Shuchi Dixit
Indian Institute of Technology Roorkee
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Shuchi Dixit.
Biomedical Chromatography | 2012
Ravi Bhushan; Shuchi Dixit
Amino acids are unique in terms of their structural features and multidimensional uses. With their simple structures and the ready availability of both enantiomers, amino acids not only serve as a chiral pool for synthesis but also provide an inexpensive pool for resolution studies. There has been no attempt to review the application of amino acids as chiral selectors for chromatographic enantioresolution of pharmaceuticals and other compounds. The present paper deals with application of l-amino acids and complexes of l-amino acids with a metal ion, particularly Cu(II), as an impregnating reagent in thin-layer chromatography or as a chiral ligand exchange reagent or a chiral mobile phase additive in both thin-layer chromatography and high-performance liquid chromatography. Enantiomeric resolution of β-blockers, nonsteroidal anti-inflammatories, amino acids (and their derivatives) and certain other compounds is discussed.
Journal of Chromatography A | 2010
Ravi Bhushan; Shuchi Dixit
Four dichloro-s-triazine (DCT) and five monochloro-s-triazine (MCT) chiral derivatizing reagents (CDRs) were synthesized by incorporating amino acid amide moieties as chiral auxiliaries in trichloro-s-triazine and its 6-methoxy derivative, respectively. Another MCT reagent was synthesized by substitution of two chlorine atoms with two different amino acid amides in trichloro-s-triazine. These reagents were used for synthesis of diastereomers of (R,S)-baclofen under microwave irradiation (i.e. 60 s at 85% power using DCT reagents and 90 s at 85% power using MCT reagents). The diastereomers were separated on a reversed-phase C18 column using mixtures of methanol with aqueous trifluoroacetic acid (TFA) with UV detection at 230 nm. The separation behavior in terms of retention times and resolutions obtained for the two sets of diastereomers prepared with DCT and MCT reagents were compared among themselves and among the two groups. Longer retention times and better resolutions were observed with DCT reagents as compared to MCT reagents. The calibration curves were linear for both (R)- and (S)-baclofen in the concentration range 50-500 μg/ml. The average regression was 0.999 for both (R)- and (S)-baclofen. The RSD for (R)-baclofen was 0.40-0.86% for intra-day precision and 0.60-1.40% for inter-day precision and these values for (S)-baclofen were 0.52-0.75% and 0.64-1.32%, respectively. The recovery was 97.2-98.9% for (R)- and 97.0-98.9% for (S)-baclofen. The limit of detection was 1.63 ng/ml and 1.52 ng/ml for (R)- and (S)-baclofen, respectively.
Journal of Chromatography A | 2010
Ravi Bhushan; Shuchi Dixit
A new series of chiral derivatizing reagents (CDRs) consisting of four dichloro-s-triazine reagents was synthesized by nucleophilic substitution of one chlorine atom in trichloro-s-triazine with amino acids, namely L-Leu, D-Phg, L-Val and L-Ala as chiral auxiliaries. Two other sets of CDRs consisting of four dichloro-s-triazine (DCT) and six monochloro-s-triazine (MCT) reagents were also prepared by nucleophilic substitution of chlorine atom(s) with different amino acid amides as chiral auxiliaries in trichloro-s-triazine and its 6-methoxy derivative, respectively. These 14 CDRs were used for the synthesis of diastereomers of (R,S)-mexiletine under microwave irradiation (i.e. 60s and 90 s at 85% power (of 800 W) using DCT and MCT reagents, respectively), which were resolved by reversed-phase high-performance liquid chromatography using C18 column and gradient eluting mixtures of methanol with aqueous trifluoroacetic acid (TFA) with UV detection at 230 nm. The resolution (R(s)), difference between retention times of resolved diastereomers (Δt) and retention factors (k) obtained for the three sets of diastereomers were compared among themselves and among the three groups. Explanations have been offered for longer retention times and better resolution of diastereomers prepared with DCT reagents in comparison of their MCT counterparts and, for the influence of hydrophobicity of the side chain R of the amino acid in the CDRs on retention times and resolution. The newly synthesized CDRs were observed to be superior as compared to their amide counterparts in terms of providing better resolution and cost effectiveness. The method was validated for limit of detection, linearity, accuracy and precision.
