using our software at systole and diastole. From these eight points, four annular diameters at each cardiac phase were determined. Annular motion was assessed by measuring local displacement (LD) of a given point between systole and diastole. Results: Annular motion was different between groups: IMR had smaller LD in posterior MA segments than did normals (2.6 ± 1.1 vs 4.8 ± 1.9 mm, P < 0.01), while DMR had globally reduced LD. In IMR systolic MA dilatation was striking in the anterior–posterior (diameter; IMR vs controls, 28.3 ± 3.5 vs 22.5 ± 2.2 mm, P< 0.05) and anterolateral–posteromedial (31.7 ± 3.5 vs 25.1 ± 2.2 mm, P < 0.05) directions; in IMR, systolic MA diameters in these two directions correlated with MR severity (P = 0.02) . MA dilatation occurred globally in DMR. Conclusion: This novel 3D echo method demonstrated that MA motion and dilatation were asymmetric in IMR and symmetric in DMR. These differences in MA geometry and motion may aid in the development of distinct new therapies for IMR and DMR.
Journal of The American Society of Echocardiography | 2009
Toshihiro Kawasaki; Shota Fukuda; Kenei Shimada; Kumiko Maeda; Yoshida K; Hiroe Sunada; Hitoshi Inanami; Hidemasa Tanaka; Satoshi Jissho; Haruyuki Taguchi; Minoru Yoshiyama; Junichi Yoshikawa
OBJECTIVE The elastic properties of the carotid arterial wall have not been directly characterized in the clinical setting. Strain rate (SR) imaging is a newly developed echocardiographic method developed for imaging the tissue motion of the myocardium. The purpose of this study was to directly estimate the elastic properties of the carotid artery by using SR imaging in patients with coronary artery disease (CAD). METHODS A total of 135 patients with CAD, 15 age-matched controls, and 35 young healthy subjects had a carotid ultrasound examination for measuring the values of SR and strain of the carotid artery. The intima-media thickness and distensibility coefficient of the carotid artery were estimated. RESULTS Age and Framingham risk score were significantly related to SR and strain, respectively (r = 0.62-0.67, all P < .001). These strain measurements were significantly correlated with distensibility coefficient and intima-media thickness, respectively (r = 0.30-0.56, all P < .001). Similar values of the areas under the receiver operating characteristic curves were obtained among Framingham risk score (0.70 +/- 0.05), SR (0.67 +/- 0.05), and strain (0.73 +/- 0.05). CONCLUSION This study demonstrated that the elastic properties of the carotid artery wall were directly characterized by using SR imaging in patients with CAD.