Biomedical Chromatography | 2012
Ravi Bhushan; Shuchi Dixit
Enantioseparation of five β-blockers, namely, (R,S)-atenolol, (R,S)-propranolol, (R,S)-bisoprolol, (R,S)-metoprolol and (R,S)-carvedilol, was achieved as their diastereomers prepared with chiral derivatizing reagents (CDRs) synthesized on a cyanuric chloride platform. Fifteen CDRs were synthesized by nucleophilic substitution of the Cl atom in cyanuric chloride or its 6-methoxy derivative with amino acids (namely, L-Leu, L-Val, D-Phg, L-Met and L-Ala) or their amides as chiral auxiliaries. The diastereomers were synthesized under microwave irradiation for 70 or 100 s at 85% power. Separation of diastereomers was carried out on a C(18) column and gradient eluting mixtures of methanol with aqueous trifluoroacetic acid with UV detection at 230 nm. Separation efficiencies of the reagents were compared on the basis of effect of chiral auxiliaries (i.e. amino acids or amino acid amides) and achiral substituents (i.e. chlorine or methoxy group) in the CDRs. The method was validated for detection limit, linearity, accuracy and precision.
Biomedical Chromatography | 2012
Ravi Bhushan; Shuchi Dixit
Enantioresolution of (R,S)-baclofen was accomplished using a newly synthesized set of three chiral derivatizing reagents (CDRs) having amines [(S)-(-)-α,4-dimethylbenzylamine, (-)-cis-myrtanylamine and (R)-(-)-1-cyclohexylethylamine] as chiral auxiliaries in cyanuric chloride and another set of five CDRs having amino acids (L-Leu, D-Phg, L-Val, L-Met and L-Ala) as chiral auxiliaries. These eight CDRs were used for synthesis of diastereomers of (R,S)-baclofen under microwave irradiation. The diastereomers were separated on a reversed-phase C(18) column using mixtures of methanol with aqueous trifluoroacetic acid with UV detection at 230 nm. Chromatographic data obtained for the two sets of diastereomers were compared among themselves and among the two groups. The method was validated for limit of detection, linearity, accuracy and precision.
Jpc-journal of Planar Chromatography-modern Tlc | 2012
Ravi Bhushan; Jürgen Martens; Charu Agarwal; Shuchi Dixit
Cu(II) complexes of l-threonine, l-serine, and l-tartaric acid were prepared and used as ligand exchange reagents for enantiomeric resolution of some of the β-blockers (bisoprolol, metoprolol, and propranolol) and a β2-agonist (salbutamol). Impregnated thin-layer plates were prepared by spreading slurry of silica gel prepared in the solutions of each of the three ligand exchange reagents. The spots were detected with iodine. Effect of temperature on enantioresolution was also studied. The detection limits were found in the range 0.19–0.26 µg for each enantiomer. l-Ser proved to be a good ligand using a common mobile phase in each case.
Advanced Materials Research | 2009
Shuchi Dixit; P. Jeevanandam
An easy onepot reaction for the synthesis of iron oxide nanoparticles is reported. Thermal decomposition of iron acetyl acetonate (Fe(acac)3) in diphenyl ether, in the presence of oleic acid and oleyl amine followed by calcination, leads to the formation of iron oxide nanoparticles. Variation of concentration of the oleyl amine during the synthesis affects the morphology of the iron oxide nanoparticles produced.
Amino Acids | 2012
Ravi Bhushan; Shuchi Dixit
Chromatographia | 2011
Ravi Bhushan; Shuchi Dixit
Biomedical Chromatography | 2011
Ravi Bhushan; Shivani Tanwar; Shuchi Dixit